Skip to main content

11"W x 16"H x 6.5"D - Cleanroom 2-Compartment 5" x 6" Glove Pak Dispenser

$180.00
(No reviews yet)
SKU:
CH-12/12
Availability:
Made to Order, 14 - 21 Business Days
Shipping:
$20.00 (Fixed Shipping Cost)
Quantity Option (Each):
1 Dispenser
11"W x 16"H x 6.5"D Cleanroom 2-Compartment 5" x 6" Glove Pak Dispenser — Sterile Pair-Pack Workflow Control
Sterile pair-pack (walleted) gloves solve one problem and can create another: they reduce exposure and handling, but if the wallets are staged loosely on shelving, they get touched repeatedly, bent, and mixed between lots or sizes. This dispenser is built to keep sterile glove wallets protected, organized, and dispensed in a true first-in/first-out flow, so operators can pull consistently without “digging” through inventory.

The result is practical and measurable in most facilities: fewer touches per wallet, fewer damaged pouches, fewer mix-ups, and less glove waste at the point of use.

Published configuration (CH-12/12)
  • SKU: CH-12/12
  • Overall size: 11"W x 16"H x 6.5"D
  • Compartments: 2
  • Designed for: 5" x 6" sterile glove wallets (pair-pack)
  • Inventory control: Protects and dispenses first-in/first-out (FIFO)
  • Construction: 1/4" clear acrylic or 1/4" clean PETG (PETG noted safe with IPA)
  • Lid design: Sloped lid to help maintain HEPA airflow; full-length hinge for durability
  • Mounting: Wall-mountable or free-standing
  • Edge finish: Flame-treated edges for smoothness
  • Case unit: 1 dispenser per case
  • Availability: Made to Order, 14–21 business days
Why this dispenser reduces contamination risk
Pair-pack gloves are chosen to minimize handling and exposure. A purpose-built wallet dispenser extends that benefit by keeping the remaining inventory covered and presented the same way every time. That reduces secondary contamination opportunities caused by repeated touching, searching, and re-staging.

Material selection: Acrylic vs PETG (match your wipe-down SOP)
This dispenser is offered in acrylic or PETG. Your best choice depends on how your facility cleans wall fixtures:
  • Acrylic: Ideal when the environment does not require cleaning dispensers with IPA or harsh chemicals. Acrylic is highly scratch-resistant and is typically cleaned with soap and water.
  • PETG: Selected for compatibility with IPA (isopropyl alcohol) and other harsh chemicals. If IPA wipe-down is routine in your program, PETG is generally the safer long-term material choice.
Waste reduction, in plain terms
When glove wallets are stored loosely, pouches get creased, corners tear, and operators often pull two packs to “find a good one.” Covered FIFO dispensing is one of the simplest ways to reduce that avoidable waste.

Build the complete station 
Sterile / cleanroom gloves 
Wipers 

Installation and use guidance 
  • Mount at the decision point: gowning bench boundary, airlock exit, or at the entrance to the critical corridor—where glove changes are expected.
  • Label by lot / date received : supports FIFO behavior and reduces the chance of “new pack on top” habits.
  • Do not overfill: over-compression can crease pouches and defeats the purpose of protected dispensing.
  • Keep the lid closed between pulls: especially in corridors where airflow and traffic increase particulate loading on exposed surfaces.
Important notes 
Dispenser ships as the fixture only. Items shown in photos (gloves, bouffants, wipers, apparel) are not included. Photos may not represent the selected material type; acrylic is typically very clear while PETG may have a slightly darker tint.
If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574.

Check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try!
 
THIS IS NEW FOR 2026!

© 2026 SOS Supply. All rights reserved.
The Technical Vault
By SOSCleanroom
Sterile Pair-Pack Controls
CH-12/12 — 2-Compartment 5" x 6" Wallet Dispenser
5" x 6" Glove Wallets FIFO Dispensing Sloped Lid + Full-Length Hinge 1/4" Acrylic or PETG 11"W x 16"H x 6.5"D
Why walleted gloves still need a dispensing control
Pair-pack gloves are selected for a reason: they limit exposure and standardize presentation. But the system only works when the remaining inventory is not repeatedly handled. In real facilities, “open shelf staging” tends to create three predictable failure modes:
  • Excess touches: operators rummage for the right size or newest pack.
  • Pouch damage: wallets get creased, corners tear, seals are stressed.
  • FIFO drift: new packs get placed on top; older stock becomes “invisible.”
A purpose-built wallet dispenser prevents these by forcing controlled access and maintaining FIFO dispensing behavior.

1) Verified fixture specifications (for qualification planning)
Attribute Published value Why it matters
SKU CH-12/12 Supports standardization and replacement under change control.
Format 2 compartments for 5" x 6" glove wallets Enables two sizes or two approvals while keeping wallet format disciplined.
Construction 1/4" clear acrylic or 1/4" clean PETG (PETG noted safe with IPA) Material must match disinfectant chemistry to prevent long-term deterioration.
Lid / hinge Sloped lid; full-length hinge Covered inventory + durable access behavior at high-touch locations.
Mounting Wall-mountable or free-standing Supports consistent placement at gowning boundaries and workcells.
Size 11"W x 16"H x 6.5"D Compact footprint for airlocks and corridors where wall space is limited.

2) Acrylic vs PETG: a cleaning-validation decision
The product listing distinguishes the two polymers clearly: acrylic is scratch-resistant and typically cleaned with soap and water, while PETG is selected for compatibility with IPA and harsher chemicals used in many regulated environments. If IPA wipe-down is routine for fixtures in your gowning area, PETG is generally the safer selection for long-term durability.
Operational best practice
Standardize material across adjacent wall fixtures (dispensers, shelving, holders) so the same disinfectant chemistry and technique can be applied consistently without risking long-term damage to one fixture type.

3) Station pairings (Texwipe + Ansell + Kimtech) with internal links
Why SOSCleanroom for point-of-use controls
A glove wallet dispenser is most effective when it is part of a controlled station: consistent placement, defined restock roles, labeled approvals, and materials aligned to cleaning SOPs. SOSCleanroom supports that approach with deep coverage across Texwipe, Ansell, and Kimtech—plus responsive help when you are qualifying or re-standardizing a sterile glove workflow.
© 2026 SOS Supply. All rights reserved.