Micronova CR100IR™ Irradiated Vinyl Cleanroom Tape — Gamma-Irradiated, Double-Bagged Vinyl Tape for Critical & Aseptic Processing (36 Yards/Roll)
Gamma Irradiated Vinyl Tape Rubber PSA Adhesive Double-Bagged Lot Traceable 36 Yards/Roll

Overview

CR100IR™ is an ultra-processed, gamma-irradiated vinyl cleanroom tape engineered to help limit particulate and bio-burden introduction for critical and aseptic processing tasks such as media preparation, batching, color-coding, and packaging. The tape is specified as double-bagged, wound on a 3" plastic core, and supplied with certification documents to support qualification and traceability.

SOSCleanroom supports cleanroom and electronics programs by stocking the right consumables, keeping configurations consistent, and helping customers select products that match their SOPs and audit expectations.


Why this tape matters
  • Designed for critical workflows: specified for aseptic processing applications where particulate and bio-burden discipline matters.
  • Cleaner staging: individually double-bagged to support controlled introduction into clean areas.
  • Traceability for quality systems: lot numbers are specified to print on each roll and case; certificates ship with each order.
  • Operational consistency: standardize your visual controls (zones, batch status, labeling) without office-grade tape substitutions.

Typical tasks supported
  • Media preparation labeling and status identification
  • Batching and color-coding of materials, carts, and containers
  • Packaging identification for controlled transfers
  • General cleanroom marking where irradiated presentation is required by the program

Key specifications (published)
Backing / adhesive Vinyl film / Rubber-based pressure sensitive adhesive (PSA)
Roll length / core 36 yards / 3" plastic core
Irradiation standard Minimum irradiation dose: 25 kGy (manufacturer specification)
Autoclavability Autoclavable when applied to glass or stainless-steel surfaces (manufacturer specification)
Chemical compatibility / shelf life Good compatibility with common solutions; 24 months shelf life (manufacturer specification)
Packaging / traceability Individually double-bagged; lot numbers printed on each roll and case

Performance depends on surface preparation, application pressure, and removal technique. For best results, apply to a clean, dry surface and remove slowly at a low peel angle.


Ordering (SOSCleanroom configurations)
Available quantity option Case
Tape sizes (this listing) 1" x 36 yards or 2" x 36 yards
Case unit (1" x 36 yards) 36 rolls per case
Case unit (2" x 36 yards) 24 rolls per case
Available color options (this listing) Red, White, Dark Green

Important: Gamma-irradiated products are listed as non-returnable. This item typically ships with a 2–3 week lead time.


Documentation

Use manufacturer documents for qualification packets, internal review, and change-control support.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.
The Technical Vault By SOSCleanroom
Aseptic Processing Visual Controls / 5S Traceability ESD Awareness

Why irradiated tape exists (and when it is worth it)

Tape is a deceptively important consumable in controlled environments. It touches containers, carts, staging tables, and transfer packaging. In critical and aseptic processing, those contact points can become unplanned contamination inputs. CR100IR™ is positioned as an ultra-processed, gamma-irradiated vinyl tape intended to help limit particulate and bio-burden counts, while still supporting day-to-day visual management: media prep labeling, batch status ID, color-coding, and packaging identification.


What “audit-friendly” looks like for tape

Quality systems are built on repeatability and evidence. For tape, that typically means: consistent part numbers, controlled introduction into the area, and documentation that can be filed with the lot record or maintenance packet. CR100IR is specified as individually double-bagged with lot numbers printed on each roll and case, and the manufacturer specifies that a Certificate of Irradiation and Certificate of Conformance ship with each order.

Best practice: Treat tape like any other controlled consumable. Stage it in designated locations, maintain lot/expiry records, and avoid “equivalent tape” substitutions that can change residue behavior, adhesion strength, or documentation availability.


How to use vinyl tape without creating rework
  1. Prep the surface: wipe and fully dry. Residue and oils are the fastest path to adhesive transfer and edge lift.
  2. Apply with firm pressure: consistent pressure improves edge sealing and reduces flagging.
  3. Standardize your visual language: define what each color means (status, zone, batch stage) and keep it consistent site-wide.
  4. Remove correctly: peel slowly at a low angle; don’t “snap” tape off a surface.
  5. Know the temperature method: the manufacturer specifies autoclavability only when applied to glass or stainless-steel surfaces.

ESD and electronics: where tape fits (and where it does not)

Many SOSCleanroom customers operate in electronics manufacturing, semiconductor support operations, optics, metrology, and lab environments where electrostatic discharge (ESD) can damage parts immediately or create latent defects. Formal ESD programs commonly align to ANSI/ESD S20.20 and/or IEC 61340-5-1, which describe the administrative and technical requirements for an ESD control program.

Practical guidance: CR100IR is a cleanroom/aseptic tape. It is not a substitute for grounding or ESD control materials. If your process occurs inside an EPA (ESD Protected Area), confirm whether your program requires anti-static / static dissipative tapes and pair that selection with validated grounding (wrist straps, heel grounders, and verification testers/monitors).


Why buy CR100IR from SOSCleanroom
  • Configuration control: consistent sizes/colors and case packs reduce “equivalent tape” substitutions.
  • Program support: we help match tape type to task (irradiated vs. cleanroom grade vs. ESD-aware vs. construction).
  • Planning transparency: irradiated items are typically non-returnable and often carry lead times—knowing this up front prevents schedule surprises.
  • One-cart procurement: combine tapes with cleanroom wipes, disinfectants, and ESD controls to streamline purchasing.

If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.