Kimtech™ 10022 A8 Certified Lab Coat with Knit Cuffs & Collar — Large
Disposable lab coat  ·  White  ·  Mid-calf  ·  3-layer SMS  ·  Knit cuffs + knit collar  ·  6-snap front
Mfr Part #: 10022
Series: Kimtech™ A8 Certified Lab Coats
What it is

Kimtech™ 10022 is an A8 Certified disposable lab coat built on a 3-layer SMS (spunbond-meltblown-spunbond) nonwoven barrier platform for laboratory and light industrial environments where the anticipated exposure is low-to-moderate for chemicals or fluids. Compared to the standard A8 lab coat, the 10022 adds a knit collar alongside elastic knit cuffs — closing the neckline gap and reducing exposure variability at both ends of the sleeve. The mid-calf length provides extended torso and lower-body coverage versus hip-length jacket formats.

Construction & design
Material 3-layer SMS nonwoven (spunbond-meltblown-spunbond)
Size / fit Large (unisex)
Length Mid-calf
Front closure 6-snap
Cuffs Elastic knit — maintains sleeve position at the glove interface
Collar Knit collar — reduces neckline gap and improves upper-torso coverage consistency
Back vent Yes — supports airflow during extended wear
Pockets 3 reinforced
Neck loop Yes
Pack configuration 25 lab coats/case
Performance intent

Designed for general laboratory PPE in research, QA/QC, pharmaceutical support areas, and industrial lab settings. Mid-calf length extends lower-body protection versus hip-length jacket formats. The knit collar reduces neckline exposure variability — a gap point on standard lab coats that rely on collar fit alone. Knit cuffs reduce sleeve migration and wrist exposure during overhead and lateral movement. The 6-snap front, knit cuffs, and knit collar together define the garment's three controlled-interface points — all must be used correctly per SOP.

Hazard boundary: This garment is positioned for low-to-moderate chemical and fluid exposure. It is not a substitute for task-validated chemical splash PPE. Specify PPE per your EHS hazard assessment for higher-exposure tasks.
Brand note: The Kimtech™ PPE business was acquired by Ansell from Kimberly-Clark's KCPPE division. Part numbers and specifications remain aligned with manufacturer documentation under Ansell stewardship. For regulated or audit-controlled environments, always reference the current technical data sheet for this SKU.
Kimtech 10022 A8 Lab Coat with Knit Cuffs & Collar Technical Vault | SOSCleanroom
The Technical Vault By SOSCleanroom
Kimtech™ A8 Certified 3-Layer SMS Barrier Mid-Calf Coverage Knit Cuffs + Knit Collar 6-Snap Front 3 Reinforced Pockets 25/Case

Kimtech™ 10022 A8 Lab Coat with Knit Cuffs & Collar (Large): closing the wrist and neckline gap in lab PPE programs

The Kimtech™ 10022 is an A8 Certified disposable lab coat built on a 3-layer SMS (spunbond-meltblown-spunbond) nonwoven barrier platform for laboratory and light industrial environments where the anticipated exposure is low-to-moderate for chemicals or fluids. The 10022 adds a knit collar to the standard A8 lab coat configuration — addressing the neckline gap that open-collar garments leave exposed — while retaining elastic knit cuffs for controlled sleeve position at the glove interface.

The mid-calf length extends lower torso and upper leg coverage beyond hip-length jacket formats. A 6-snap front closure, back vent, three reinforced pockets, and integrated neck loop complete the design for active bench and production environments.

Operations takeaway: The 10022 controls three common exposure gap points — wrist, neckline, and front opening. All three require procedural discipline to deliver their protective intent: glove-over-cuff, collar seated correctly, and all 6 snaps closed during active work.

Quick-reference specifications (SKU-level control for SOPs, RFQs, and receiving)
Parameter10022 Value / Detail
Product nameKimtech™ A8 Certified Lab Coat with Knit Cuffs & Collar
Manufacturer part #10022
BrandKimtech™ (Kimberly-Clark PPE, now part of Ansell)
ColorWhite
Size / fitLarge (unisex)
LengthMid-calf
Material / structure3-layer SMS nonwoven (spunbond-meltblown-spunbond)
CuffsElastic knit — maintains sleeve position at glove interface
CollarKnit — reduces neckline gap; improves upper-torso coverage consistency
Front closure6-snap
Pockets3 reinforced
VentilationBack vent
Neck loopYes
Pack configuration25 lab coats/case
Documentation rule: For validated or audit-controlled programs, base acceptance criteria on current manufacturer documentation and lot records — not web summaries, including this one.

Performance characteristics
Barrier & protection positioning
PropertyDetail
Barrier platform3-layer SMS nonwoven; designed for low-to-moderate chemical and fluid exposure environments
Certification levelKimtech™ A8 Certified — confirm current scope against manufacturer documentation
Knit collar advantageReduces neckline gap — a common exposure point on standard open-collar lab coats
Knit cuff advantageReduces wrist gap and sleeve migration during overhead and lateral movement
Coverage vs. jacketMid-calf length reduces incidental lower-body contamination transfer during leaning, seated work, and surface contact
Hazard boundary: This garment is positioned for low-to-moderate chemical and fluid exposure. It is not a substitute for task-validated chemical splash PPE. Specify PPE per your EHS hazard assessment for higher-exposure tasks.
Comfort & fit features
FeatureFunctional benefit
Elastic knit cuffsMaintains sleeve position at glove interface; reduces wrist gap during overhead and lateral movement
Knit collarSeats consistently at the neckline; reduces exposure variability at upper-torso coverage point
6-snap front closureFull-length closure from collar to hem; all snaps must be engaged during active work
Back ventSupports airflow to reduce heat buildup during extended wear
Neck loopAllows garment to be hung at the workstation without bench or floor contact
3 reinforced pocketsSupports tool and instrument staging; reinforcement reduces pocket tear-out under load
10022 vs. standard A8 lab coat: when to specify the knit collar configuration

The standard Kimtech™ A8 lab coat (10071 Medium, 10072 Large) uses an open collar with snap closure only. The 10022 replaces the open collar with a fitted knit collar, which seats more consistently against the neck and reduces the gap that can form during movement, leaning, or reaching. Specify the 10022 when your risk assessment or SOP identifies neckline exposure as a control point — particularly in splash-adjacent tasks, mist environments, or protocols where upper-torso coverage consistency is audited.

Corporate transition: Kimberly-Clark PPE → Ansell

The Kimtech™ and KleenGuard™ PPE portfolio was acquired by Ansell from Kimberly-Clark's KCPPE division. Product part numbers and specifications remain aligned with published manufacturer documentation. For regulated or audit-controlled environments, always reference current technical data under Ansell stewardship.


Intended use cases
  • Routine bench work, sample handling, and general lab operations where torso, sleeve, and neckline protection are required
  • Environments where neckline exposure is a defined control point in the risk assessment or SOP
  • Workflows where knit cuffs and knit collar together reduce exposure variability at both interface points
  • Extended-wear settings where back vent reduces heat buildup during long shifts
  • Light industrial and pharmaceutical support settings where low-to-moderate splash or fluid contact is the anticipated hazard
Configuration selection guide: Choose 10022 (knit cuffs + knit collar) when neckline coverage consistency is a protocol requirement. Choose 10071/10072 (knit cuffs, open collar) when neckline exposure is not a defined control point and collar comfort is the priority.

Best-practice use
  1. Size for full closure: Confirm the snap front closes without tension across the full length and sleeves maintain coverage during reaching and overhead work.
  2. Close all 6 snaps: All snaps from collar to hem must be engaged during any task where the garment's barrier is relied upon.
  3. Seat the knit collar correctly: The collar should sit flat and consistently against the neck — not folded down or pulled out of position — before beginning work.
  4. Glove-over-cuff rule: Pull gloves over knit cuffs per SOP. This is the primary wrist-exposure control — confirm it is written, trained, and observed.
  5. Don/doff per procedure: Avoid touching the garment exterior with ungloved or contaminated hands during removal. Define a doffing sequence and train to it.
  6. Use the neck loop: When temporarily removed, hang via the neck loop to avoid exterior surface contact with bench tops, chairs, or floors.
  7. Change-out triggers: Replace immediately if torn, visibly soiled, fluid-wet, or after any spill or splash event. Define trigger points in the SOP.
SOP standardization tip: The 10022 has three controlled interface points versus two on a standard lab coat. Lock five variables in the written procedure: size selection criteria, all-snaps-closed rule, collar-seated rule, glove-over-cuff requirement, and documented change-out triggers.

When Kimtech 10022 is not the right choice
  • Sterile or aseptic workflows requiring sterile garments: 10022 is non-sterile. Specify the garment class required by your protocol and applicable standard.
  • High-splash or chemical permeation-hazard tasks: Specify PPE validated for the hazard per your EHS assessment.
  • Environments where pockets are contamination-control risks: Choose a no-pocket garment configuration when pocket-as-contamination-trap risk is unacceptable.
  • Full lower-body coverage required: Select a coverall when the hazard boundary extends below mid-calf.
  • Reuse after soiling or fluid contact: This is a single-use disposable garment. Do not launder or reuse after any compromise event.

Recommended glove pairing (process-aligned)

Lab coats and gloves function as a system. The knit cuff on the 10022 is only effective as a wrist-exposure control when paired with a glove that is consistently pulled over it per procedure. Select a glove appropriate for your chemical and contamination risk, then standardize the interface.

Glove interface rule: Knit cuffs control sleeve position — the glove is the actual wrist barrier. If gloves are loose, torn, or contaminated, knit-cuff coverage provides no additional protection. Treat glove integrity as a first-order control during all operations.

Why source Kimtech™ 10022 from SOSCleanroom
  • Exact SKU + case configuration control: Ordering by part number 10022 and confirmed case pack (25/case) reduces the risk of receiving a non-equivalent substitute garment that lacks the knit collar feature.
  • Brand continuity after acquisition: Kimtech™ PPE is now under Ansell. SOSCleanroom sources the current product line under the correct successor SKUs, reducing procurement confusion during the brand transition.
  • Audit-readiness support: We help customers locate current TDS documentation, certification records, and lot continuity information to support receiving qualification and audit evidence packages.
  • Consolidated procurement: Pair garments with Ansell cleanroom gloves, Texwipe wipers, IPA, and other facility consumables in a single order.

Authoritative reference documents