Kimtech™ PURE* A7 Cleanroom Lab Coat (47652) — Size Medium (M), White — 30/Case

Kimtech™ PURE* A7 Cleanroom Lab Coat 47652 (Medium) is a cleanroom-positioned disposable lab coat designed for contamination control and liquid-splash workflows where a low-lint, anti-static garment and bulk cleanroom double-bag packaging help reduce handling variables at the gowning boundary. Manufacturer product information highlights a mandarin/high collar, thumb loops, and triple-stitched seams to support more stable coverage and a more reliable glove-to-sleeve interface during operator movement.

Cleanroom note: Garments reduce contamination risk only when paired with correct gowning sequence and technique. Use within a documented gowning program aligned to your ISO cleanroom classification and process risk.

Specifications (Manufacturer-Published):
  • Manufacturer / brand family: Kimtech™ (Kimberly-Clark Professional* / Ansell)
  • Part number (SKU): 47652
  • Garment type: Cleanroom lab coat (non-sterile)
  • Size: Medium (M)
  • Case pack: 30 lab coats per case
  • Packaging (seller/manufacturer listing): Bulk cleanroom packaging (double bag)
  • Color: White
  • Material / construction (manufacturer Product Information): Abrasion-resistant film-coated polypropylene; high strength triple stitched seams; snap front; left chest pocket; mandarin collar; elastic cuff; thumb loops; extra-length arms
  • Anti-static statement (manufacturer Product Information): Antistatic clothing (EN 1149-5:2008)
  • Low-lint statement (manufacturer Product Information): Low lint fabric (Helmke Drum Category II)
  • Barrier / splash statement (manufacturer listing): Passes ASTM F1670 for penetration of blood and body fluids
  • PPE classification statement (manufacturer Product Information): Certified PPE Cat II; Type 6 limited chemical splash protection (directive 89/686/EEC as referenced on Product Information)
  • Material exclusions (manufacturer Product Information): Product not made with silicone; not made with BHT preservative; not made with natural rubber latex
  • Size-specific dimensions (manufacturer Product Information): Chest width 60 cm; sleeve length 63 cm; total length 101 cm
About the Manufacturer:

Kimtech™ cleanroom apparel is positioned for controlled environments where contamination control and consistent operator coverage matter. For lab-coat workflows, the high collar, elastic cuffs, and thumb loops help reduce common interface gaps at wrists and neck—two areas frequently associated with coverage breakdown when operators reach, bend, or adjust gloves.

 

Always qualify garment choice to your environment, process risk, and cleanroom classification. Where sterile-area entry, aseptic operations, or Annex 1 Grade-driven controls apply, facilities typically require sterile garments and more stringent gowning controls than a non-sterile lab coat program.

Key Features:
  • Bulk cleanroom packaging (double bag) for cleaner introduction practices
  • Mandarin/high collar for improved neck coverage
  • Elastic cuffs with thumb loops to help maintain glove-to-sleeve interface
  • Triple stitched seams for robust construction
  • Snap front; left chest pocket
  • Low lint fabric (Helmke Drum Category II)
  • Antistatic clothing reference (EN 1149-5:2008)
  • ASTM F1670 pass claim for penetration of blood and body fluids (manufacturer listing)
  • Not made with silicone; not made with BHT; not made with natural rubber latex (manufacturer Product Information)
Benefits in Cleanroom Use:
  • Supports contamination control habits: Low-lint and anti-static positioning helps reduce particle transfer risk when paired with correct donning technique.
  • Improves interface control: Thumb loops and elastic cuffs help keep sleeves seated under gloves during movement.
  • Cleaner staging at the boundary: Double-bag packaging helps reduce handling variability when garments enter controlled spaces.
  • Practical splash-oriented coverage: Manufacturer performance claims (e.g., ASTM F1670) support workflows where liquid splash resistance is a consideration.
Common Applications:
  • General controlled-environment work where a cleanroom lab coat is specified
  • Support areas, inspection steps, and non-aseptic cleanroom operations (site dependent)
  • Laboratory workflows with contamination-control expectations and splash concerns
  • Visitor or technician coverage programs where disposable garments are preferred
Best-Practice Gowning (Donning) Notes:
  • ISO-first mindset: Keep gowning inside your operations control program—training, sequencing, and behavior discipline are part of maintaining cleanroom performance.
  • Stage and inspect: Check for tears, broken snaps, or compromised cuffs before entry. Reject damaged garments.
  • Hands stay clean: Perform hand hygiene per SOP before touching the garment interior. Avoid contacting the outside surface during donning.
  • Collar and closure discipline: Fully close the snap front and seat the collar to reduce neck/chest gaps.
  • Use thumb loops correctly: Seat thumb loops and pull gloves over the cuff to maintain continuous overlap during movement.
  • Minimize adjustments: Once donned, reduce face/hair contact and unnecessary garment handling.
  • Annex 1 perspective: If you operate under EU GMP Annex 1, gowning is typically more stringent (sterile garments, higher-grade behaviors, and stricter operator control). Align garment choice to grade and risk assessment.

Selection tip: If your process requires sterile entry or aseptic operations, a non-sterile lab coat is typically not the endpoint garment. Contact SOSCleanroom for help mapping garments to ISO class, activity risk, and Annex 1 expectations.

Complementary Cleanroom Supplies:
  • Pair garment programs with compatible cleanroom gloves and a documented glove-change strategy (process dependent).
  • Support gowning-room and boundary discipline with low-lint cleanroom wipers and approved cleaning solutions for benches, pass-throughs, and staging areas.
  • For precision cleaning and validation tasks, consider cleanroom swabs for tight geometries and critical contact points.

Notes: Need help aligning cleanroom garments to ISO class, operator movement, and contamination risk? Contact SOSCleanroom for practical selection guidance.

If you need additional information please try our SOSCleanroom specific AI ChatBot which draws from our extensive cleanroom specific libraries.

Product page updated: Jan. 13, 2026 (SOS Technical Staff)

© 2026 SOS Supply. All rights reserved.

The Technical Vault
By SOSCleanroom
Kimtech™ PURE* A7 Lab Coat Medium (M) 30/Case Double Bag Low Lint (Helmke II) EN 1149-5 ASTM F1670 (Claim)
Kimtech™ PURE* A7 Lab Coat 47652 (Medium): contamination control is the garment and the donning technique
Kimtech PURE A7 Cleanroom Lab Coat 47652 Medium
SKU shown: 47652 (Medium), bulk cleanroom double-bag packaging, 30/case.
Why this entry exists

Cleanroom garments are often evaluated as a “material spec,” but contamination control outcomes depend just as much on operator behavior as the fabric. A7 lab coats can support low-lint, anti-static, splash-oriented workflows—but only when they are introduced, donned, and worn under a documented gowning program aligned to your cleanroom classification and task risk.

What this product is used for
  • Controlled-environment lab coat coverage where a disposable, low-lint garment is specified.
  • Support-area cleanroom workflows and technician/visitor coverage programs (site dependent).
  • Splash-aware processes where manufacturer listings reference barrier performance (e.g., ASTM F1670 claim).
  • Operations that benefit from bulk cleanroom packaging (double bag) at the gowning boundary.
Why customers consider A7 lab coats (manufacturer-positioned)
  • Contamination control positioning: low lint and anti-static statements support controlled-environment discipline.
  • Interface control: thumb loops and elastic cuffs help keep glove-to-sleeve overlap stable during movement.
  • Cleaner introduction: bulk cleanroom double-bag packaging reduces handling variability at entry points.
  • Coverage stability: mandarin/high collar helps reduce neck gaps that appear during motion.
Materials, composition, and build (manufacturer Product Information)

Manufacturer Product Information describes an abrasion-resistant film-coated polypropylene construction with high strength triple stitched seams, snap front, left chest pocket, mandarin collar, elastic cuffs, thumb loops, and extra-length arms.

Supplier statements also include: low lint (Helmke Drum Category II), antistatic clothing (EN 1149-5:2008), and “not made with” claims for silicone, BHT preservative, and natural rubber latex. Treat these as receiving/qualification inputs and confirm against your internal requirements.

Specifications in context (SKU 47652 — Medium)

The table below consolidates attributes most often used for gowning SOP fit, receiving checks, and day-to-day interface control. Values shown are taken from manufacturer Product Information where published.

Attribute 47652 (Medium)
Part number 47652
Garment type Cleanroom lab coat (non-sterile)
Case pack 30 / case
Packaging (listing) Bulk cleanroom packaging (double bag)
Key design elements Mandarin collar; elastic cuffs; thumb loops; snap front; chest pocket; extra-length arms; triple stitched seams
Low lint statement Low lint fabric (Helmke Drum Category II)
Anti-static statement Antistatic clothing (EN 1149-5:2008)
Barrier / splash statement (listing) ASTM F1670 pass claim (penetration of blood and body fluids)
PPE classification statement (Product Information) Certified PPE Cat II; Type 6 limited chemical splash protection (directive 89/686/EEC referenced)
Size-specific dimensions (Product Information) Chest width 60 cm; sleeve length 63 cm; total length 101 cm
Material exclusions (Product Information) Not made with silicone; not made with BHT; not made with natural rubber latex
Cleanroom gowning (donning): ISO-first guidance

ISO cleanroom performance is defined by classification and sustained by operations. A gowning program is part of an operations control program: training, entry/exit discipline, behavior controls, and garment handling are central to maintaining the intended cleanliness level.

Technique guidance: donning lab coats to minimize contamination transfer
  • Control the boundary: open the outer bag outside; introduce the inner bag per SOP to reduce boundary transfer.
  • Hands first: perform hand hygiene per SOP before touching garment interiors.
  • Don without “outside contact”: avoid contacting the outside surface during donning; treat the outer surface as “cleanroom-exposed.”
  • Close and seat: fully snap the front and seat the collar; gaps at neck/chest are common contamination pathways.
  • Lock the glove interface: use thumb loops, then pull gloves over cuffs to maintain overlap through reaching and bending.
  • Do not “shake out” during doff: remove with containment control; avoid motions that aerosolize particles.
EU GMP Annex 1 perspective (sterile medicinal products)

Under EU GMP Annex 1, gowning expectations typically become more stringent than general cleanroom practice: stricter operator behaviors, stronger emphasis on minimizing particulate and microbial contamination, and grade-appropriate garment systems. Treat a non-sterile lab coat as a lower-risk-area garment unless your quality system explicitly qualifies it for a specific grade and activity.

Common failure modes
  • Sleeve ride-up / exposed wrist: use thumb loops and glove overlap; confirm interface after movement.
  • Open collar / partial closure: fully close snaps and seat the collar; avoid “half-donned” states.
  • Boundary handling errors: control bag opening, staging, and “what touches what” at transitions.
  • Overconfidence in “low lint”: low lint reduces risk, but technique and behavior remain decisive.
Critical environment fit for this SKU

47652 (Medium) is typically selected where a disposable cleanroom lab coat is appropriate for the room classification and task risk. If your operation requires sterile garments, aseptic behaviors, or Annex 1 grade-driven controls, confirm the garment system (including sterility and packaging) through your quality system before adoption.

SOSCleanroom note about SOP's

The Technical Vault is written to help customers make informed contamination-control decisions and improve day-to-day handling technique. It is not your facility’s Standard Operating Procedure (SOP), batch record, or validation protocol.

Customers are responsible for establishing, training, and enforcing SOPs that fit their specific risks, products, equipment, cleanroom classification, and regulatory obligations. Always confirm material compatibility, cleanliness suitability, and acceptance criteria using your internal quality system and documented methods.

If you adapt any technique guidance from this entry, treat it as a starting template. Your team should review and approve the final method, then qualify it for your specific environment.

Source basis
  • SOSCleanroom product page (47652): https://www.soscleanroom.com/product/kimtech/kimberly-clark-kimtech-47652-a7-lab-coat-medium/
  • Manufacturer Product Information (Rev. 12/2017 PDF): https://exdron.co.il/Exdron-Pdf/kimberly-clark-kimtech-47652-datasheet.pdf
  • Ansell / Kimtech A7 Cleanroom Lab Coats: https://www.ansell.com/us/en/products/kimtech-a7-cleanroom-lab-coats
  • KCProfessional listing (47652): https://www.kcprofessional.com/en-us/products/scientific-and-research/cleanroom-environment/disposable-apparel/kimtech%E2%84%A2-a7-cleanroom-non-sterile-lab-coats/47652/47654
  • ISO 14644-1 (classification context): https://www.iso.org/standard/53394.html
  • ISO 14644-5 (operations / gowning program context): https://www.iso.org/standard/88599.html
  • EU GMP Annex 1 (sterile manufacturing context): https://health.ec.europa.eu/system/files/2022-08/20220825_gmp-an1_en_0.pdf
SOSCleanroom is the source for this Technical Vault entry.
Briefed and approved by the SOSCleanroom (SOS) staff.
If you have any questions please email us at Sales@SOSsupply.com
If you need additional information please try our SOSCleanroom specific AI ChatBot which draws from our extensive cleanroom specific libraries.
Last reviewed: Jan. 13, 2026
© 2026 SOSCleanroom