Ushio HBX-76 Electronic Power Supply for Short Arc Mercury and Xenon Lamps
The Ushio HBX-76 is a compact, high-performance SMARTARC® electronic power supply engineered specifically for short arc mercury and xenon DC lamps. Designed with advanced digital power management and microprocessor control, the HBX-76 ensures ultra-stable output, reliable ignition, and long lamp life in demanding scientific, industrial, and medical applications.
With wide-range AC input compatibility, built-in EMI filtering, and integrated cooling, this power supply offers a true plug-and-play solution that delivers consistent performance without external cooling requirements. Ushio’s innovative anti-aging and arc control circuits further enhance optical stability, making the HBX-76 a trusted choice for mission-critical illumination systems.
Features and Benefits
- Operates short arc Mercury and Xenon DC lamps in power ranges between 50W, 75W and 100W
- Output power is selectable by DIL 16 step switch set-up
- Power factor corrected line input, built-in EMI-Filter voltage range 90VAC to 264VAC. Meets CE and FCC Part "A"
- Built-in cooling fan - no external cooling needed
- Newly designed anti-aging and arc control circuit for high optical reliability over lamp lifetime
- Digital Power Management and micro-processor controlled with high output stability over life
- Output is short circuit protected and arc to ground protected
- 90° thermal shut-off feature
- Auto shut-off feature at end of lamp life or lamp failure
- Auxiliary regulated 12V/0.2A output for fan drive available when the lamp is in operation
Spec Sheet: SMARTARC™ HBX-76
INPUT DATA
| Nominal Operation |
Nominal |
Tolerance |
| Input Voltage AC (V) |
100 – 240 |
90 – 264 |
| Input Voltage DC (V) |
100 – 300 |
90 – 340 |
| System Wattage (W) |
123 |
60 – 120* |
| Input Current (A) |
— |
0.6 – 1.4* |
| Line Frequency (Hz) |
50/60 |
47 – 63 |
| Power Factor (1) |
1.0 |
0.93 – 1.0 |
*Depends on lamp selected. Presettable.
LAMP OUTPUT DATA
| Ignition |
Nominal |
Tolerance |
Remarks |
| Ignition Voltage (kV peak) |
±14 |
±12 – ±16 |
Load Capacity <20pF |
| Ignition Time (sec.) |
1 |
0.9 – 1.1 |
|
| Automatic Restart Counter (1) |
5 |
— |
Attempts |
| Nominal Operation |
Nominal |
Tolerance |
| Lamp Voltage (V) |
12.8 – 34 |
±5%* |
| Lamp Wattage (W) |
50, 75, 100* |
Selectable 50, 75, 100 |
| Lamp Current (A) |
— |
I Max = 7.5* |
| Cut-Off Voltage, End-Life (V) |
43 |
±2 |
| Open Circuit Voltage (V) |
45 |
45 – 48 |
*Depends on lamp selected. Presettable.
LIFETIME DATA
| |
Symbol |
Nominal |
Tolerance |
Remarks |
| Ballast Lifetime (h) |
t Life |
25,000 |
>25,000 |
acc. to MIL HDBK for nominal operation |
All values for Uu = 230 Vrms. Temperature at test point = 70°C
MISCELLANEOUS
| Nominal Operation |
Nominal |
Tolerance |
| Efficiency (1) |
0.8 |
0.75 – 0.8 |
| Ambient Temperature (°C) |
+25 |
+10 – +50 |
| Max. Temperature at Test Point (°C) |
+70 |
Case surface near output at U-profile |
| Switch Off Temperature (°C) |
+90 |
+85 – +95 |