Skip to main content

Texwipe STX761 Sterile Alpha Polyester Cleanroom Swab with Long Handle

$421.88
(No reviews yet)
SKU:
STX761
Availability:
45 BUSINESS DAY LEAD TIME
Shipping:
Calculated at Checkout
Quantity Option (Case):
10 Bags of 50 Swabs Per Case (Individually Sleeved / 500 Swabs Total)
Type:
Dry Swab
Family:
Alpha
Material:
Polyester
Sterile:
Yes

Texwipe STX761 Sterile Alpha® Polyester Knit Cleanroom Swab with Long Handle

Texwipe STX761 is a sterile, long-handle Alpha® polyester knit cleanroom swab engineered for precision cleaning and surface sampling in controlled environments where reach, repeatability, and a defensible contamination-control story matter. The cleanroom-laundered, knitted polyester head is thermally bonded (no adhesive at the head/shaft interface) to help minimize bond-line extractables variability during solvent use and to reduce fiber release pathways tied to exposed edges. STX761 is widely used for controlled cleaning and sampling of flat areas, grooves, tracks, slots, channels, tight corners, and other recessed features across industries like microelectronics, semiconductor, optics, medical devices, biologics, and pharmaceutical manufacturing. Low-linting performance is process-dependent (no swab is truly ‘lint-free’ under every surface condition and operator technique), but STX761 is built to support consistent, low-background workflows where the swab should not dominate residue, ions, endotoxin, or measurement results.

Sterile-program note: STX761 is individually sleeved with lot code and expiration dating to support audit readiness and sterile-area introductions. Sleeves are organized in sterile-friendly packaging (triple-bagged inner configuration) to reduce handling-driven variability at point of use and to help teams keep “last touch” controls consistent from operator to operator.

Specifications:
  • SKU: STX761
  • Type: Dry swab (sterile)
  • Swab family: Alpha® (polyester knit)
  • Head material: Knitted Alpha® polyester knit (double-layer knit head for absorbency and controlled wiping)
  • Handle material: Polypropylene
  • Head bond: Thermal (heat-molded / thermally bonded; no adhesive)
  • Design notes: Flexible head paddle; long handle
  • Dimensions:
    • Head width: 6.8 mm (0.268")
    • Head thickness: 2.8 mm (0.11")
    • Head length: 16.8 mm (0.661")
    • Handle width: 3.2 mm (0.126")
    • Handle thickness: 3.2 mm (0.126")
    • Handle length: 145.5 mm (5.728")
    • Total swab length: 162.3 mm (6.39")
  • Packaging configuration: 1 swab per peel-apart sleeve; 50 sleeves per inner bag/box; triple-bagged inner configuration; 10 bags/boxes per case (500 swabs total per case)
  • Sterility: Gamma-irradiated and sterile validated according to AAMI guidelines; expiration date on each sleeve; shelf life 3 years from date of manufacture
  • Cleanliness screening: Tested for endotoxins, typical ions, and typical non-volatile residue (NVR) as part of sterile swab program controls
  • Handle color: Light green; Alpha® and CleanFoam® sterile swabs use trademarked light-green handles with “TEXWIPE” embossed on the handle (practical authenticity/traceability cue; confirm by packaging label, part number, lot code, and expiration date)
  • Industries: Biologics, medical devices, microelectronics, optics, pharmaceuticals, semiconductor
  • Country of origin: Made in the Philippines; sterilized in the USA
  • Availability note: 45 business day lead time (confirm at order placement for current production timing)
About the Manufacturer: 

Texwipe (an ITW company) approaches cleanroom swabs as engineered contamination-control tools—controlling head substrate selection, bonding method (thermal bonding to eliminate adhesive contamination pathways), cleaning/laundering, and packaging discipline to fit sterile and controlled-environment workflows. For sterile programs like STX761, Texwipe emphasizes point-of-use sterility protection, lot-level traceability, and packaging intended to reduce variability in how swabs are introduced into critical zones.

 

SOSCleanroom (SOS) supports that manufacturing discipline through a working relationship focused on continuity of supply, documentation handoff (lot traceability and sterile program controls), and practical application support—so teams can standardize sterile cleanroom swabs with predictable performance and procurement reliability.

STX761 Features:
  • Thermally bonded knitted Alpha® polyester head (eliminates adhesive contamination at the bond line)
  • Cleanroom-laundered knit head intended to deliver low-background performance for critical cleaning and sampling
  • Long, rigid polypropylene handle to extend reach and help keep gloves and sleeves out of the work zone
  • Individually packaged peel-apart sleeve for point-of-use sterility protection
  • Lot coded packaging and expiration date on each sleeve for inventory control and traceability
  • Packaging system supports sterile-area introductions (triple-bagged inner configuration; case-liner protection)
  • Gamma-irradiated and sterile validated according to AAMI guidelines
  • Tested for endotoxins, ions, and non-volatile residue (NVR) as part of sterile swab program controls
  • Trademarked light-green handle with “TEXWIPE” embossed on the handle (authenticity/traceability cue; verify with label + lot code)
STX761 Benefits:
  • Sterile, point-of-use control: Individually sleeved sterile swabs with expiration dating support controlled introductions and audit narratives.
  • Lower adhesive-risk profile: Thermal bonding removes a common variable in solvent-heavy work—adhesive softening, smearing, or extractables at the head/shaft interface.
  • Reach and geometry control: Long handle and flexible head paddle improve access to recessed features while maintaining controlled contact pressure.
  • Sensitive-surface friendly: Polyester knit is soft and nonabrasive for many optics, microelectronics, and precision hardware touchpoints (confirm suitability to your surface finish and SOP).
  • Cleaner background for sampling: Often selected for surface sampling and cleaning validation workflows where neutral background contribution matters.
Common Applications:
  • Precision cleaning of grooves, tracks, slots, rails, channels, and tight corners
  • Controlled solvent use (including IPA and other compatible cleanroom solvents/solutions) for maintenance, inspection, and corrective cleaning
  • Surface sampling and cleaning validation sampling where a sterile barrier is required at point of use
  • Environmental monitoring support workflows (as defined by your site program)
  • Picking up fine powders and particulate debris in small or recessed areas
  • Cleaning broad surfaces and flat areas where a long handle improves access and reduces incidental contact risk
Best-Practice Use:
  • Sterile-open discipline: Open the peel-apart sleeve only at point of use, and avoid contact between gloves and the knit head to preserve sterile integrity.
  • Use a controlled “damp” technique: Wet the knit head to your validated method (do not flood). Controlled wetness improves residue removal without driving streaking, pooling, or solvent migration into seams and joints.
  • Stroke strategy: Use straight-line passes and avoid aggressive circular scrubbing—surface burrs + high pressure are common drivers of fiber release in real workflows.
  • Rotate and retire: Rotate to a clean face/edge as you load soils; replace the swab when the head becomes visibly soiled, tacky, or starts to leave residue.
  • Standards awareness: Align your use/qualification to your site requirements and relevant guidance (ISO: https://www.iso.org/standard/53394.html; ASTM: https://www.astm.org; IEST: https://www.iest.org; FDA: https://www.fda.gov).
Selection Notes (STX761 vs. Other Options)
  • Sterile vs. non-sterile: Choose STX761 when your workflow requires point-of-use sterility, expiration dating, and sterile-program packaging controls; use a non-sterile long-handle Alpha polyester knit swab only when sterile requirements do not apply.
  • When “background” is the gate: If you are running a cleaning validation protocol or analytical method where swab contribution must be tightly controlled (TOC/HPLC/UV-Vis/IMS), confirm whether a low-TOC or method-specific swab variant is required by your laboratory method.
  • When ESD is the gate: If electrostatic discharge control is a selection requirement (electronics/display work), specify an ESD-safe swab family in addition to the required geometry and sterility needs.

Link to Texwipe Technical Datasheet:
Click Here
Texwipe.com PDF: Click Here
Link to SOSCleanroom Blog (good information): Click Here

Notes: Need application guidance for Texwipe STX761 sterile Alpha® polyester knit cleanroom swabs with long handle—including technique tips for grooves/tracks/slots, solvent “damp” control, and documentation checkpoints (lot code, expiration, sterile packaging controls)? Open the SOSCleanroom Technical Vault tab above for practical, operator-level guidance that supports repeatable sterile swabbing in ISO-class controlled environments.

SOSCleanroom.com supports contamination-control programs with cleanroom consumables, responsive technical support, and a reliability-first supply model focused on continuity, documentation discipline, and predictable fulfillment.

Product page updated: Jan. 5, 2026 (SOS Technical Staff)
Briefed and approved by the SOSCleanroom (SOS) staff.

© 2026 SOS Supply. All rights reserved.

The Technical Vault
By SOSCleanroom
STX761 sterile long-handle swab: extended reach and controlled cleaning for aseptic environments
Last reviewed: Jan. 6, 2026 |  Audience: contamination control, aseptic processing, quality

Texwipe STX761 is a sterile polyester knit cleanroom swab designed for precision cleaning and surface sampling in aseptic environments where extended reach is required. The long handle and flexible paddle head allow controlled access into recessed areas such as channels, slots, and equipment interfaces.

The double-layer Alpha® polyester knit head supports consistent contact and controlled solvent use, while sterile packaging enables proper introduction into critical environments where maintaining barrier integrity and repeatable technique is essential.

© 2026 SOSCleanroom