Skip to main content

Texwipe TX755D Mini Thin Alpha ESD Swab

$60.94
(No reviews yet)
SKU:
TX755D BAG
Availability:
Stock Item
Shipping:
Calculated at Checkout
Quantity Option (Bag):
500 Swabs Per Bag (5 Inner Bags of 100 Swabs)
Quantity Option (Case):
50 Bags of 500 Swabs (25,000 Swabs)
Type:
Dry Swab
Swab Family:
Alpha
Swab Material:
Polyester
ESD-Safe:
Yes

Texwipe TX755D Mini Thin Alpha® ESD Swab

Texwipe TX755D is a mini thin Alpha® (polyester) ESD-safe cleanroom swab designed for precision cleaning in tight features where static control is a selection gate. Texwipe’s ESD-Safe Swab Series features a Stat-Rite® handle (a patented inherently dissipative polymer) to provide clean ESD protection without contributing particulate contaminants to the process or environment. Complete thermal-bond construction eliminates the risk of adhesive contamination, and the swabs are cleanroom processed and packaged in an anti-static bag for controlled-environment handling.

Mini-thin note: TX755D is commonly chosen when teams need a compact, controlled-contact Alpha® polyester head for recessed areas, joints, and intersecting surfaces—while keeping ESD workstation discipline intact.

Key Specs (from product listing):
  • Part No.: TX755D
  • SKU: TX755D BAG
  • Type: Dry Swab
  • Swab family: Alpha
  • Swab material: Polyester
  • ESD-safe: Yes
  • Head width: 3.7 mm (0.146")
  • Head thickness: 2.5 mm (0.098")
  • Head length: 10.5 mm (0.413")
  • Handle width: 3.0 mm (0.118")
  • Handle thickness: 3.0 mm (0.118")
  • Handle length: 64.5 mm (2.539")
  • Total swab length: 75.0 mm (2.953")
  • Packaging (Bag): 500 swabs/bag (5 inner bags of 100 swabs)
  • Packaging (Case): 50 bags/case; 25,000 swabs/case
  • Temperature note: Appropriate for use with temperatures less than 194°F / 90°C
About Texwipe + SOSCleanroom: 

ITW Texwipe is a worldwide leader in contamination-control products for critical environments, with a focus on controlled manufacturing, packaging discipline, and lot-level traceability across cleanroom consumables. For over 35 years, SOS (Specialty Optical Systems) and Texwipe have been close partners, and SOSCleanroom is the authorized Master Distributor of ITW Texwipe for the United States market.

Practically, that relationship helps customers standardize on Texwipe swabbing tools with consistent availability, responsive product support, and clean documentation handoff aligned to contamination-control and ESD program requirements.

Benefits
  • ESD protection with Stat-Rite® handle
  • No blooming carbon particles, metals, or ionic anti-static contaminants
  • Manufactured to exacting and consistent tolerances using high-precision automated processes
  • Packaged in an anti-static bag
  • Absorbs solvents, solutions, and grabs particulates
  • Lot coded for traceability and quality control
Common Applications
  • Applying and removing lubricants, adhesives, and other solutions in a critical clean environment with ESD concerns
  • Scrubbing recessed areas
  • Removal of excess materials or debris
  • Cleaning intersecting surfaces and joints
  • Cleaning with compatible solutions and solvents
  • Picking up fine powders

Documentation:
  • SOSCleanroom PDF (ESD swabs brochure): Click Here
  • Texwipe.com PDF (ESD-Safe Swabs TDS): Click Here

*Stat-Rite® is a trademark of Lubrizol Advanced Materials, Inc.

The Technical Vault By SOSCleanroom
ISO 14644 Operations Awareness ESD Workstation Discipline Mini-Thin Access Control Solvent Control (Damp-Film) Residue & Rework Reduction

Texwipe TX755D: what this Mini Thin Alpha® ESD swab is designed to solve

Texwipe TX755D is a mini thin Alpha® (polyester) ESD-safe cleanroom swab designed for precision cleaning in recessed areas, intersecting surfaces, and joints where access is tight and ESD discipline is a selection gate. The “mini thin” geometry supports controlled contact in narrow features, reducing the risk of over-wetting, smear, and redeposit that typically drive rework in defect-sensitive workflows.

Texwipe’s ESD-Safe Swab Series features a Stat-Rite® handle (a patented inherently dissipative polymer) to provide clean ESD protection without contributing particulate contaminants to the process or environment. The complete thermal bond construction eliminates adhesive contamination risk. TX755D is cleanroom processed and packaged in an anti-static bag to support controlled-environment handling.

Operations takeaway: Treat TX755D as a method-control tool. Lock the wetness target, stroke pattern, pressure band, and change-out triggers to reduce operator-to-operator variation at ESD-controlled workstations.


ISO-first context: why swabbing belongs in operations control

In ISO-controlled environments, swabbing is an operator-defined method—wetness, pressure, direction changes, and change-out timing materially affect outcomes. If the process is residue-sensitive, defect-sensitive, or ESD-controlled, write the TX755D method as part of operations control: introduction rules, ESD workstation rules, technique, change-out, and disposal.

Control point: Most “visible cleaning defects” come from uncontrolled wetness and re-wiping with a loaded swab—standardize the method for repeatability.


Specifications (use for RFQs, SOPs, and receiving controls)
  • Part No.: TX755D
  • Type: Dry Swab
  • Swab family: Alpha
  • Swab material: Polyester
  • ESD-safe: Yes (Stat-Rite® handle; inherently dissipative polymer)
  • Head width: 3.7 mm (0.146")
  • Head thickness: 2.5 mm (0.098")
  • Head length: 10.5 mm (0.413")
  • Handle width & thickness: 3.0 mm (0.118")
  • Handle length: 64.5 mm (2.539")
  • Total swab length: 75.0 mm (2.953")
  • Head bond: Complete thermal bond (eliminates adhesive contamination risk)
  • Packaging (Bag): 500 swabs/bag (5 inner bags of 100 swabs)
  • Packaging (Case): 50 bags/case; total 25,000 swabs/case
  • Temperature note: Appropriate for use with temperatures less than 194°F / 90°C

*Stat-Rite® is a trademark of Lubrizol Advanced Materials, Inc.


What TX755D is designed to do (process outcomes)

TX755D is commonly selected for:

  • Applying and removing lubricants, adhesives, and other solutions in a critical clean environment with ESD concerns
  • Scrubbing recessed areas
  • Removal of excess materials or debris
  • Cleaning intersecting surfaces and joints
  • Cleaning with compatible solutions and solvents
  • Picking up fine powders

Precision-cleaning note: Keep wetness controlled (“damp film,” not dripping), avoid backtracking with a loaded swab, and define feature limits per swab to prevent redeposit.


Best-practice use (reduce residue, rework, and changeovers)
  1. Open-and-use discipline: open the anti-static bag only when ready; remove one swab at a time; reseal promptly.
  2. Handle-only rule: touch only the handle; keep the tip isolated from gloves, benches, cartons, and tools.
  3. Damp, not flooded: if using solvent/solution, target a controlled damp film to avoid migration into seams and interfaces.
  4. Directional strokes: use straight-line passes; avoid scrubbing that redistributes dissolved soils.
  5. Rotate contact faces: use a clean contact patch for each pass; do not re-wipe with a loaded head.
  6. Define change-out triggers: replace when it loads, becomes tacky, loses structure, or leaves visible streaks.
  7. Temperature guardrail: keep use below 194°F / 90°C.

Troubleshooting (most common failure modes)
  • Streaks / tide marks: usually over-wetting or re-wiping with a loaded swab. Reduce wetness and change out sooner.
  • Haze after drying: redeposit of dissolved contamination. Avoid backtracking and solvent pooling.
  • Particles after “cleaning”: tip touched glove/bench/carton edge or pressure dislodged material. Tighten handling and reduce force.
  • Shift-to-shift inconsistency: method drift. Lock wetness target, stroke count, feature limit per swab, and change-out triggers.

Selection notes (TX755D vs. other ESD options)

Choose TX755D when you need an Alpha® polyester ESD swab with a compact, controlled-contact head for tight geometries. If the method requires a different head behavior (foam vs. knit vs. absorbent nonwoven) or a pick tool, select the correct substrate/tool first, then qualify the technique.

Change-control reminder: Switching between ESD and non-ESD tools (or between foam/knit/nonwoven behaviors) should be treated as a controlled change in validated or defect-sensitive processes.


Suggested glove pairing (operator contamination control)

In controlled environments, glove selection is a meaningful contamination-control variable. For residue-sensitive and particle-sensitive work, use cleanroom processed gloves appropriate to the ISO class and aligned to ESD workstation rules at point-of-use.

Suggested pairing: Ansell 93-311 Nitrilite® Cleanroom Nitrile Gloves (Class 100 / ISO 5)

  • Supports low particulate transfer expectations for precision cleaning tasks
  • Maintains tactile control for controlled pressure bands in tight features

Final glove selection should be validated against internal SOPs, environmental classification, and ESD program requirements.


Documentation (use current manufacturer data for controlled programs)
  • SOSCleanroom TX755D Product Page: Click Here
  • ESD-Safe Swabs Brochure (SOS PDF): Click Here
  • Texwipe ESD-Safe Swabs TDS (Texwipe PDF): Click Here
  • Texwipe Swab Sampling Proper Procedure (SOS PDF): Click Here
  • Texwipe Swabbing Guide (SOS PDF): Click Here

*Stat-Rite® is a trademark of Lubrizol Advanced Materials, Inc.


Why source ITW Texwipe TX755D through SOSCleanroom
  • Configuration control: you get the correct SKU and case pack tied to the item—reducing “equivalent swab” substitutions.
  • Master Distributor support: SOSCleanroom is an authorized ITW Texwipe Master Distributor—supporting correct ESD-series selection and continuity planning.
  • Documentation routing: help locating current manufacturer documentation required by your SOP (brochures/TDS and method guidance).
  • One-cart procurement: pair ESD swabs with compatible gloves, wipers, and cleaning chemistries to keep method control consistent.

Procurement control point: For validated or defect-sensitive processes, specify “no substitution without written approval” on RFQs/POs and define receiving/lot capture expectations.


Related products (commonly purchased together)
  • TX754E (Mini Alpha® ESD option)
  • TX750E (Mini compressed CleanFoam® ESD option)
  • TX750D (Mini compressed CleanFoam® ESD option)
  • TX758E (Micro Alpha® ESD option)
  • TX753E (Mini CleanFoam® ESD option)

If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.