QRP Qualatex® 7C Anti-Static Cleanroom Latex Finger Cots (Pink) — ISO 5 / Class 100 Packaged, Class II ESD Use Case, Static Dissipative (Avg. 1010 Ω/□), Powder-Free, 3.5 mil, 2.75" Length, Stand-Up Pack
ISO 5 / Class 100 packaged Class II ESD use case Anti-static / static dissipative Natural latex (pink) Powder-free Textured tip 5 gross (720) / pack 20 packs / case (14,400)

Overview

QRP Qualatex® 7C finger cots are designed for precision handling where you want fingertip coverage without the bulk of a full glove. They are packaged for ISO 5 (Class 100) applications and are intended for ESD-sensitive work where electrostatic control and particulate discipline both matter at the point of touch.

Use finger cots to control skin oils/salts and reduce transfer risk during micro-assembly, inspection, and controlled handling tasks—especially when product contact is localized to fingertips. (For industrial use only.)


Why this finger cot matters in controlled environments
  • ESD control at the fingertip: published average surface resistance of 1010 Ω/□ supports static-dissipative handling expectations.
  • ISO 5 packaging: supports cleaner staging/dispensing versus general-purpose finger cots.
  • Powder-free + textured tip: helps reduce residue transfer and improves handling confidence during detailed work.
  • Clear use-case guidance: designed for Class II static sensitive devices (thresholds above 1000 V), helping teams standardize PPE selection in ESD programs.

Typical tasks supported (published examples)
  • ESD-sensitive areas and repair/assembly stations
  • Defense and avionics handling
  • Marine electronics and consumer electronics work
  • IC industries and wire bonding tasks
  • Precision inspection and controlled component handling

Key specifications (published)
Product ID / SKU 7C
Cleanroom packaging Packaged for Class 100 (ISO 5 / M3.5) applications
Material / color Natural rubber latex (biodegradable); pink
ESD / resistance (average) Average surface resistance 1010 Ω/□
ESD program reference ESD safe compliance to ANSI/ESD S20.20-2014 (as stated)
Use case (published guidance) For use with Class II static sensitive devices (thresholds above 1000 V)
Thickness / length 3.5 mil; 2.75 in (70 mm)
Finish Rolled finger cots; textured tip; powder coating: none
Available sizes S, M, L, XL
Country of origin (published) Vietnam
Packaging (published) Pack: 5 gross (720) per pack; Case: 20 packs per case (14,400 total)
Important latex notice

Caution: this product contains natural rubber latex, which may cause allergic reactions. If your facility maintains latex restrictions, select a nitrile finger cot alternative.


Packaging and handling (controlled dispensing)

The 7C is supplied in a stand-up pack to support product identification and controlled dispensing at the workstation. Maintain pack integrity until point of use and dispense using clean technique to protect ISO-packaged contents.

Case configuration is published as 20 packs per case, with 5 gross (720) per pack (14,400 finger cots total).


EU GMP Annex 1 alignment notes (practical)

Annex 1 programs manage the operator interface through a documented Contamination Control Strategy (CCS). Finger cots can support precision handling and ESD control, but they typically do not replace validated sterile glove systems used for Grade A/B aseptic operations.

  • Use-case clarity: confirm whether the task is aseptic/sterile or ESD/particle-sensitive and select PPE accordingly.
  • Change triggers: define tear/snag, uncontrolled contact, task breaks, and time-based changes; train for rapid, controlled replacement.
  • Change control: treat PPE substitutions as change-controlled events to prevent process drift.

Storage and lifecycle control
  • Store in a cool, dry location, away from sources of light; avoid extremes of heat or cold.
  • Published storage range: 50°F – 86°F (10°C – 30°C).
  • Use FIFO and maintain lot traceability aligned to your ESD and quality program requirements.

Standards and regulatory references (where applicable)

Documentation

Use these documents for ESD program files, qualification packets, and change-control reviews.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.
The Technical Vault By SOSCleanroom
ISO-first touch discipline Class II ESD handling Workstation dispensing control Annex 1 practical notes

Finger cots vs. gloves: selecting the right control

Finger cots are a precision control when product contact is concentrated at the fingertips and a full glove adds bulk, reduces dexterity, or increases accidental contact. The operational goal is to manage skin oil/salt transfer and reduce uncontrolled touch events without slowing the process.

Key rule

If the hazard requires full-hand protection (chemicals, powders, bio-risk, sharps, or validated sterile barrier systems), move to the correct glove system per EHS/QA requirements.


ESD control: why the finger cot must be part of a system
  • Class II device context: QRP 7C is positioned for Class II static sensitive devices (thresholds above 1000 V), which helps standardize PPE selection for higher-voltage threshold components.
  • Program beats product: finger cots work best inside an ESD Control Program (grounding, work surfaces, tools, ionization, training, audits).
  • Behavior is the control: the cleanest consumable can be defeated by uncontrolled touching of pouches, benches, or non-controlled packaging.

ISO-first handling: dispensing and donning without recontamination
  1. Start clean and dry: wet skin increases snag risk and reduces fit control.
  2. Stage correctly: keep the outer pack on the correct side of your gowning/bench line per SOP.
  3. Dispense with clean technique: avoid touching the interior of the pack and avoid “digging” through product.
  4. Don from the rolled edge: roll down smoothly; overstretching the tip is a common failure mode.
  5. Change triggers: tear/snag, loss of fit, uncontrolled contact, task breaks, and any time-based change rule defined by SOP.

Latex control note (facility policy and worker safety)

QRP 7C finger cots contain natural rubber latex. If your facility has latex restrictions or an allergy risk management program, use a nitrile finger cot alternative to avoid introducing latex into the area.


ISO-first, then Annex 1: where finger cots fit

Annex 1 environments manage contamination risk through a Contamination Control Strategy (CCS). Finger cots can support precision handling and ESD control, but they generally do not replace validated sterile glove systems used for Grade A/B aseptic operations.

  • Do not “swap in”: treat PPE substitutions as change-controlled events.
  • Document change triggers: define when finger cots must be changed to prevent process drift.
  • Escalate when required: if the process requires full barrier coverage, move to the appropriate cleanroom glove system per CCS/SOP.

Recommended pairings (reduce touch-point risk)
  • ESD-safe micro-cleaning: keep ESD-safe pick swabs available for component recovery and micro-detail cleaning.
  • Cleanroom wipers: wipe tools and workstation touchpoints per SOP to reduce recontamination and residue transfer.
  • Latex-restricted areas: use nitrile finger cots to avoid introducing latex into controlled work zones.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.