3M / Neogen Sponge-Stick SSL10NB2G — Sponge-stick with 10 mL Neutralizing Buffer + gloves for controlled surface sampling
Environmental surface sampling, sanitizer carryover control, 1.5" x 3" biocide-free cellulose, stick access for drains/pipes/equipment, includes gloves + 5" x 9" sample bag
Overview
The 3M / Neogen Sponge-Stick SSL10NB2G is a sponge-on-a-stick sampling device built for efficient, controlled environmental surface sampling—especially in hard-to-reach areas like drains, pipes, and around equipment. The 1.5" x 3" biocide-free cellulose sponge is mounted to a handle and pre-hydrated with 10 mL Neutralizing Buffer diluent to support sampling when residual sanitizers or disinfectants could impact recovery.

Why it matters (neutralization + safer access)
  • Neutralizer-aware sampling: Pre-hydration with Neutralizing Buffer diluent helps reduce the risk that residual chemistry suppresses organism recovery (use per SOP/method).
  • Reduced handling variability: The stick allows collection without directly handling the sponge and helps avoid touching the inside of the bag—supporting sample integrity.
  • Designed for hard-to-reach zones: Ideal for reaching into drains, pipes, and equipment interfaces where swabs and flat sponges are inefficient.
  • Complete kit convenience: Includes gloves and a sample bag to support consistent execution and transport to the lab.

What’s included (published)
  • SKU / Model: SSL10NB2G
  • Sponge: 1.5" x 3" biocide-free cellulose sponge mounted on a stick; pre-hydrated with Neutralizing Buffer diluent
  • Hydration volume: 10 mL Neutralizing Buffer diluent
  • Gloves: Two universal-fit polyethylene gloves (included)
  • Sample bag: 5" x 9" sample bag with 18 oz / 0.53 L capacity (included)
  • Case pack: 100 Sponge-Sticks (with Gloves) per case
Note: Align sampling locations, surface area, technique, hold times, and transport conditions to your site SOP and validated laboratory method.

Key features and benefits (published)
  • Stick access + thumb-stop: Helps reduce direct contact with the sponge and supports consistent technique in tight spaces.
  • Snap-free sponge design: Once placed inside the bag, the sponge snaps free from the handle for easier handling and transportation.
  • Biocide-free sponge: Designed not to affect organism viability.
  • Gamma irradiated: Decontaminated through gamma irradiation to help maintain aseptic conditions.
  • Dry-only flexibility note: The listing indicates the 1.5" x 3" dry sponge can be used with a wide range of buffers/enrichment media and in dry-only environments.

Quick specs (published)
SKU / Model SSL10NB2G
Sampling format Sponge mounted on stick; pre-hydrated
Sponge size 1.5" x 3"
Buffer / volume Neutralizing Buffer diluent, 10 mL
Bag size / capacity 5" x 9"; 18 oz / 0.53 L capacity
Case pack 100 Sponge-Sticks (with Gloves) per case

Recommended pairings (common workflow add-ons)
  • Flat surface coverage: Pair sponge-sticks for drains/crevices with hydrated sponges for broad, flat equipment panels and tables.
  • Verification layering: Use rapid hygiene verification (where appropriate) alongside microbiological EM to improve response speed and trending confidence.
  • Controlled-area housekeeping: Support adjacent controlled zones (QA labs, weigh rooms, controlled staging) with Texwipe cleanroom wipers and validated cleaning tools to reduce recontamination risk.
If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214) 340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries — give it a try! THIS IS NEW FOR 2026!
© 2026 SOSCleanroom. All rights reserved.
The Technical Vault By SOSCleanroom
Environmental Monitoring Neutralizer-Aware Sampling Hard-to-Reach Areas Chain-of-Custody

Why sponge-sticks are a critical tool for “infrastructure” sampling
Many sanitation programs over-sample easy surfaces and under-sample the places that drive recurring positives: drains, pipe penetrations, equipment framework interfaces, and moisture-trapping geometries. A sponge-stick addresses this gap by giving the operator reach and leverage without directly handling the sponge. For SSL10NB2G, the stick helps collect a sample while minimizing contact with the bag interior and includes a thumb-stop to reduce inadvertent sponge contact—both of which support more consistent execution.

Neutralizing buffer: your EM data is only as “true” as your recovery
Effective cleaning and disinfection is non-negotiable—but residual sanitizer chemistry can suppress organism recovery at the moment of collection. A pre-hydrated sponge-stick with 10 mL Neutralizing Buffer diluent is a practical control to help reduce that carryover effect (always per your validated method and SOP). Operationally, the benefit is trend integrity: results reflect the environment more accurately rather than the last chemical application.

ISO-first sampling discipline: standardize the variables that create defendable trends
  • Location control: Define exact locations (drain ID, pipe segment, machine station, framework joint) and stick to them for trending.
  • Area/contact control: Define the contact zone and dwell/coverage expectations so sampling is repeatable.
  • Technique control: Standardize strokes, pressure, and “do-not-touch” rules for bag interior and glove-to-sponge contact points.
  • Timing control: Sample at consistent timepoints (post-clean, pre-start, mid-run, end-of-run) so results are comparable.

Chain-of-custody checklist: make the result actionable
  • Labeling: Sample ID, date/time, operator, site/line/zone, exact location, and test request.
  • Condition notes: Record wet/dry status, visible residues, and any deviations from SOP.
  • Transport controls: Document time-to-lab and any temperature requirements defined by your method.
  • Response plan: Link excursions to defined actions (re-clean, resample, investigation, CAPA, retraining) and verify effectiveness.
Published configuration (SSL10NB2G): 100 Sponge-Sticks (with Gloves) per case; 1.5" x 3" biocide-free cellulose sponge mounted on a stick; pre-hydrated with 10 mL Neutralizing Buffer diluent; includes two universal-fit polyethylene gloves; includes a 5" x 9" sample bag with 18 oz / 0.53 L capacity; decontaminated through gamma irradiation.
Need help selecting the right Neogen sampling format (sponge-stick vs. sponge; neutralizing vs. other media) for your program? Email Sales@SOSsupply.com or call (214) 340-8574.