Skip to main content

Texwipe TX759E Micro Absorbond ESD Swab

$100.23
(No reviews yet)
SKU:
TX759E BAG
Availability:
Stock Item
Shipping:
Calculated at Checkout
Quantity Option (Bag):
500 Swabs Per Bag (5 Inner Bags of 100 Swabs)
Quantity Option (Case):
5 Bags of 500 Swabs (2,500 Swabs)
Type:
Dry Swab
Swab Family:
Alpha
Swab Material:
Polyester
ESD-Safe:
Yes

Texwipe TX759E Micro Absorbond® ESD Swab

Texwipe TX759E is an ESD-safe Micro Absorbond® swab built for precision cleaning in very small grooved, slotted, and recessed areas where static control is a selection gate. It features a Stat-Rite® inherently dissipative polymer handle designed to provide clean, permanent ESD protection without contributing particulate contaminants to the process or environment. The complete thermal bond construction eliminates the risk of adhesive contamination, and the swab is cleanroom processed and packaged in an anti-static bag for controlled-environment handling.

Use-case note: TX759E is commonly chosen when the task requires controlled absorption (solvents/solutions) plus particulate pickup in tight features—without sacrificing ESD discipline.

Key Specs (from product listing):
  • Part No.: TX759E
  • Type: Dry swab
  • Swab material: Polyester (Micro Absorbond® head)
  • ESD-safe: Yes (Stat-Rite® handle)
  • Head width: 4.0 mm (0.157")
  • Head thickness: 2.6 mm (0.102")
  • Head length: 10.0 mm (0.394")
  • Handle width: 3.0 mm (0.118")
  • Handle thickness: 3.0 mm (0.118")
  • Handle length: 80.5 mm (3.169")
  • Total swab length: 90.5 mm (3.563")
  • Packaging (Bag): 500 swabs/bag (5 inner bags of 100 swabs)
  • Packaging (Case): 5 bags/case; total 2,500 swabs/case
  • Packaging note: Packaged in an anti-static bag
  • Temperature note: Appropriate for use with temperatures less than 194°F / 90°C
About Texwipe + SOSCleanroom: 

ITW Texwipe is a worldwide leader in contamination-control products for critical environments, with a focus on controlled manufacturing, packaging discipline, and lot-level traceability across cleanroom consumables. For over 35 years, SOS (Specialty Optical Systems) and Texwipe have been close partners, and SOSCleanroom is the authorized Master Distributor of ITW Texwipe for the United States market.

Practically, that relationship helps customers standardize on Texwipe swabbing tools with consistent availability, responsive product support, and clean documentation handoff aligned to contamination-control and ESD program requirements.

Features
  • ESD protection with Stat-Rite® handle
  • No blooming carbon particles, metals, or ionic anti-static contaminants (per product listing claim)
  • Complete thermal bond construction eliminates the risk of adhesive contamination
  • Cleanroom processed and packaged in an anti-static bag
  • Manufactured to exacting and consistent tolerances using high-precision automated processes
  • Absorbs solvents/solutions and grabs particulates
  • Lot coded for traceability and quality control
Common Applications
  • Applying and removing lubricants, adhesives, and other solutions in a critical clean environment with ESD concerns
  • Scrubbing recessed areas
  • Removal of excess materials or debris
  • Cleaning intersecting surfaces and joints
  • Cleaning with compatible solutions and solvents
  • Picking up fine powders

Documentation:
  • SOSCleanroom PDF (ESD swabs brochure): Click Here
  • Texwipe.com PDF (ESD-Safe Swabs TDS): Click Here

*Stat-Rite® is a trademark of Lubrizol Advanced Materials, Inc.

The Technical Vault By SOSCleanroom
ISO 14644 Operations Awareness ESD Workstation Discipline Precision Micro-Feature Cleaning Solvent Control (Damp-Film) Residue & Rework Reduction

Texwipe TX759E: what this Micro Absorbond® ESD swab is designed to solve

Texwipe TX759E is a Micro Absorbond® ESD-safe cleanroom swab selected for precision cleaning in tight geometries where “small format + controlled absorption + ESD discipline” is the requirement. It is used to apply and remove small, controlled amounts of compatible solutions/solvents while also lifting particulates in recessed areas, intersecting surfaces, joints, grooves, and other micro-features that demand repeatable technique.

Per the manufacturer description, Texwipe’s ESD-Safe Swab Series uses a Stat-Rite® handle (inherently dissipative polymer) to provide clean ESD protection without contributing particulate contaminants to the process or environment. The swab is built with complete thermal bond construction to eliminate adhesive contamination risk, and it is cleanroom processed and packaged in an anti-static bag.

Operations takeaway: TX759E is a method-control tool. When you lock the wetness target, stroke pattern, pressure band, feature limit per swab, and change-out triggers, you reduce redeposit and shift-to-shift variability in ESD-controlled cleaning steps.


ISO-first context: why micro-swabbing belongs in operations control

In ISO-controlled environments, micro-swabbing is not “just a consumable.” It is a defined method with operator-driven variables (wetness, contact pressure, stroke direction, dwell time, and change-out timing). If your process is defect-sensitive, residue-sensitive, or ESD-controlled, write and train the swab method as an operations control: introduction rules, ESD workstation rules, technique, change-out criteria, and disposal.

Control point: Two operators using the same swab can create different outcomes if wetness and backtracking are inconsistent. Standardize the method for repeatability.


Specifications (use for RFQs, SOPs, and receiving controls)
  • Part No.: TX759E
  • Series: ESD-Safe Swab Series (Stat-Rite® handle)
  • Head width: 4.0 mm (0.157")
  • Head thickness: 2.6 mm (0.102")
  • Head length: 10.0 mm (0.394")
  • Handle width: 3.0 mm (0.118")
  • Handle thickness: 3.0 mm (0.118")
  • Handle length: 80.5 mm (3.169")
  • Total swab length: 90.5 mm (3.563")
  • Construction: Complete thermal bond (eliminates adhesive contamination risk)
  • Packaging: 500 swabs/bag (5 inner bags of 100); 5 bags/case; total 2,500 swabs/case
  • Packaging note: Packaged in an anti-static bag
  • Traceability: Lot coded for traceability and quality control (capture lot per your SOP)
  • Temperature note: Appropriate for use with temperatures less than 194°F / 90°C

What TX759E is designed to do (process outcomes)

TX759E is commonly selected for:

  • Applying and removing lubricants, adhesives, and other solutions in a critical clean environment with ESD concerns
  • Scrubbing recessed areas and cleaning intersecting surfaces/joints
  • Removal of excess materials or debris in tight features
  • Cleaning with compatible solutions and solvents using controlled wetness
  • Picking up fine powders

Precision-cleaning note: In micro-features, the biggest failure mode is redeposit from over-wetting and backtracking. Control wetness and change-out timing before changing the swab.


Best-practice use (reduce residue, rework, and changeovers)
  1. Open-and-use discipline: open the anti-static bag only when ready; remove one swab at a time; reseal promptly.
  2. Handle-only rule: touch only the handle; keep the tip isolated from gloves, benches, cartons, and tools.
  3. Damp, not flooded: if using solvent/solution, target a controlled damp film (no dripping) to avoid solvent migration into seams/interfaces.
  4. Directional strokes: use straight-line passes; avoid scrubbing that redistributes dissolved soils and creates haze/tide marks.
  5. Rotate contact faces: use a clean contact patch for each pass; do not re-wipe with a loaded head.
  6. Plan change-out triggers: replace when the head loads, becomes tacky, deforms, or begins to leave streaking/visible residue.
  7. ESD discipline: treat the swab as part of the ESD system—do not introduce non-qualified tools/packaging into the workstation.

Two-pass discipline (when needed): one damp swab to mobilize contamination, followed by a second swab to pick up dissolved soils before they dry into a film. This is a common control for residue-sensitive work.


Troubleshooting (most common failure modes)
  • Streaks / tide marks: usually over-wetting or backtracking. Correct with damp film control and earlier change-out.
  • Haze after drying: redeposit of dissolved contamination. Reduce pooling in seams and eliminate re-wiping with a loaded head.
  • Particles after “cleaning”: tip touched glove/gown/bench or too much pressure dislodged material. Tighten handling and reduce pressure.
  • Shift-to-shift inconsistency: method drift. Lock wetness target, stroke count, feature limit per swab, and change-out triggers.

Selection notes (TX759E vs. related options)

Choose TX759E when you need Micro Absorbond® performance and ESD-safe handling at point-of-use. If your method requires a different head behavior, pick the head substrate first, then qualify the technique.

  • Non-ESD Absorbond: if ESD is not required, consider TX759B.
  • ESD micro foam: consider TX757E when a foam head behavior is preferred.
  • ESD micro knit polyester: consider TX758E when knit polyester performance is the selection gate.
  • Micro pick tool: consider TX768D when the work is “pick + lift + remove” rather than absorbent wipe action.

Change-control reminder: Switching between ESD and non-ESD tools, or between foam/knit/nonwoven behaviors, should be treated as a controlled change when the process is validated or defect-sensitive.


Suggested glove pairing (operator contamination control)

When using micro swabs in controlled environments, gloves are a meaningful contamination-control variable. For residue-sensitive and particle-sensitive work, use cleanroom processed gloves appropriate to the ISO class and the ESD workstation rules at point-of-use.

Suggested pairing: Ansell 93-311 Nitrilite® Cleanroom Nitrile Gloves (Class 100 / ISO 5)

  • Supports low particulate / low extractable transfer expectations for precision cleaning tasks
  • Maintains tactile control for micro-feature technique and controlled pressure bands

Final glove selection should be validated against internal SOPs, environmental classification, and ESD program requirements.


Documentation (use current manufacturer data for controlled programs)
  • SOSCleanroom TX759E Product Page: Click Here
  • ESD-Safe Swabs Brochure (SOS PDF): Click Here
  • Texwipe ESD-Safe Swabs TDS (Texwipe PDF): Click Here
  • Texwipe Swab Sampling Proper Procedure (SOS PDF): Click Here
  • Texwipe Swabbing Guide (SOS PDF): Click Here

*Stat-Rite® is a trademark of Lubrizol Advanced Materials, Inc.


Why source ITW Texwipe TX759E through SOSCleanroom
  • Configuration control: the correct SKU and case pack tied to the item—reducing “equivalent swab” substitutions.
  • Master Distributor support: SOSCleanroom is an authorized ITW Texwipe Master Distributor—supporting correct ESD-series selection and continuity planning.
  • Documentation routing: help locating current manufacturer documentation required by your SOP (brochures/TDS and method guidance).
  • One-cart procurement: pair ESD swabs with compatible gloves, wipers, and cleaning chemistries to keep method control consistent.

Procurement control point: For validated or defect-sensitive processes, specify “no substitution without written approval” on RFQs/POs and define receiving/lot capture expectations.


Related products (commonly purchased together)
  • TX759B (Micro Absorbond® non-ESD option)
  • TX757E (Micro CleanFoam® ESD option)
  • TX758E (Micro Alpha® ESD option)
  • TX768D (Micro Pick ESD tool for pick/lift removal)

If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.