Skip to main content

Texwipe TX5740 TexWrite 8.5" x 11" White Spiral Notebook for Cleanrooms

$214.44
(No reviews yet)
SKU:
TX5740
Availability:
7-10 Business Days
Shipping:
Calculated at Checkout
Quantity Option (Case):
10 Notebooks Per Case
Texwipe TX5740 TexWrite® Cleanroom Spiral Notebook — 8.5" x 11", White, College-Ruled
TX5740 is a spiral-bound cleanroom notebook for technician note-taking, batch/lot recording, equipment logs, and controlled-environment data capture. It uses TexWrite® 22 cleanroom bond pages printed with IPA-resistant, low-sodium ink to help reduce ionic contamination risk during routine documentation.

For over 35 years, SOS and Texwipe have been close partners, and SOSCleanroom is the authorized Master Distributor of ITW Texwipe for the United States market. That relationship matters when you are standardizing cleanroom stationery: it supports continuity of supply, stable product lineage, and fast access to the manufacturer documentation your QA/QC team expects.

Published configuration (TX5740)
  • Notebook size: 8.5" x 11" (216 mm x 279 mm)
  • Pages: 100 writable pages (50 sheets)
  • Ruling: White, college-ruled
  • Paper: TexWrite® 22 cleanroom bond (latex-impregnated cleanroom paper)
  • Cover: High-density polyethylene (HDPE), chemical-resistant cover material
  • Binding: Plastic spiral; notebook lies flat and pages rotate freely
  • Ink: IPA-resistant, low-sodium ink (reduced ionic contamination)
  • Packaging: 10 notebooks per box (case); cleanroom packaged
  • Cleanroom environment: ISO Class 3–8 (Class 1–100,000); EU Grade A–D
  • Autoclave: Autoclaving is not recommended
Low particle and fiber generation — and the reality check
This notebook is designed for ultraclean handling with low particle and fiber generation. Even so, no paper product is truly “lint-free.” Treat stationery like a contamination-controlled component: control when it is opened, how it is transported, and what touches the pages.

Practical cleanroom use guidance (technicians and engineers)
  • Open/close discipline: Open slowly and keep it closed when not in use to reduce “air pumping” that can mobilize particles.
  • Segregate the work zone: Keep the notebook off critical surfaces; do not lay open pages on benches where residues or particles can transfer.
  • Glove control: Avoid wet gloves and solvent-wet fingertips. Solvent on gloves is one of the fastest ways to create smearing, transfer, and page edge degradation.
  • Page handling: Minimize aggressive page flipping near product or open assemblies. Rotate pages deliberately and avoid dragging sleeves across the writing area.

Compatibility and wipe-down notes
  • IPA exposure: Pages are printed with IPA-resistant ink, and the HDPE cover is a chemical-resistant material. If your SOP permits, this supports typical external wipe-down practices.
  • Do not autoclave: Autoclaving is not recommended for this notebook. Use sterile documentation products that are explicitly rated for autoclave cycles when required by the program.
  • DI water / aqueous wipe-down: Not published for this notebook. If your site requires aqueous wipe-down, qualify the notebook under your conditions before standardizing.
  • Wipe-down technique: Wipe the closed cover first, avoid saturating page edges, and allow full dry time before opening to reduce ink transfer and residue.

Typical performance characteristics 
These are published as typical analyses (not specifications) to support qualification planning and contamination-risk reviews.
Property Typical value Test method (as published)
Basis weight 80 g/m² TM2
Caliper 5.0 mil (Not stated)
Tensile strength (machine direction) 5.3 kg Federal Standard No. 191A: Methods 5102
Tensile strength (cross direction) 4.5 kg Federal Standard No. 191A: Methods 5102
Tear strength (machine direction) 78 g Elmendorf tear test
Tear strength (cross direction) 79 g Elmendorf tear test
Opacity 74% TAPPI T-425
Surface resistivity (55% RH) 2.6 x 109 ohms (also shown as 2.6 x 1010 ohms/sq) TM14 (adapted from EOS/ESD-S11.11-1993)

Typical contamination characteristics 
Property Typical value Test method (as published)
Particles (>0.5 µm) 4.8 million particles/m² TM5
Sodium 85 ppm TM12 (CIA)
Chloride 50 ppm TM12 (CIA)

Common failure modes 
  • Smearing / ink transfer: Usually from solvent contact before dry time, wet gloves, or closing pages too quickly. Prevent with dry-time discipline and glove moisture control.
  • Paper dusting / abrasion: Triggered by high writing pressure, scraping tools, or aggressive erasing. Prevent with controlled writing pressure and SOP correction practices (strike-through/initial if applicable).
  • Residue carryover: Transfer from benches, sleeves, or contaminated gloves. Prevent by keeping pages off work surfaces and maintaining “documentation-only” handling.
  • Static attraction: In low humidity, stationery can attract fines. Prevent by following site ESD controls and avoiding rubbing covers against garments.

Storage and handling best practices
  • Keep notebooks in original cleanroom packaging until introduced into the controlled area.
  • Store closed to reduce particle deposition on pages; transport in a clean pouch or drawer when possible.
  • Avoid stacking with abrasive tools or clips that can scuff the cover and generate debris.
  • Control exposure to wet chemicals; do not allow page edges to wick solvent.
Documentation 
SOS-hosted Texwipe datasheet (DS-5740, Effective: December 2009): Click Here
Texwipe manufacturer page (TX5740): Click Here
If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574.

Check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try!
 
THIS IS NEW FOR 2026!

© 2026 SOS Supply. All rights reserved.
The Technical Vault
By SOSCleanroom
IPA-resistant, low-sodium ink
Cleanroom packaged
Made in USA (per Texwipe TDS)
Texwipe TexWrite TX5740 cleanroom spiral notebook: 8.5" x 11" white, college-ruled documentation for controlled environments
Texwipe TX5740 TexWrite 8.5 x 11 white cleanroom spiral notebook
Product image shown from the SOSCleanroom listing.
1) Practical solutions in a critical environment

In cleanrooms and other controlled environments, documentation is part of contamination control. A notebook that sheds fibers, smears ink, or transfers residue can turn routine note-taking into a particle or rework event. TX5740 is designed for day-to-day documentation where you need legible, repeatable writing without introducing the common stationery failure signatures: paper dust, ink flake, smearing, cover abrasion, and loose binding debris.

Typical use cases include maintenance logs at gowning/airlocks, equipment cleaning sign-offs, engineering change notes, batch record support notes, and controlled “traveler” annotations where supervisors need to read and verify entries quickly during line clearance.

2) What this product is used for
  • Note taking and data recording in cleanrooms and controlled environments.
  • Record keeping, data transfer, observations, and work-in-process notes supporting batch records and deviation investigations.
  • Facilities and engineering documentation (PM checklists, work orders, line clearance sign-offs).
  • Shift handover notes where consistent legibility and reduced smearing matter under gloves and frequent wipe-down workflows.
3) Why customers consider this product
  • Designed to reduce particle and fiber generation compared with everyday office notebooks (manufacturer positioning for TexWrite cleanroom bond).
  • Pages printed with IPA-resistant, low-sodium ink to reduce ionic contamination and support alcohol wipe-down practices.
  • High-density polyethylene cover described as chemical resistant.
  • Spiral binding and fully rotating pages allow the notebook to lie flat for quicker, more consistent entries during gloved work.
  • Cleanroom packaged for more controlled introduction than general-use stationery.
4) Materials, composition, and build

Texwipe describes TX5740 as a spiral-bound cleanroom notebook with high-density polyethylene covers, plastic spirals, and TexWrite cleanroom paper. The current Texwipe product page describes the paper as a “copolymer cleanroom paper” and also states “no natural latex binders.” An older datasheet copy hosted by SOSCleanroom describes “latex-impregnated cleanroom paper.” When your internal risk assessment is sensitive to latex-related concerns, rely on the most current manufacturer statement and confirm acceptance criteria through your quality system.

Practical receiving cue: verify the cover and spiral are intact (no cracking, chips, or sharp edges) and that the first few pages turn without binding.

5) Specifications in context
Attribute TX5740
Manufacturer / brandITW Texwipe (TexWrite)
Product typeCleanroom spiral notebook
ColorWhite
RulingCollege-ruled
Overall size8.5" x 11" (216 mm x 279 mm)
Writable pages / sheets100 writable pages (50 sheets)
CoverHigh-density polyethylene (HDPE), chemical resistant (manufacturer statement)
BindingPlastic spiral; lies flat; rotating pages (manufacturer statement)
InkIPA-resistant, low-sodium ink (printed pages)
Autoclave guidanceAutoclaving not recommended
Cleanroom environment guidanceISO Class 3–8; Class 1–100,000; EU Grade A–D (manufacturer statement)
Packaging10 notebooks per case
SterilityNot published
Country of originMade in USA (per Texwipe TDS)
Typical basis weight (paper)80 g/m² (typical; not a specification)
Typical caliper5.0 mil (typical; not a specification)
Typical opacity74% (typical; not a specification)
Typical surface resistivity2.6 × 109 ohms (typical; no explicit ESD classification statement in source basis)
6) Performance and cleanliness considerations

The typical contamination profile for TX5740 is published in the Texwipe technical data sheet as representative analyses (not specifications).

Typical contamination characteristics (published as typical, not specifications)
Metric Typical value
Particles > 0.5 µm4.8 million particles/m²
Sodium (ion extractable)85 ppm
Chloride (ion extractable)50 ppm

TX5740’s printed pages are described as using IPA-resistant ink; however, resistance to other solvents and disinfectants (ethanol, quats) is not published in the source basis. If your workflow includes frequent disinfectant wipes on documentation, qualify your writing instruments and dry time as part of line clearance.

ESD handling note: a typical surface resistivity value is published in the technical data sheet, but there is no explicit claim that the notebook is “dissipative” or “conductive.”

7) Packaging, sterility, traceability, and country of origin
  • Packaging: 10 notebooks per case. Described as cleanroom packaged.
  • Sterility: Not published in the source basis.
  • Autoclave: Autoclaving is not recommended (manufacturer statement).
  • Country of origin: Made in USA (per Texwipe TDS).
  • Traceability tip: log the case label information into your material receipt record and store notebooks in original packaging until release to the floor.

For over 35 years, SOS and Texwipe have been close partners, and SOSCleanroom is the authorized Master Distributor of ITW Texwipe for the United States market.

8) Best-practice use
  • Zone control: assign notebooks to a room/area and avoid carrying them across uncontrolled corridors without a defined transfer method.
  • Glove discipline: keep a “writing glove” or fingertip cover practice to reduce ink transfer and page smudge during long entries.
  • Dry time check: standardize a brief dry time before turning pages.
  • Wipe-down reality: if you wipe covers with IPA, use light pressure and avoid scuffing the spiral against stainless edges.
  • Line clearance: do a routine visual scan for torn corners, loose spiral fragments, or cover damage before the notebook enters the critical zone.
9) Common failure modes
  • Ink smear and transfer: typically caused by quick page turns, heavy ink load, or writing instrument mismatch.
  • Spiral abrasion debris: spiral edges can scrape stainless, carts, or drawer slides; store notebooks flat or in dedicated holders.
  • Cover scuffing and particle fallout: rough handling in toolboxes or maintenance carts can damage covers; retire notebooks with cracked covers.
  • Uncontrolled migration between zones: define a transfer method before moving notebooks into cleaner spaces.
10) Closest competitors

Common alternatives include cleanroom stationery from Micronova and Berkshire, as well as other ITW Texwipe TexWrite formats (different sizes and binding styles).

Selection shortcut: if your dominant risk is wipe-down and chemical exposure, prioritize cover material and ink behavior; if your dominant risk is particle sensitivity, prioritize documented particle/fiber performance data and packaging discipline.

11) Critical environment fit for this product

Texwipe lists TX5740 for use across ISO Class 3–8 (EU Grade A–D), supporting controlled documentation where reduced particle/fiber generation and cleaner inks are desired.

If your environment requires sterile documentation materials, sterility is not published in the source basis and should be confirmed through your procurement and quality process before adoption.

12) SOSCleanroom note about SOPs

The Technical Vault is written to help customers make informed contamination-control decisions and improve day-to-day handling technique. It is not your facility’s Standard Operating Procedure (SOP), batch record, or validation protocol.

Customers are responsible for establishing, training, and enforcing SOPs that fit their specific risks, products, equipment, cleanroom classification, and regulatory obligations. Always confirm material compatibility, cleanliness suitability, sterility requirements, and acceptance criteria using your internal quality system and documented methods.

If you adapt any technique guidance from this entry, treat it as a starting template. Your team should review and approve the final method, then qualify it for your specific surfaces, solvents, cleanliness limits, inspection methods, and risk profile.

13) Source basis
SOSCleanroom is the source for this Technical Vault entry.
Briefed and approved by the SOSCleanroom (SOS) staff.
If you have any questions please email us at Sales@SOSsupply.com
Or give us a call at (214)340-8574.
If you need additional information please try our SOSCleanroom specific AI ChatBot which draws from our extensive cleanroom specific libraries.
Last reviewed: May 4, 2026
© 2026 SOSCleanroom