Skip to main content

CTI NWCP 200 vs HandPRO 9300 | ISO 4 Glove Comparison

SOSCleanroom Technical Vault | Cleanroom Glove Engineering

CT International NWCP 200 vs. HandPRO 9300: Which ISO 4 Nitrile Glove Delivers Better Value?

A detailed engineering and purchasing guide to particle cleanliness, nonvolatile residue, ESD, strength, glove qualification and the true cost of an ISO 4 alternative.

Technical comparison reviewed:  |  Published pricing checked:

Shop CT International NWCP Series Ask for Samples & Volume Pricing

Executive Overview: The Closest CTI Alternative to HandPRO 9300

The CT International NWCP 200 Series is the closest CTI alternative to Hourglass HandPRO 9300 in the information reviewed. Both are non-sterile, white, 12-inch-class nitrile cleanroom gloves marketed for Class 10 / ISO 4-compatible environments. CTI's NWCP series is DI-water-washed, antistatic, textured at the fingertips and double-bagged.

CTI supplied SOSCleanroom with comparison data indicating a particle-count threshold below 400 for NWCP 200 versus Hourglass's published value below 650 particles/cm². CTI also reported a nonvolatile-residue (NVR) threshold below 2.5 µg/cm² versus Hourglass's published threshold below 5.0 µg/cm². These are specification ceilings, not actual measured results from matched production lots. Crucially, the comparison cannot yet be treated as a validated like-for-like cleanliness test: CTI's particle units and full test conditions have not been independently verified.

SOSCleanroom's selection verdict

For qualified ISO 4 applications, evaluate CTI NWCP 200 before paying more for HandPRO 9300.

The buying case is straightforward: the same stated ISO 4 application class, a verified $266.00/1,000-glove SOSCleanroom listing, an established DI-water-washed CTI manufacturing route and CTI-reported tighter cleanliness acceptance limits. That makes NWCP 200 a compelling first option for cost reduction and second-source programs.

What we are not claiming: CTI has not yet provided a method-matched head-to-head study demonstrating fewer particles per unit area, lower observed residue in every lot, superior chemical protection or higher tensile strength. Approve the alternative only after the required product-specific evaluation.

Review CTI NWCP 200 Product Ask About Evaluation Samples

Comparable cleanroom positioning

ISO 4

Both NWCP 200 and HandPRO 9300 are positioned for Class 10 / ISO 4 applications.

Supplier-reported particle ceiling

<400

CTI-supplied NWCP figure; Hourglass publishes <650 particles/cm² (0.5–20 µm). Methods and units require alignment.

Supplier-reported NVR ceiling

<2.5

µg/cm² for NWCP versus Hourglass's published <5.0 µg/cm². Extraction methods must be compared.

SOSCleanroom selection perspective: NWCP 200 is the appropriate CTI candidate for a customer seeking an ISO 4 alternative to HandPRO 9300. CTI NCP 200 (ISO 5 / Class 100) is a separate option for applications qualified to a different cleanliness profile.

CTI NWCP 200 vs. HandPRO 9300: Published Price Comparison

Price check date: . This table is a dated snapshot of advertised prices, not live competitor pricing or a guaranteed quote.

For purchasers comparing ISO 4 / Class 10, non-sterile, 12-inch nitrile gloves, case cost matters alongside cleanliness qualification. At the time of this review, SOSCleanroom displayed the CT International NWCP Series at $266.00 per case of 1,000 gloves, a lower published case price than several listed HandPRO 9300 distributors.

SOSCleanroom | CTI NWCP Series

$266.00

Per 1,000 gloves • $0.266 per glove • published Nov. 6, 2026

Listed HandPRO 9300 case prices checked

$285.71–$477.50

Four published 1,000-glove case listings; actual prices vary by distributor, account, size and quantity.

Seller / Product Published price per 1,000 Price difference vs. SOS case Difference as share of listed seller price
SOSCleanroom / CTI NWCP 200 $266.00 Reference price —
Midwest Production Supply / HandPRO 9300 $285.71 $19.71 higher 6.9%
Lab Depot / HandPRO 9300 $305.00 $39.00 higher 12.8%
Krackeler Scientific / HandPRO 9300 $390.00 $124.00 higher 31.8%
Fisher Scientific (Large) / HandPRO 9300 $477.50 $211.50 higher 44.3%

Why consider CTI? In the published case listings above, NWCP provides a lower entry price while offering the same nominal ISO 4 / Class 10 cleanroom positioning and supplier-reported lower particle/NVR acceptance ceilings. The latter are specifications awaiting method-equivalence confirmation, not proof of superior results across manufacturing lots.

Pricing transparency: These prices are a historical comparison, not a universal lowest-price guarantee. For example, R.S. Hughes displayed HandPRO 9300 at $25.61 per bag of 100 during this review (a theoretical $256.10 for ten bags), which is below SOS's listed case price before any shipping/quantity considerations. Midwest also advertised quantity discounts. Bag prices, case prices, discounts and fulfillment terms are not automatically interchangeable. For current NWCP pricing, always check the live SOSCleanroom product page or request a written volume quote.

Switching from HandPRO 9300? Request samples and a quantity quote.

Tell our team which HandPRO size you use, the intended CTI glove size, your estimated monthly or annual case usage, and the contamination-control requirements you need documented. Ask about NWCP evaluation samples and quantity-based special pricing. Sample availability and quotations are subject to confirmation.

Request NWCP Samples & Volume Pricing View Current NWCP Case Price

Or call 800-443-7101 and reference CT International NWCP Series / HandPRO 9300 replacement evaluation.

Published price sources for the November 6, 2026 snapshot

Displayed prices and availability can change without notice; visiting a source after the review date may show a different amount. Price comparison excludes contract terms, promotions, tax, freight and any non-comparable purchase-unit conditions. No competitor offers are endorsed by SOSCleanroom.

What Does a Glove Change Mean for Purchasing Cost?

Volume buyers should calculate spend at the same usable glove quantity, rather than comparing a single bag price with a case price. For the four HandPRO case listings reviewed, SOSCleanroom's NWCP price equates to $0.266 per glove. The Midwest HandPRO case listing equates to approximately $0.286 per glove; Lab Depot is $0.305, Krackeler $0.390 and Fisher's Large listing $0.4775.

Illustrative use SOS CTI NWCP at displayed $266/case HandPRO at Lab Depot $305/case Listed-price difference
5 cases / 5,000 gloves $1,330.00 $1,525.00 $195.00
25 cases / 25,000 gloves $6,650.00 $7,625.00 $975.00
100 cases / 100,000 gloves $26,600.00 $30,500.00 $3,900.00

Illustrative arithmetic using November 6, 2026 displayed case prices, assuming unchanged single-case prices for all quantities. These are not current volume quotations or guaranteed savings. Actual discounts, case-mix, freight, taxes and order terms may materially change results. A trial may entail separate qualification costs.

Purchasing recommendation: Bring your annual case forecast, incumbent HandPRO part numbers and target delivered price to SOSCleanroom. Ask for a written special quantity price, evaluate NWCP samples in your process, and compare delivered, qualified cost per usable glove—not just a list price.

Particle Count Charts: Reading the Published and Supplier-Reported Limits

Cleanroom glove particle specifications describe contamination associated with the glove, rather than airborne particles in the room. The charts below visualize the numerical specification ceilings supplied for this comparison. They do not represent actual measured particles on gloves, field defect rates or independently normalized comparison data.

Chart 1 | Reported glove particle specification ceilings

Lower numeric thresholds can indicate a more restrictive specification only if counting ranges, units and methods are equivalent.

CT International NWCP 200 | ISO 4<400*
Hourglass HandPRO 9300 | ISO 4<650 particles/cm²
CT International NCP 200 | ISO 5 reference<950*
CTI NWCPHandPRO 9300CTI NCP (different cleanroom class)

Chart interpretation: Bar length reflects only the reported numerical ceiling relative to the largest shown (950). Hourglass defines its result as particles/cm² for 0.5–20 µm. CTI's supplied sheet identifies particles ≥0.5 µm but does not establish the same unit denominator, upper size limit, extraction procedure or counting method. The bars must not be interpreted as proof that NWCP releases fewer particles or is 38% cleaner. *CTI numbers are supplier-reported and pending a product-specific, method-qualified specification sheet.

Why this matters: In wafer handling, optical coating, sensor assembly and precision component packaging, a glove can introduce particles through physical contact, handling, abrasion or packaging. A lower verified glove-specific particle limit may help a process engineer establish a cleanliness budget, but actual suitability requires process qualification.

Chart 2 | Nonvolatile residue (NVR) specification ceilings

Units: µg/cm² (micrograms per square centimeter). Lower limits can be relevant to surface-contamination-sensitive processes.

CT International NWCP 200<2.5 µg/cm²*
Hourglass HandPRO 9300<5.0 µg/cm²
CT International NCP 200 | ISO 5 reference<5.0 µg/cm²*

Chart interpretation: CTI's submitted NWCP NVR ceiling is numerically half the Hourglass published ceiling. This is a difference between reported acceptance thresholds, not proof of half the residue in production gloves. Extraction solvents, temperature, time, surface-area calculations and analytical methods must be reconciled before comparing results directly. *CTI values are supplier-provided.

Side-by-Side Technical Specifications

Reading the table: "Published" means verified on the linked manufacturer's product page or HandPRO specification; "CTI supplied" means furnished in the comparison provided to SOSCleanroom, but not independently confirmed on the public NWCP product page.

Engineering parameter CTI NWCP 200 Hourglass HandPRO 9300 Qualification implication
Material 100% nitrile, published Nitrile, published Both are non-natural-rubber-latex glove options.
Cleanroom compatibility Class 10 / ISO 4, published Class 10 / ISO 4, published Same nominal application class, not independent certification of individual gloves.
Sterility Non-sterile Non-sterile Neither substitutes for a sterile glove when sterility is required.
Length 12 in ±0.5 in, published 295 mm minimum; 303–305 mm typical, published Confirm wrist coverage with gown/sleeve system.
Fingertip thickness 0.18 ±0.01 mm, CTI supplied* 0.14–0.16 mm typical, published CTI also publishes an unspecified-location 5 ±1 mil thickness; reconcile measurement locations before comparing.
Palm / cuff thickness 0.11 / 0.08 mm nominal, CTI supplied* 0.10–0.11 / 0.08–0.09 mm typical, published Compare thickness methodology and operator feel.
Tensile strength 14 MPa published 14 MPa minimum; 23.8–28.0 MPa typical before aging Shared baseline figure does not prove equal typical strength.
Elongation before aging 500% published 500% minimum; 560–580% typical Evaluate measured lot performance if critical.
Particle ceiling <400, CTI supplied* <650 particles/cm² at 0.5–20 µm, published Do not normalize without matching units and methods.
NVR ceiling <2.5 µg/cm², CTI supplied* <5.0 µg/cm², published CTI-reported threshold is numerically lower; analytical equivalence pending.
Sulfur / accelerator claims Free of both, CTI supplied* Sulfur-free; accelerator-free, published Obtain CTI formulation declaration for controlled qualification.
ESD properties Antistatic, published; no numerical resistance shown Static dissipative in use, published Request quantitative test results for ESD-controlled processes.
Surface / packaging Textured fingertips; double-bagged, published Finger-textured; double-bagged, published Evaluate grip, material transfer and cleanroom unpacking practices.
Case quantity 1,000 gloves/case, published 1,000 gloves/case, published Confirm preferred size and dispensing pack configuration.
Low-endotoxin documentation No quantitative endotoxin limit confirmed on reviewed CTI public specification Described by manufacturer as low endotoxin; request numerical lot test results For endotoxin-sensitive processes, verify an explicit limit and method.
Chemical PPE certification Not established from reviewed public NWCP source for a specific exposure Hourglass spec identifies EN ISO 374-1 Type B and EN ISO 374-5 Do not substitute gloves in chemical or biological exposure tasks without appropriate approvals.
Freedom-from-holes AQL Not established from reviewed public NWCP sources AQL 1.5, published Do not claim equivalence without current CTI quality documentation.

* CTI-provided comparison information; current independent, product-specific substantiation has not been reviewed for this value. CTI's published general glove thickness is 5 ±1 mil (roughly 0.127 ±0.025 mm) without identifying the measurement point. Accordingly the supplier-provided 0.18 mm fingertip result is presented as provisional, not as a confirmed physical advantage.

Why Class 10 / ISO 4 Is Different from Class 100 / ISO 5

ISO 14644-1 addresses airborne particle concentrations in the room, not particles extracted from glove surfaces. This is a separate measurement system from Chart 1 above. NWCP and HandPRO are positioned for ISO 4, while CTI's NCP Series is positioned for ISO 5.

Chart 3 | Airborne ISO class limits at ≥0.5 µm

Maximum airborne particle concentration, particles per cubic meter (particles/m³).

ISO Class 4 | Historical Class 10352/m³
ISO Class 5 | Historical Class 1003,520/m³

Educational distinction: The ISO 4 airborne concentration limit at this size threshold is one-tenth the ISO 5 limit. These values describe air cleanliness classification; they are not permissible particle counts on a glove. A glove described as "ISO 4 compatible" still needs product-specific cleanliness and use qualification.

Why Particle and Residue Limits Matter in Practice

Particles: physical contamination

Surface contact, donning, packaging transfer and glove abrasion may introduce contamination to wafers, optics, small assemblies and clean fixtures. Particle specifications can support material-selection decisions only when the analytical basis is clearly defined.

NVR: molecular and film-forming contamination

Nonvolatile residue represents material remaining after a defined extraction and evaporation process. Total NVR does not reveal the chemical identity of any residue, so sensitive applications may require ionic and organic analysis as well.

What must be matched to make a defensible comparison?

  • Particle size range: Is the lower cutoff ≥0.5 µm for both, and is the upper size range the same?
  • Units: Are results expressed per glove, per sample, or per cm² of glove surface?
  • Extraction: Do the labs use the same washing/extraction liquid, agitation, extraction duration and analysis instruments?
  • NVR chemistry: Are solvent, temperature, drying procedure and surface-area normalization equivalent?
  • Decision basis: Are figures manufacturing acceptance limits, tested lot averages or individually measured results?

Important: A tighter specification ceiling is not a measured reduction in process defectivity or a guarantee of cleaner gloves in every lot. For a high-value application, request current certificates of analysis and, where appropriate, perform application-specific qualification.

How a Cleanroom Glove Can Contaminate an Otherwise Clean Process

Air cleanliness is just one part of contamination control. A cleanroom can satisfy its airborne classification while a hand-contact step transfers removable particles or residues to a product. For high-value wafers, precision optics, sensors or bonding interfaces, contact materials must be qualified independently of the room.

01 / Incoming material

A glove arrives with a packaging and lot-specific contamination profile.

02 / Donning & movement

Unpacking, stretching, friction or contact with nonqualified surfaces may mobilize material.

03 / Contact transfer

Particles, ions or organic residue may transfer when the glove touches tools or product surfaces.

04 / Process outcome

Depending on the process, contamination may affect yield, adhesion, visual quality or test confidence.

Why washing and double-bagging matter

CTI publicly identifies NWCP as DI-water-washed and double-bagged. DI-water washing is a meaningful processing detail because it is intended to control certain removable contamination; double-bagging supports staged material transfer from receiving to a cleaner production zone. Neither feature alone establishes an allowable particle or ionic contamination level—the product must still be measured and handled properly.

Which tests should follow the glove into the process?

  • Liquid particle count (LPC): use the agreed lower size cutoff, counting range, extraction method and a common area basis such as particles/cm² where applicable.
  • Nonvolatile residue: compare total recovered mass per area under a controlled extraction/evaporation method; consider multiple solvents when process chemistry requires it.
  • Ionic extractables: evaluate sodium, chloride, potassium, calcium and relevant anions using a qualified method, when trace ionic contamination is a failure mechanism.
  • Contact-transfer test: expose representative coupons, optical witness plates or components to the glove under defined contact pressure and duration, then measure contamination.
  • Wear-generated particles: where relevant, test after realistic movement or repeated handling rather than relying exclusively on a new-glove extraction.

The key engineering question: Will NWCP 200 reduce contamination risk in your process while satisfying operator protection requirements at a lower qualified purchase cost? A method-matched sample study is the appropriate way to answer it.

Thickness, Dexterity, Tensile Strength and Operator Comfort

CTI's comparison lists a nominal NWCP fingertip thickness of 0.18 ±0.01 mm versus Hourglass's typical 0.14–0.16 mm. CTI's public NWCP page, however, lists a generic thickness of 5 ±1 mil and does not identify the point of measurement. Therefore we recommend confirming a current CTI dimension drawing or controlled data sheet before calling the NWCP a thicker-finger glove.

Thickness does not establish puncture resistance, durability, chemical permeation resistance or tactile sensitivity by itself. Glove formulation, geometry, mechanical data and actual use all matter. Hourglass publishes typical before-aging tensile results of 23.8–28.0 MPa alongside its minimum of 14 MPa; CTI's public NWCP page states 14 MPa without a matching distribution of typical results. A superiority claim for NWCP tensile strength is not supported by the reviewed public data.

Recommended operator trial

  • Small-part pickup, manipulation and tool handling.
  • Dry and wet grip performance on process fixtures.
  • Fit under cleanroom garments, cuff coverage and gown compatibility.
  • Comfort, dexterity and breakage during realistic wear durations.
  • Any process-specific abrasion, chemical contact or static-charge risks.

Interpreting the CTI Particle <400 and NVR <2.5 Claims Correctly

The CTI comparison supplied to SOSCleanroom lists <400 particles ≥0.5 µm and <2.5 µg/cm² NVR for NWCP 200. Hourglass publishes <650 particles/cm² at 0.5–20 µm and <5.0 µg/cm² NVR. The figures suggest an attractive CTI acceptance profile, but only the Hourglass document clearly states the particle surface-area denominator and counting interval in the information currently reviewed.

Particle count is not an interchangeable number

For instance, a result reported as particles per glove cannot be directly compared with particles per cm². Even two area-normalized results may differ if one method counts particles above 0.5 µm without an upper cutoff while another is restricted to 0.5–20 µm. Agitation, extraction water, recovery efficiency, sampling, blank correction and instrumentation also influence the apparent value.

What exactly is NVR?

Nonvolatile residue is the material left after a defined extraction solvent is collected and evaporated. It may represent removable organic or inorganic compounds, but its total mass does not reveal which compounds are present. A lower NVR ceiling is relevant when a process is sensitive to thin-film contamination, coatings, adhesive bonds or trace analytical interference; it is not a universal guarantee of better chemical compatibility.

Four questions that turn these figures into usable purchasing criteria

  1. Are the data limits contractual maximums, typical lot measurements, or single-sample results?
  2. Are the particle counts normalized to the same sampling area and size range?
  3. Were the NVR measurements performed with comparable extraction solvents and analytical conditions?
  4. Can CTI supply the specific lot data and documentation required by the customer's quality system?

IEST-RP-CC005.4 is a recognized recommended practice for testing cleanroom gloves and finger cots. CTI's public product listing references the earlier IES-RP-CC-005.2 testing method, while the Hourglass PDF references IEST-RP-CC005.4. This is an additional reason to request full method details rather than assume equivalence from the common IEST family name.

Accelerator-Free, Sulfur-Free and Antistatic Claims

Hourglass publishes HandPRO 9300 as accelerator-free and sulfur-free. CTI supplied those same descriptions for NWCP 200, although they are not stated on the public CTI NWCP product page reviewed for this article. For processes sensitive to particular additives or operator skin sensitization, request the current CTI formulation declaration.

Both manufacturers also describe their products using antistatic or static-dissipative language. Those descriptions are not equivalent to a verified surface-resistance or charge-decay result under the customer's exact test conditions. Facilities with ESD control requirements should request numerical resistance values, test method, test humidity and conditions of use.

Chemical protection is a separate qualification. Nitrile construction and cleanroom compatibility do not by themselves demonstrate protection against any specified solvent, chemical splash or hazardous drug. Select chemical PPE using chemical-specific permeation, degradation and applicable certification data.

Cleanliness Is Not a Substitute for Barrier, ESD or Chemical Qualification

Barrier integrity and hole AQL

Hourglass explicitly specifies an AQL of 1.5 for freedom from holes in its HandPRO 9300 product sheet. CTI describes NWCP as leak-tested, but the public NWCP listing reviewed does not supply a directly comparable holes-AQL value. AQL is a sampling-based quality acceptance parameter; it is not a prediction that exactly 1.5% of gloves in every shipment contain holes. Request a current CTI sampling and defect specification where barrier integrity is a critical purchasing requirement.

ESD and static dissipation: what is still missing?

CTI describes NWCP as antistatic; Hourglass describes HandPRO 9300 as static dissipative in use. Neither description, by itself, establishes a quantitative resistance or charge-decay requirement for an electronics assembly line. A meaningful comparison requires the test method, humidity, conditioning, instrument settings and numerical results. Ask whether performance is measured with the glove worn, and whether glove fit and contact surfaces affect the observed result.

Chemical exposure and low-endotoxin applications

Hourglass publishes EN ISO 374-related chemical/biological PPE information and markets HandPRO 9300 as a low-endotoxin glove. The CTI public NWCP product page reviewed does not show equivalent chemical-permeation data or a numerical endotoxin specification. These are not proven CTI advantages; if your process requires either, obtain documentation and approval before substitution. A glove compatible with ISO 4 air cleanliness is not necessarily suitable for aseptic compounding, cytotoxic drug exposure or a specified solvent.

When would Hourglass remain the rational choice? When a process is already validated around a documented HandPRO property that CTI has not yet substantiated—such as a particular chemical PPE certification, low-endotoxin test, tensile behavior or hole-AQL requirement—and the cost or risk of requalification outweighs the quoted savings. This is why we encourage a documented NWCP trial, not an unqualified one-for-one substitution.

Where CTI NWCP 200 Deserves a Controlled Trial

Semiconductor & microelectronics

Potential applications include qualified wafer-carrier handling, component assembly and inspection operations that require low particle-transfer and low-residue materials.

Optics & photonics

Precision coating, lens or photonic component processes may benefit from careful controls around glove-transferable particles and residues.

Medical device manufacturing

Where non-sterile gloves are permissible, evaluate glove cleanliness against documented product-contact and bioburden-control requirements.

Analytical & precision laboratories

Assess glove extractables, ionic contaminants and sample compatibility before handling trace-analysis samples or sensitive materials.

Even when a glove is suitable for a cleanroom classification, it may not be suitable for every operation in that cleanroom. For applications requiring sterile gloves, select a separately qualified sterile glove.

How to Qualify a HandPRO 9300 Alternative

  1. Record the actual process: cleanroom classification, contact surfaces, sterility requirement, chemical exposure, ESD controls and wear duration.
  2. Request current data: revision-controlled CTI NWCP specification, current Hourglass specification, pertinent COAs, quality and traceability records.
  3. Normalize particle testing: same particle-size interval, reported area/unit denominator, extraction method and acceptance criterion.
  4. Normalize NVR testing: compare solvent and extraction procedure; request ion data if the process is sensitive to ionic contamination.
  5. Check integrity and formulation: hole AQL, mechanical specifications, accelerator/sulfur declarations and required chemical testing.
  6. Run a documented trial: evaluate wearing performance and product-contact cleanliness in the actual application.
  7. Document approval: complete change control and supplier qualification before substitution into a validated process.

Purchasing perspective: Compare more than case price. Consider accepted-lot cleanliness, handling efficiency, packaging configuration, glove consumption, qualification effort and the cost of process contamination.

Implementation Checklist: Protect the Value of a Cleaner Glove

A glove cannot perform to its intended cleanliness profile if contaminated during unpacking, donning or handling. The following controls should be adapted to the facility's validated gowning and material-transfer SOPs.

Receiving and storage

  • Record the manufacturer, series, glove size and lot/batch identifier where available.
  • Check the bag seal and any visibly damaged packaging.
  • Store under conditions specified by the manufacturer, segregated from unapproved materials.
  • Confirm the selected bag/case quantity before adding to approved stock lists.

Transfer, donning and use

  • Use the approved staged transfer process for outer and inner cleanroom bags.
  • Follow site-approved hand hygiene and gown-to-glove cuff overlap practices.
  • Do not touch noncontrolled surfaces after donning and before a sensitive process step.
  • Change gloves after a known contamination event, damage, or the facility's defined wear interval.

Suggested one-page NWCP trial record

Field to record Why it matters
Incumbent glove, SKU, size and lot Ensures the right HandPRO version is being compared with the right CTI series and size.
NWCP sample size and lot Supports traceability and a repeatable wear trial.
Process and material contact conditions Determines how representative the test will be of routine use.
Glove damage, grip and ergonomic feedback Captures functional suitability beyond laboratory cleanliness limits.
LPC/NVR, ion or ESD test data, if required Connects glove selection to process-specific acceptance criteria.
Quality approval and procurement sign-off Documented evidence for substitution and ongoing supplier control.

Which CT International Series Should You Buy?

Choose NWCP 200 for evaluation against HandPRO 9300: both are positioned for ISO 4 / Class 10 environments. Size range difference: Hourglass lists XS–XXL, while CTI NWCP is listed S–XXL; customers wearing XS need a separately qualified size solution. Consider NCP 200 separately: CTI markets the NCP 200 Series for ISO 5 / Class 100 environments, which may be appropriate when it meets the process's required cleanliness profile.

CTI NWCP 200 | ISO 4

DI-water-washed, non-sterile nitrile, 12-inch length, textured fingertips, antistatic and double-bagged; listed by SOSCleanroom in Small through XX-Large.

View NWCP 200 Product

CTI NCP 200 | ISO 5

Non-sterile nitrile alternative positioned for Class 100 / ISO 5 environments; determine suitability from the facility's actual requirements.

View NCP 200 Product

Frequently Asked Questions

Is NWCP 200 an ISO 4 alternative to HandPRO 9300?

Yes, both manufacturers position these gloves for ISO 4 / Class 10 compatible use. A process-specific substitution still needs qualification and documented acceptance.

Does the <400 versus <650 particle chart prove NWCP is cleaner?

No. The 400 figure is CTI-supplied without independently verified normalization and test details, while the Hourglass figure is <650 particles/cm² in the 0.5–20 µm interval. The comparison is a useful lead for qualification, not a demonstrated head-to-head result.

Is the NWCP NVR specification half the HandPRO specification?

The CTI-supplied acceptance ceiling of <2.5 µg/cm² is numerically half Hourglass's published <5.0 µg/cm² ceiling. This does not mean actual measured residue is necessarily half, and methods must be reviewed.

Is a 12-inch Class 10 glove automatically sterile?

No. NWCP 200 and HandPRO 9300 are both non-sterile products. Sterility is a distinct property from particle cleanliness or ISO room compatibility.

Does higher fingertip thickness mean better protection?

Not automatically. Thickness is only one variable. Puncture, tensile, chemical and comfort performance need appropriate, comparable test data. CTI's supplier-provided fingertip thickness also needs reconciliation with its public generic thickness specification.

Are these price comparisons current offers?

No. Prices are a dated review of publicly displayed listings checked November 6, 2026. The live SOSCleanroom product listing and a current written quote govern what SOSCleanroom offers today. Some competitor bag prices or negotiated account discounts may be lower than the sampled case listings.

Can I request NWCP 200 samples or special pricing for larger quantities?

Yes. Contact SOSCleanroom through the quote request page and mention CT International NWCP Series, glove size, intended application and estimated case volume. The team can review sample requests and offer a current quantity quotation subject to availability.

Which CTI sizes are available through SOSCleanroom?

The live NWCP product listing provides Small, Medium, Large, X-Large and XX-Large options, with a case quantity of 1,000 gloves.

Why does ISO 4 not guarantee that a glove has fewer particles than an ISO 5 glove?

ISO 14644-1 classifies airborne particles in a cleanroom. A glove's removable particle burden is a separate material test. The manufacturer's intended cleanroom class is useful for product screening, but it does not replace glove-specific measurements or process qualification.

Does CTI make the same low-endotoxin and chemical PPE claims as Hourglass?

Not in the CTI NWCP public product source reviewed here. Hourglass specifically markets low-endotoxin characteristics and identifies EN ISO 374-related information. Request documented CTI endotoxin limits and any required chemical PPE test results before replacing a glove selected for those criteria.

Does SOSCleanroom offer 9300 cross-reference assistance?

Yes. Provide your HandPRO 9300 part number, current size, case usage, relevant process requirements and target price through the SOSCleanroom RFQ page. Ask for CT International NWCP 200 alternatives, available evaluation samples and a current volume quotation.

Technical Sources, Data Status and Important Qualifications

  1. CT International: NWCP Series manufacturer product page, including ISO 4 compatibility, antistatic designation, testing reference, general thickness and packaging.
  2. Hourglass International: HandPRO 9300 Product Specification, PS-9300-111120, including particulates, NVR, dimensional and tensile specifications.
  3. CT International supplier comparison: NWCP 200 versus HandPRO 9300 versus NCP 200 specification matrix supplied directly to SOSCleanroom. CTI-specific particle, NVR, fingertip thickness and formulation claims in this article are attributed to this supplier document where not verified in current public specifications.
  4. ISO 14644-1: official ISO 14644-1:2015 overview, classification of airborne particle concentration; separate from glove-surface counts.
  5. IEST-RP-CC005.4: IEST practice for glove/finger-cot evaluation covering cleanliness, physical and chemical integrity, and relevant glove properties.

Technical values are subject to current manufacturer revisions and application-specific qualification. Published pricing was checked November 6, 2026 and is not maintained as a live feed; see the dedicated price section for sources and limitations. Particle/NVR figures are specification limits, not results from a shared controlled study. Comparative statements do not claim a product is certified for a particular process or that one glove necessarily causes fewer defects. Hourglass and HandPRO are trademarks or product identifications of their respective owner and are referenced for factual comparison only.

Evaluate CTI NWCP Series: Ask for Samples and Special Quantity Pricing

Replacing HandPRO 9300? Before renewing a higher-priced case contract, give CTI NWCP 200 a controlled evaluation. Review our live case price, then ask SOSCleanroom to discuss sample availability, technical documentation and a written special price for your projected case volume. Include your current HandPRO 9300 SKU, size and annual usage so our team can make the quotation meaningful. Samples and discounts are subject to availability and approval.

View NWCP Product & Live Price Request Evaluation Samples & Volume Pricing

On the quote form, select a price or cross-reference request and use General notes to request NWCP samples, your size(s), evaluation needs and estimated monthly/annual volume. Or email sales@sossupply.com.

Published price snapshot checked November 6, 2026. Prices may change. Call 800-443-7101 for assistance.

More Cleanroom Glove and Contamination-Control Resources