DURAN® 218505453 GL 45 HYDRA HPLC Purging Bottle - 1,000 mL, Square Borosilicate Glass 3.3, Five GL 45 Necks, 1/Case

DURAN® 218505453 GL 45 HYDRA HPLC Purging Bottle from DWK Life Sciences is a 1,000 mL (1 L), clear, square borosilicate glass 3.3 reservoir with five GL 45 necks: one central opening and four side necks. The additional connection points support HPLC mobile-phase delivery, solvent addition, and purging workflows without relying on a single bottle opening.

Designed for high-performance liquid chromatography (HPLC), the HYDRA provides a common solvent reservoir with multiple accessible ports. Properly configured GL 45 connection caps can route approved solvent lines or permit access while other connected lines remain in place. Five necks do not mean five isolated chambers or five independent pre-installed delivery systems.

DWK describes DURAN borosilicate glass 3.3 as having a very low inorganic ion extractables profile, an important material characteristic for laboratory mobile-phase containers. Its technical literature identifies DURAN clear glass as conforming to ISO 3585 borosilicate glass 3.3 and as ASTM E438 Type I, Class A low-expansion borosilicate glass. These glass classifications do not certify the entire bottle-and-cap configuration for a particular solvent or HPLC system.

The square vessel has a published 94 x 94 mm footprint. DWK lists 217.5 mm catalog height and 222.5 mm overall height; its product flyer also shows 222.5 mm as the bottle height reference. The manufacturer specifies a 30 mm mouth inside diameter and white enamel graduations from 100 to 800 mL in 100 mL steps. Graduations are for estimating liquid quantity, not a certified volumetric tolerance.

For traceability, the HYDRA has a Retrace Code supporting manufacturing-lot certificate lookup. DWK states that capped systems can help reduce the risk of solvent vapor escape, spills, cross-contamination, and air intake. Those outcomes depend on suitable connection caps, tubing, seals, and laboratory procedures; the glass bottle alone is not certified vapor-tight.

Included components require verification: The exact product specification lists polypropylene (PP) for cap/closure material but does not clearly state how many caps are physically supplied. It also does not confirm inclusion of HPLC delivery caps, tubing, fittings, filters, or plugs. DWK lists its three-port HPLC cap as a recommended accessory, not a guaranteed bundled component. Confirm the supplied items when placing an order.

DWK lists one bottle per case. The exact SKU does not state a sterilization designation, autoclave cycle, pressure/vacuum rating, or certified leakproof test. Qualify the complete assembled system for the intended solvent, cap type, temperature, and workflow.

Ordering note: Specify DURAN 218505453 for the 1 L clear square HYDRA bottle with one central GL 45 neck plus four GL 45 side necks; 1 bottle per case. Confirm the number of supplied PP caps and obtain the required HPLC tubing/connection accessories separately unless your supplier confirms they are included.

Specifications:
  • Manufacturer: DWK Life Sciences
  • Brand: DURAN®
  • Catalog number: 218505453
  • Product: GL 45 HYDRA HPLC purging / multi-neck mobile-phase bottle
  • Nominal capacity: 1,000 mL (1 L)
  • Shape: Square, space-saving
  • Bottle color: Clear
  • Bottle material: DURAN borosilicate glass 3.3
  • Glass standard: ISO 3585 borosilicate glass 3.3; manufacturer identifies ASTM E438 Type I, Class A
  • Neck configuration: Five connected GL 45 openings: one central neck plus four side necks
  • Thread finish: GL 45, all five necks
  • Footprint: 94 x 94 mm
  • Width / d / b: 94 mm
  • Height h: 217.5 mm, per exact-SKU specification
  • Overall height: 222.5 mm, per exact-SKU specification and DWK flyer
  • Additional h1 dimension: 183 mm; drawing reference in exact-SKU specification
  • Mouth inside diameter: 30 mm, manufacturer-listed
  • Graduated: Yes; durable white enamel markings
  • Graduation range: 100-800 mL
  • Graduation interval: 100 mL
  • Traceability: Retrace Code; manufacturing-lot certificate lookup supported
  • Closure material in SKU data: Polypropylene (PP)
  • Number of caps actually supplied: Not explicitly established; verify before promising five caps
  • HPLC connection caps, tubing, plugs, filters, fittings: Not established as included; configure/purchase as needed
  • Suggested accessory (separately specified): DWK DURAN 3-port GL 45 HPLC delivery cap, 292312801 (29 231 28 01), per product flyer
  • Purchase unit: One bottle / case of 1
  • Exact-SKU autoclavability: Not stated
  • Sterility: Not stated; no sterile claim established
  • Calibrated volumetric accuracy: Not specified; graduations estimate content
  • Pressure/vacuum rating: Not established
  • Solvent-vapor containment / leak certification: Not established for any proposed cap-and-tubing assembly
  • Shipping weight / carton size: Not confirmed
  • Country of origin for supplied lot: Confirm with manufacturer; literature depicts Made in Germany
Five GL 45 Necks: Why HYDRA Is Different

The central GL 45 neck plus four side necks create five access points to one shared 1 L reservoir. This allows flexible arrangements for mobile-phase delivery, additional connections, and solvent addition when suitable HPLC connection caps are fitted. A side neck can allow solvent to be added without removing the main delivery cap.

DWK identifies improved convenience and reduced risk of cross-contamination and air intake from its five-neck concept. Actual containment depends on keeping unused openings suitably closed and using compatible, correctly assembled cap-and-tubing connections.

Port distinction: Five necks are not five solvent compartments or five independent HPLC channels. No automatic purging mechanism, pump, cap set, or tubing system is established as included with SKU 218505453.

Why DURAN Borosilicate Glass 3.3?

DURAN borosilicate glass 3.3 offers low inorganic ion extractables and broad chemical durability, supporting use with properly selected HPLC mobile phases. DWK identifies the glass material with ISO 3585 and ASTM E438 Type I, Class A. These are material descriptions, not exact-SKU analytical blank guarantees.

Review actual solvent compatibility, including aggressive conditions such as hydrofluoric acid or strong hot alkalis, and confirm compatibility of every cap, seal, and tubing material. Clear glass does not provide the light protection of an amber bottle.

Graduations, Footprint, and Traceability
  • Square footprint: 94 x 94 mm for compact instrument-bench placement.
  • Height: 217.5 mm catalog dimension and 222.5 mm overall; check the complete cap-and-tubing clearance separately.
  • Graduations: White enamel markings from 100 to 800 mL, in 100 mL increments; approximate liquid-level checks only.
  • Retrace Code: Supports identifying the manufacturing lot and retrieving corresponding certificate information from DWK.
  • Case quantity: One bottle; additional HPLC accessories are not guaranteed in the package.
DURAN GL 45 HYDRA Features:
  • 1,000 mL nominal capacity in a square, clear glass HPLC reservoir
  • Five GL 45 openings (one central + four side necks) communicating with the same bottle
  • High-purity DURAN borosilicate glass 3.3 for compatible mobile phases
  • DWK-described low inorganic ion extractables profile
  • 94 x 94 mm square footprint
  • 217.5 mm catalog height and 222.5 mm overall height
  • GL 45 neck threads and manufacturer-listed 30 mm mouth ID
  • Durable white enamel graduations at 100 mL steps from 100-800 mL
  • Retrace Code for manufacturing-lot documentation
  • One bottle per case
Benefits and Common Applications
  • HPLC mobile-phase reservoir: A shared supply bottle with multiple available GL 45 access points.
  • HPLC purging and line-change preparation: Supports configurations used while lines are flushed by the instrument.
  • Mobile-phase replenishment: Suitable side neck access may permit adding solvent without opening the primary delivery port.
  • Liquid handling systems and analyzers: Potential reagent supply in a verified GL 45 connection configuration.
  • Compact bench setups: Square footprint limits the bench area required for a 1 L vessel.
  • Quality systems: Retrace Code supports batch traceability and documentation.

The bottle is a passive reservoir. Purging performance and solvent delivery require the user’s HPLC pump, tubing, fittings, and validated operating procedure.

Best-Practice Selection and Handling
  • Verify SKU and size: Confirm 218505453, 1 L, square, clear, five GL 45 necks.
  • Confirm included items: Establish whether PP caps are supplied, and order the necessary HPLC delivery caps, seals, plugs, and tubing.
  • Assess solvent chemistry: Qualify the glass and each wetted polymer or elastomer in the configured assembly.
  • Check headroom: Allow for 222.5 mm overall bottle height and additional cap/tubing clearance.
  • Protect unused ports: Fit appropriate caps to reduce air ingress, contamination, spills, and solvent vapor exposure.
  • Inspect each glass neck: Check side-neck joints and threads for chips, cracks, and damage.
  • Use graduations as estimates: Do not treat the white enamel scale as calibrated volumetric glassware.
  • Follow HPLC procedures: Purge the instrument lines using the method-approved sequence; the bottle has no powered purge function.
  • Use appropriate ventilation: Manage volatile or flammable mobile phases and waste under the site solvent-safety plan.
  • Do not assume sterilization or pressure ratings: Confirm any temperature, autoclave, vacuum, or positive-pressure requirement with DWK.
Related Configuration and Accessory Notes

Related DURAN multi-neck design: DWK also documents a 2,000 mL GL 45 bottle with one side neck (catalog 219900701). That two-neck configuration is different from the five-neck 1 L HYDRA. A regular single-neck GL 45 bottle is likewise not an equivalent five-port reservoir.

Recommended accessory: DWK’s product-specific technical flyer names a DURAN 3-port GL 45 HPLC delivery cap (292312801) for 3.2 mm outside-diameter tubing. It is a separately specified accessory; verify cap suitability, seals, fittings, and supply with SOSCleanroom before ordering.

Manufacturer Technical Documentation
Why Order DURAN 218505453 From SOSCleanroom?
  • Exact-SKU sourcing: Avoid confusing a five-neck HYDRA with standard GL 45 or single-side-neck bottles.
  • Accessory coordination: Confirm compatible HPLC connection caps, port plugs, and tubing requirements.
  • Manufacturer technical documentation: Access material, product-flyer, and Retrace Code guidance.
  • Centralized purchasing: Source chromatography glassware and related laboratory consumables through SOSCleanroom.
  • Responsive support: Request current case pricing, actual package contents, and lead time.

For pricing, availability, GL 45 caps, or technical documentation: Email Sales@SOSsupply.com or call (214) 340-8574.

Last updated: October 28, 2026

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom). All rights reserved.

The Technical Vault By SOSCleanroom
DURAN 218505453 1,000 mL Borosilicate 3.3 Square 94 x 94 mm Five GL 45 Necks HPLC Purging 100-800 mL Scale Retrace Code 1/Case
Technical Overview: One Reservoir, Five GL 45 Ports

DURAN® 218505453 HYDRA is a 1,000 mL square clear borosilicate glass 3.3 HPLC purging bottle. It provides five GL 45 access points - a central neck and four side necks - on one common liquid chamber. The design supports HPLC mobile-phase storage and delivery, mobile-phase replenishment, and instrument-line purging arrangements.

DWK positions its multi-neck bottle as a more convenient way to use GL 45 HPLC connection caps while reducing the need to disturb an existing solvent-delivery line. With appropriate caps and connections, restricting open ports may help manage air intake, contamination, VOC escape, and spillage.

Exact-SKU takeaway: 1 L, clear, square, borosilicate 3.3; five total GL 45 necks; 94 x 94 mm footprint; 217.5 mm height h; 222.5 mm overall height; 100-800 mL graduations; Retrace Code; 1 bottle per case. The inclusion and number of PP caps or HPLC delivery accessories must be confirmed.

Exact Manufacturer Specifications
Specification DWK information
ManufacturerDWK Life Sciences
BrandDURAN®
Catalog number218505453
ProductGL 45 HYDRA HPLC purging / multi-neck mobile-phase bottle
Nominal capacity1,000 mL (1 L)
ShapeSquare, space-saving
Bottle colorClear
Bottle materialDURAN borosilicate glass 3.3
Glass standardISO 3585 borosilicate glass 3.3; manufacturer identifies ASTM E438 Type I, Class A
Neck configurationFive connected GL 45 openings: one central neck plus four side necks
Thread finishGL 45, all five necks
Footprint94 x 94 mm
Width / d / b94 mm
Height h217.5 mm, per exact-SKU specification
Overall height222.5 mm, per exact-SKU specification and DWK flyer
Additional h1 dimension183 mm; drawing reference in exact-SKU specification
Mouth inside diameter30 mm, manufacturer-listed
GraduatedYes; durable white enamel markings
Graduation range100-800 mL
Graduation interval100 mL
TraceabilityRetrace Code; manufacturing-lot certificate lookup supported
Closure material in SKU dataPolypropylene (PP)
Number of caps actually suppliedNot explicitly established; verify before promising five caps
HPLC connection caps, tubing, plugs, filters, fittingsNot established as included; configure/purchase as needed
Suggested accessory (separately specified)DWK DURAN 3-port GL 45 HPLC delivery cap, 292312801 (29 231 28 01), per product flyer
Purchase unitOne bottle / case of 1
Exact-SKU autoclavabilityNot stated
SterilityNot stated; no sterile claim established
Calibrated volumetric accuracyNot specified; graduations estimate content
Pressure/vacuum ratingNot established
Solvent-vapor containment / leak certificationNot established for any proposed cap-and-tubing assembly
Shipping weight / carton sizeNot confirmed
Country of origin for supplied lotConfirm with manufacturer; literature depicts Made in Germany
Understanding the Five-Neck HYDRA Architecture

The four side necks and the central neck connect to the same 1,000 mL reservoir. This allows additional GL 45 connection options, not separation into five different liquids. A laboratory might dedicate one fitted cap to mobile-phase delivery and another to an approved addition or purge-related operation, depending on its validated setup.

Feature Correct interpretation
Central neckOne GL 45 opening above the common reservoir
Four side necksFour additional GL 45 openings leading to the same reservoir
Total portsFive; not five independent storage chambers
Five HPLC capsBottle can accept up to five compatible GL 45 caps; exact included cap count unverified
PurgingHPLC instrument flushes solvent lines; bottle itself is not a pump or automatic degasser
Air and contamination controlDepends on appropriate closed caps, seals, filters, and operating procedure
Solvent replenishmentAn available side port may provide access while a main delivery connection remains in place

Do not conflate the terms: Four side necks plus one central neck means five GL 45 openings. The bottle is not a multi-chamber mixer or a supplied five-channel HPLC system.

HPLC Purging: What the Bottle Actually Does

In HPLC setup, purging commonly means flushing existing liquid out of the solvent-delivery lines and replacing it with the new mobile phase. The DWK technical flyer explains this as a line-flushing step performed as part of setting up the HPLC system.

  • Reservoir role: Hold compatible mobile phase and provide GL 45 access points.
  • Delivery role: Suitable connection caps and tubing interface with the HPLC system.
  • Purging role: The HPLC instrument or validated apparatus moves the solvent through its lines.
  • Connection role: Additional necks allow flexible lines or access without automatically exposing every opening.
  • Safety role: Keep unused ports closed and use compatible seals and ventilation.
  • Not included by implication: Pump, degasser, gas sparger, PTFE tubing, solvent filter, three-port delivery caps, or fittings.

Confirm the line-purging sequence and any requirement for inert gas, degassing, solvent filtration, and pressure equalization in the specific instrument’s operating procedure.

GL 45 Closure System: Included-Components Check

DWK’s exact-SKU data lists PP (polypropylene) as the cap and closure material, and its literature shows capped examples of the multi-neck HYDRA. However, neither the current product page nor the reviewed flyer specifies how many basic caps are physically included in a case of one. A photograph does not independently establish the supplied cap count.

The manufacturer describes the ability to accept up to five standard GL 45 HPLC connection caps, which means the ports have that thread compatibility. It does not establish that those specialized caps are furnished. DWK separately identifies a three-port GL 45 HPLC delivery cap 292312801 as a recommended accessory.

Component Ordering status
1 L square multi-neck borosilicate bottleThe verified unit of sale: one bottle
Five GL 45 threaded necksIntegral to the bottle
PP material for basic caps/closuresListed in exact-SKU specification
Number of caps furnishedNot expressly confirmed; ask DWK/SOSCleanroom
HPLC multi-port delivery capsAccessories; not shown as included in exact-SKU order specification
Tubing, ferrules, filters, plugs, adaptersNot established as included
DURAN 3-port GL 45 delivery cap 292312801Manufacturer-recommended accessory in technical flyer; separately specified
Caps on product photographsIllustrative; do not infer precise package contents

Purchasing action: For a complete operational HPLC reservoir, list the actual number and type of GL 45 caps, ports, tubing sizes, seals and other accessories in the quote request. Do not assume a five-cap kit is supplied.

Borosilicate Glass 3.3: Standards and Extractables

The bottle body is clear DURAN borosilicate glass 3.3. DWK identifies this material as a low-inorganic-ion-extractables glass suitable for many chromatography solvent reservoirs. Its multi-neck literature links the glass classification to ISO 3585 and ASTM E438 Type I, Class A low-expansion borosilicate glass.

Statement Appropriate scope
Borosilicate glass 3.3Confirmed glass type
ISO 3585Glass-material reference stated by DWK
ASTM E438 Type I, Class AManufacturer’s glass classification; not a whole-system certification
Low inorganic ion extractablesQualitative manufacturer characterization
Solvent-specific cleanlinessVerify for analytical method and reagent grade
Specific ppb ion background or extractables assayNot established for this exact SKU or lot
USP/EP primary pharmaceutical package approvalNot established for the HYDRA assembly
Glass-vs-cap compatibilityEvaluate GL 45 cap liners, tubing, and seals independently

Glass is broadly resistant to many water-based and organic reagents but is not universally inert. Hydrofluoric acid and some strong heated alkaline conditions can attack borosilicate glass. Avoid converting the general glass standard into an assertion that every HPLC solvent mixture is compatible.

Shape, Dimensions, and Graduation Accuracy

DWK specifies a 94 x 94 mm square footprint, 217.5 mm height h, 222.5 mm overall height, 183 mm h1 drawing dimension, and 30 mm mouth inside diameter. Its multi-neck flyer uses 222.5 mm as the overall bottle height reference. Allow additional space for the chosen connection caps, solvent tubing, or gas/vent connections.

The white enamel graduated scale runs from 100 to 800 mL in 100 mL increments. The nominal bottle capacity is 1,000 mL, which is not the same as the highest marked graduation. Graduations are intended for convenient content estimation rather than class-A volumetric accuracy.

Dimension Verified value / relevance
Nominal capacity1,000 mL / 1 L
Footprint94 x 94 mm
Width b94 mm
Diameter d94 mm manufacturer drawing field
Catalog height h217.5 mm
Overall height222.5 mm
Drawing dimension h1183 mm, manufacturer-listed; do not assign extra meaning
Mouth inside diameter30 mm manufacturer field
All neck threadsGL 45
Graduation interval100 mL
Graduation range100–800 mL
Volumetric calibration toleranceNot specified
Cap-and-tubing installed heightDepends on chosen attachments

Dimension distinction: 217.5 mm is a catalog height field; 222.5 mm is the overall height. Neither is an installed-system clearance guarantee when taller HPLC delivery caps and tubing are fitted.

Retrace Code and Manufacturing-Lot Documentation

DWK states that the HYDRA bottle features a Retrace Code supporting manufacturing-lot traceability and a corresponding certificate. The general DWK certification page explains how printed bottle codes can be used for manufacturing-lot reference and document retrieval.

  • Find and record the printed Retrace Code from the delivered bottle or packaging.
  • Use DWK’s certificate process with the article number and required lot identifier.
  • Retain the retrieved manufacturing-lot documentation according to the quality system.
  • Distinguish manufacturing-lot traceability from solvent purity testing or HPLC method suitability.
  • Do not assume the bottle arrives with a separate printed Certificate of Analysis unless confirmed.

The Retrace Code is a production traceability feature. It does not certify the assembled system as sterile, pressure-rated, VOC-tight, or validated for a particular chromatographic solvent.

Chemical Compatibility, Mobile Phases, and VOC Exposure

A complete HPLC solvent supply system may contain DURAN glass, polypropylene or other cap resins, fluoropolymers, elastomeric seals, tubing, and solvent filters. The exact configuration governs compatibility; the base glass material cannot qualify every component.

Exposure or requirement Qualification consideration
Water and aqueous mobile phasesConfirm the method’s cleanliness, ion background, and glass compatibility requirements
Acetonitrile, methanol, or other organic mobile phasesVerify each polymer, cap liner, seal, and tubing against the actual solvent
Solvent gradients and mixed mobile phasesAssess combined solvents, additives, pH, time, and temperature
Aggressive acids / alkaline mediaReview glass and component chemical resistance; some conditions attack borosilicate glass
Volatile and flammable solventsUse ventilation, ignition-source controls, suitable caps, and spill containment
Unoccupied side necksClose with suitable GL 45 caps/plugs; do not leave ports open as a standard operating assumption
Trace-level inorganic analysisAssess blanks, extracts from caps/tubing, and any solvent contamination risk
Pressure/vacuum operationNot established as rated for pressure/vacuum; follow explicit equipment specification

VOC caution: DWK describes reduced risk of volatile organic compound escape when the necks are capped. This is a design benefit, not a quantitative emission guarantee or an unconditional airtight certification.

Autoclaving, Sterility, Pressure, and Mechanical Safety

The current 218505453 manufacturer page does not publish a specific autoclavability or sterile-status field. Although DURAN borosilicate 3.3 is used widely in heat-tolerant laboratory glassware, this does not automatically establish an approved autoclave procedure for the five-neck bottle with selected caps and tubing.

  • Exact sterilization cycle: Not established for the as-delivered HYDRA assembly.
  • Sterile packaging: No exact-SKU sterile supply claim verified.
  • Pressure/vacuum rating: Not established; do not operate as a pressurized reaction vessel.
  • Sealed heating: Avoid pressure buildup; use manufacturer-approved venting and process controls.
  • Thermal shock: Handle temperature changes and different cap materials cautiously.
  • Glass inspection: Check the base and all side-neck junctions for chips or cracks.
  • Protect personnel: Follow appropriate PPE and solvent spill response protocols.

Do not infer: A GL 45 bottle, even one made of borosilicate 3.3, is not automatically certified for autoclaving with all ports capped, pressurization, vacuum operation, or hazardous-material transport.

Recommended Manufacturer Accessories and Product Comparisons
Item How it differs from 218505453
218505453 HYDRA1 L square glass bottle; five GL 45 necks total; one/case
219900701 side-neck bottle2 L DURAN bottle with one extra GL 45 side neck (two necks total); manufacturer flyer item
Conventional single-neck GL 45 bottleOne access point; not a direct substitute for five-neck workflow
292312801 DURAN 3-port HPLC capGL 45 delivery-cap accessory for 3.2 mm OD tubing, suggested in DWK technical flyer
Other GL 45 HPLC capsPort/tubing/seal layouts vary; check the exact connection cap and tubing specifications

The 2 L side-neck bottle and the three-port HPLC cap are distinct products; no separate reservoir or accessory is part of the verified one-bottle 218505453 purchase unit. The caps used for actual HPLC operation should be selected and priced intentionally.

Receiving, Setup, and Laboratory QC Checklist
  1. Receiving: Confirm DURAN 218505453 and one square 1 L bottle.
  2. Inspect glass: Check all five necks, joints, base, rim, and threads for chips or fractures.
  3. Verify package contents: Count delivered caps and compare with the supplier’s order confirmation.
  4. Document the lot: Record the Retrace Code and retrieve applicable manufacturer certificate.
  5. Confirm fit: Check the 94 x 94 mm base and 222.5 mm overall height plus fittings and tubes.
  6. Define port use: Assign the connection and closure type for each of five GL 45 openings.
  7. Review solvent compatibility: Check glass, cap, seal, tube, and fitting materials.
  8. Prepare mobile phase: Follow the method’s filtration, degassing, and solvent purity requirements.
  9. Cap unused ports: Reduce contamination and vapor exposure, consistent with method and safety procedures.
  10. Purge the HPLC lines: Use instrument instructions and verify correct fluid delivery.
  11. Check graduations: Treat 100-800 mL scale as approximate, not calibrated dispense volume.
  12. Follow safety controls: Use appropriate containment, flammable-solvent storage, and waste procedures.
Cleaning, Solvent Changeover, and Reuse

Inspect and clean the bottle according to an approved laboratory process. Prior mobile phases may affect new samples through residue, carryover, extractables, or contaminated connection fittings. Cleaning of the glass body does not itself demonstrate cleanliness of caps, tubing, or filters.

  • Remove and handle connection components according to their manufacturer instructions.
  • Check all necks, especially side-neck junctions, for damage and retained contamination.
  • Use cleaning agents and rinse procedures compatible with borosilicate glass and each separate component.
  • Prevent residues from dried salts or buffers at rim and threaded surfaces.
  • Use method-qualified water or solvent rinses and system blanks where required.
  • Retain manufacturing-lot and cleaning records under the laboratory SOP.
  • Do not apply unverified pressurized cleaning or a fully capped steam-sterilization process.

The manufacturer’s care-and-maintenance reference provides general handling guidance; the laboratory must validate any reuse cycle relevant to its solvents and analytical performance.

Limitations and Claims Not Established for Exact SKU
  • Not five independent reservoirs: Five necks access one liquid chamber.
  • Not an active HPLC purging device: No pump, degasser, or programmed purge function is established.
  • Not guaranteed with five caps: Exact supplied cap count is unconfirmed.
  • Not an included three-port delivery cap: DWK lists 292312801 as a recommended accessory.
  • Not certified airtight: No complete-system VOC leakage or vapor-tight result established.
  • Not a pressure/vacuum vessel: No exact rating established.
  • Not a calibrated volumetric flask: 100-800 mL graduations are for estimating volume.
  • Not a sterile product claim: Sterility is not specified.
  • No verified autoclave cycle: Exact-SKU finished-system process not specified.
  • No universal solvent compatibility: Consider caps, liners, seals, and tubing.
  • No certified ion-extractables figure: Low-extractables statement is qualitative.
  • No cap-and-tubing clearance guarantee: Depends on assembled configuration.
  • No verified carton size or gross weight: Request current logistics information.
  • No claim of 1,000 mL marked range: Graduations stop at 800 mL.
Technical FAQs

What is DURAN 218505453?

A 1 L clear borosilicate glass 3.3 square HYDRA HPLC purging bottle with five GL 45 necks and a case quantity of one.

How many GL 45 necks are there?

Five: one main central opening and four side necks.

Are there five separate chambers?

No. All five necks communicate with the same 1 L reservoir.

What does HPLC purging mean?

Flushing the system’s lines so previous solvent is replaced by the new mobile phase; the HPLC system performs the flushing.

Does the bottle perform purging by itself?

No pump, automatic purge mechanism, or degasser is established as included.

Are five caps included?

DWK lists PP closure material but does not clearly specify how many caps come with the exact 218505453 order unit. Confirm before ordering.

Does it include HPLC tubing or connection caps?

No inclusion has been established for tubing, fittings, or the specialized three-port HPLC delivery cap.

What glass is used?

Clear DURAN borosilicate glass 3.3, identified by DWK with ISO 3585 and ASTM E438 Type I, Class A.

What is the square footprint?

94 x 94 mm.

How tall is the bottle?

DWK lists 217.5 mm catalog height and 222.5 mm overall height. Allow more clearance for installed caps and tubing.

What is the mouth inside diameter?

The manufacturer lists 30 mm.

What are the graduation marks?

White enamel, 100–800 mL in 100 mL steps.

Is the 1,000 mL bottle a calibrated volumetric vessel?

No calibrated volume tolerance is supplied. Nominal 1 L capacity is distinct from the highest 800 mL graduation.

What is the Retrace Code?

A code for manufacturing-lot traceability and corresponding manufacturer certificate lookup.

What is the three-port accessory part number?

DWK lists DURAN 292312801, a separate GL 45 HPLC cap for 3.2 mm outside-diameter tubing.

Does the bottle have low ion extractables?

DWK describes the borosilicate 3.3 glass as having a very low inorganic ion extractables profile; no exact numerical limit is established here.

Does it reduce solvent vapor exposure?

DWK states that a capped configuration reduces the risk of VOC escape and spills; no exact-system quantitative emission guarantee is established.

Can 218505453 be autoclaved?

The exact product listing does not specify an autoclave cycle or full-assembly rating. Confirm bottle, caps, and tubing suitability before any processing.

Is this supplied sterile?

No manufacturer sterile claim was confirmed in the reviewed exact-SKU data.

Can this be pressurized or placed under vacuum?

No pressure or vacuum rating is established for the exact five-neck assembly.

What is the purchase quantity?

One bottle per case.

How is this different from the 2 L side-neck model?

The DURAN 219900701 is a 2 L GL 45 bottle with one additional side neck, rather than this 1 L square five-neck HYDRA.