Skip to main content

Teknipure TM-MD47 TekniMop Microdenier Mop Cover with Elastic, Integrated Pad, 4″x7″ (Refills) (Case Qty.)

$1,151.13
SKU: TM-MD47 CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout
Type:
Dry Mop

Teknipure TM-MD47 TekniMop Microdenier Mop Cover with Elastic, Integrated Pad, 4″x7″ (Refills) (Case Qty.) - SOSCleanroom Standard Specification

The Teknipure TM-MD47 TekniMop™ Microdenier Mop Cover is a dry, non-sterile cleanroom mop cover designed for high-efficiency small-surface cleaning in controlled environments. Its microdenier polyester construction provides enhanced surface contact for particle, residue, and microorganism capture, while the integrated absorbent pad adds cushioning, liquid retention, and solution delivery without requiring a separate mop pad.

Capture + absorbency in one cover: TM-MD47 combines a microdenier outer cleaning layer with an integrated absorbent pad and elastic fit. This design supports effective contamination pickup, controlled liquid release, and secure installation on the TKM47 frame while eliminating the need to purchase and install a separate mop pad.

Specifications:
  • Part Number: TM-MD47
  • Product Type: Microdenier mop cover with elastic and integrated pad
  • Size: 4" x 7" (10 cm x 18 cm)
  • Material: Microdenier polyester
  • Pad: Integrated absorbent pad
  • Attachment: Elastic edge
  • Format: Dry
  • Sterility: Non-sterile
  • Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
  • Packaging: 10 covers/bag, 20 bags/case
  • Total Case Quantity: 200 covers/case
  • Compatible Frame: TKM47 TekniMop™ 4" x 7" Carbon Fiber Flat Mop Frame
Where TM-MD47 Fits in Controlled Environments

TM-MD47 is designed for small-surface cleaning applications where effective particle, residue, and contamination pickup is a higher priority than simple liquid delivery alone. The high-density microdenier construction increases surface contact with the area being cleaned, helping capture and retain contamination during controlled wiping and mopping procedures.

The integrated absorbent pad provides a soft, cushioned cleaning surface while increasing liquid-holding capacity for disinfectant application, spill control, and wet-cleaning procedures. Because the pad is enclosed within the mop-cover construction, there is no need to install a separate pad beneath the cover.

Typical program fit: Isolator and RABS/BSC cleaning, gloveboxes, pass-through chambers, equipment and work surfaces, benches, residue removal, particulate pickup, disinfectant application, spill control, and other small-surface contamination-control procedures.

TM-MD47 is supplied dry and non-sterile. Final suitability should be determined according to the target surface, cleaning chemistry, contamination type, required absorbency, sterile/non-sterile workflow, compatible hardware, and facility SOP.

About the Manufacturer:

Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, interchangeable handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, semiconductor and microelectronics manufacturing, optics, aerospace and defense, compounding pharmacies, laboratories, and other controlled environments.

Within the TekniMop™ mop-cover family, Teknipure offers polyester, microfiber, and microdenier constructions designed around different cleaning objectives. Microdenier options emphasize high surface contact and contamination capture, while integrated-pad designs add absorbency and cushioning without requiring a separate pad component.

TM-MD47 Features:
  • Microdenier polyester cleaning surface
  • 4" x 7" format for small-surface cleaning
  • Integrated absorbent pad
  • Pad enclosed within the cover to reduce direct particle generation from the pad material
  • Elastic edge for quick and secure installation
  • High surface-contact area for enhanced particle and residue pickup
  • Good absorbency and liquid retention
  • Controlled disinfectant release for uniform surface wetting
  • Compatible with IPA, sporicidal agents, and common cleanroom disinfectants
  • Dry configuration allows facility-controlled chemistry selection
  • Non-sterile format
  • Compatible with the TKM47 TekniMop™ carbon fiber flat mop frame
TM-MD47 Benefits:
  • Enhanced contamination pickup: Ultra-fine microdenier construction increases surface contact to support effective capture of particles, residues, and other contamination.
  • Integrated-pad convenience: The built-in absorbent pad eliminates the need for a separate mop pad, simplifying setup and reducing the number of system components.
  • Improved liquid handling: The absorbent pad provides additional fluid-holding capacity for disinfectant application, wet cleaning, and spill-control procedures.
  • Controlled solution release: The cover is designed to distribute cleaning or disinfecting solution across the surface while maintaining consistent contact.
  • Secure frame fit: Elastic edging helps keep the cover positioned securely on the compatible TKM47 frame during cleaning.
  • Flexible chemistry selection: The dry format allows facilities to choose the cleaning or disinfecting chemistry and saturation level required by their SOP.
  • Reduced component handling: Integrating the pad into the cover removes a separate assembly step and reduces an additional potential contamination source.
Common Applications:
  • Cleaning isolators and RABS/BSC areas
  • Cleaning gloveboxes and pass-through chambers
  • Cleaning equipment surfaces, work surfaces, and benches
  • Reaching confined and difficult-to-access areas
  • Particle and residue removal
  • Precleaning before disinfectant application
  • Application of disinfectants and sanitizers
  • Controlled surface wetting
  • Spill control and liquid pickup
Best-Practice Use:
  • Install securely: Fit the elastic cover fully over the compatible TKM47 frame so the integrated pad remains evenly positioned beneath the cleaning surface.
  • Select the appropriate chemistry: Because TM-MD47 is supplied dry, apply the cleaning or disinfecting solution according to the chemistry manufacturer's instructions and facility SOP.
  • Control saturation: Wet the cover and integrated pad sufficiently for the procedure without unnecessary oversaturation or dripping.
  • Use controlled strokes: Follow the directional wiping or mopping pattern established by the facility and avoid moving contamination back into previously cleaned areas.
  • Maintain surface contact: Allow the cushioned integrated pad and microdenier surface to maintain even contact rather than relying on excessive downward pressure.
  • Observe required contact time: When applying disinfectants or sanitizers, maintain the required surface wetness and contact time specified by the chemistry manufacturer and facility procedure.
  • Change covers as required: Replace the cover according to contamination load, room transition, surface area, chemistry condition, or other changeout criteria established by the facility.
  • Follow non-sterile material controls: TM-MD47 is supplied non-sterile and should be introduced and used according to the facility's material-transfer and contamination-control procedures.
Selection Notes (TM-MD47 vs. Other TekniMop™ Options)
  • TM-MD47: Choose this microdenier version when enhanced particle and residue pickup, high surface contact, and an integrated absorbent pad are priorities.
  • TM-QP47: Select the 2-ply polyester cover when liquid retention, solution delivery, and general-purpose wet cleaning are the primary requirements.
  • TM-PFM-47: Select the microfiber knit cover with integrated foam pad when a microfiber cleaning surface and cushioned contact are preferred.
  • TM-PFM70G-47: Select the presaturated microfiber option when a ready-to-use 70% IPA configuration is preferred.
  • Microdenier vs. 2-ply polyester: Microdenier emphasizes surface contact and contamination capture, while 2-ply polyester places greater emphasis on liquid handling and general wet-cleaning performance.
  • Integrated pad vs. separate pad: TM-MD47 incorporates the absorbent pad into the cover itself, simplifying assembly and eliminating the need to source a separate pad.
Compatible TekniMop™ Products

Compatible Carbon Fiber Frame

  • TKM47: 4" x 7" carbon fiber flat mop frame for small-surface cleaning, equipment, isolators, RABS, and confined areas
Building a TM-MD47 TekniMop™ System

The TM-MD47 is the microdenier mop-cover component of a modular TekniMop™ small-surface cleaning system. Pair the cover with the compatible TKM47 carbon fiber frame and select a TekniMop™ carbon fiber handle according to the reach required for the cleaning procedure.

System configuration:
TM-MD47 Microdenier Mop Cover with Integrated Pad + TKM47 Carbon Fiber Frame + Compatible TekniMop™ Carbon Fiber Handle

Select the handle according to required reach and operator position, then apply the cleaning chemistry and saturation level appropriate for the surface, contamination type, and facility procedure.

Workflow note: TM-MD47 is supplied dry and non-sterile. The integrated pad is already built into the cover, so no separate mop pad is required. Cleaning chemistry, saturation, material transfer, cover changeout, use, and disposal should follow the applicable facility SOP.

Notes: Looking for application guidance or qualification context for the Teknipure TM-MD47 TekniMop™ Microdenier Mop Cover with Integrated Pad? Open the SOSCleanroom Technical Vault tab above for detailed small-surface cleaning guidance, microdenier material selection, mop-cover changeout considerations, system configuration, cleaning technique, chemistry application, and compatibility information.

SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.

Product page updated: Oct. 26, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
Microdenier Polyester 4" x 7" Integrated Absorbent Pad Elastic Attachment Dry Non-Sterile ISO 5–8 200 Covers/Case

Teknipure TekniMop™ TM-MD47: high-contact microdenier cleaning with an integrated absorbent pad

The Teknipure TekniMop™ TM-MD47 is a 4" x 7" dry, non-sterile microdenier polyester mop cover with an elastic attachment and integrated absorbent pad. Designed for compact critical-surface cleaning, its ultra-fine microdenier polyester working surface provides high surface contact for contamination pickup, while the built-in absorbent pad adds liquid-holding capacity and cushioned surface contact without requiring a separate pad.

Operations takeaway: TM-MD47 combines the high-contact cleaning surface of microdenier polyester + liquid capacity of an integrated absorbent pad + fast elastic attachment in one cover. It is particularly useful when contamination pickup and controlled chemistry delivery are both important.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer: Teknipure
  • Product: TekniMop™ Microdenier Mop Cover with Elastic & Integrated Pad
  • Part number: TM-MD47
  • Cover size: 4" x 7" (10 cm x 18 cm)
  • Cleaning material: Microdenier polyester
  • Internal pad: Integrated absorbent pad
  • Attachment style: Elastic
  • Condition: Dry
  • Sterility: Non-sterile
  • Cleanroom environment: Manufacturer lists ISO Class 5–8
  • Packaging: 10 covers/bag, 20 bags/case
  • Total case quantity: 200 covers/case
  • Compatible frame: TKM47, 4" x 7" carbon fiber flat mop frame
  • Dry-cover shelf life: 5 years from date of manufacture
  • Storage: Clean, dry environment at 59°F (15°C) to 85°F (30°C)

Microdenier construction: engineered around contamination capture

The defining feature of TM-MD47 is its high-density microdenier polyester cleaning surface. Teknipure positions the ultra-fine construction for high surface contact, particle pickup, contamination control, and consistent solution distribution.

  • High surface contact: ultra-fine material structure increases interaction between the cover and the surface being cleaned.
  • Particle pickup: designed to capture and retain fine particulate contamination.
  • Residue removal: supports mechanical removal of process residues from critical surfaces.
  • Contamination pickup: high-contact material construction supports physical removal during controlled cleaning.
  • Low-linting: supports contamination-control use in critical environments.

Cleaning principle: Microdenier is valuable because cleaning is not only about putting chemistry onto a surface. The mop must also provide an effective mechanical interface for capturing and removing contamination.


Low-linting does not mean lint-free

Teknipure describes its microdenier and microfiber mop-cover platform as low linting for contamination-control applications. This is the appropriate way to understand the material: it is designed to minimize contribution of unwanted contamination while providing effective pickup performance.

Terminology note: No textile mop cover should be treated as literally particle-free or lint-free. Use low-linting or the applicable manufacturer performance terminology when evaluating the product for a controlled process.


Integrated absorbent pad: built-in liquid capacity without a separate pad component

Integrated absorbent pad: Built into the cover to provide additional liquid-holding capacity and cushioned surface contact without requiring a separate pad.

  • Additional liquid capacity: supports cleaning, compatible disinfectant application, and appropriate spill-control tasks.
  • Integrated construction: no separate absorbent pad must be installed before use.
  • Simplified setup: fewer individual components reduce preparation and changeover steps.
  • Reduced component handling: eliminates one additional loose component from the cleaning workflow.
  • Cushioned surface contact: provides compliant backing beneath the microdenier working face.
  • Surface conformity: the cushioned construction can help the cleaning face maintain contact across surfaces with moderate geometric variation.

System simplification: The integrated pad turns the cleaning textile and absorbent backing into one consumable assembly. The cover is installed and changed as a complete unit rather than requiring a separate pad component.


Fully enclosed absorbent pad: keeping the internal component out of the cleaning environment

Teknipure states that the integrated absorbent pad is covered on all sides. The internal pad therefore performs its liquid-management and cushioning functions while the microdenier polyester exterior remains the controlled surface presented to the cleaning environment.

  • External cleaning interface: microdenier polyester remains the surface that directly contacts the target.
  • Internal absorbent function: the pad retains solution within the cover assembly.
  • Enclosed construction: the absorbent pad is covered rather than intentionally exposed to the cleaning environment.
  • Unified changeout: the cleaning face and absorbent component are replaced together.

Condition-control rule: If physical damage exposes the internal pad, compromises the elastic perimeter, or interferes with the microdenier working surface, remove the cover from service.


Elastic attachment: fast installation on the TKM47 frame

Unlike the pocket-style covers in other TekniMop™ families, TM-MD47 uses an elastic edge to secure the cover around the compatible TKM47 carbon fiber frame. Teknipure positions the elastic design for quick installation, secure fit, reduced changeover time, and consistent cover positioning.

  • Quick fit: elastic perimeter simplifies installation and removal.
  • Secure retention: holds the cover around the frame during cleaning.
  • Consistent positioning: helps maintain the intended cleaning face over the frame.
  • Faster changeover: useful when covers must be replaced between areas or after defined cleaning limits.

Attachment distinction: TM-MD47 is an elastic integrated-pad cover, not a pocket cover. Attachment style is part of the SKU configuration and should be documented correctly in product selection and SOPs.


TKM47 compatibility: a matched 4" x 7" carbon fiber cleaning system

Teknipure specifically lists the TKM47 4" x 7" carbon fiber flat mop frame as the compatible frame for TM-MD47. The matched footprint creates a compact system suited to small critical surfaces, equipment, isolators, cabinets, pass-throughs, and other areas where a larger mop would reduce maneuverability.

  • Cover: TM-MD47, 4" x 7"
  • Frame: TKM47 carbon fiber flat mop frame, 4" x 7"
  • Cleaning material: Microdenier polyester
  • Attachment: Elastic perimeter
  • Pad: Integrated absorbent pad
  • Handle: Select the compatible carbon fiber handle according to required reach and operator control

System principle: Cover = direct cleaning interface and liquid management. Frame = access and footprint. Handle = reach and leverage. Chemistry + technique = cleaning process.


Dry configuration: chemistry remains under facility control

TM-MD47 is supplied dry, allowing the facility to introduce the compatible cleaning or disinfecting chemistry required by its procedure. The integrated absorbent pad provides additional liquid-holding capacity after wetting.

  • Chemistry flexibility: use with the facility-approved compatible solution.
  • Loading control: the facility defines how much chemistry is introduced.
  • Integrated absorbency: the pad provides additional fluid-holding capacity after wetting.
  • Application flexibility: supports cleaning, compatible disinfectant application, residue removal, and appropriate spill-management procedures.

Process-control rule: For controlled cleaning or disinfection, define the chemistry, concentration, wetting method, target loading, required surface wetness, coverage area, contact requirement, and cover change-out point.


Chemical compatibility: IPA, sporicides & common cleanroom disinfectants

Teknipure identifies TM-MD47 for use with IPA, sporicidal products, and common cleanroom disinfectants. Chemistry selection should still be evaluated according to the specific formulation, concentration, target surface, exposure conditions, and facility procedure.

Chemical-control rule: General compatibility does not mean every chemistry, concentration, exposure time, or surface combination has been universally qualified. Confirm the specific chemistry + concentration + surface + cleaning method required by the facility.


Solution loading: the integrated absorbent pad increases liquid capacity

Because TM-MD47 contains an integrated absorbent pad, the complete cover can retain more liquid than the outer microdenier cleaning layer alone. This supports solution application and spill management while making controlled wetting an important process variable.

  • Under-loading: may reduce the ability to maintain the required surface wetness.
  • Controlled loading: allows the integrated pad to function as a solution reservoir while the microdenier face distributes chemistry.
  • Over-loading: can add unnecessary weight and increase dripping, runoff, or uncontrolled liquid transfer.
  • Progressive depletion: available liquid decreases as chemistry transfers from the cover to the cleaning surface.

Useful mental model: The integrated pad stores. The microdenier face contacts, captures, and distributes. Both functions need to remain controlled during the cleaning cycle.


Cushioned contact: useful across surfaces with moderate geometric variation

The integrated absorbent pad provides a soft, cushioned backing beneath the microdenier cleaning face. This can help the working surface maintain useful contact as surface geometry changes.

  • Flat surfaces: provides broad microdenier contact across the cleaning face.
  • Slight surface variation: cushioning can help the material maintain contact as geometry changes.
  • Equipment surfaces: compact 4" x 7" footprint supports maneuverability around controlled equipment.
  • Confined environments: small frame geometry helps reach areas where larger mop systems are impractical.

Technique point: Cushioning can support surface conformity, but the operator must still maintain appropriate frame orientation and pressure. The integrated pad does not compensate for poor mop positioning or an unsuitable frame angle.


What TM-MD47 is designed to support (typical use cases)
  • Cleaning isolators and RABS
  • Cleaning biological safety cabinets
  • Cleaning gloveboxes and pass-through chambers
  • Cleaning equipment surfaces, work surfaces, and benches
  • Reaching confined and difficult-to-access areas with compatible mop hardware
  • Precleaning before disinfectant application
  • Application of compatible disinfectants and sanitizers
  • Removal of process residues
  • Fine-particle and contamination pickup
  • Spill-control management
  • Cleaning smooth or moderately uneven critical surfaces

Particle pickup vs. chemistry delivery: TM-MD47 performs both roles

TM-MD47 is useful because the cleaning assembly is not dependent on a single mechanism. The microdenier polyester outer surface provides high-contact contamination pickup, while the integrated absorbent pad provides liquid capacity for cleaning or compatible disinfectant application.

  • Mechanical removal: surface contact helps capture particles and residues.
  • Liquid delivery: retained chemistry is released through the working surface during cleaning.
  • Combined cleaning: the cover can interact mechanically with contamination while distributing selected chemistry.
  • Process-dependent balance: some procedures emphasize pickup; others emphasize chemistry delivery and wetting.

Cleaning principle: Chemistry does not replace mechanical removal, and mechanical pickup does not replace required chemistry. Effective critical cleaning can depend on both the solution and the surface-contact mechanism.


Cleaning technique: capture contamination without redistributing it
  • Start with a clean cover: install TM-MD47 on the prepared TKM47 frame.
  • Load chemistry according to procedure: use the approved solution and defined wetting method.
  • Establish full-face contact: orient the frame so the microdenier working surface remains against the target.
  • Use systematic overlapping passes: maintain complete coverage without random scrubbing.
  • Progress cleaner-to-less-clean where applicable: reduce the potential for contamination redistribution.
  • Avoid unnecessary backtracking: do not repeatedly move a loaded cover across previously treated surfaces.
  • Monitor cover loading: recognize when captured contamination or residue has accumulated on the working surface.
  • Monitor solution delivery: replace or reprepare according to the SOP when the cover no longer maintains required wetness.

Contamination-control principle: A clean cover removes contamination. An overloaded cover can redistribute it. Define the transition point in the cleaning procedure rather than leaving cover change-out entirely to operator judgment.


Change-out triggers: when the microdenier cover has completed its cleaning cycle
  • Defined surface-area limit: the SOP assigns a maximum cleaning area per cover.
  • Zone transition: a fresh cover is required before moving into another defined area.
  • Visible contamination: the microdenier face accumulates obvious soil, particles, or residue.
  • Insufficient wetness: the cover can no longer provide the required chemistry delivery.
  • Excessive loading: retained contamination may begin to compromise pickup performance.
  • Physical damage: elastic, outer material, or integrated pad assembly becomes compromised.
  • Exposed internal material: damage reveals any portion of the enclosed absorbent pad.
  • Loss of secure fit: the cover no longer remains correctly positioned on TKM47.
  • Process transition: another cleaning step or chemistry requires a fresh consumable.

Simple rule: A clean microdenier surface captures contamination. An overloaded microdenier surface can redistribute it.


Best-practice use (microdenier elastic integrated-pad cover)
  1. Verify the SKU: confirm TM-MD47 when the procedure requires the dry, non-sterile 4" x 7" microdenier integrated-pad configuration.
  2. Inspect the cover: check the microdenier surface, elastic perimeter, enclosed pad assembly, and overall cover for visible damage.
  3. Prepare the TKM47 frame: ensure reusable hardware meets the facility’s cleanliness requirements.
  4. Install the elastic cover: position it evenly around the frame so the working face remains centered and secure.
  5. Apply approved chemistry: wet according to the defined solution, concentration, method, and target loading.
  6. Avoid unnecessary over-saturation: use the integrated absorbent pad as a controlled reservoir rather than loading excess liquid.
  7. Establish full surface contact: adjust the frame so the microdenier face remains engaged with the target.
  8. Use controlled overlapping passes: follow the defined cleaning pattern and zoning sequence.
  9. Monitor contamination, wetness, and physical condition: change the cover at the first applicable process trigger.
  10. Handle after use according to procedure: follow facility requirements based on the chemistry and contamination encountered.

TM-MD47 vs. other 4" x 7" TekniMop™ cover technologies
  • TM-QP47: 2-ply polyester pocket cover — dry pocket-style configuration.
  • TM-MD47: microdenier polyester cleaning face + integrated absorbent pad + elastic attachment.
  • TM-PFM-47: microfiber knit pocket cover + integrated foam pad.
  • TM-PFM70G-47: microfiber knit pocket cover + integrated foam pad + factory-applied 70% IPA.

Selection principle: Do not choose solely by frame size. These 4" x 7" covers use different cleaning materials, attachment methods, pad constructions, and chemistry-delivery configurations. Select the exact SKU that matches the process.


TM-MD47 selection logic
  • Choose TM-MD47 when: the process requires a microdenier polyester cleaning surface for compact controlled-environment cleaning.
  • Choose it when built-in absorbency matters: the integrated absorbent pad provides additional liquid-holding capacity without requiring a separate pad.
  • Choose it when cushioned surface contact is useful: the integrated pad provides compliant backing beneath the microdenier face.
  • Choose it when fast cover changes matter: the elastic attachment provides quick installation on TKM47.
  • Choose it when chemistry flexibility matters: the dry format allows facility-controlled application of compatible chemistry.
  • Choose another configuration when: the procedure specifically requires a pocket attachment, factory presaturation, sterile status, or another cleaning-material technology.

Simple decision rule: If the process calls for microdenier polyester + integrated absorbency + elastic attachment + facility-selected chemistry on the 4" x 7" TKM47 platform, TM-MD47 is the purpose-built configuration.


Storage & shelf life
  • Storage environment: Clean and dry
  • Published storage temperature: 59°F (15°C) to 85°F (30°C)
  • Dry mop-cover shelf life: 5 years from date of manufacture

Inventory-control point: Use current product labeling and lot-specific records for receiving and shelf-life control. The manufacture-based shelf life does not establish a reuse allowance, post-wetting hold time, or opened-package cleaning limit.


Misuse controls & selection cautions
  • Do not treat TM-MD47 as sterile: this SKU is supplied non-sterile.
  • Do not treat TM-MD47 as presaturated: this SKU is supplied dry.
  • Do not add a separate pad: an absorbent pad is already integrated into the cover.
  • Do not describe the internal pad as polyester unless current manufacturer documentation specifically requires that terminology: use the broader integrated absorbent pad description.
  • Do not describe it as a pocket cover: TM-MD47 uses an elastic attachment.
  • Do not assume low-linting means lint-free: textile cleaning materials can still contribute some fibers or particles.
  • Do not over-saturate without process justification: excess liquid can increase weight, dripping, and uncontrolled solution transfer.
  • Do not continue using an overloaded cover: high capture capability does not mean unlimited contamination capacity.
  • Do not assume broad chemical compatibility is universal: validate the specific chemistry and use conditions.
  • Do not use on an unintended frame solely because dimensions appear similar: Teknipure specifically designates TKM47 as the compatible frame.

Why source TekniMop™ through SOSCleanroom
  • Cover-technology selection: SOSCleanroom can help distinguish between 2-ply polyester, microdenier, and microfiber configurations instead of treating every 4" x 7" mop cover as equivalent.
  • System-level selection: We can help align the cover with the correct TKM47 frame, carbon fiber handle, and intended cleaning chemistry.
  • Exact-SKU control: Cleaning material, attachment style, integrated-pad construction, sterility, and presaturation can vary significantly between otherwise similar TekniMop™ covers.
  • Documentation support: We can help customers identify current manufacturer technical documentation for purchasing, qualification, and SOP review.
  • One-cart procurement: Source TekniMop™ covers and hardware alongside disinfectants, IPA, gloves, wipers, and other critical-environment consumables.

Manufacturer documentation (authoritative references)
  • Teknipure TM-MD47 product page: Click Here
  • TekniMop™ Small Surface & Isolator Cleaning Tools Technical Data Sheet: Click Here

Documentation note: Use current manufacturer documentation, exact product labeling, and applicable lot records for final purchasing and qualification decisions.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.