Skip to main content

Texwipe TX726 CrushTube Swab 91% IPA 9% DIW Solution

$71.75
SKU: TX726 BOX Stock Item
(No reviews yet)
Availability:
Stock Item
Shipping:
Calculated at Checkout
Type:
Pre-Wet Swab
Family:
CrushTube
Material:
Polyester

Texwipe TX726 CrushTube™ 91% IPA / 9% DIW Precision Cleaning Swab

Texwipe TX726 CrushTube™ is a non-sterile precision-cleaning swab with a sealed-in, point-of-use solvent reservoir. A 100% nonwoven polyester head sits above an internal glass vial containing 91% USP-grade isopropyl alcohol (IPA) / 9% deionized water (DIW). The liquid stays separate from the head until the inner vial is crushed; activation wets the tip when the operator is ready to clean. The single-use format is intended for localized cleaning of grooves, slots, ion emitter tips, adhesive buildup, and optical assemblies.

The main selection advantage is an integrated swab-and-solvent system: no separate cleaning cup or solvent bottle is required at the point of use. TX726 is intended for small features and targeted solvent delivery, not as a substitute for a full-size cleanroom wiper when broad surface coverage is required.

Ordering note: Manufacturer part number TX726 is supplied as 50 individually sleeved swabs per box or 10 boxes per case (500 swabs). Confirm whether the selected SOSCleanroom purchasing option is BOX or CASE before ordering.

Specifications:
  • Manufacturer / part number: Texwipe TX726, CrushTube™ swab
  • Product format: Non-sterile, point-of-use solvent-activated swab
  • Head: 100% nonwoven polyester; 8.3 mm width, 8.3 mm thickness, 10.0 mm length
  • Internal solvent: USP-grade 91% isopropyl alcohol / 9% DIW
  • Reservoir: 0.5 mL ampule (manufacturer technical-datasheet design value)
  • Vial / exterior: Soda-lime Type III USP glass inner vial inside a protective polybutyrate sleeve
  • Overall swab length: 47.6 mm (1.874 in.)
  • Outer sleeve dimensions: 8.3 mm width, 8.3 mm thickness, 37.6 mm handle length (current linked Texwipe TDS)
  • Individual presentation: Cleanroom-compatible peel-apart sleeve; lot coded
  • Manufacturer packaging: 50 swabs/box; 10 boxes/case; 500 swabs/case
  • Manufacturer-published shelf life: 5 years from manufacture; follow printed identification and site storage controls
  • Manufacturer storage range: 15°C to 30°C (59°F to 86°F)
How the CrushTube™ Design Works

The inner glass vial contains the IPA/DIW solution, isolated inside a protective external tube. The swab tip is not continuously immersed in liquid during storage. When the ampule is crushed at the point of use, solvent is released into the polyester head for a localized cleaning operation.

This arrangement helps teams standardize the supplied liquid chemistry and avoid a second solvent container for small tasks. It does not establish a guaranteed residue limit, sterilization status, or compatibility with every coating or device. Site qualification must still address surface materials, solvent exposure, inspection criteria, and work instructions.

Where it adds value: TX726 is a deliberate choice when an operator needs a portable solvent-bearing tip rather than separate bulk IPA handling. Follow Texwipe instructions and the site-specific SOP for controlled ampule activation and disposal.

About the Manufacturer:

Texwipe manufactures contamination-control consumables and publishes SKU-specific product information, technical datasheets, and safety documentation. For TX726, its documentation identifies the swab-head composition, liquid formulation, vial materials, dimensional envelope, packaging hierarchy, and five-year shelf life. The product is lot coded for traceability.

SOSCleanroom customers can use those documents to define receiving requirements and determine whether the integrated CrushTube format fits an existing cleaning procedure. The manufacturer records—not generic product-family assumptions—should control any qualification or substitution decision.

TX726 Features:
  • Integrated point-of-use IPA: The specified liquid stays isolated in the ampule until activation.
  • 100% polyester nonwoven tip: Provides the manufacturer-identified cleaning contact material.
  • Individual peel-apart packaging: Allows a single swab to be introduced when needed.
  • Compact tool format: 47.6 mm nominal overall length for short-reach, localized tasks.
  • Lot coding: Supports identification of the supplied product lot.
  • Published storage and shelf life: Five years from manufacture when stored under appropriate conditions.
TX726 Benefits:
  • Point-of-use solvent availability: No separate IPA bottle is needed for this specific swab operation.
  • Controlled cleaning workflow: Activation can be defined as a step in a site cleaning method.
  • Small-feature access: The 8.3 mm-wide head supports targeted contact on accessible recesses rather than broad wipe-downs.
  • Qualification transparency: Customers can compare the actual 91% IPA chemistry, tip materials, dimensions, and protective packaging against process requirements.
  • Purchasing clarity: A box contains 50 separate swabs, not 50 bulk-wetted tips in one pouch.
Common Applications:
  • Solvent cleaning and maintenance of ion emitter tips
  • Cleaning grooves, tracks, slots and other small spaces
  • Removing adhesive buildup at a localized contact point
  • Solvent cleaning of optical assemblies where the process permits IPA exposure
  • Small maintenance or bench-cleaning operations requiring a single individually packaged swab
Best-Practice Use:
  • Check the work instruction: Confirm the surface, equipment state, and permitted 91% IPA chemistry before opening the sleeve.
  • Activate only when ready: Follow the manufacturer-approved CrushTube procedure for releasing the inner-vial liquid; avoid damaging the external sleeve or exposing glass.
  • Control contact and wetness: Use the wetted head within the approved cleaning method. The reservoir is designed for localized application, not large-area saturation.
  • Manage the loaded tip: Do not use a contaminated tip on a clean area; replace the single-use product according to the SOP.
  • Follow IPA precautions: Keep away from heat, sparks and open flames, maintain ventilation, and follow the current TX726 Safety Data Sheet and facility procedures.
  • Dispose as directed: Follow the site waste procedure for a used solvent-bearing swab containing an activated glass ampule.
Selection Notes (TX726 vs. Other Options)
  • TX726 versus a dry swab plus separate IPA: Choose TX726 when the built-in, specified solution and individually packaged point-of-use format are beneficial; choose a separately supplied swab and compatible solvent when a different chemistry or loading method is required.
  • TX726 versus pre-wetted wipers: Use a wiper for larger surface coverage; TX726 provides a compact tip for localized features.
  • Optical and coated surfaces: Texwipe lists optical assemblies as an application, but the substrate, coating, and solvent contact procedure still require process approval.
  • Regulated or sterile workflows: TX726 is non-sterile; manufacturer use examples do not independently establish that it meets the requirements of a particular facility or regulated process.
  • Purchasing and logistics: Order by the desired box/case configuration. IPA-containing products need shipping and storage handling determined from current applicable regulations and carrier arrangements, not an outdated storefront shipping label.
Link to Texwipe Technical Datasheet: Click Here
Manufacturer Documentation and Related Product Information

Notes: For supporting technical measurements, compatibility/qualification considerations, shelf life, and safe handling, review the Technical Vault and the Texwipe documents linked above.

Questions about the correct configuration or supporting documentation? Email Sales@SOSsupply.com or call (214) 340-8574.

Content reviewed and revised: November 18, 2026. This date refers to the prepared content, not to publication on the live website.

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom). All rights reserved.

The Technical Vault By SOSCleanroom
TX726 CrushTube™ 91% IPA / 9% DIW Nonwoven Polyester Point-of-Use Precision Cleaning Lot-Coded Packaging

TX726 CrushTube™: technical selection and operating principle An integrated solvent reservoir for localized cleaning

Texwipe TX726 is a non-sterile, single-use polyester-tip swab equipped with an enclosed glass ampule containing USP-grade 91% IPA / 9% DI water. Its solvent is stored separately from the head before activation, then released to saturate the swab tip. This differs materially from a dry swab manually dipped into an external bottle and from a wiper supplied continuously pre-wetted throughout storage.

Technical takeaway: Specify TX726 when point-of-use liquid delivery and access to small features are important. The swab does not establish a validated cleaning result on its own; the approved surface, contact method, equipment state, and verification criteria remain part of the site process.


Construction and liquid-delivery system
  • Tip material: 100% nonwoven polyester; the manufacturer describes a polyester head, not foam or cotton.
  • Internal liquid ampule: Soda-lime glass identified by Texwipe as Type III USP glass.
  • Protective outside: Polybutyrate external vial/sleeve surrounding the internal glass ampule.
  • Liquid formulation: 91% USP-grade isopropyl alcohol / 9% DIW; composition is a product-design claim, not a disinfection-efficacy claim.
  • Reservoir design volume: 0.5 mL, as listed for TX726 in the manufacturer technical datasheet.
  • Activation: Crushing the inner ampule releases liquid to the polyester tip for point-of-use cleaning.
  • Presentation: Each swab is individually packaged in a cleanroom-compatible peel-apart sleeve and lot coded for traceability.

Process control: Treat ampule activation, swab application, and disposal as separate written steps. Follow the manufacturer instructions and site-approved procedure; avoid introducing loose glass fragments or unmanaged solvent-bearing waste.


Physical characteristics: TX726 exact-SKU data
  • Head width: 8.3 mm (0.327 in.)
  • Head thickness: 8.3 mm (0.327 in.)
  • Head length: 10.0 mm (0.394 in.)
  • Handle / sleeve width: 8.3 mm (0.327 in.)
  • Handle / sleeve thickness: 8.3 mm (0.327 in.)
  • Handle length: 37.6 mm (1.480 in.)
  • Overall swab length: 47.6 mm (1.874 in.)
  • Handle color: Transparent
  • Manufacturer packing unit: 50 individually packaged swabs/box; 10 boxes/case; 500 swabs/case.

These dimensions reflect Texwipe’s currently linked Specialty Swabs TDS, which agrees with its current TX726 web specification. Use head width and the contact geometry to screen fit; overall length and outside sleeve dimensions matter for access and handling. Dimensional compatibility with a specific recess or tool still requires site evaluation.


Documentation and analytical evidence: what the manufacturer actually publishes

The manufacturer TDS gives detailed geometry, construction, solvent formulation, packaging, shelf life, storage range, and a 0.5 mL reservoir design note for TX726. Its separate table of typical ionic contamination measurements is headed for TX730, a different precision nylon tool. Those TX730 values cannot be reassigned to TX726.

  • Verified for TX726: Liquid composition, construction, dimensions, individual packaging, 50/box and 500/case, lot coding, storage range, shelf life, and point-of-use activation.
  • Not established by the currently linked TDS: TX726-specific particle release, fiber release, nonvolatile-residue numerical values, extractable ions, or a guaranteed cleaning yield.
  • Manufacturer distinction: Texwipe describes technical-datasheet analytical figures as typical analyses rather than specification limits. Where a site has numeric residue or particle acceptance limits, request exact-SKU evidence directly from Texwipe rather than treating another swab model as representative.
  • Quality documentation: Capture the manufacturer part number and received lot code, control the revision of the TDS/SDS used for qualification, and request any required batch-specific support from the supplier before making a lot-acceptance claim.

Evidence boundary: Application listings, cleanroom-compatible packaging, and the manufacturer’s company-level quality registrations are not proof that TX726 meets a particular facility’s ISO-classification, sterility, USP compounding, or batch-specific residue requirements.


Storage, shelf life and receiving controls
  • Shelf life: Texwipe publishes 5 years from date of manufacture in its TX726 specialty swab TDS.
  • Storage temperature: 15°C to 30°C (59°F to 86°F) ambient conditions in the TDS.
  • Protection: The TX726 SDS directs cool, dry, ventilated storage away from ignition sources and oxidizing materials; follow original packaging and site hazardous-material controls.
  • Receiving check: Confirm TX726 identification, sealed individual peel-apart sleeves, correct quantity/box and cases, and lot identification. Handle suspected ampule or liquid leakage per the site incident procedure.
  • Expiration management: Determine release/use dates from manufacturer markings and receiving records. A generic five-year publication is not a certificate for an individual lot.

SDS: flammable IPA and operator protection

Texwipe’s TX726 Safety Data Sheet classifies the contained IPA liquid as Flammable Liquid Category 2, Eye Irritation Category 2A, and Specific Target Organ Toxicity (single exposure), Category 3 (narcotic effects). Its signal word is Danger. The SDS directs ignition-source control, adequate ventilation, vapor avoidance, and appropriate hand and eye protection.

  • Ignition: Keep the product away from hot surfaces, sparks, open flame, and smoking; consider static-discharge controls appropriate to the workplace.
  • Ventilation and exposure: Follow the SDS and industrial hygiene assessment for IPA vapor, including local exhaust or other controls if needed.
  • Eyes and skin: Select protective equipment from the hazard assessment and current SDS. The SDS describes eye irritation and includes exposure-response instructions.
  • Storage and transport: Follow applicable law, current SDS, and carrier requirements; do not infer a universal shipping method from historical ORM-D text.
  • Waste: Follow the site procedure for contaminated solvent-bearing products and the activated glass-containing ampule.

Important distinction: The SDS liquid hazard classification is not by itself a parcel-shipping classification for every pack size and route. Logistics needs a current transport determination for the actual ordered configuration.


Supported applications and procedure boundaries
  • Ion emitter tips: Texwipe lists solvent cleaning and maintenance of emitter tips. Follow the equipment manufacturer’s de-energization, tip-care, and restart instructions; do not treat a general swab listing as an equipment service manual.
  • Slots, tracks and grooves: The head is intended for small-feature solvent cleaning, subject to tool and access dimensions.
  • Adhesive buildup: Texwipe includes adhesive removal as an application. Effectiveness depends on the adhesive, the substrate, and the approved IPA method.
  • Optical assemblies: Texwipe lists optical cleaning. Validate IPA contact, optical coating durability, wiping pressure, and inspection for the actual assembly.
  • Broader surfaces: The compact tip and 0.5 mL reservoir are not a large-spill or large-panel cleaning solution; select a suitable wiper and documented solution method for larger coverage.

Best-practice sequence for a controlled cleaning method
  1. Before opening: Verify the surface, equipment state, compatible solvent, operator PPE and the approved work instruction.
  2. Open and activate: Introduce the individually packaged swab per site transfer rules; follow Texwipe instructions for controlled crushing of the inner ampule.
  3. Apply: Use the wetted polyester head only at the defined contact point and with approved movement/pressure.
  4. Inspect: Evaluate residues, streaking or remaining contamination against process-specific criteria instead of assuming a single pass is sufficient.
  5. Change out: Do not continue with a visibly loaded or damaged tip; dispose of the spent swab under site instructions for alcohol and glass-containing waste.
  6. Record: In controlled programs, identify the product and lot used and any exceptions or abnormal conditions as the applicable SOP requires.

Meaningful technical FAQs
  • When is TX726 a better choice than a dry swab with separately dispensed IPA? When the work point benefits from an integrated, specified 91% IPA liquid reservoir and individual single-swab presentation. If the process requires another liquid or adjustable dosing, use a validated separate-solvent procedure instead.
  • Which dimensions matter when qualifying a recessed feature? Compare the 8.3 mm head width/thickness and 10 mm head length with the opening and intended cleaning contact. The 47.6 mm overall length also limits reach. Confirm tool access in the actual fixture rather than relying only on the product name.
  • What evidence supports a residue-sensitive qualification? The current TX726 TDS identifies construction and solvent but does not publish TX726-specific NVR or ionic results. Request the appropriate exact-SKU manufacturer evidence and establish a facility test method/acceptance criterion before claiming a numerical cleanliness limit.
  • How should an optical-assembly or ionizer procedure be qualified? Texwipe identifies these applications, but the equipment manufacturer and site must approve the solvent, equipment state, contact technique, and post-clean inspection. The swab listing alone is not evidence of compatibility with every coating or ionizer design.

Authoritative manufacturer references

If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. For qualification, request current exact-SKU technical documentation and any required lot-specific records before establishing acceptance criteria. Content reviewed and revised: November 18, 2026. This is the preparation date, not the live publication date. © 2026 SOSCleanroom. All rights reserved.