Skip to main content

Texwipe TX1048 TechniSat 8" x 5" Cleanroom Gowning Room Wipe Pre-Wetted 6% IPA (Case Qty.)

$362.59
SKU: TX1048 CASE Stock Item
(No reviews yet)
Availability:
Stock Item
Shipping:
Calculated at Checkout
International Shipping:
Restricted to U.S. destinations only
Type:
Pre-Wet Wiper
Family:
TechniSat
Material:
Cellulose/Polyester
Wiper Size:
8" x 5"
Wiper Edge:
Cut Edge
ISO Class:
ISO 5 (Class 100) - ISO 8 (Class 100,000)
Country of Origin:
Made in USA

Texwipe TX1048 TechniSat 8" x 5" 6% IPA Pre-Wetted Gowning-Room Wipers

Texwipe TX1048 TechniSat® is a non-sterile, pre-wetted cellulose/polyester cleanroom wiper for gowning-room and controlled-area cleaning. The 8" x 5" wipe uses a 45% polyester / 55% cellulose nonwoven substrate with a cut edge and is pre-wetted with 0.2 µm filtered 6% isopropyl alcohol (IPA) / 94% deionized water. Its refill-and-flip-top-tub system provides a controlled dispensing option for cleaning gloves, objects entering the cleanroom, surfaces and equipment.

Before you order: One manufacturer case contains 12 refill packs of 210 wipers (2,520 wipers total) plus one flip-top tub. The case does not contain 12 separate tubs. Choose the exact SKU and case quantity that match your dispensing program.

Specifications:
  • Manufacturer part number: Texwipe TX1048; SOSCleanroom store selection: case configuration
  • Family / presentation: TechniSat® pre-wetted, non-sterile cleanroom wiper
  • Size: 8" x 5" nominal (20 cm x 13 cm)
  • Substrate: 45% polyester / 55% cellulose nonwoven
  • Edge: Cut edge
  • Solution: 6% IPA / 94% DI water, 0.2 µm filtered
  • Case contents: 210 wipes/refill pack; 12 refill packs/case; one flip-top tub/case; 2,520 wipes/case
  • Manufacturer cleanroom positioning: ISO Class 5–8 (Class 100–100,000), EU Grade B–D
  • Published shelf life: Three years from manufacture for non-sterile pre-wetted TechniSat products; verify receipt dates and applicable lot information
Where TX1048 Fits in Controlled-Area Cleaning

In gowning rooms and entry areas, cleaning practices must be repeatable across shifts and personnel. Texwipe positions TX1048 for cleaning gloves, items entering the cleanroom, production equipment, and other surfaces. A pre-wetted format removes the step of manually dispensing a separate cleaning solution onto each dry wipe; the flip-top dispenser helps protect remaining wipes from solvent evaporation when closed after use.

The manufacturer lists TX1048 for ISO Class 5–8 environments. This is product selection guidance, not certification that a specific room, cleaning method, or user process meets ISO 14644 requirements. Facility procedures determine where the material may be introduced, how it should be used, and when wipes must be changed.

Selection distinction: TX1048 contains 6% IPA, not the 70% IPA of other TechniSat variants. Select the concentration required by your approved method. No product-specific disinfectant contact time or microbial kill claim is established by the cited TX1048 documentation.

About the Manufacturer:

Texwipe, an ITW company, publishes part-number-controlled descriptions and a TechniCloth/TechniSat technical datasheet covering nonwoven composition, packaging, typical physical measurements, contamination-related testing, and lot coding. The exact TX1048 manufacturer listing specifies the 6% IPA variant and its 12-refill plus single-tub case format.

The separate safety data sheet explicitly includes TX1048 in the product-code list for 6% IPA pre-wetted wipers. Both technical qualification and EHS review should use the latest applicable manufacturer documentation and the facility's approved procedures.

TX1048 Features:
  • Defined pre-wet: 0.2 µm filtered 6% IPA / 94% DI water formulation
  • Nonwoven construction: Cellulose/polyester substrate balances liquid uptake and handling strength
  • Controlled dispensing: Flip-top tub supplied with 12 individual refill packs
  • Cleanroom manufacturing: Cut-edge nonwoven manufactured for controlled-area cleaning
  • Documented technical program: Manufacturer technical data, lot coding, and SKU-specific SDS applicability
TX1048 Benefits:
  • Repeatable dispensing: The pre-wetted format avoids a separate point-of-use mixing and saturation step during standard wipe-downs
  • Practical entry-point use: Compact 8" x 5" format for gloves, high-touch items and smaller work surfaces
  • Refill control: A reclosable tub supports wipe storage between uses when operators promptly close the lid
  • Technical traceability: Published material and test information helps purchasing and quality teams compare a specified part with alternatives
  • Defined solvent choice: The 6% formulation can be specified separately from stronger IPA concentrations when the application requires that particular chemistry
Common Applications:
  • Wiping gloves during gowning or entry activities as permitted by site procedures
  • Cleaning notebooks, phones, clipboards and other approved items entering controlled areas
  • Wiping touch points, equipment exteriors, tools and work surfaces
  • Applying and removing cleaning solutions or collecting small liquid spills as appropriate to the surface and process
  • General-purpose cleanroom wiping in manufacturer-positioned ISO Class 5–8 settings
Best-Practice Use:
  • Check the case configuration: Stock and stage the refill packs without counting the single included tub as a separate tub for every refill.
  • Protect the wipes: Introduce the dispenser and refills according to facility packaging and material-transfer controls; do not contaminate the dispensing opening.
  • Close after dispensing: Return the flip-top lid to its closed position to help limit evaporation during storage and use.
  • Use clean faces: Apply the facility-approved wiping pattern and change wipes before a loaded face redeposits residues.
  • Follow the SDS: Keep the pre-wetted product away from heat, sparks and open flames; use required personal protective equipment and follow local storage and disposal rules.
Selection Notes (TX1048 vs. Other Formats)
  • TX1048 vs. 70% IPA TechniSat: Different published IPA concentrations; do not substitute one for another where the validated cleaning procedure specifies the other.
  • Refill tub vs. reclosable bags: Choose TX1048 when one tub with a stock of 210-count refill packs fits the station workflow; manufacturer lists other TechniSat SKUs in individual reclosable-bag formats.
  • Pre-wetted vs. dry nonwoven: TX1048 supplies the manufacturer-prepared solution; dry TechniCloth variants allow site-specific fluid application.
  • Critical surfaces: Compare published particle, fiber, extractable and ionic typical analyses against your process requirements; do not assume the product is suitable for every surface or sterilization method.
Manufacturer Documentation:

Notes: The Technical Vault tab contains manufacturer-typical particle, fiber, sorption, residue, ion and testing information, plus the SDS precautions important to selecting and using TX1048. For application questions or current lot documentation, contact Sales@SOSsupply.com or (214) 340-8574.

SOSCleanroom can help confirm the exact order configuration and connect your team with the applicable Texwipe product documentation before a new material is qualified for a controlled cleaning program.

Content reviewed and revised: November 18, 2026. This is the draft content review date, not the live publication date.

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
TX1048 TechniSat® 6% IPA / 94% DIW 45/55 Nonwoven Gowning-Room Wiping Lot Documentation

Texwipe TX1048 TechniSat®: 6% IPA control in a tub-and-refill system

TX1048 is a non-sterile 8" x 5" pre-wetted wiper made from 45% polyester / 55% cellulose nonwoven material with a cut edge. The manufacturer identifies 6% IPA / 94% deionized water passed through a 0.2 µm filter as its pre-wet solution. The product is intended for general cleaning and wiping, including entry-point items, gloves, equipment and work surfaces. The supplied case contains 12 refill packs and one tub, making the dispenser architecture an important ordering and operational distinction.

Operations takeaway: TX1048 standardizes the supplied wiping solution and the dispenser format. Your facility still determines acceptable surfaces, wiping procedure, change-out rules, material introduction and whether 6% IPA is the appropriate chemistry.


Cleanroom context: product positioning versus process qualification

Texwipe positions TX1048 within ISO Class 5–8 and EU Grade B–D cleaning environments. The classification describes environments in which the product is marketed for use; it does not certify the cleanliness of a room or demonstrate performance in a specific facility process. Qualification depends on actual surfaces, cleanliness limits, personnel handling, approved chemistry and documented cleaning methods. The manufacturer also positions the TechniSat family with USP <797> and <800> wiper requirements; facility compliance must be determined against the applicable current standards and site procedures.

Selection control: The 6% IPA concentration is not interchangeable with a separately specified 70% IPA process; no TX1048-specific disinfectant kill efficacy or contact time is established by the cited documentation.


Specifications (procurement and receiving controls)
  • Manufacturer SKU: TX1048, TechniSat®, pre-wetted nonwoven cleanroom wiper; non-sterile
  • Nominal dimensions: 8" x 5" (20 cm x 13 cm)
  • Material: 45% polyester / 55% cellulose nonwoven; cut edge
  • Solution: 0.2 µm filtered 6% IPA / 94% DI water
  • Unit hierarchy: 210 wipes per refill pack; 12 refill packs + one flip-top tub per manufacturer case; 2,520 wipes/case
  • Manufacturer use positioning: ISO Class 5–8; EU Grade B–D
  • Shelf life: Three years from date of manufacture for non-sterile pre-wetted TechniSat (TX8488 has a separate shorter period)
  • Quality documentation: Texwipe describes individually lot-coded material and publishes technical testing methods

Receiving note: Inspect each pack for correct part number, quantity, condition, and lot/date identification, and keep the manufacturer documentation needed by your quality system.


Performance characteristics (manufacturer-published typical analyses)

The values below come from Texwipe's TechniCloth / TechniSat family datasheet, US-TDS-003 Rev.4/23. They are typical analyses for the specified nonwoven platform, not a certificate for a delivered TX1048 lot or proof of finished pre-wet formulation performance in a particular process.

  • Basis weight: 69 g/m2
  • Sorptive capacity: 360 mL/m2
  • Sorptive rate: <0.3 seconds
  • Liquid-borne particles (LPC ≥0.5 µm): 72 x 106 particles/m2
  • Fibers >100 µm: 55,000 fibers/m2
  • Nonvolatile residue (IPA extractant): 0.01 g/m2
  • Nonvolatile residue (DI-water extractant): 0.03 g/m2
  • Nonvolatile residue (ethanol extractant): 0.01 g/m2
  • Ions (typical): sodium 12 ppm; potassium 1 ppm; chloride 10 ppm

Interpretation: Compare the units, extraction media, particle/fiber size cutoffs and test methods against your defined receiving criteria. Do not present these typical results as guaranteed specifications or lot acceptance limits.


Understanding the methods and their limits
  • Particle analysis: LPC at ≥0.5 µm; manufacturer cites IEST-RP-CC004.3 and internal TM22.
  • Fiber counting: Fibers >100 µm; references ASTM E2090-12(2020) and Texwipe TM22.
  • Nonvolatile residue: Values depend on IPA, DI-water, or ethanol extractant; manufacturer references IEST-RP-CC004.3 and TM1.
  • Ionic content: Sodium, potassium and chloride values expressed in ppm; method reference TM18.
  • Sorption and basis weight: Capacity, rate and weight are substrate physical properties with method reference TM20.
  • Documentation: Texwipe states its proprietary TM procedures are available on request; require current methods and lot-specific records when setting formal acceptance criteria.

Qualification principle: Use the laboratory method and product-specific lot documents appropriate to the actual surface and contamination limit; test values from other Texwipe wiper families cannot be substituted.


Material construction, sorption and controlled wetness

The cellulose fraction provides an absorbent nonwoven component, while polyester contributes material strength during wiping. Texwipe positions TechniCloth/TechniSat for spill pickup, solution application and general cleaning. The cut-edge, nonwoven architecture should be selected with the particle and fiber characteristics in mind; applications requiring especially stringent edge control may use another construction after qualification.

A nominal sorptive capacity of 360 mL/m2 expresses typical laboratory uptake per unit wipe area under the manufacturer's method. It is not a guaranteed usable spill volume for an 8" x 5" saturated wipe. TX1048 arrives pre-wetted, so real pickup, liquid transfer and residue outcomes depend on solution loading, contact pressure, surface and cleaning method.

Practical selection: For a procedure requiring a defined wetting chemistry, verify the exact IPA concentration and wipe construction together, not just the name TechniSat.


Safety: 6% IPA pre-wetted wipers still require ignition controls

The Texwipe U.S./Canada safety data sheet explicitly lists TX1048 among its applicable product codes for 6% IPA pre-wetted wipers. Section 2 classifies the material as Flammable Solid, Category 2 (H228) with the signal word Warning. It calls for keeping the product away from heat, hot surfaces, sparks, open flames and other ignition sources, and specifies protective gloves and eye/face protection. The SDS also provides handling, ventilation, storage and disposal guidance.

  • Read the current applicable SDS before bringing the product into a new process.
  • Maintain the original approved container and close the dispenser when not in use.
  • Apply site EHS requirements for ignition control, personal protective equipment and disposal.
  • Do not infer that a lower nominal IPA percentage means the product is unregulated or nonflammable.

Shipping reminder: SDS hazard classification and carrier-specific transportation requirements are distinct matters. Verify the applicable checkout, quantity and shipping restrictions rather than assuming a fixed fee or classification.


Dispenser, refill and material-transfer controls
  • Confirm case contents: 12 sealed 210-count refills and one flip-top tub are supplied with the manufacturer case.
  • Transfer appropriately: Follow the facility's procedures for removing or wiping outer packaging before entry into controlled areas.
  • Keep dispensing controlled: Close the flip-top after removal to help limit evaporation and contact contamination.
  • Avoid cross-contamination: Do not touch unused wiping faces to used gloves, work surfaces or dirty packaging.
  • Standardize work method: Define direction of travel, wipe face rotation, use area, solvent wetness and change-out triggers in the applicable SOP.
  • Review shelf life: Texwipe publishes three years from manufacture for this non-sterile pre-wet category; lot dates determine whether a given case remains within that period.

Selection boundaries and comparison points
  • 6% versus 70% IPA: These are distinct manufacturer pre-wet formulations. Neither should be substituted into a validated method without site review.
  • Tub/refill versus reclosable bag: TX1048 uses one tub with replenishment packs; other TechniSat models use slider bags or flexpacks for different station/consumption needs.
  • Non-sterile handling: TX1048 is supplied non-sterile; selecting it does not fulfill a sterile-presentation requirement.
  • Wiper performance: Verify measured release, extractables and sorption against actual facility limits instead of inferring universal cleanroom qualification from ISO positioning.
  • Autoclaving: The family datasheet identifies autoclave suitability for dry wipes only; it does not establish an autoclave process for this pre-wetted SKU.

Meaningful technical FAQs
  • How does 6% IPA affect the decision between TX1048 and higher-concentration TechniSat? The manufacturer identifies different pre-wet ratios. Use the concentration and cleaning method specified in the facility SOP; this datasheet is not evidence of a TX1048 disinfectant contact time or antimicrobial kill claim.
  • Which TX1048 figures should quality engineers compare with their acceptance criteria? Consider LPC (≥0.5 µm), released fibers (>100 µm), solvent-specific NVR and ions, with their units and manufacturer methods. These are published typical analyses, not certified results for every lot.
  • What is the key purchasing difference between a refill pack and the case? A refill pack contains 210 wipes; the case contains 12 such packs plus a single tub. Do not treat the case as 12 tub dispensers.
  • What evidence should be requested before introducing TX1048 into a controlled process? Check the current exact-SKU page, technical datasheet, applicable 6% IPA SDS, lot identification and any site-required certificate or test report. Confirm 6% IPA and the dispenser format match the approved method.
  • How should a team interpret the three-year shelf-life statement? It is measured from manufacture for non-sterile pre-wetted TechniSat materials, not from delivery or from the date this webpage was reviewed. Compare the actual lot/manufacture date to the written receiving policy.

Why obtain TX1048 through SOSCleanroom
  • SKU matching: Use the TX1048 manufacturer part number with the correct 12-refill/one-tub case option.
  • Documentation support: Request the current Texwipe TDS, SDS and relevant lot traceability information for qualification and receiving.
  • Application support: Contact SOSCleanroom for help reconciling the 6% formulation, dispensing configuration and facility SOP requirements before placing a recurring order.

Manufacturer documentation (authoritative references)

Questions about TX1048 or qualification documents? Email Sales@SOSsupply.com or call (214) 340-8574. Manufacturer-published values are typical analyses, not lot-specific guarantees or proof of facility compliance. Content reviewed and revised: November 18, 2026. Draft review date only; not the live publication date. © 2026 SOSCleanroom. All rights reserved.