Skip to main content

Texwipe TX1041 TechniSat 9" x 11" Cellulose/Polyester Cleanroom Wiper Pre-Wet 70% IPA (Case Qty.)

$463.45
SKU: TX1041 CASE Stock Item
(No reviews yet)
Availability:
Stock Item
Shipping:
Calculated at Checkout
Type:
Pre-Wet Wiper
Family:
TechniSat
Material:
Cellulose/Polyester
Wiper Size:
9" x 11"
Wiper Edge:
Cut Edge
ISO Class:
ISO 5 (Class 100)
ISO Class:
ISO 6 (Class 1,000)
ISO Class:
ISO 7 (Class 10,000)
ISO Class:
ISO 8 (Class 100,000)

Texwipe TX1041 TechniSat 9" x 11" Pre-Wetted 70% IPA Cellulose/Polyester Cleanroom Wiper

Texwipe TX1041 TechniSat® is a non-sterile, pre-wetted 9" x 11" cleanroom wiper built from a hydroentangled 55% cellulose / 45% polyester nonwoven substrate. Its cut-edge fabric is supplied with 0.2 µm-filtered, USP-grade 70% isopropyl alcohol (IPA) / 30% deionized water (DIW). The combination of absorbent cellulose, reinforcing polyester, controlled pre-wetting and a reclosable slider bag is designed to support routine wipe-downs without each operator having to prepare and dispense a separate solvent mixture.

Ordering note: TX1041 contains 70 wipes per reclosable bag and 12 bags per case (840 wipes total). The SOSCleanroom listing is a case-quantity offering; manufacturer part number is TX1041.

Specifications:
  • Manufacturer / product: ITW Texwipe TechniSat® TX1041; pre-wetted, non-sterile nonwoven wiper
  • Nominal dimensions: 9" x 11" (23 x 28 cm)
  • Material: 55% cellulose / 45% polyester; hydroentangled nonwoven
  • Edge construction: Cut edge
  • Pre-wet: USP-grade 70% IPA / 30% DIW; manufacturer states the solution is filtered to 0.2 µm
  • Package: 70 wipes per reclosable slider bag; 12 bags per case; 840 wipes per case
  • Manufacturer cleanroom positioning: ISO Class 5–8 (Class 100–100,000), EU Grade B–D; suitability is process-specific
  • Shelf life: Manufacturer lists three years from manufacture for non-sterile pre-wetted TechniSat products; check the received package and lot details
  • Store selling SKU: TX1041 CASE; manufacturer base part number: TX1041
Where TX1041 Fits in ISO Cleanrooms (and Why)

The manufacturer positions TX1041 for cleaning surfaces, equipment and parts and for controlled application or removal of process solutions. The cellulose/polyester blend combines liquid uptake with wet strength, while a pre-wetted presentation helps standardize solvent delivery. In ISO-class operations, the selected wipe, solvent amount, surface and technique must work together in the site-approved procedure.

Program-fit note: The ISO Class 5–8 statement is Texwipe product-use positioning. It does not certify that TX1041 alone qualifies any room, disinfects a surface, or meets a facility-specific residue acceptance limit.

For cleaning near sensitive assemblies, qualify the wiper against the actual residue, particulate and surface requirements. Where sterilization or a validated antimicrobial contact time is required, follow the specific approved material and chemical procedure rather than interpreting a 70% IPA pre-wet label as a sterility or disinfection-efficacy claim.

About the Manufacturer:

Texwipe manufactures cleanroom consumables and publishes wiper-family technical data on releasable particles and fibers, nonvolatile residues, ions, sorption and material construction. TX1041 belongs to the TechniSat pre-wetted portion of its TechniCloth family. Its exact-SKU page identifies the solution grade, filtration, reclosable packaging and case configuration.

The manufacturer also provides a Safety Data Sheet specifically listing TX1041 among its 60%–70% IPA pre-wetted wipes. This supports safety reviews and receiving controls separately from the typical-performance measurements in the TechniCloth Technical Data Sheet.

TX1041 Features:
  • 45% polyester / 55% cellulose hydroentangled nonwoven construction with a cut edge
  • Pre-wetted with USP-grade 70% IPA / 30% DIW, filtered to 0.2 µm
  • Reclosable slider bag intended to reduce evaporation and help maintain wetness during dispensing
  • 70 wipes per bag and 12 bags per case; manufacturer identifies individual lot coding
  • Manufacturer-stated ISO Class 5–8 cleanroom application range
TX1041 Benefits:
  • Less wetting variability: A pre-wetted format reduces dependence on manual mixing and bottle-to-wiper application for every cleaning pass.
  • Useful wet strength: The hydroentangled cellulose/polyester substrate is designed for general wiping and liquid pickup while retaining handling strength.
  • Controlled dispensing: Reclosing the slider bag helps limit solvent evaporation between pulls and supports a repeatable wipe-down routine.
  • Documented selection: Manufacturer literature supplies typical substrate testing and an SDS, allowing Quality and EHS to assess distinct cleanliness and chemical hazards.
  • Clear procurement configuration: 840 wipes per case avoids confusing TX1041 with 50-wipe flexpack versions of TechniSat.
Common Applications:
  • Wiping and cleaning production or laboratory equipment exteriors, carts, work surfaces and parts as authorized by the local cleaning procedure
  • Routine residue pickup and solution application/removal where the prescribed chemistry is 70% IPA / 30% DIW
  • General controlled-environment cleaning, including items entering the room where the facility transfer procedure permits this wiper
  • Small spill pickup and wipe-down operations appropriate for the pre-wetted sheet format
  • Controlled wiping in laboratory, medical-device and other cleanroom programs where the specific material and chemical requirements have been qualified
Best-Practice Use:
  • Check the pack: Confirm TX1041, correct 70% IPA presentation, legible lot/date, intact packaging and suitability before introduction.
  • Handle IPA safely: Follow the SDS, keep away from ignition sources and use appropriate ventilation and PPE determined by the site assessment.
  • Reseal after dispensing: Close the slider bag promptly to limit evaporation and wetness change.
  • Control the wiping path: Use the SOP-defined wipe pattern, clean-face rotation and discard point; avoid carrying a loaded wipe back across cleaned areas.
  • Do not improvise solution changes: Do not add unapproved liquid or mix chemistries in the pack. Select a different validated product when the process calls for a different concentration.
  • Dispose under site rules: Used IPA-wetted wiping materials require handling and disposal compatible with the SDS and local procedures.
Selection Notes (TX1041 vs. Other Options)
  • TX1041 versus TX1065: Both are 9" x 11" pre-wetted TechniSat wipers using USP-grade 70% IPA / 30% DIW; TX1041 supplies 70 wipes in a reclosable slider bag, whereas TX1065 supplies 50 wipes per flexpack. Choose based on dispensing and inventory requirements.
  • TX1041 versus TX1067: TX1067 is a narrower 7" x 11" format with 200 wipes per reclosable bag. A smaller sheet width or higher dispensing count may be relevant, subject to the same chemistry and process qualification.
  • Pre-wetted versus dry TechniCloth: Choose TX1041 when the SOP calls for manufacturer-prepared 70% IPA wetting. Use the applicable dry version when the process requires no solvent or approved point-of-use wetting.
  • Critical-control applications: Compare material cleanliness and test data with your facility limits; a manufacturer ISO range is not a substitute for substrate or method validation.
Link to Texwipe Technical Datasheet: Click Here
Other Similar Products Available From SOSCleanroom.com

TechniSat Pre-Wetted Wipers

  • TX1065: 9" x 11" 70% IPA, 50 wipes per flexpack
  • TX1067: 7" x 11" 70% IPA, 200 wipes per reclosable bag
  • TX1045: 6" x 8" 70% IPA, 100 wipes per reclosable bag
  • TX1048: 8" x 5" 6% IPA gowning-room wipe configuration (different chemistry)

Technical Documentation

Recommended Glove Pairings for TX1041 TechniSat

Glove selection for IPA handling should follow the current SDS and facility chemical-risk assessment. When ISO cleanliness matters, select cleanroom-processed gloves appropriate to the zone and verify the glove manufacturer's IPA breakthrough and exposure guidance rather than assuming all nitrile or latex grades offer equivalent protection.

Selection principle: Match glove cleanliness to the controlled environment and glove chemistry resistance to the actual IPA exposure, then replace gloves under your approved contamination-control procedure.

Notes: Need typical particle, residue, ion and sorption measurements, SDS handling, or detailed qualification guidance? Review the matching SOSCleanroom Technical Vault and the current Texwipe documentation before defining acceptance criteria.

For product and documentation support, email Sales@SOSsupply.com or call (214) 340-8574.

Content reviewed and revised: November 17, 2026 (content prepared for review; not a live publication date)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
TX1041 / TechniSatISO Class 5–870% USP-Grade IPA / 30% DIW55% Cellulose / 45% PolyesterNon-Sterile / Pre-Wetted

Texwipe TX1041 TechniSat: what is controlled and what must be qualified9" x 11" pre-wetted cellulose/polyester wiper for controlled IPA wipe-downs

TX1041 combines a hydroentangled 55% cellulose / 45% polyester nonwoven with a factory-prepared solution of USP-grade 70% IPA / 30% DIW, filtered to 0.2 µm. Texwipe identifies the exact TX1041 format as a 70-wipe reclosable bag, with 12 bags per case. In process qualification, control the SKU, pre-wet solution, bag configuration, applicable cleanliness data, safe handling and wipe technique as a set rather than treating the wiper as interchangeable with any 70% IPA product.

Operations takeaway: TX1041 reduces the need for point-of-use solvent application, but the reclosable pack must be kept sealed between uses. A consistent wetting format does not independently demonstrate disinfectant efficacy, surface compatibility or a qualified cleaning process.


ISO-first context: cleaning is an operational control

Texwipe positions TechniSat TX1041 for ISO Class 5–8 controlled environments and EU Grade B–D. These are product-application ranges; room classification is not a certification of any wipe. A site-approved cleaning program must define surface coverage, solvent exposure, material transfer, monitoring and the acceptable particulate and residue outcomes.

Selection boundary: Texwipe states its TechniCloth/TechniSat products meet USP <797> and <800> wiper requirements. This manufacturer statement is not an assurance that an individual compounding facility, cleaning method or disinfection procedure is compliant.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer part number: Texwipe TX1041; TechniSat® non-sterile pre-wetted wiper
  • Nominal size: 9" x 11" (23 x 28 cm)
  • Construction: Hydroentangled nonwoven, 55% cellulose / 45% polyester
  • Edge: Cut edge
  • Pre-wet solution: 70% isopropyl alcohol, USP grade / 30% deionized water; manufacturer states 0.2 µm filtration
  • Packaging: 70 wipes per reclosable slider bag; 12 bags per case; 840 wipes total
  • SOS listing configuration: TX1041 CASE; do not substitute the TX1065 flexpack format without approval
  • Manufacturer positioning: ISO Class 5–8; EU Grade B–D
  • Manufacturer shelf life: Non-sterile pre-wetted products: 3 years from manufacture; validate actual received lot/date
  • Traceability: Texwipe lists individual lot coding for this product family

Receiving control: Compare the base manufacturer SKU, case label, bag count, alcohol presentation, lot number and applicable SDS before stocking.


Performance characteristics (manufacturer-published typical analyses)

The following values appear in Texwipe's TechniCloth / TechniSat family Technical Data Sheet (US-TDS-003 Rev. 4/23). The document explicitly includes TX1041 in its product table. These are typical family analytical values, not contractual lot specifications or proof of the final pre-wet solution's individual lot results.

  • Basis weight: 69 g/m2 (TM20)
  • Sorptive capacity: 360 mL/m2 (TM20)
  • Sorptive rate: <0.3 seconds (TM20)
  • Particles, LPC ≥0.5 µm: 72 x 106 particles/m2 (TM22)
  • Fibers >100 µm: 55,000 fibers/m2 (TM22)
  • NVR, IPA extractant: 0.01 g/m2 (TM1)
  • NVR, DI-water extractant: 0.03 g/m2 (TM1)
  • NVR, ethanol extractant: 0.01 g/m2 (TM1)
  • Sodium: 12 ppm (TM18)
  • Potassium: 1 ppm (TM18)
  • Chloride: 10 ppm (TM18)

How to interpret: Sorptive capacity measures liquid uptake per area under the published method, not the volume of IPA supplied in each TX1041 wipe. Particle, fiber, NVR and ionic values describe manufacturer-typical analytical results; qualification against a facility limit requires documented methods and acceptance criteria.


Test methods, traceability and specification status
  • TM22: Texwipe particle and fiber method cited alongside IEST-RP-CC004.3 and ASTM E2090-12(2020) references in the family TDS
  • TM1: Texwipe method for nonvolatile-residue measurements with specified extractants
  • TM18: Texwipe method for ionic contamination results
  • TM20: Texwipe method for sorption and basis-weight analyses
  • Method documents: Manufacturer states its internal test methods are available upon request
  • Evidence boundary: Texwipe states TDS data are typical analyses, not product specifications; a lot-specific certificate must not be presumed from this family table
  • Recordkeeping: Retain the correct part number, manufacturer lot identity, TDS/SDS revision and site acceptance record for controlled programs

Why the substrate and pre-wet presentation matter

Cellulose/polyester hydroentangled nonwoven: The manufacturer identifies cellulose as the sorptive component and polyester as the reinforcing component in blended nonwovens. Hydroentanglement supplies mechanical consolidation without converting the product into a polyester knit or a sealed-edge wiper. The cut edge remains a selection consideration for particle- and fiber-critical processes.

Pre-wet chemistry: USP-grade IPA / DIW is prepared by Texwipe and filtered to 0.2 µm. Filtering the solution does not certify that a wiped surface becomes sterile, nor does the solution composition alone define an antimicrobial contact time. The user must validate any required chemistry, coverage, dwell or compatibility steps under the applicable SOP.

Dispensing discipline: Reclosable slider bags are intended to reduce evaporation. Close between pulls, avoid adding outside liquids to the bag and discontinue use under the facility protocol if wetness or package integrity becomes unacceptable.


Safety and storage: use the exact applicable SDS
  • SDS applicability: Texwipe's "Wipers pre-wetted with 60%–70% IPA" SDS explicitly lists TX1041 (May 31, 2023 file)
  • Hazard classification: Flammable solid Category 2 (H228); eye irritation Category 2A (H319); specific target organ toxicity, single exposure, narcotic effects Category 3 (H336)
  • Ignition control: Keep away from heat, sparks, flames and smoking; follow ventilation and ignition-source controls from the SDS
  • Eye, glove and respiratory protection: Choose PPE through the facility exposure assessment and current SDS; do not assume universal glove resistance
  • Storage: Keep original containers tightly closed in a cool, dry, well-ventilated area away from incompatible substances, sunlight and ignition sources
  • Expiration: Texwipe lists 3-year shelf life from manufacture for non-sterile pre-wets. Check the labeled lot and receiving program rather than calculating an unstated expiration date

Critical distinction: The SDS calls the saturated wipe a flammable solid. Do not replace this with an unsupported consumer-style claim that the product is nonhazardous merely because no free liquid is present.


Best-practice use (repeatability and contamination control)
  1. Verify identity and condition: Check lot and package integrity, chemical designation and expiry status before bringing a pack into the clean area.
  2. Introduce under the facility method: Perform required external package wipe-down and controlled transfer; do not bring shipping cartons into classified areas without authorization.
  3. Use a clean wiping face: Fold and use controlled strokes; refold or replace before returning to a cleaned area with a loaded surface.
  4. Maintain the wetness design: Use TX1041 as supplied; do not pool additional IPA in the bag or use visibly compromised material.
  5. Replace at the SOP trigger: Discard after the defined use area, contamination loading or solvent condition; do not keep reusing a single wipe without a qualified change-out rule.
  6. Reseal, store and dispose appropriately: Follow the SDS and approved hazardous waste/housekeeping arrangements.

Method standardization: Document the wipe path, fold pattern, surface coverage, acceptable wetness and discard point. A validated disinfectant process additionally needs the specific chemistry and demonstrated contact conditions.


Selection limitations and when another product is appropriate
  • Sterility-critical processes: TX1041 is non-sterile; use the approved sterile presentation and supporting lot evidence where sterile introduction is a requirement.
  • Dry procedures: A pre-wetted 70% IPA format is not a substitute for a dry wiper where moisture or IPA exposure is prohibited.
  • Autoclaving: The TechniCloth family TDS calls dry wipers only autoclave safe; do not infer that an IPA-pre-wetted TX1041 bag is autoclave compatible.
  • Highly sensitive residues or optics: Compare actual NVR/ionic/particle limits and validate the wipe/solution/surface combination; typical data are not lot acceptance limits.
  • Disinfection claims: Neither an IPA concentration statement nor cleanroom-use positioning substitutes for organism-specific efficacy or dwell-time validation.
  • Different dispensing needs: TX1065 is 50 per flexpack at the same nominal sheet size; TX1067 is 200 per slider bag in a narrower 7" x 11" sheet.

Technical FAQs that answer real qualification decisions
  • How should Quality use the 360 mL/m2 sorptive capacity when choosing a wipe? Treat it as a manufacturer-typical substrate-family method result, not the IPA fill amount or guaranteed liquid delivered per sheet. Determine suitability through process-specific surface, wiping and residual-liquid checks.
  • What should a receiving SOP record for a pre-wetted wiper? Record manufacturer and selling SKU, lot, pack count, solvent type, date/condition, the applicable TDS/SDS revisions and any site-required acceptance evidence.
  • What changes when selecting TX1041 rather than TX1065? Both are 9" x 11" TechniSat 70% IPA products, but TX1041 is 70 per reclosable bag and TX1065 is 50 per flexpack. Qualification should include the dispensing workflow and whether each pack can remain properly closed during use.
  • What must be established before calling this a validated disinfecting step? The approved chemistry, surface compatibility, application method, coverage, required contact time and evidence for the claimed microbial performance. The TX1041 materials describe a pre-wetted cleaning wiper, not a stand-alone validated kill claim.
  • What if a facility requires lower fiber or ionic release? Compare the published typical performance data with the facility's tested limits, use the appropriate manufacturer test documentation and evaluate an alternative wiper construction if TX1041 does not qualify.

Manufacturer documentation (authoritative references)

Why buy ITW Texwipe TechniSat from SOSCleanroom
  • Correct configuration: Match the 70-per-bag TX1041 format to the controlled purchasing specification rather than accepting an unreviewed flexpack substitution.
  • Documentation support: Use the manufacturer's exact-SKU page, family TDS and applicable SDS to maintain a defensible qualification file.
  • Program continuity: Purchasing, receiving and site SOPs should reference the same SKU and version-controlled documentation.

If you have questions about TX1041, email Sales@SOSsupply.com or call (214) 340-8574. Content reviewed and revised: November 17, 2026 (prepared for review; not confirmation of live publication). © 2026 SOSCleanroom. All rights reserved.