Skip to main content

Teknipure TM-MFP-516P-ST TekniMop Sterile Microfiber Knit Pocket Mop Cover, Integrated Pad, 5″x16″ (Refills) (Case Qty.)

$507.04
SKU: TM-MFP-516P-ST CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout
Type:
Dry Mop
Sterile:
Yes

Teknipure TM-MFP-516P-ST TekniMop Sterile Microfiber Knit Pocket Mop Cover, Integrated Pad, 5″x16″ (Refills) (Case Qty.) - SOSCleanroom Standard Specification

The Teknipure TM-MFP-516P-ST TekniMop™ Sterile Microfiber Knit Pocket Mop Cover is a dry, sterile cleanroom mop cover with an integrated absorbent pad designed for large-surface cleaning in pharmaceutical, biotech, and other critical environments. Its knit microfiber cleaning surface supports effective capture and retention of small particles and contaminants, while the integrated pad provides increased absorbency, liquid retention, and controlled solution release without requiring a separate mop pad.

Sterile microfiber cleaning with integrated absorbency: TM-MFP-516P-ST combines a 5" x 16" knit microfiber cleaning surface with a fully enclosed integrated pad and sterile gamma-irradiated presentation. Sterility is validated to a sterility assurance level (SAL) of 10-6, while the dry format allows facilities to select and control the cleaning or disinfecting chemistry required by their established procedure.

Specifications:
  • Part Number: TM-MFP-516P-ST
  • Product Type: Sterile microfiber knit pocket mop cover with integrated absorbent pad
  • Size: 5" x 16"
  • Material: Knit microfiber
  • Pad: Integrated absorbent pad
  • Attachment: Pocket-style
  • Format: Dry
  • Sterility: Sterile
  • Sterilization Method: Gamma irradiation
  • Sterility Assurance Level: SAL 10-6
  • Sterility Validation: Validated according to AAMI guidelines
  • Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
  • Packaging: 1 cover/bag, 5 bags/pack, 10 packs/case
  • Total Case Quantity: 50 covers/case
  • Compatible Hardware: Designed for TekniMop™ 5" x 16" frame systems; TM-PFM516HF is directly listed by Teknipure
Where TM-MFP-516P-ST Fits in Controlled Environments

TM-MFP-516P-ST is designed for sterile large-surface cleaning where facilities require a sterile mop cover while retaining control over the cleaning or disinfecting chemistry applied at the point of use. Its 5" x 16" format provides practical coverage for floors, walls, ceilings, large equipment surfaces, and other broad controlled-environment areas.

The knit microfiber cleaning surface supports capture and retention of small particles and contaminants, while the integrated absorbent pad provides additional liquid capacity and controlled solution release. Because the pad is built into the cover and enclosed on all sides, no separate pad component is required during system setup.

Typical program fit: Sterile cleanroom floor cleaning, wall cleaning, ceiling cleaning, large equipment and facility surfaces, disinfectant and sanitizer application, residue removal, spill control, and general cleaning of large controlled-environment areas.

TM-MFP-516P-ST is supplied sterile and dry. Final suitability should be evaluated according to the target surface, cleaning chemistry, contamination-control objective, required saturation level, sterile material-flow requirements, compatible hardware, validated cleaning procedure, and facility SOP.

About the Manufacturer:

Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, compounding pharmacies, laboratories, and other controlled environments.

Within the TekniMop™ microfiber mop-cover family, Teknipure offers dry, presaturated, sterile, and non-sterile configurations. Integrated-pad constructions combine the microfiber cleaning surface and absorbent layer into a single cover to simplify setup and support controlled liquid management during cleaning procedures.

TM-MFP-516P-ST Features:
  • High-density knit microfiber cleaning surface
  • 5" x 16" format for large-surface controlled-environment cleaning
  • Integrated absorbent pad for increased liquid capacity
  • Pad covered on all sides to eliminate particle generation from exposed pad material
  • Pocket-style construction for quick and easy cover changes
  • No separate mop pad required
  • Microfiber material captures and retains small particles and contaminants
  • Good absorbency and liquid retention for spill control and disinfectant application
  • Dry format allows facility-controlled chemistry selection and saturation
  • Compatible with IPA and common cleanroom disinfectants
  • Gamma irradiated for sterile cleaning applications
  • Sterility assurance level (SAL) of 10-6
  • Sterility validated according to AAMI guidelines
TM-MFP-516P-ST Benefits:
  • Sterility assurance: Gamma irradiation to an SAL of 10-6 supports cleaning programs requiring sterile consumables.
  • Effective contamination pickup: Knit microfiber construction provides high surface contact to support capture and retention of small particles and contaminants.
  • Integrated-pad convenience: The built-in absorbent pad eliminates the need to purchase, install, and manage a separate mop pad.
  • Increased fluid capacity: The integrated pad provides additional liquid-holding capacity for wet-cleaning, disinfectant-application, and spill-control procedures.
  • Flexible sterile chemistry selection: The dry format allows facilities to select the cleaning or disinfecting chemistry required by the validated sterile cleaning procedure.
  • Controlled saturation: Operators can establish the required wetness level rather than relying on a predetermined factory-presaturated amount.
  • Controlled solution release: The integrated pad supports consistent liquid retention and release during surface cleaning.
  • Large-area efficiency: The 5" x 16" footprint provides practical coverage for floors, walls, ceilings, equipment surfaces, and other broad areas.
  • Reduced component handling: Integrating the absorbent pad into the cover removes a separate assembly step and reduces the number of components handled in the cleaning workflow.
Common Applications:
  • Sterile cleanroom floor cleaning
  • Wall cleaning
  • Ceiling cleaning
  • Large equipment and facility surfaces
  • Application of disinfectants and sanitizers
  • Particle and residue removal
  • Controlled surface wetting
  • Spill control and liquid pickup
  • General cleaning of large sterile and controlled-environment areas
Best-Practice Use:
  • Maintain sterile handling: Introduce and handle the sterile cover according to the facility's material-transfer, aseptic handling, and contamination-control procedures.
  • Install securely: Fit the pocket-style cover fully onto compatible 5" x 16" mop hardware so the integrated absorbent pad remains evenly positioned beneath the microfiber cleaning surface.
  • Select the appropriate chemistry: Because TM-MFP-516P-ST is supplied dry, apply the cleaning or disinfecting solution according to the chemistry manufacturer's instructions and facility SOP.
  • Control saturation: Wet the microfiber surface and integrated pad sufficiently for the procedure without unnecessary oversaturation, dripping, or excessive solution deposition.
  • Use controlled cleaning patterns: Follow the unidirectional, overlapping, or other validated mopping pattern established by the facility for the surface being cleaned.
  • Work from cleaner to less-clean areas: Follow the facility's established contamination-control sequence and avoid moving collected contamination back into previously cleaned areas.
  • Observe required contact time: When applying disinfectants or sanitizers, maintain the required surface wetness and contact time specified by the chemistry manufacturer and facility procedure.
  • Change covers as required: Replace the cover according to surface area, contamination load, room transition, chemistry condition, or other changeout criteria established by the facility.
Selection Notes (TM-MFP-516P-ST vs. Other TekniMop™ Options)
  • TM-MFP-516P-ST: Choose this version when a sterile, dry 5" x 16" microfiber cover with an integrated absorbent pad is required and the facility needs direct control over cleaning chemistry and saturation.
  • TM-MFP-516P: Select the dry, non-sterile 5" x 16" microfiber version when sterile presentation is not required.
  • TM-MFP9G-516P: Select the non-sterile 9% IPA presaturated version when standardized ready-to-use IPA delivery is preferred.
  • TM-MFPK-516P: Select the dry, non-sterile integrated-pad microfiber version when sterile presentation is not required.
  • TM-MFPK9G-516P: Select the 9% IPA presaturated integrated-pad version when ready-to-use chemistry and increased liquid capacity are desired.
  • Sterile dry vs. presaturated: TM-MFP-516P-ST provides chemistry flexibility while maintaining sterile presentation; presaturated alternatives reduce point-of-use preparation when their supplied chemistry matches the validated procedure.
Compatible TekniMop™ Products

Directly Listed Compatible Mop System

  • TM-PFM516HF: 5" x 16" polyethylene frame with extendable aluminum handle
Building a TM-MFP-516P-ST TekniMop™ System

The TM-MFP-516P-ST is the sterile dry microfiber integrated-pad mop-cover component of a TekniMop™ large-surface cleaning system. Pair the cover with compatible 5" x 16" mop hardware and prepare it with the cleaning chemistry and saturation level required by the validated sterile cleaning procedure.

Directly listed configuration:
TM-MFP-516P-ST Sterile Microfiber Knit Mop Cover with Integrated Pad + TM-PFM516HF 5" x 16" Frame & Extendable Aluminum Handle System

The absorbent pad is already integrated into the mop cover, so no separate pad component is required. Select the cleaning chemistry and saturation level according to the applicable validated procedure and facility SOP.

Workflow note: TM-MFP-516P-ST is supplied sterile and dry. Sterile material transfer, package opening, solution application, cover changeout, surface wetting, use, and disposal should follow the facility's validated cleaning and contamination-control procedures.

Notes: Looking for application guidance or qualification context for the Teknipure TM-MFP-516P-ST TekniMop™ Sterile Microfiber Knit Pocket Mop Cover with Integrated Pad? Open the SOSCleanroom Technical Vault tab above for detailed sterile large-surface cleaning guidance, microfiber mop-cover selection, integrated-pad considerations, chemistry application, system configuration, cover changeout considerations, and compatibility information.

SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.

Product page updated: Oct. 28, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
Sterile Knit Microfiber 5" x 16" Integrated Absorbent Pad Pocket Attachment Dry Gamma Irradiated SAL 10-6 50 Covers/Case

Teknipure TekniMop™ TM-MFP-516P-ST: sterile dry microfiber cover with an integrated absorbent pad

The Teknipure TekniMop™ TM-MFP-516P-ST is a sterile, dry 5" x 16" microfiber knit pocket mop cover with an integrated absorbent pad. It combines a microfiber cleaning face, built-in liquid-holding capacity, individual packaging, and gamma-irradiated sterile presentation for controlled cleaning programs that require a sterile mop consumable while retaining facility control over cleaning chemistry.

Operations takeaway: This is the sterile version to select when the cleaning procedure requires a dry, individually packaged microfiber mop cover with built-in absorbency. Sterility, chemistry selection, and wetting remain separate process controls.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer: Teknipure
  • Part Number: TM-MFP-516P-ST
  • Product: TekniMop™ Sterile Microfiber Knit Pocket Mop Cover with Integrated Absorbent Pad
  • Nominal Size: 5" x 16" (13 cm x 41 cm)
  • Cleaning Material: Knit microfiber
  • Pad: Integrated absorbent pad
  • Attachment: Pocket-style
  • Supplied Condition: Dry
  • Sterility: Sterile
  • Sterilization: Gamma irradiated
  • Sterility Assurance Level: SAL 10-6
  • Sterility Validation: Manufacturer states validation according to AAMI guidelines
  • Cleanroom Environment: Manufacturer lists ISO Class 5–8
  • Packaging: 1 cover/bag, 5 bags/pack, 10 packs/case
  • Total Case Quantity: 50 covers/case
  • Compatible Hardware: TM-PFM516F and TM-PFM516HF
  • Published Sterile-Cover Shelf Life: 3 years from date of manufacture
  • Storage: Clean, dry environment at 59°F (15°C) to 85°F (30°C)

Exact-SKU control: Preserve the complete TM-MFP-516P-ST designation. The “-ST” suffix identifies a sterile configuration and should not be omitted from purchase orders, SOPs, inventory records, or qualification documents.


Sterility assurance: gamma irradiated to SAL 10-6

Teknipure states that TM-MFP-516P-ST is gamma irradiated to a sterility assurance level of 10-6 and validated for sterility according to AAMI guidelines.

  • Sterile supplied condition: Sterility is a manufacturer-controlled attribute of this exact SKU.
  • Gamma irradiation: Used by the manufacturer to sterilize the finished product.
  • SAL 10-6: Manufacturer-stated sterility assurance level.
  • Individual packaging: Supports controlled introduction of individual sterile covers into the cleaning workflow.

Sterility principle: Sterility is maintained by the complete packaging, handling, transfer, opening, installation, and use process. A sterile product can lose its sterile status through improper handling after package opening.


Sterile packaging architecture: individual bag → pack → case
  • Primary Package: 1 sterile cover per bag
  • Pack: 5 individually bagged covers
  • Case: 10 packs
  • Total: 50 covers/case

Material-transfer advantage: Individual packaging allows the facility to transfer only the units required for a task while keeping the remaining covers sealed. The facility should still define outer-pack removal, disinfection, transfer, opening, and presentation according to its SOP.


Integrated absorbent pad: built-in liquid capacity without a separate component

Integrated absorbent pad: Built into the cover to provide additional liquid-holding capacity and cushioned surface contact without requiring a separate pad.

  • Additional liquid capacity: Supports wet cleaning and solution application.
  • Cushioned contact: Provides compliant backing beneath the microfiber cleaning surface.
  • Fewer loose components: No separate absorbent pad must be installed.
  • Reduced assembly handling: Cleaning textile and absorbent backing are introduced as one consumable.
  • Unified changeout: The entire cover assembly is replaced together.

Pad covered on all sides: keeping the absorbent component internal

Teknipure states that the integrated pad is covered on all sides to reduce particle generation from exposed pad material.

  • External interface: The microfiber layer is the intended working surface.
  • Internal function: The absorbent pad provides liquid management and cushioning.
  • Inspection: Check the cover for tears, exposed internal material, or damaged pockets before use.
  • Damage response: Do not use a compromised cover in a sterile cleaning procedure.

Important: An enclosed pad reduces direct exposure of the absorbent material, but it does not justify claims of zero particle generation under every use condition.


Knit microfiber: direct particle and residue pickup

Teknipure describes the knit microfiber cleaning surface as capturing and retaining small particles and contaminants to support contamination-control cleaning.

  • High surface contact: Fine microfiber structure increases interaction with the target surface.
  • Particle pickup: Supports mechanical removal of particulate contamination.
  • Residue removal: Provides physical cleaning action against compatible residues.
  • Contaminant retention: Designed to retain removed material within the cleaning face.
  • Low-linting positioning: Suitable terminology for critical-environment contamination control.

Claim boundary: Microfiber pickup does not establish microbial kill. Sterility of the cover and antimicrobial efficacy of the cleaning chemistry are separate attributes.


Sterile + dry: separate sterility from chemistry selection

TM-MFP-516P-ST is supplied sterile but dry. The facility therefore controls the chemistry used during the cleaning procedure.

  • Sterility: Already established by the manufacturer for the packaged consumable.
  • Chemistry: Selected separately by the facility.
  • Concentration: Controlled according to the approved cleaning or disinfection procedure.
  • Solution loading: Defined by the facility.
  • Surface wetness: Determined according to the process objective and selected chemistry.

Critical distinction: Sterile does not mean presaturated. TM-MFP-516P-ST provides a sterile cleaning consumable while leaving solution selection and wetting under facility control.


Aseptic handling: protect sterility through transfer and installation
  1. Verify the package: Confirm part number, lot, expiration, and package integrity.
  2. Follow the material-transfer process: Remove or disinfect outer packaging according to the facility SOP.
  3. Protect the sterile bag: Avoid uncontrolled contact during movement into the cleaning area.
  4. Open using the approved technique: Present the cover without contaminating the cleaning face or interior surfaces.
  5. Install onto prepared hardware: The reusable frame and handle must meet the cleanliness or sterilization requirements defined by the facility.
  6. Protect the working face: Prevent contact with floors, carts, packaging exteriors, garments, or uncontrolled surfaces before use.

System sterility principle: A sterile mop cover does not make contaminated hardware sterile. The cover, frame, handle, chemistry, operator technique, and material-transfer method must all align with the facility’s aseptic procedure.


Chemical compatibility: IPA and common cleanroom disinfectants

Teknipure lists compatibility with IPA and common cleanroom disinfectants without shedding particulates or degrading under the intended use conditions described by the manufacturer.

  • IPA: Use where the facility procedure specifies an approved IPA solution.
  • Disinfectants and sanitizers: Follow the chemistry manufacturer’s concentration and contact requirements.
  • Sporicidal products: Confirm compatibility, safety requirements, and labeled application conditions.
  • Residue removal: Match chemistry and technique to the actual residue and target surface.

Efficacy boundary: Cover compatibility does not establish disinfectant efficacy. The selected chemistry and its approved application method control the antimicrobial step.


Documented hardware compatibility: TM-PFM516F / TM-PFM516HF

Teknipure’s current exact-SKU TDS row identifies TM-PFM516F and TM-PFM516HF as the compatible hardware for TM-MFP-516P-ST.

  • TM-PFM516F: 5" x 16" collapsible polyethylene mop frame.
  • TM-PFM516H: Extendable aluminum handle, 4–6 ft.
  • TM-PFM516HF: Complete polyethylene frame and extendable aluminum handle kit.

Compatibility rule: Use the exact current TDS compatibility listing for qualification. Do not automatically transfer TKM415 compatibility from adjacent 5" x 16" TekniMop™ covers.


Reusable hardware processing: sterile cover + non-autoclavable platform

Teknipure lists the TM-PFM516F polyethylene frame and TM-PFM516H aluminum handle as not autoclavable.

Procedure implication: Where sterile cleaning is required, the facility must establish an appropriate preparation and transfer method for the reusable hardware. Do not assume that the sterile cover alone creates a sterile assembled mop system.


Manufacturer-listed applications
  • Cleanroom floor cleaning
  • Wall cleaning
  • Ceiling cleaning
  • Application of disinfectants and sanitizers
  • Residue removal
  • Spill control
  • General cleaning of large areas

Application boundary: Sterile presentation does not establish suitability for every chemistry, contamination type, or surface. The complete cleaning process still requires qualification.


ISO Class 5–8 positioning: sterile status and room classification remain separate

Teknipure lists TM-MFP-516P-ST for ISO Class 5–8 environments.

Qualification point: ISO room classification does not itself define the required sterility, chemistry, cleaning frequency, or validated cleaning method. Use the room classification and procedure requirements together.


Wetting the sterile cover: preserve both chemistry control and aseptic technique

Because TM-MFP-516P-ST is dry, the facility must define how solution is introduced after or during sterile presentation.

  • Solution source: Use chemistry appropriate to the sterile or aseptic cleaning procedure.
  • Loading method: Define how the cover receives solution without compromising the controlled workflow.
  • Target wetness: Establish the surface condition required for the cleaning or disinfection step.
  • Over-wetting: Avoid unnecessary dripping, pooling, runoff, or loss of operator control.
  • Under-wetting: Avoid insufficient solution delivery for the intended task.

Process-control rule: The sterile cover defines the microbiological presentation; the SOP defines the chemistry and working wetness.


Large-surface technique: maintain sterile controls while cleaning systematically
  • Install without contaminating the working face: Follow the facility’s aseptic assembly technique.
  • Plan the cleaning route: Define start point, direction, overlap, and endpoint.
  • Maintain even surface contact: Keep the microfiber face engaged with the target surface.
  • Follow zoning controls: Change covers when moving between defined areas where required.
  • Avoid backtracking: Do not carry collected contamination over already completed surfaces without procedural justification.
  • Observe chemistry requirements: Maintain the wetness and contact conditions specified for the selected product.

Change-out triggers: sterility, contamination, area, wetness & handling events
  • Assigned area complete: The cleaning section designated for the cover has been completed.
  • Zone transition: A fresh sterile cover is required before moving to another area.
  • Contamination loading: The microfiber face reaches the defined process limit.
  • Insufficient wetness: The cover no longer delivers the required surface condition.
  • Aseptic breach: The cover contacts an uncontrolled or non-qualified surface.
  • Physical damage: The cover, pockets, or integrated pad becomes compromised.
  • Chemistry transition: The next cleaning step requires a different formulation or a fresh consumable.

Sterile-use rule: When sterility is required, an aseptic handling breach can be a change-out trigger even if the cover still appears clean and wet.


Best-practice use (sterile dry integrated-pad microfiber cover)
  1. Verify identification: Confirm TM-MFP-516P-ST, lot, expiration, and sterile status.
  2. Inspect package integrity: Do not use compromised sterile packaging.
  3. Perform material transfer: Follow the approved facility procedure.
  4. Prepare the reusable hardware: Ensure the frame and handle meet the required cleanliness status.
  5. Prepare the chemistry: Use the approved formulation and concentration.
  6. Open aseptically: Protect the sterile cover and working face.
  7. Install securely: Seat the pockets properly without uncontrolled contact.
  8. Wet according to procedure: Establish the required operating condition.
  9. Clean systematically: Maintain defined direction, overlap, zoning, and contact requirements.
  10. Replace at the first applicable limit: Include sterility breach, contamination, wetness, area, damage, and zone transitions.
  11. Dispose appropriately: Follow facility controls for the chemistry and contamination encountered.

Storage and shelf life: sterile covers use a 3-year manufacture-based period
  • Published Shelf Life: 3 years from date of manufacture for sterile mop covers
  • Storage Environment: Clean and dry
  • Published Storage Temperature: 59°F (15°C) to 85°F (30°C)
  • Expiration Control: Follow current product labeling and lot-specific records

Important distinction: Do not apply the five-year dry non-sterile cover shelf life to TM-MFP-516P-ST. Teknipure’s TDS assigns sterile mop covers a three-year shelf life.


5" x 16" family: sterile status changes the selection logic
  • TM-MFP-516P-ST: Sterile dry microfiber integrated-pad cover; individually bagged; 50 covers/case.
  • TM-MFP-516P: Non-sterile dry microfiber integrated-pad cover; individually bagged; 50 covers/case.
  • TM-MFPB-516P: Blue non-sterile dry microfiber configuration; 100 covers/case.
  • TM-MFPK-516P: Non-sterile dry integrated-pad configuration; 100 covers/case.
  • TM-MFP9G-516P: Non-sterile 9% IPA presaturated configuration; 80 covers/case.
  • TM-MFPK9G-516P: Non-sterile 9% IPA presaturated integrated-pad configuration; 50 covers/case.

Selection framework: Compare sterility + supplied chemistry + packaging + documented hardware + exact SKU. A matching 5" x 16" footprint does not make the products equivalent.


TM-MFP-516P-ST vs. TM-MFP-516P: same general format, different microbiological presentation
  • TM-MFP-516P-ST: Sterile, gamma irradiated, SAL 10-6.
  • TM-MFP-516P: Non-sterile.
  • Both: Dry, knit microfiber, 5" x 16", individually bagged, 50 covers/case.
  • Select -ST when: The approved procedure explicitly requires a sterile mop cover.
  • Select the non-sterile version when: Sterile presentation is not a requirement and the standard configuration meets the process need.

Substitution rule: Do not substitute the non-sterile SKU for the sterile SKU solely because size, material, and packaging appear similar.


Misuse controls & selection cautions
  • Do not treat sterile as presaturated: TM-MFP-516P-ST is dry.
  • Do not add a separate pad: an absorbent pad is already integrated.
  • Do not use compromised sterile packaging: package integrity is part of sterile product control.
  • Do not assume sterile cover = sterile assembled mop: hardware preparation and aseptic assembly remain required.
  • Do not call it lint-free: use low-linting contamination-control terminology.
  • Do not transfer TKM415 compatibility from adjacent SKUs: use the exact current TDS row.
  • Do not use the five-year non-sterile shelf life: sterile covers are listed at three years from manufacture.
  • Do not assume chemical compatibility equals efficacy: qualify the complete cleaning or disinfection method.

TM-MFP-516P-ST selection logic
  • Choose TM-MFP-516P-ST when: The process requires a sterile 5" x 16" microfiber mop cover with integrated absorbency.
  • Choose it when sterile transfer matters: Each cover is individually packaged.
  • Choose it when chemistry flexibility matters: The sterile cover is supplied dry.
  • Choose it when built-in absorbency matters: The integrated pad eliminates a separate pad component.
  • Use the documented frame system: TM-PFM516F or TM-PFM516HF.
  • Choose another SKU when: The procedure requires factory presaturation, a non-sterile cover, another packaging format, or different hardware.

Simple decision rule: If the procedure requires sterile microfiber pickup + integrated absorbency + facility-selected chemistry in a 5" x 16" pocket-cover format, TM-MFP-516P-ST is the purpose-built sterile configuration.


Why source TekniMop™ through SOSCleanroom
  • Exact-SKU selection: We can help distinguish sterile and non-sterile configurations with similar names and dimensions.
  • Sterility-aware selection: Review sterile presentation, packaging format, hardware, and cleaning chemistry together.
  • Packaging clarity: Confirm primary bag, pack, and case quantities before purchasing.
  • Documentation support: Request manufacturer TDS, certification, and lot-specific documentation where applicable.
  • One-cart procurement: Source mop covers and hardware alongside sterile IPA, disinfectants, wipers, gloves, and other critical-environment consumables.

Manufacturer documentation (authoritative references)
  • Teknipure TM-MFP-516P-ST product page: Click Here
  • TekniMop™ Large Surface Mopping Tools Technical Data Sheet: Click Here

Documentation hierarchy: Use the exact SKU, current product labeling, manufacturer documentation, expiration labeling, sterility documentation, and applicable lot records for final purchasing and qualification decisions. Packaging quantities in this Vault follow Teknipure’s August 2026 price list.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.