Skip to main content

Teknipure TM-MFP-516P TekniMop Microfiber Knit Pocket Mop Cover, Integrated Pad, 5″x16″ (Refills) (Case Qty.)

$444.19
SKU: TM-MFP-516P CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout
Type:
Dry Mop

Teknipure TM-MFP-516P TekniMop Microfiber Knit Pocket Mop Cover, Integrated Pad, 5″x16″ (Refills) (Case Qty.) - SOSCleanroom Standard Specification

The Teknipure TM-MFP-516P TekniMop™ Microfiber Knit Pocket Mop Cover is a dry, non-sterile cleanroom mop cover designed for large-surface cleaning in critical and controlled environments. Its knit microfiber construction supports effective capture and retention of small particles and contaminants, while the integrated absorbent pad provides added fluid capacity, cushioned surface contact, and controlled solution delivery for wet-cleaning applications.

Dry microfiber flexibility with integrated absorbency: TM-MFP-516P combines a 5" x 16" microfiber cleaning surface with an integrated absorbent pad and pocket-style attachment. Because it is supplied dry, facilities can select the cleaning or disinfecting chemistry and saturation level required by their established cleaning procedure.

Specifications:
  • Part Number: TM-MFP-516P
  • Product Type: Microfiber knit pocket mop cover
  • Size: 5" x 16" (13 cm x 41 cm)
  • Material: Knit microfiber
  • Pad: Integrated absorbent pad
  • Attachment: Pocket-style
  • Format: Dry
  • Sterility: Non-sterile
  • Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
  • Packaging: 1 cover/bag, 50 bags/case
  • Total Case Quantity: 50 covers/case
  • Compatible Hardware: TM-PFM516F and TM-PFM516HF
Where TM-MFP-516P Fits in Controlled Environments

TM-MFP-516P is designed for large-surface cleaning where facilities want the contamination-pickup characteristics of microfiber together with the flexibility of a dry mop cover. Its 5" x 16" footprint provides practical coverage for floors, walls, ceilings, equipment surfaces, and other broad cleaning areas.

The knit microfiber construction provides high surface contact to support capture and retention of small particles and contaminants. The integrated absorbent pad increases liquid-holding capacity and provides soft, cushioned contact with the target surface while supporting controlled release of cleaning or disinfecting solution.

Typical program fit: Cleanroom floor cleaning, wall cleaning, ceiling cleaning, large equipment and facility surfaces, precleaning before disinfectant application, particle and residue removal, disinfectant and sanitizer application, spill control, and general cleaning of large controlled-environment areas.

TM-MFP-516P is supplied dry and non-sterile. Final suitability should be evaluated according to the target surface, cleaning chemistry, contamination-control objective, required saturation level, sterile/non-sterile workflow, compatible hardware, and facility SOP.

About the Manufacturer:

Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, semiconductor and microelectronics manufacturing, optics, aerospace and defense, compounding pharmacies, laboratories, and other controlled environments.

Within the TekniMop™ large-surface cover family, Teknipure offers dry and presaturated microfiber formats in several constructions and sizes. These options allow facilities to select the combination of cleaning surface, liquid capacity, chemistry, and hardware that best fits their established cleaning procedure.

TM-MFP-516P Features:
  • Knit microfiber cleaning surface
  • 5" x 16" format for large-surface controlled-environment cleaning
  • Integrated absorbent pad for increased fluid capacity and cushioned surface contact
  • Pad covered on all sides to help prevent particle generation from exposed pad material
  • Pocket-style construction for secure installation on compatible mop hardware
  • Dry format allows facility-controlled chemistry selection and saturation
  • Microfiber construction captures and retains small particles and contaminants
  • Good absorbency and liquid retention for wet cleaning and spill-control applications
  • Controlled liquid release for consistent surface wetting
  • Compatible with IPA and common cleanroom disinfectants
  • Non-sterile configuration
  • Compatible with TM-PFM516F and TM-PFM516HF hardware
TM-MFP-516P Benefits:
  • Effective contamination pickup: Knit microfiber construction provides high surface contact to support capture and retention of small particles and contaminants.
  • Integrated-pad convenience: The built-in absorbent pad eliminates the need to purchase and install a separate mop pad.
  • Increased liquid capacity: The integrated pad provides additional fluid-holding capacity for wet-cleaning, disinfectant application, and spill-control procedures.
  • Flexible chemistry selection: The dry format allows facilities to select the cleaning or disinfecting chemistry required by the procedure.
  • Controlled saturation: Operators can establish the appropriate wetness level rather than relying on a predetermined factory-presaturated amount.
  • Cushioned surface contact: The absorbent pad provides a soft interface that helps maintain consistent contact across the cleaning surface.
  • Large-area efficiency: The 5" x 16" footprint provides useful coverage for floors, walls, ceilings, and other broad controlled-environment surfaces.
  • Reduced component handling: Integrating the absorbent pad into the cover removes a separate assembly step and an additional component from the cleaning system.
Common Applications:
  • Cleanroom floor cleaning
  • Wall cleaning
  • Ceiling cleaning
  • Large equipment and facility surfaces
  • Precleaning before disinfectant application
  • Particle and residue removal
  • Application of disinfectants and sanitizers
  • Controlled surface wetting
  • Spill control and liquid pickup
  • General cleaning of large controlled-environment areas
Best-Practice Use:
  • Install securely: Fit the pocket-style cover fully onto compatible mop hardware so the integrated absorbent pad remains evenly positioned beneath the microfiber cleaning surface.
  • Select the appropriate chemistry: Because TM-MFP-516P is supplied dry, apply the cleaning or disinfecting solution according to the chemistry manufacturer's instructions and facility SOP.
  • Control saturation: Wet the cover and integrated pad sufficiently for the procedure without unnecessary oversaturation, dripping, or excessive solution deposition.
  • Use controlled cleaning patterns: Follow the unidirectional, overlapping, or other validated mopping pattern established by the facility for the surface being cleaned.
  • Work from cleaner to less-clean areas: Follow the facility's established contamination-control sequence and avoid moving collected contamination back into previously cleaned areas.
  • Maintain even surface contact: Allow the microfiber surface and integrated absorbent pad to maintain consistent contact rather than relying on excessive downward pressure.
  • Observe required contact time: When applying disinfectants or sanitizers, maintain the required surface wetness and contact time specified by the chemistry manufacturer and facility procedure.
  • Change covers as required: Replace the cover according to surface area, contamination load, room transition, chemistry condition, or other changeout criteria established by the facility.
  • Follow non-sterile material controls: TM-MFP-516P is supplied non-sterile and should be introduced and used according to the facility's material-transfer and contamination-control procedures.
Selection Notes (TM-MFP-516P vs. Other TekniMop™ Options)
  • TM-MFP-516P: Choose this version when a dry 5" x 16" microfiber pocket cover is preferred and the facility needs direct control over cleaning chemistry and saturation.
  • TM-MFP9G-516P: Select the 9% IPA presaturated version when a ready-to-use chemistry format is preferred.
  • TM-MFP-516P-ST: Select the sterile dry version when sterile presentation is required while retaining facility control over cleaning chemistry.
  • TM-MFPK-516P: Compare this dry microfiber configuration when evaluating Teknipure's other integrated-pad 5" x 16" cover options.
  • TM-MFPK9G-516P: Select the 9% IPA presaturated integrated-pad version when standardized chemistry and increased liquid capacity are both desired.
  • Dry vs. presaturated: TM-MFP-516P provides maximum chemistry flexibility. Presaturated alternatives reduce point-of-use preparation when their supplied chemistry matches the validated process.
Compatible TekniMop™ Products

Compatible Mop Hardware

  • TM-PFM516F: 5" x 16" collapsible polyethylene mop frame
  • TM-PFM516HF: 5" x 16" collapsible polyethylene frame with extendable aluminum handle
Building a TM-MFP-516P TekniMop™ System

The TM-MFP-516P is the dry microfiber mop-cover component of a TekniMop™ large-surface cleaning system. Pair the cover with compatible 5" x 16" TekniMop™ mop hardware and prepare the cover with the cleaning chemistry and saturation level required by the facility's established procedure.

Frame + handle configuration:
TM-MFP-516P Microfiber Knit Mop Cover + TM-PFM516F Collapsible Polyethylene Frame + TM-PFM516H Extendable Aluminum Handle

Complete hardware configuration:
TM-MFP-516P Microfiber Knit Mop Cover + TM-PFM516HF Frame & Handle System

Workflow note: TM-MFP-516P is supplied dry and non-sterile. The facility therefore controls the cleaning chemistry and saturation level before use. Material transfer, solution application, cover changeout, surface wetting, use, and disposal should follow the applicable facility SOP.

Notes: Looking for application guidance or qualification context for the Teknipure TM-MFP-516P TekniMop™ Microfiber Knit Pocket Mop Cover? Open the SOSCleanroom Technical Vault tab above for detailed large-surface cleaning guidance, microfiber mop-cover selection, chemistry application, floor/wall/ceiling cleaning technique, system configuration, cover changeout considerations, and compatibility information.

SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.

Product page updated: Oct. 28, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
Knit Microfiber 5" x 16" Integrated Absorbent Pad Pocket Attachment Dry / Non-Sterile Individually Bagged 50 Covers/Case

Teknipure TekniMop™ TM-MFP-516P: individually bagged microfiber pocket covers with an integrated absorbent pad

The Teknipure TekniMop™ TM-MFP-516P is a 5" x 16" dry, non-sterile microfiber knit pocket mop cover with an integrated absorbent pad. Each cover is individually bagged, with 50 covers per case. The dry format leaves cleaning-solution selection and preparation under facility control. [1, 2]

Operations takeaway: This configuration combines a built-in absorbent backing with individually packaged dry covers. Specify the complete consumable and hardware combination, then define how the cover is prepared, introduced, used, and replaced during the cleaning procedure.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer: Teknipure
  • Part number: TM-MFP-516P
  • Product: TekniMop™ Microfiber Knit Pocket Mop Cover with Integrated Absorbent Pad
  • Nominal size: 5" x 16" (13 cm x 41 cm)
  • Cleaning material: Knit microfiber
  • Pad: Integrated absorbent pad
  • Attachment: Pocket-style
  • Supplied condition: Dry; not factory-presaturated
  • Sterility: Non-sterile
  • Cleanroom positioning: Manufacturer lists ISO Class 5–8
  • Packaging: 1 cover/bag, 50 bags/case
  • Total case quantity: 50 covers/case
  • Designated frame: TM-PFM516F collapsible polyethylene frame
  • Designated frame-and-handle kit: TM-PFM516HF

Configuration references: Teknipure product information, August 2026 mop price list, and the SKU-specific compatibility table in the Large Surface Mopping Tools TDS. [1, 2, 3]

Exact-SKU control: Preserve every character in TM-MFP-516P. Related 5" x 16" products have different packaging, supplied chemistry, or sterility status even when their names and appearance are similar.


Integrated absorbent pad: built-in liquid capacity and cushioning

Integrated absorbent pad: Built into the cover to provide additional liquid-holding capacity and cushioned surface contact without requiring a separate pad. [3]

Teknipure states that the pad is enclosed on all sides. The cleaning textile forms the exterior interface, while the internal component provides absorbency within the cover assembly. [2]

  • Before installation: Inspect the exterior, pockets, and overall assembly for damage.
  • During setup: Use the supplied cover without adding an unapproved backing layer.
  • During cleaning: Maintain suitable frame orientation rather than relying on cushioning to compensate for poor contact.
  • At replacement: Change the complete cover assembly according to the procedure.

Condition control: Remove a cover from use if damage exposes the internal pad, affects retention, or prevents the intended cleaning face from contacting the surface.


Individually bagged: one cover per opening
  • Primary package: 1 cover per bag
  • Case configuration: 50 individual bags
  • Total: 50 covers per case

Packaging follows the TM-MFP-516P entry in Teknipure’s August 2026 mop price list. [1]

Workflow implication: Individual bags allow the required units to be staged without opening a multi-cover bag. Define package removal, transfer, and opening in the facility procedure; individual packaging is not a substitute for those controls.


Non-sterile status: individual packaging is not a sterile designation

Teknipure identifies TM-MFP-516P as non-sterile and lists it for ISO Class 5–8 environments. [2]

  • Packaging requirement: Confirm whether individually bagged presentation meets the material-transfer method.
  • Sterility requirement: Select a manufacturer-designated sterile consumable when the procedure requires one.
  • Process qualification: Evaluate the cover, hardware, chemistry, surface, and handling method together.

Selection distinction: Do not infer sterility from an unopened bag, cleanroom positioning, or later exposure to a cleaning solution. These are separate product and process attributes.


Microfiber cleaning face: assess removal, not just wetting

Teknipure describes its microfiber cover family as low-linting and intended for particle, residue, and microorganism capture. [3]

  • Define the target: Identify the contamination or residue the cleaning step must remove.
  • Define acceptance: Establish how the treated surface will be checked.
  • Define the endpoint: Set a contamination-loading limit rather than relying only on remaining wetness.
  • Keep claims separate: Do not translate physical pickup into an antimicrobial kill claim or a zero-particle specification.

Qualification question: Does the complete method deliver the required surface condition? Visible wetting alone does not answer every cleaning-performance question.


Compatible hardware: the 5" x 16" polyethylene frame system

The SKU-specific TDS lists TM-PFM516F and TM-PFM516HF for TM-MFP-516P. Teknipure’s frame-and-handle kit page also explicitly lists this cover. [3, 4]

  • TM-PFM516F: Blue collapsible polyethylene frame, 5" x 16".
  • TM-PFM516H: Extendable aluminum handle for that frame, with a 4–6 ft working range.
  • TM-PFM516HF: Combined frame-and-handle kit.

Hardware descriptions and handle range follow Teknipure’s product records. [1, 4]

System configuration: TM-MFP-516P cover + TM-PFM516F frame + TM-PFM516H handle, or the corresponding TM-PFM516HF kit.


Pocket attachment: secure the cover before starting the cleaning zone

Teknipure describes the collapsible frame as facilitating cover replacement. [4] Follow the designated fitting method and check the assembled tool before use.

  • Prepare the hardware: Verify its required cleanliness status and inspect the frame and handle connection.
  • Fit the pockets: Seat the cover according to the frame instructions.
  • Check frame position: Confirm that the frame remains in its intended operating configuration.
  • Check alignment: Correct folds or displacement that interfere with contact.
  • Check retention: Confirm the cover stays seated through the planned movement.

Fit-control rule: Select by documented part-number compatibility, not size alone. A nominally similar frame still requires confirmation of retention and working-face contact.


Dry format: standardize preparation before standardizing performance

Dry describes the supplied condition. For a wet-cleaning task, the facility determines the compatible solution and preparation method. The operational considerations below are SOS guidance for procedure review, not manufacturer-validated loading volumes or hold times.

  • Solution: Identify the approved formulation and concentration.
  • Preparation equipment: Specify the containers and cleanliness controls used during wetting.
  • Loading method: Define how the cover receives solution and how consistency is checked.
  • Prepared-cover staging: Establish where the wetted assembly may be held and any permitted delay before use.
  • Working condition: Define the surface wetness or solution delivery required by the task.

Process-control point: Do not treat maximum absorbency as the required operating load. Establish the amount and method that achieve the intended result without unnecessary dripping, pooling, or runoff.


Chemistry compatibility: verify the actual solution and surface

Teknipure lists compatibility with IPA and common cleanroom disinfectants. [2]

  • Cover compatibility: Evaluate the selected formulation under its intended concentration and exposure conditions.
  • Surface compatibility: Consider the substrate, coatings, seals, and moisture-sensitive components.
  • Cleaning objective: Confirm that the method addresses the actual contamination.
  • Disinfection objective: Follow the selected disinfectant’s applicable directions and contact requirements.
  • Safety: Use the chemistry manufacturer’s current safety information and facility handling controls.

Important distinction: Material compatibility does not establish cleaning or disinfection efficacy. Qualify the complete method rather than approving it solely because the cover tolerates the solution.


Manufacturer-listed applications
  • Cleanroom floor, wall, and ceiling cleaning
  • Disinfectant and sanitizer application
  • Residue removal
  • Spill control
  • General large-area cleaning

Application reference: Teknipure TM-MFP-516P product information. [2]

Application boundary: A general use category is not approval for every spill, residue, or equipment surface. Match the cover and chemistry to the specific task and its handling requirements.


Large-surface technique: make coverage repeatable
  • Plan the route: Identify the start, boundaries, obstacles, and completion point.
  • Define overlap: Specify how adjacent passes will avoid untreated strips.
  • Verify contact: Check the working face against the target through the full pass.
  • Control progression: Follow the approved surface sequence and cleaning-zone rules.
  • Review surface orientation: Evaluate floor, wall, and ceiling setups at the actual handle length and working angle.

Coverage rule: Do not assign a universal square-foot capacity from nominal cover dimensions. Establish the working limit using the actual surface, contamination load, solution delivery, and cleaning pattern.


Change-out triggers: remaining liquid is not the only limit
  • Assigned area: The cleaning section or permitted coverage limit is complete.
  • Zone transition: The procedure requires a fresh cover before moving to another area.
  • Contamination: The working face is loaded, visibly soiled, or leaves an unacceptable result.
  • Solution delivery: The cover no longer provides the required surface condition.
  • Handling event: The cover contacts an uncontrolled surface.
  • Physical condition: Damage, displacement, or loss of retention interferes with use.
  • Process change: Another chemistry or cleaning step requires a new consumable.

Decision rule: Replace at the first applicable process limit. Do not return a used cover to fresh solution or add another chemistry unless the approved procedure specifically addresses that step.


Best-practice use (individually bagged dry pocket cover)
  1. Verify identification: Match the complete part number and supplied condition to the approved task.
  2. Check the package: Review integrity, labeling, expiration, and storage controls.
  3. Transfer the required units: Follow facility rules for individual bags and outer shipping packaging.
  4. Prepare the hardware: Confirm cleanliness, condition, and the correct frame-and-handle combination.
  5. Prepare the solution: Use the approved formulation, concentration, and safety controls.
  6. Open, install, and wet as specified: Follow the approved preparation sequence while protecting the cleaning face.
  7. Verify fit: Check alignment and retention before beginning the cleaning zone.
  8. Execute the method: Maintain the defined sequence, overlap, contact, and solution-delivery requirements.
  9. Replace at the limit: Apply the established contamination, wetness, area, or zoning trigger.
  10. Close out the task: Dispose of the used cover appropriately and prepare reusable hardware for storage or its next use.

Reusable-hardware preparation: keep platform requirements separate

Teknipure’s hardware table lists the polyethylene frame and aluminum handle in this system as not autoclavable. [3]

Processing boundary: Do not carry a carbon fiber hardware sterilization procedure over to this platform. Likewise, do not infer cover sterilization or reprocessing compatibility from a different frame’s rating. Prepare each component according to its applicable instructions and the approved facility method.


Storage and shelf life
  • Published dry-cover shelf life: 5 years from date of manufacture.
  • Storage: Clean, dry environment at 15°C–30°C.
  • Expiration control: Follow product labeling and applicable lot records.

Storage and shelf-life reference: Large Surface Mopping Tools TDS, page 1. [3]

Inventory distinction: A manufacture-based shelf life is not a reuse allowance or a hold time after wetting. Establish opened-package handling and prepared-cover staging separately.


Related 5" x 16" configurations: compare exact SKUs
  • TM-MFP-516P: Dry integrated-pad pocket cover; 1 cover/bag, 50 bags/case, 50 covers/case.
  • TM-MFP-516P-ST: Sterile dry integrated-pad pocket cover; 1 cover/bag, 5 bags/pack, 10 packs/case, 50 covers/case.
  • TM-MFP9G-516P: 9% IPA presaturated integrated-pad pocket cover; 10 covers/resealable gusset bag, 8 bags/case, 80 covers/case.
  • TM-MFPK-516P: Separately specified dry integrated-pad pocket cover; 10 covers/bag, 10 bags/case, 100 covers/case.

Descriptions and packaging follow the separate entries in Teknipure’s August 2026 mop price list. [1]

Comparison rule: These entries establish differences in supplied condition and packaging. They do not establish that one pad is thicker, more absorbent, or otherwise equivalent to another. Retain the exact SKU required by the approved specification.


TM-MFP-516P selection logic
  • Select this configuration when: The approved process calls for an individually bagged, dry, non-sterile 5" x 16" microfiber pocket cover with an integrated absorbent pad.
  • Confirm hardware: Use the documented frame system and verify the assembled fit.
  • Confirm preparation: Define compatible chemistry and wetting before standardizing the cleaning task.
  • Change configuration when required: Select the appropriate designated SKU when sterility, factory presaturation, or another packaging format is part of the specification.

Simple decision rule: Choose the required supplied condition and packaging first, confirm hardware compatibility, then qualify the complete cleaning method.


Qualification boundaries and misuse controls
  • No assumed sterility: Individual bagging does not change this SKU’s non-sterile designation.
  • No assumed core composition: Integrated absorbent pad describes the assembly without assigning an unconfirmed internal material.
  • No absolute particle claim: An enclosed pad is not a guarantee of zero particle release under every condition.
  • No inferred reuse: Do not assume permission to launder, replenish, or reprocess a used cover.
  • No universal chemistry approval: Review the actual formulation, surface, and exposure conditions.
  • No invented performance limits: Obtain applicable data before setting numerical particle, residue, absorbency, or coverage specifications.

Documentation rule: Manufacturer product specifications and SOS operational considerations serve different purposes. The guidance in this Vault supports selection and procedure review; it does not replace a facility-approved or validated cleaning process.


Why source TekniMop™ through SOSCleanroom
  • Exact-SKU selection: Get help distinguishing similar cover names, supplied conditions, and case packs.
  • System selection: Review the cover, designated frame, and working reach together.
  • Documentation support: Request manufacturer information for purchasing, qualification, and procedure review.
  • Coordinated procurement: Source mop covers and hardware alongside the other consumables required by the cleaning program.

Manufacturer documentation and technical references
  • [1] Teknipure Mops Price List, August 2026: Exact-SKU descriptions and controlling packaging quantities.
  • [2] Teknipure TM-MFP-516P product information: Supplied condition, integrated-pad construction, attachment, chemistry compatibility, cleanroom positioning, and applications.
  • [3] TekniMop™ Large Surface Mopping Tools TDS: Page 1 for storage and shelf life; page 4 for hardware processing limits; pages 5–6 for cover-family information and exact-SKU compatibility.
  • [4] Teknipure TM-PFM516HF product information: Collapsible polyethylene frame, extendable aluminum handle, and compatible cover listings.

Final acceptance: Use the exact SKU, specified order unit, product labeling, and applicable manufacturer records for purchasing and receiving. Process suitability remains subject to the facility’s qualification and operating requirements.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.