Skip to main content

Teknipure TM-MFP70G-415P TekniMop Microfiber Knit Pocket Mop Cover, Integrated Pad, 4″x15″, 70% IPA (Refills) (Case Qty.)

$816.63
SKU: TM-MFP70G-415P CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout
Type:
Pre-Wet Mop

Teknipure TM-MFP70G-415P TekniMop Microfiber Knit Pocket Mop Cover, Integrated Pad, 4″x15″, 70% IPA (Refills) (Case Qty.) - SOSCleanroom Standard Specification

The Teknipure TM-MFP70G-415P TekniMop™ Microfiber Knit Pocket Mop Cover is a non-sterile, ready-to-use cleanroom mop cover with an integrated foam pad and presaturation with 70% isopropyl alcohol (IPA) / 30% DI water. Designed for large-surface cleaning in critical and controlled environments, its knit microfiber construction supports effective capture and retention of particles and contaminants while the integrated pad provides increased liquid capacity, cushioned surface contact, and controlled solution release.

Microfiber cleaning + integrated pad + ready-to-use 70% IPA: TM-MFP70G-415P combines a high-density microfiber cleaning surface, integrated foam pad, and standardized 70% IPA / 30% DI water presaturation in a 4" x 15" pocket-style format. Self-standing resealable packaging helps reduce chemical evaporation and maintain consistent mop saturation between cover changes.

Specifications:
  • Part Number: TM-MFP70G-415P
  • Product Type: Presaturated microfiber knit pocket mop cover with integrated foam pad
  • Size: 4" x 15" (10 cm x 38 cm)
  • Material: Knit microfiber
  • Pad: Integrated foam pad
  • Attachment: Pocket-style
  • Solution: 70% isopropyl alcohol (IPA) / 30% DI water
  • Format: Presaturated
  • Sterility: Non-sterile
  • Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
  • Packaging: 10 covers/resealable gusset bag, 8 bags/case
  • Total Case Quantity: 80 covers/case
  • Compatible Frame: TKM415 TekniMop™ 4" x 15" Carbon Fiber Flat Mop Frame
Where TM-MFP70G-415P Fits in Controlled Environments

TM-MFP70G-415P is designed for large-surface controlled-environment cleaning where effective contamination pickup and standardized 70% IPA application are required in a ready-to-use format. Its 4" x 15" footprint provides practical coverage for floors, walls, ceilings, equipment surfaces, and other broad cleaning areas while remaining maneuverable on the compatible TKM415 frame.

The knit microfiber construction provides high surface contact to support capture and retention of small particles and contaminants. The integrated foam pad increases liquid-holding capacity and provides cushioned contact with the target surface while supporting controlled release of the presaturated solution for consistent surface wetting.

Typical program fit: Cleanroom floor cleaning, wall cleaning, ceiling cleaning, large equipment and facility surfaces, precleaning before disinfectant applications, residue removal, controlled 70% IPA application, surface wetting, and general cleaning of large controlled-environment areas.

TM-MFP70G-415P is supplied non-sterile and presaturated with 70% IPA / 30% DI water. Final suitability should be evaluated according to the target surface, required chemistry, contamination-control objective, sterile/non-sterile workflow, validated cleaning procedure, and facility SOP.

About the Manufacturer:

Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, interchangeable handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, semiconductor and microelectronics manufacturing, optics, aerospace and defense, compounding pharmacies, laboratories, and other controlled environments.

Within the TekniMop™ microfiber mop-cover family, Teknipure offers dry and presaturated configurations designed to combine effective contamination pickup with controlled liquid delivery. Integrated-pad designs simplify system setup by incorporating additional absorbency and cushioning directly into the mop cover.

TM-MFP70G-415P Features:
  • High-density knit microfiber cleaning surface
  • 4" x 15" format for large-surface controlled-environment cleaning
  • Integrated foam pad for increased fluid capacity and cushioned surface contact
  • Pad covered on all sides to help prevent particle generation from exposed pad material
  • Pocket-style construction for secure installation on the compatible frame
  • Presaturated with 70% IPA / 30% DI water
  • Ready-to-use format eliminates manual IPA measuring or spraying
  • Consistent solution delivery for repeatable surface wetting
  • Microfiber construction captures and retains small particles and contaminants
  • Low-particulate construction for contamination-control applications
  • Controlled and consistent liquid release from the integrated pad
  • Self-standing resealable gusset packaging
  • Resealable packaging helps reduce chemical evaporation and maintain mop saturation
  • Non-sterile configuration
  • Compatible with the TKM415 TekniMop™ carbon fiber flat mop frame
TM-MFP70G-415P Benefits:
  • Ready-to-use IPA application: Factory presaturation eliminates manual measuring, spraying, and saturation steps when 70% IPA is specified by the cleaning procedure.
  • Effective contamination pickup: High-density microfiber construction supports capture and retention of small particles and contaminants from critical surfaces.
  • Integrated-pad convenience: The built-in foam pad eliminates the need to purchase, install, and manage a separate mop pad.
  • Increased fluid capacity: The integrated foam pad provides additional liquid-holding capacity for controlled wet-cleaning procedures.
  • Controlled solution release: The presaturated integrated pad provides consistent liquid delivery for uniform surface wetting.
  • Cushioned surface contact: The foam pad provides a soft cleaning interface and helps maintain consistent contact across the target surface.
  • Large-area efficiency: The 4" x 15" footprint provides substantial cleaning coverage while maintaining maneuverability for floors, walls, ceilings, and equipment surfaces.
  • Reduced evaporation: Resealable packaging helps limit IPA evaporation and chemical loss from unused covers after opening.
  • Process consistency: Factory-controlled presaturation helps reduce variation associated with manually preparing individual mop covers.
  • Reduced component handling: Integrating the foam pad into the cover removes a separate assembly step and eliminates an additional component from the cleaning system.
Common Applications:
  • Cleanroom floor cleaning
  • Wall cleaning
  • Ceiling cleaning
  • Large equipment and facility surfaces
  • Precleaning before disinfectant applications
  • Particle and residue removal
  • Controlled 70% IPA application
  • Uniform surface wetting
  • General cleaning of large controlled-environment areas
Best-Practice Use:
  • Install securely: Fit the pocket-style cover fully onto the compatible TKM415 frame so the integrated foam pad remains evenly positioned beneath the microfiber cleaning surface.
  • Use directly from the presaturated package: TM-MFP70G-415P is supplied with 70% IPA / 30% DI water and does not require manual IPA saturation before use.
  • Reseal the package: Close the resealable gusset bag promptly after removing a cover to help minimize IPA evaporation and maintain saturation of the remaining covers.
  • Use controlled cleaning patterns: Follow the unidirectional, overlapping, or other validated mopping pattern established by the facility for the surface being cleaned.
  • Work from cleaner to less-clean areas: Follow the facility's established contamination-control sequence and avoid moving collected contamination back into previously cleaned areas.
  • Maintain even surface contact: Allow the microfiber surface and integrated foam pad to maintain consistent contact rather than relying on excessive downward pressure.
  • Follow the validated IPA procedure: Maintain the surface conditions and drying requirements established by the facility for 70% IPA cleaning.
  • Change covers as required: Replace the cover according to surface area, contamination load, room transition, solution condition, or other changeout criteria established by the facility.
  • Follow non-sterile material controls: TM-MFP70G-415P is supplied non-sterile and should be introduced and used according to the facility's material-transfer and contamination-control procedures.
Selection Notes (TM-MFP70G-415P vs. Other TekniMop™ Options)
  • TM-MFP70G-415P: Choose this version when a ready-to-use 70% IPA microfiber cover with an integrated foam pad is preferred for large-surface cleaning.
  • TM-MFP-415P: Select the dry microfiber pocket cover when the facility needs to choose its own cleaning chemistry or directly control saturation.
  • TM-PFM70G-415: Compare this alternative when evaluating Teknipure's other 4" x 15" presaturated microfiber configurations for the TKM415 system.
  • TM-PFM-415: Select a dry integrated-pad microfiber configuration when facility-controlled chemistry is required.
  • Dry vs. presaturated: TM-MFP70G-415P provides standardized ready-to-use 70% IPA delivery. Dry alternatives provide greater flexibility when different cleaning or disinfecting chemistries are required.
  • Integrated pad: The foam pad increases fluid capacity, provides cushioned surface contact, and eliminates the need to manage a separate pad component.
Compatible TekniMop™ Products

Compatible Carbon Fiber Frame

  • TKM415: 4" x 15" carbon fiber flat mop frame for floors, walls, ceilings, equipment surfaces, and other large controlled-environment cleaning applications
Building a TM-MFP70G-415P TekniMop™ System

The TM-MFP70G-415P is the presaturated microfiber mop-cover component of a modular TekniMop™ large-surface cleaning system. Pair the cover with the compatible TKM415 carbon fiber frame and select a TekniMop™ carbon fiber handle according to the required reach, surface orientation, and cleaning procedure.

System configuration:
TM-MFP70G-415P Microfiber Knit 70% IPA Mop Cover with Integrated Foam Pad + TKM415 Carbon Fiber Frame + Compatible TekniMop™ Carbon Fiber Handle

Select the handle according to the required working reach and surface orientation. The interchangeable TekniMop™ carbon fiber handle system allows the TKM415 frame to be configured for accessible floors and walls or extended for elevated walls, ceilings, and overhead surfaces.

Workflow note: TM-MFP70G-415P is supplied non-sterile and ready to use with 70% IPA / 30% DI water. The integrated foam pad is built into the cover, so no separate pad is required. Keep the resealable package closed when covers are not being removed to help minimize IPA evaporation. Material transfer, cover changeout, surface wetting, use, and disposal should follow the applicable facility SOP.

Notes: Looking for application guidance or qualification context for the Teknipure TM-MFP70G-415P TekniMop™ Microfiber Knit Pocket Mop Cover with Integrated Foam Pad? Open the SOSCleanroom Technical Vault tab above for detailed large-surface cleaning guidance, microfiber mop-cover selection, 70% IPA application considerations, floor/wall/ceiling cleaning technique, system configuration, cover changeout considerations, and compatibility information.

SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.

Product page updated: Oct. 28, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
Knit Microfiber 4" x 15" Integrated Pad Pocket Attachment 70% IPA Presaturated Non-Sterile 80 Covers/Case

Teknipure TekniMop™ TM-MFP70G-415P: presaturated microfiber pocket cover with integrated pad for large-surface cleanroom cleaning

The Teknipure TekniMop™ TM-MFP70G-415P is a 4" x 15" non-sterile microfiber knit pocket mop cover with an integrated pad, presaturated with 70% IPA / 30% DI water. Teknipure positions it for broad controlled-environment surfaces, including floors, walls, and ceilings. The cover combines a microfiber working face, integrated-pad construction, and ready-to-use alcohol presaturation in one consumable assembly. [1, 8]

Operations takeaway: Select the consumable around the required cleaning step, then establish the working pattern and change-out criteria. A ready-to-use cover simplifies preparation; it does not replace qualification of the complete cleaning method.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer: Teknipure
  • Part number: TM-MFP70G-415P
  • Product: TekniMop™ Microfiber Knit Pocket Mop Cover with Integrated Pad, 70% IPA
  • Nominal size: 4" x 15" (10 cm x 38 cm)
  • Cleaning material: Knit microfiber
  • Pad: Integrated pad
  • Attachment: Pocket-style
  • Condition: Presaturated
  • Solution: 70% isopropyl alcohol / 30% deionized water
  • Sterility: Non-sterile
  • Cleanroom positioning: Manufacturer lists ISO Class 5–8
  • Compatible frame: TKM415, 4" x 15" carbon fiber flat mop frame
  • Packaging: 10 covers/resealable gusset bag, 8 bags/case
  • Total case quantity: 80 covers/case

Product configuration references: Teknipure product information and frame compatibility listing. Integrated-pad designation and packaging quantities follow Teknipure’s August 2026 mop price list. [1, 3, 8]

Configuration-control point: Control this product by its complete part number. Material, integrated-pad construction, pocket attachment, presaturation, sterility status, and case quantity are separate attributes that should remain consistent across purchasing records and cleaning procedures.


Similar part numbers are not interchangeable specifications

Teknipure maintains separate listings for TM-MFP70G-415P and TM-PFM70G-415. The August 2026 product list describes TM-MFP70G-415P as a microfiber knit pocket cover with an integrated pad, while TM-PFM70G-415 is separately described as an integrated foam pad configuration. [8]

Configuration-control rule: Preserve the complete part number on orders, receiving records, and procedures. Do not approve a substitution based only on a shared size, microfiber description, or alcohol concentration.


Microfiber contact: evaluate removal, not just visible wetting

Teknipure describes its microfiber mop-cover family as low-linting and intended to collect particles, residues, and microorganisms. [2]

  • Define the target: Identify the residue or contamination the step must remove.
  • Check the result: Use the surface-acceptance criteria appropriate to the process.
  • Control loading: Establish when collected contamination requires a fresh cover.
  • Avoid absolute claims: Do not specify zero particle release or universal residue removal without supporting test data.

Qualification question: Does the assembled method achieve the required surface condition? A visibly wet surface alone is not the acceptance criterion for every cleaning task.


Presaturation: fewer preparation steps, not fewer process controls

The supplied format avoids an initial manual wetting step. [1] For a controlled process, document how the cover moves from its package to the surface and what conditions require replacement.

  • Before use: Verify the correct product, intact package, and acceptable expiration status.
  • During setup: Protect the working face from unintended contact.
  • During cleaning: Monitor the surface condition required by the procedure.
  • At depletion: Replace according to the approved method rather than improvising additional liquid.

Process boundary: Do not add water, alcohol, or another chemical to compensate for an unsuitable or depleted cover without a separately approved procedure.


Cleaning, disinfection, and sterility are different requirements

The applicable Teknipure SDS identifies technical cleaning as the recommended use. [4] CDC guidance also establishes that alcohol does not destroy bacterial spores; alcohol chemistry is not a substitute for a required sporicidal step. [5]

  • Cleaning objective: Define what must be removed from the surface.
  • Antimicrobial objective: Use product-specific efficacy information and applicable instructions rather than deriving a kill claim from alcohol percentage.
  • Contact requirements: Do not borrow a dwell time from a different formulation or product.
  • Sterility requirement: Do not substitute a non-sterile consumable where a sterile presentation is specified.

Important distinction: Microbial removal, microbial inactivation, and a consumable supplied sterile are separate concepts. The cleaning program must specify which controls are required at each step.


TKM415 compatibility: select reach separately from the cover

Teknipure’s TKM415 page lists this cover as compatible. The frame is a carbon fiber platform with two adjustable swivels and compatibility with the four listed TekniMop™ carbon fiber handles. [3]

  • Frame selection: Confirm that the footprint can reach the target boundaries without striking adjacent equipment.
  • Handle selection: Use the working range needed for the approved operator position.
  • Articulation: Configure the frame so the cleaning face remains controllable.
  • Assembly verification: Check retention and surface contact before starting the cleaning zone.

System principle: Cover compatibility does not automatically qualify every handle length, operating angle, or third-party frame. Review the complete assembly under the intended conditions.


Pocket installation: establish a stable working face
  • Prepare the frame: Verify its required cleanliness status and inspect for damage.
  • Follow the designated fitting method: Do not improvise retention or add an unapproved backing layer.
  • Check alignment: Correct folds or displacement that interfere with the intended cleaning face.
  • Check retention: Confirm the cover stays seated through the planned movement.

Setup control: The integrated pad is part of the cover assembly. Follow the approved installation method so the cover remains evenly positioned and securely retained on the compatible frame.


Packaging: 10 covers per bag, 80 covers per case
  • Primary package: 10 covers per resealable gusset bag
  • Case configuration: 8 bags per case
  • Total case quantity: 80 covers per case

This is the packaging configuration listed for TM-MFP70G-415P in Teknipure’s August 2026 mop price list. [8]

Purchasing and receiving control: Specify the exact part number and order unit. A complete case contains 8 bags of 10 covers; one individual bag contains 10 covers.


Opened-package control

Teknipure describes resealable gusset packaging intended to limit solvent loss. [1] Package handling should therefore be part of the procedure, not left entirely to operator preference.

  • Remove only the cover required for the task and close the package promptly.
  • Keep used covers and contaminated gloves away from the remaining contents.
  • Do not return a used cover to the package.
  • Define the response to a damaged closure, questionable wetness, or compromised contents.
  • Establish any opened-package use limit separately from the manufacture-based shelf life.

Large-surface technique: planned progression and overlap

General manufacturer mopping guidance supports systematic sections, overlapping linear passes, cleaner-to-less-clean progression, and top-down wall cleaning. [6] Apply those principles through the facility’s approved method rather than treating another mop system’s example as a validated instruction for this SKU.

  • Plan the route: Identify the starting point, boundaries, and completion point.
  • Define overlap: Specify how adjacent paths will avoid untreated strips.
  • Check contact: Verify that the intended working face reaches the surface throughout each pass.
  • Control transitions: Set clear rules for corners, edges, obstructions, and cleaning-zone boundaries.

Coverage limit: Do not assign a universal square-foot capacity or stroke count from cover dimensions. Establish the limit using the actual surface, soil load, technique, and required wetness.


Floor, wall, and ceiling work: qualify each setup
  • Floors: Plan operator movement so completed sections are not unnecessarily crossed.
  • Walls: Verify useful contact at the selected handle angle and define the response to runoff.
  • Ceilings: Evaluate the wetted cover, frame, and extended handle together before approving the setup.
  • Obstructed areas: Change to a more suitable approved tool when the frame cannot reach boundaries reliably.

SOS operational guidance: Do not assume that a comfortable floor-cleaning configuration is also suitable overhead. Evaluate control at the actual extension and orientation, not just at a nearby demonstration surface.


Change-out triggers: define the stopping point before cleaning begins
  • Area or zone: The assigned section is complete or the procedure requires a new cover.
  • Contamination: The working face is loaded, visibly soiled, or leaves an unacceptable result.
  • Wetness: The cover no longer provides the required surface condition.
  • Handling: The cover contacts an uncontrolled surface.
  • Condition: Damage, displacement, or poor retention interferes with use.
  • Process transition: A different chemistry or cleaning step requires a fresh consumable.

Decision rule: Replace at the first applicable limit. Remaining liquid is not permission to continue after a contamination or zoning limit has been reached.


Best-practice use (presaturated pocket-cover workflow)
  1. Verify identification: Match the complete SKU to the approved task and receiving documentation.
  2. Check the order unit: Confirm 10 covers per bag and 8 bags per complete case when receiving case quantities.
  3. Inspect the package: Check integrity, labeling, expiration, and storage history as required.
  4. Prepare the hardware: Confirm the frame and handle meet the task’s cleanliness and condition requirements.
  5. Apply safety controls: Follow the current SDS and facility requirements.
  6. Install and verify: Protect the cleaning face and check fit before use.
  7. Follow the approved route: Maintain the defined sequence, contact, and overlap.
  8. Check process limits: Replace at the established contamination, wetness, area, or zoning trigger.
  9. Complete subsequent treatment: Follow any separately specified disinfection or surface-release step.
  10. Close out the task: Dispose of the cover appropriately and prepare reusable hardware for storage or its next use.

Related options: distinguish chemistry from construction
  • TM-MFP-415P: A dry 4" x 15" microfiber knit pocket cover with an integrated pad for facility-selected compatible chemistry. [7, 8]
  • TM-PFM70G-415: A separately identified 4" x 15" presaturated integrated-foam product. Do not transfer its pad specifications or case pack to this SKU. [7, 8]
  • Another concentration: Treat any change in solution as a process change, not merely a purchasing substitution.
  • A sterile option: Select and qualify a manufacturer-designated sterile product when that presentation is required.

Selection framework: Confirm chemistry, sterility, construction, attachment, hardware, and packaging separately. A match on one attribute does not establish equivalence across the others.


Storage and shelf life

The TDS assigns three years from manufacture to 70% IPA presaturated mop covers and specifies clean, dry storage at 15°C–30°C. Use the supplied label and applicable lot records for actual expiration control. [2]

Inventory-control point: Receipt date and opening date do not restart a manufacture-based shelf life. Establish opened-package handling separately, and follow the SDS storage precautions in addition to the technical storage range.


Alcohol safety: use the SDS that names this SKU

Teknipure’s 65–90% IPA wipes and mop-cover SDS, revised September 21, 2026, explicitly includes TM-MFP70G-415P. It identifies Category 2 flammability, eye-irritation hazards, and potential drowsiness or dizziness from exposure. [4]

  • Keep the product away from heat, flames, sparks, and other ignition sources.
  • Provide appropriate ventilation and avoid inhaling vapors.
  • Use eye protection and select protective gloves according to exposure and chemical compatibility.
  • Retain closed original packaging and protect it from heat and direct sunlight.
  • Follow the SDS and facility procedure for incompatible materials and waste handling.

Safety summary reference: SDS Sections 2, 7, 8, and 13. [4]


Qualification boundaries: do not fill data gaps with assumptions
  • Particle and residue limits: Obtain applicable test data before establishing quantitative acceptance criteria.
  • Liquid loading: Request SKU-specific information when volume per cover is a controlled requirement.
  • Surface compatibility: Evaluate the actual material, coating, residue, and exposure conditions.
  • Reuse or reprocessing: Do not infer permission to launder, resterilize, or replenish a used cover.
  • Hardware ratings: A frame’s autoclave designation does not establish cover compatibility with that cycle.

Documentation rule: Operational recommendations in this Vault are considerations for procedure development, not manufacturer-validated performance limits or instructions to change an approved process.


Why source TekniMop™ through SOSCleanroom
  • Exact-SKU support: Get help distinguishing similar product names, chemistry options, and packaging configurations.
  • System selection: Review the cover, designated frame, and required working reach together.
  • Documentation support: Request current manufacturer information for purchasing, qualification, and procedure review.
  • Coordinated purchasing: Source mopping consumables alongside the other supplies required by the cleaning program.

Manufacturer documentation and technical references
  • [1] Teknipure TM-MFP70G-415P product information: Product positioning, presaturation, intended applications, and package features.
  • [2] TekniMop™ Large Surface Mopping Tools TDS: Supporting cover-family information, storage guidance, and shelf-life information.
  • [3] Teknipure TKM415 product information: Designated frame compatibility and hardware features.
  • [4] Teknipure 65–90% IPA Cleaning Wipes and Mop Covers SDS: Revision September 21, 2026; product identification and safety controls.
  • [5] CDC Chemical Disinfectants guidance, Alcohol section: General antimicrobial limitations, not a product-specific efficacy claim.
  • [6] Texwipe AlphaMop Mopping Guide: General technique reference only; its example coverage limits are not assigned to this Teknipure cover.
  • [7] Teknipure TM-MFP-415P and TM-PFM70G-415 product information: Related dry and integrated-foam configurations.
  • [8] Teknipure Mops Price List, August 2026: Exact-SKU integrated-pad designation and controlling packaging specification: 10 covers/resealable gusset bag, 8 bags/case, 80 covers/case.

Final acceptance: Use the exact SKU, specified packaging configuration, product labeling, and applicable manufacturer records for purchasing and receiving. Cleaning performance and process suitability remain subject to the facility’s approved qualification and operating procedures.