Skip to main content

Texwipe TX8723 PolySat 6" x 11" Polypropylene Wiper Pre-Wetted 70% IPA for Small Spaces

$10.70
SKU: TX8723 BAG CURRENTLY IN STOCK
(No reviews yet)
Availability:
CURRENTLY IN STOCK
Shipping:
Calculated at Checkout
International Shipping:
Restricted to U.S. destinations only
Type:
Pre-Wet Wiper
Family:
PolySat
Material:
Polypropylene
Wiper Size:
6" x 11"
Wiper Edge:
Cut Edge
ISO Class:
ISO 5 (Class 100) - ISO 8 (Class 100,000)
Country of Origin:
Made in the USA

Texwipe TX8723 PolySat® 6" x 11" Polypropylene Cleanroom Wipers - Pre-Wetted 70% IPA / 30% DIW - 75/Bag - 1,800/Case

Texwipe TX8723 PolySat® is a non-sterile, pre-wetted cleanroom wiper manufactured from 100% melt-blown polypropylene with a cut-edge construction. Designed for controlled surface cleaning, the narrow 6" x 11" format is particularly convenient for smaller workspaces, equipment housings, drawers, fixtures, pass-through areas, and other locations where a larger wiper may be difficult to handle.

Each TX8723 wiper is factory pre-wetted with 70% USP-grade isopropyl alcohol (IPA) and 30% deionized water (DIW). The wetting solution is filtered to 0.2 µm before packaging. This ready-to-use presentation helps reduce manual alcohol dilution, individual-wiper wetting, and the need to apply free liquid using spray bottles or squeeze bottles in restricted working areas.

The soft, melt-blown polypropylene substrate is manufactured for low particle and extractables contribution during appropriate cleaning operations. Its flexible nonwoven structure supports wiping of compatible sensitive surfaces while resisting snagging during normal use on suitable equipment and components.

TX8723 is supplied in easy-to-use peel-and-reseal bags containing 75 pre-wetted wipers each. A manufacturer case contains 24 bags, totaling 1,800 individual wipers. The reclosable packaging helps reduce IPA evaporation and unnecessary exposure of unused material between dispensing events.

Texwipe identifies TX8723 for ISO Classes 5 through 8 and EU GMP Grades B through D. The product is non-sterile and should be selected according to the facility's approved cleaning procedures, surface-compatibility requirements, particle and residue limits, and contamination-control program.

TX8723 is also NSF-certified as an A1 general cleaner for qualifying cleaning applications in and around food-processing areas. This classification is subject to specific use restrictions and does not authorize unrestricted direct food contact. All food products and packaging materials must be removed or protected before use, and cleaned surfaces must receive a potable-water rinse after application.

Narrow-Format Cleaning Advantage: TX8723 combines a compact 6" x 11" polypropylene substrate with manufacturer-prepared 70% IPA / 30% DIW, controlled solution filtration, and convenient peel-and-reseal packaging. Its narrow geometry helps operators clean smaller areas and constrained equipment surfaces without relying on oversized wipers or separately applied solvent.

Specifications:
  • Manufacturer: Texwipe, an ITW company
  • Manufacturer Part Number: TX8723
  • Product Family: PolySat®
  • Product Type: Non-Sterile Pre-Wetted Cleanroom Wiper
  • Material: 100% melt-blown polypropylene
  • Fabric Construction: Soft nonwoven
  • Edge Treatment: Cut edge
  • Color: White
  • Nominal Open Size: 6" x 11" (15 cm x 28 cm)
  • Primary Configuration: Narrow-format pre-wetted wiper
  • Wetting Solution: 70% isopropyl alcohol / 30% deionized water
  • IPA Quality: USP grade
  • Solution Filtration: 0.2 µm
  • Presentation: Factory pre-wetted, ready to use
  • Quantitative Solvent Loading: No specific mL/wiper or g/wiper loading established by the reviewed TDS
  • Sterility: Non-sterile
  • Manufacturer Cleanroom Classification: ISO Classes 5-8
  • Traditional Cleanroom Classes: Class 100-100,000
  • EU GMP Environment: Grades B-D, subject to site qualification
  • NSF Classification: A1 general cleaner
  • Food-Processing Use: Subject to NSF A1 conditions and required potable-water rinse
  • Direct Food Contact: Not an unrestricted direct food-contact cleaning product
  • Typical Particles ≥0.5 µm: 13 x 106 particles/m²
  • Typical Fibers >100 µm: 4,500 fibers/m²
  • Typical Sorptive Capacity: 360 mL/m²
  • Typical Sorptive Rate: Less than 0.3 seconds
  • Typical Basis Weight: 34 g/m²
  • Packaging: Peel-and-reseal bag
  • Wipers per Bag: 75
  • Bags per Manufacturer Case: 24
  • Total Wipers per Case: 1,800
  • SOSCleanroom Quantity Options: Individual bag or full manufacturer case
  • Manufacturer Lot Identification: Lot coded
  • Published Shelf Life: 3 years from date of manufacture
  • Country of Manufacture: USA
  • Manufacturer Quality Registration: ISO 9001
  • Primary Application: General controlled-environment surface cleaning
  • Use: Disposable, single-use wiper
  • Disinfectant Status: No independently established registered disinfectant or sporicidal claim
  • Manufacturer Technical Reference: TEX-LIT-TDS-013 Rev. 00-05/18
Packaging and Manufacturer Case Configuration:

Texwipe TX8723 is packaged in a convenient peel-and-reseal bag intended for controlled dispensing of pre-wetted wipes. The reclosable format helps minimize solution evaporation during normal use, provided the package is closed properly between dispensing events.

Purchase Configuration Packaging Total Wipers
Individual Bag 1 peel-and-reseal bag containing 75 wipers 75
Manufacturer Case 24 bags of 75 wipers each 1,800

The 75-count bag offers a compact point-of-use format for controlled workplaces. The 24-bag manufacturer case provides convenient quantities for recurring cleaning programs and distribution to multiple approved work areas.

Packaging Confirmation: TX8723 contains 75 wipes per peel-and-reseal bag and 24 bags per manufacturer case, totaling 1,800 wipes. TX8727 is a related 6" x 11" PolySat® refill configuration and should not be confused with the standard TX8723 bag presentation.

About the Manufacturer:

Texwipe, an ITW company, manufactures cleanroom wipers, swabs, cleaning-validation products, and contamination-control supplies for pharmaceutical manufacturing, biotechnology, medical devices, semiconductor processing, laboratories, food-processing environments, and other controlled industries.

The PolySat® product family uses soft melt-blown polypropylene with factory-prepared IPA/DIW wetting chemistry. Different sizes and packaging configurations allow customers to select a suitable wiping format for their equipment and cleaning needs.

SOSCleanroom is an authorized Texwipe distributor, providing manufacturer product documentation, wiper-selection assistance, packaging information, and procurement support for contamination-controlled facilities.

TX8723 Features:
  • 100% melt-blown polypropylene substrate
  • Soft nonwoven construction
  • Cut-edge wiping material
  • Narrow 6" x 11" nominal dimensions
  • Convenient handling for constrained workspaces
  • Low-linting material designed for general cleanroom cleaning
  • Pre-wetted with 70% USP-grade IPA / 30% DIW
  • 0.2 µm filtered wetting solution
  • Factory-prepared, ready-to-use chemistry
  • Controlled wetness for repeatable wiping
  • Non-sterile presentation
  • ISO Classes 5-8 manufacturer positioning
  • EU GMP Grades B-D environmental positioning
  • NSF A1 general-cleaner listing
  • Manufactured for low levels of particles and extractables
  • Designed to resist snagging during appropriate wiping of abrasive surfaces
  • Peel-and-reseal dispensing package
  • Reduced need for manual alcohol dilution and wetting
  • Lot-coded manufacturer packaging
  • Three-year manufacturer-published shelf life
  • 75 wipers per bag
  • 24 bags per case
  • 1,800 wipers per manufacturer case
TX8723 Benefits:
  • Narrow-Format Access: The 6" width helps operators manage wiping tasks in drawers, equipment sections, and constrained work areas.
  • Controlled Surface Coverage: The 11" length provides wiping reach while maintaining a narrower working profile.
  • Soft Polypropylene: Supports cleaning of compatible sensitive surfaces when used with an appropriate procedure.
  • Low Particle Design: Manufactured to control particle and extractables contribution during general cleaning.
  • Repeatable Cleaning Chemistry: Factory-prepared 70% IPA / 30% DIW helps reduce mixing variability.
  • Less Free-Liquid Handling: Pre-wetted wipes reduce the need to spray or pour alcohol onto work surfaces.
  • Convenient Dispensing: Peel-and-reseal bags allow access to the required quantity without opening a separate bulk container.
  • Evaporation Management: Proper closure helps maintain the wetness of unused wipes.
  • Reduced Solvent Application Variability: Pre-wetted material reduces differences associated with individual operators manually wetting wipes.
  • Suitable for General Residue Removal: Helps collect compatible light soils, lubricants, and processing aids.
  • NSF A1 Listing: Provides a documented general-cleaner classification for qualified food-processing uses.
  • Traceability: Manufacturer lot coding supports receiving and quality records.
  • Flexible Purchasing: Individual 75-count bags and full manufacturer cases accommodate different operating volumes.
Common Applications:
  • Wiping smaller or confined equipment workspaces
  • Cleaning compatible production equipment surfaces
  • Wiping drawers, fixtures, carts, and staging surfaces
  • General cleanroom workstation cleaning
  • Cleaning pass-through accessories under approved procedures
  • Removal of compatible lubricants and handling residues
  • Cleaning small components and production parts
  • Wiping cleanroom equipment housings
  • Routine cleaning in qualified ISO Class 5-8 environments
  • Controlled cleaning of tools and accessories
  • Cleaning compatible items before controlled-area introduction
  • Selected electronics and microelectronics support-area cleaning
  • General laboratory and medical-device production support
  • Approved cleaning in food-processing areas under NSF A1 conditions
  • Applications where a full-width 9" x 11" wipe is unnecessarily large
  • Cleaning procedures requiring factory-prepared 70% IPA wiping chemistry
Narrow-Format Polypropylene Construction:

TX8723 combines a narrow 6" x 11" format with a soft melt-blown polypropylene substrate. This construction is intended to help operators control wiping contact in smaller workspaces while maintaining sufficient wiping length for suitable surfaces.

  • Melt-Blown Polypropylene: Provides a soft, flexible synthetic wiping material.
  • Cut-Edge Construction: Suitable for general wiping but does not provide sealed-border edge containment.
  • Narrow Geometry: Helps reduce folding and handling of oversized wipers in confined areas.
  • Surface Contact: The material is designed for compatible sensitive surfaces.
  • Normal Abrasion Resistance: Texwipe identifies PolySat® as resistant to easy snagging during appropriate wiping of abrasive surfaces.
  • Particle and Extractables Control: Manufactured to provide low contamination contribution under the applicable test methods.
  • Critical Surfaces: Evaluate a sealed-edge polyester alternative when the procedure has more demanding fiber or particulate limits.
  • Material Compatibility: Confirm compatibility between polypropylene, IPA, the surface, and any residue being removed.

Size Selection Guidance: TX8723's narrower geometry is beneficial where working room and wipe handling are limited. It is not automatically the best choice for every large-surface cleaning task. Select the wipe size according to access, surface coverage, contamination requirements, and approved wiping procedures.

70% IPA / 30% DIW Chemistry and Solvent Loading:

TX8723 is pre-wetted with 70% USP-grade IPA and 30% DIW using a solution filtered to 0.2 µm. Texwipe identifies the PolySat® formulation as providing repeatable wetness and volatile organic compound (VOC) levels under its manufacturing controls.

  • 70% IPA: Supports removal of compatible oils, processing aids, and light surface residues.
  • 30% DIW: Supplies the water component of the formulated wetting solution.
  • USP-Grade IPA: Confirmed by Texwipe for TX8723.
  • 0.2 µm Filtration: Applied to the solution used in pre-wetting.
  • Factory Pre-Wetting: Reduces variability associated with manual dilution and wipe saturation.
  • Controlled Wetness: Supports repeatable cleaning when the package is handled correctly.
  • Quantitative Loading: A specific volume or mass of solution per wipe is not stated in the reviewed manufacturer TDS.
  • Evaporation: IPA can be lost from exposed wipes and improperly closed bags.
  • Material Compatibility: Evaluate coatings, adhesives, plastics, labels, finishes, and other IPA-sensitive materials.
  • Non-Sterile Presentation: Solution filtration does not establish sterility of the finished wiper.
  • Disinfectant Claims: The 70% IPA concentration alone does not establish a validated disinfectant contact time or organism-specific efficacy.
  • Sporicidal Requirements: Use an appropriately qualified sporicide when specified by the procedure.

Solvent Loading Guidance: Texwipe confirms the 70% IPA / 30% DIW formulation and controlled pre-wetting, but the referenced TDS does not publish a fixed milliliter-per-wipe loading for TX8723. When a qualified process requires an exact quantitative solvent-loading specification, request the applicable information directly from Texwipe.

NSF A1 Food-Processing Cleaner Classification:

Texwipe TX8723 PolySat® is NSF-certified as an A1 general cleaner for permitted applications on surfaces in and around food-processing areas. This classification carries specific handling and rinse requirements.

  • NSF Category: A1 general cleaner.
  • Application Area: Qualifying surfaces in and around food-processing areas.
  • Direct Food Contact: Not intended for direct contact with food.
  • Food Protection: Remove or protect all food products before cleaning.
  • Packaging Protection: Remove or protect food-packaging materials before use.
  • Post-Cleaning Requirement: Rinse cleaned surfaces with potable water after application.
  • Procedure Compliance: Follow the applicable food-facility cleaning and sanitation procedures.
  • No Automatic Sanitizer Claim: NSF A1 general-cleaner listing does not independently establish registered sanitizer or disinfectant efficacy.
  • Residue Conditions: Texwipe reports no noticeable odor or visible residue when the product is used according to its instructions.

Important NSF A1 Use Requirement: Before using TX8723 in food-processing or food-handling facilities, remove or protect food products and packaging materials. After cleaning, rinse the cleaned surfaces with potable water. Do not interpret NSF A1 as unrestricted authorization for direct food-contact use.

Recommended Wiping Procedure:

TX8723 is designed for convenient controlled wiping. In narrow workspaces, proper dispensing, folding, wipe replacement, and solvent management help prevent contamination from being pushed into corners or redeposited on cleaned surfaces.

  1. Confirm the Application: Verify the wiper, chemistry, and cleanroom classification are appropriate for the task.
  2. Inspect the Bag: Check for damage, leakage, or compromised closure.
  3. Prepare the Workspace: Follow the facility's approved equipment cleaning and safety instructions.
  4. Use Appropriate PPE: Wear approved cleanroom gloves and other required protective equipment.
  5. Open the Package: Peel back only the necessary portion of the closure.
  6. Remove a Wiper: Avoid touching or contaminating the remaining wipes.
  7. Reseal Immediately: Limit evaporation and environmental exposure.
  8. Fold for Control: Create manageable wiping faces where the approved SOP permits.
  9. Wipe Systematically: Use straight, overlapping strokes in the prescribed direction.
  10. Avoid Excessive Pressure: Prevent unnecessary abrasion on sensitive surfaces.
  11. Change Wiping Faces: Avoid returning contaminated portions of the wipe to cleaned areas.
  12. Replace as Needed: Discard wipes that are dry, soiled, damaged, or unsuitable for the next area.
  13. Prevent Reuse: Never return a used wiper to its original bag.
  14. Apply Special Requirements: Follow the potable-water rinse requirement where NSF A1 food-processing use applies.
  15. Document Cleaning: Complete required production or environmental cleaning records.

Wiping Guidance: Narrow equipment areas can make cross-contamination and solvent pooling more difficult to manage. Use the facility's approved cleaning pattern, avoid excessive wetting, and replace wipes before contamination is transferred to another surface.

Peel-and-Reseal Packaging and Evaporation Control:

TX8723's peel-and-reseal bag allows operators to remove individual wipers while keeping the remaining contents enclosed. Maintaining proper closure helps preserve the manufacturer-prepared solvent condition and supports consistent wiping throughout normal use.

  • Open Only When Needed: Minimize unnecessary exposure of unused wipers.
  • Reseal Promptly: Close the package securely after dispensing.
  • Protect the Opening: Prevent contact with contaminated gloves, tools, and equipment.
  • Limit Heat Exposure: Avoid conditions that accelerate evaporation.
  • Inspect Wetness: Do not use inadequately wetted wipers when a defined wetness is required.
  • Do Not Re-Wet Without Authorization: Adding solvent may change the approved chemistry and package condition.
  • Follow Open-Pack Limits: Apply the facility's approved in-use requirements.
  • Maintain Lot Information: Retain manufacturer identification when required for traceability.
  • Use Appropriate Storage: Follow the applicable manufacturer SDS and flammable-material requirements.

Packaging Guidance: Resealable packaging reduces evaporation but does not prevent all solvent loss after opening. If wipers become unexpectedly dry, inspect closure integrity, storage conditions, handling, and the approved open-package use period.

Typical Particle, Fiber, Ionic and Extractables Performance:

Texwipe publishes typical analytical data for the PolySat® polypropylene substrate. These values may assist material selection but are not guaranteed TX8723 lot-specific acceptance criteria.

Typical Manufacturer Characteristic Reported Value
Particles ≥0.5 µm 13 x 106 particles/m²
Fibers >100 µm 4,500 fibers/m²
Nonvolatile Residue - IPA Extractant 0.001 g/m²
Nonvolatile Residue - DIW Extractant 0.005 g/m²
Sodium 0.3 ppm
Potassium 0.2 ppm
Chloride 0.15 ppm
Sorptive Capacity 360 mL/m²
Sorptive Rate Less than 0.3 seconds
Basis Weight 34 g/m²

These values describe typical PolySat® material characteristics under referenced test methods. Actual cleaning results depend on the substrate, surface, chemistry, contamination levels, and wiping technique.

Performance Data Guidance: Manufacturer typical analyses are not lot-specific specifications or guarantees that a particular cleaning process will meet its acceptance criteria. For critical surface requirements, evaluate the current TDS and applicable facility validation or qualification data.

Selection Notes: TX8723 vs. Other PolySat® Wipers:

Texwipe provides different PolySat® sizes and packaging formats. TX8723 is distinguished by its narrow 6" x 11" size and 75-count peel-and-reseal bag. Other products may be more suitable for larger surfaces, alternative dispensing systems, or sterile cleaning procedures.

Product Size Presentation Manufacturer Packaging
TX8723 6" x 11" Non-sterile, 70% IPA, NSF A1 75/bag; 24 bags/case; 1,800 wipers
TX8727 6" x 11" Non-sterile, 70% IPA, refill configuration 75/refill bag; 20 bags and 1 container/case
TX1040 7" x 11" Non-sterile, 70% IPA 200/bag; 4 bags/case; 800 wipers
TX1051 9" x 11" Non-sterile, 70% IPA 50/flexpack; 24 packs/case; 1,200 wipers
TX3213 9" x 11" Sterile, 70% IPA 50/flexpack; 20 packs/case; 1,000 wipers
  • Choose TX8723: When narrow-format wiping and compact 75-count bags are preferred.
  • Choose TX8727: When the related refill format and reclosable container are preferred.
  • Choose TX1040: For a slightly wider 7" x 11" wiper supplied in 200-count slider bags.
  • Choose TX1051: For larger 9" x 11" general-purpose polypropylene wiping.
  • Choose TX3213: Where a sterile polypropylene wipe is required by the approved procedure.
  • Confirm Food-Processing Conditions: Do not transfer TX8723's NSF A1 listing to other PolySat® SKUs without verifying their separate approvals.
  • Check Substrate and Case Count: Similar IPA chemistry does not make different configurations automatically interchangeable.

Product Selection Guidance: TX8723 is the narrow 6" x 11" PolySat® format with 75 wipes per bag and NSF A1 general-cleaner listing. Choose the correct product according to surface access, sterility, contamination-control requirements, packaging, and the facility's approved cleaning program.

Safety and Chemical Compatibility:

TX8723 contains IPA, a flammable solvent. The pre-wetted format helps reduce separate liquid handling but does not eliminate chemical hazards, surface-compatibility requirements, or the need for approved cleaning procedures.

  • Flammability: Keep away from sparks, open flames, heat, and ignition sources.
  • Ventilation: Follow workplace controls for alcohol vapor exposure.
  • Personal Protective Equipment: Use gloves, eye protection, and other equipment required by the current SDS and facility procedures.
  • Surface Compatibility: Evaluate coatings, adhesives, plastics, labels, and sensitive finishes before use.
  • Electrical Equipment: Follow equipment-approved cleaning and electrical safety instructions.
  • Non-Sterile Material: Do not substitute for sterile wiping consumables when sterile presentation is required.
  • Disinfection: Do not assume registered disinfectant efficacy or a universal microbial contact time.
  • Sporicidal Requirements: Use a separately qualified sporicide where required.
  • Food-Processing Areas: Follow NSF A1 use restrictions and complete the required potable-water rinse.
  • Hazardous Drug Residues: Do not assume IPA wiping alone provides validated hazardous-drug deactivation or decontamination.
  • Shipping: Subject to applicable current dangerous-goods classification, package quantity, transportation mode, and carrier requirements.
  • Waste Disposal: Follow procedures for solvent-containing and contaminated wiping materials.

Safety Guidance: TX8723 is non-sterile and pre-wetted with flammable 70% IPA. Use only on compatible surfaces and follow the applicable Safety Data Sheet, facility cleaning procedures, and NSF A1 instructions when used in food-processing environments.

Shelf Life, Storage and Disposal:
  • Manufacturer Part Number: TX8723
  • Individual Package: 75 pre-wetted polypropylene wipers
  • Manufacturer Case: 24 bags / 1,800 wipers
  • Supplied Sterility: Non-sterile
  • Published Shelf Life: 3 years from manufacture
  • Expiration: Follow manufacturer labeling
  • Traceability: Manufacturer lot identification
  • Packaging Condition: Inspect for damage, leakage, or compromised seals
  • Storage: Follow applicable manufacturer SDS and flammable-material requirements
  • Ignition Sources: Keep away from sparks, flames, and excessive heat
  • Material Introduction: Follow facility requirements for controlled areas
  • Dispensing: Protect unused material from unnecessary contact
  • Evaporation Control: Reseal immediately after dispensing
  • Opened-Bag Handling: Apply approved in-use limits
  • Food-Processing Use: Observe NSF A1 conditions and the potable-water rinse requirement
  • Wiper Condition: Discard dry, soiled, damaged, or otherwise compromised wipes
  • Reuse: Single use only
  • Disposal: Follow approved alcohol-containing waste procedures
Manufacturer Technical Documents:

Texwipe TX8723 Official Manufacturer Product Information: Click Here

Texwipe PolySat® Technical Data Sheet - TEX-LIT-TDS-013 Rev. 00-05/18 (PDF): Click Here

Texwipe TX8723 Safety Data Sheet: View Manufacturer Technical Downloads

SOSCleanroom TX8723 Product Information: Click Here

Other Similar Products Available From SOSCleanroom.com

PolySat® Pre-Wetted and Alternative Cleanroom Wipers

Notes: Need assistance choosing narrow-format pre-wetted wipes, comparing PolySat® packaging options, or confirming NSF A1 cleaning requirements? SOSCleanroom can help with product selection, manufacturer technical documentation, packaging quantities, and procurement requirements.

SOSCleanroom.com supports pharmaceutical, biotechnology, medical device, semiconductor, laboratory, food-processing, and other controlled environments with cleanroom wipers, pre-wetted cleaning products, and contamination-control supplies.

Product description updated: November 3, 2026 (SOS Technical Staff)

© 2026 SOS Supply. All rights reserved.

The Technical Vault By SOSCleanroom
ISO Class 5–8 EU GMP Grades B–D Nonsterile 100% Melt-Blown Polypropylene Cut Edge 70% USP-Grade IPA / 30% DIW 0.2 µm Filtered Solution 6" × 11" Open NSF A1 75 Wipers / Bag 1,800 Wipers / Case

Texwipe TX8723 PolySat®: narrow-format polypropylene wipers for controlled 70% IPA cleaning in confined work areas

Texwipe TX8723 PolySat® Pre-Wetted Cleanroom Wipers are nonsterile, disposable cleaning wipers made from 100% melt-blown polypropylene with cut edges. They are pre-wetted with a 0.2 µm-filtered solution of USP-grade 70% isopropyl alcohol (IPA) and 30% deionized water (DIW).

TX8723 uses a distinctive 6" × 11" (15 × 28 cm) open format, supplied folded to approximately 6" × 4". This presentation is particularly useful where storage space, equipment clearance, and controlled point-of-use handling make a larger wiper less convenient.

The soft polypropylene substrate supports cleaning compatible production surfaces, equipment parts, carts, fixtures, and sensitive surfaces. The factory-prepared IPA solution helps reduce variation associated with manually saturating dry wipes or dispensing solvent from open bottles.

Texwipe identifies TX8723 for ISO Classes 5–8 / Classes 100–100,000 and EU GMP Grades B–D. Its manufacturer specifications also identify the product as NSF A1 certified for use as a general cleaner in and around food-processing areas, subject to specific protection and rinsing requirements.

Each peel-and-reseal bag contains 75 wipers. A manufacturer case includes 24 bags, totaling 1,800 individual wipers.

Operations takeaway: TX8723 combines a narrow polypropylene wiping format, standardized 70% IPA chemistry, low typical material extractables, and resealable packaging. Its practical advantage is controlled wiping in limited workspaces, provided the cleaning procedure addresses surface compatibility, solvent migration, wipe change-out, and contamination transfer.


ISO-first context: controlled cleaning where equipment access is limited

ISO 14644-5:2025 provides an operational framework for managing cleanroom contamination through controls involving personnel, equipment, materials, cleaning, maintenance, and environmental monitoring.

Wiping materials must be selected according to their cleanliness, solvent compatibility, substrate construction, handling characteristics, and the environment in which they will be used.

In compact equipment areas, a cleaning tool must also be capable of reaching the intended surface without excessive folding, uncontrolled dragging across surrounding features, or unintended liquid transfer into adjacent components.

TX8723's narrow unfolded width and compact folded presentation provide a practical option for these applications. However, the facility must confirm that the wipe physically fits the intended access path and that the wiping method achieves its cleaning objective.

Control point: Texwipe's current product documentation identifies ISO Classes 5–8, not ISO 5–9, as its product-specific cleanroom designation. Selection must still consider the facility's contamination-control strategy and any applicable requirement for sterile supplies.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Product: Texwipe PolySat® Pre-Wetted Cleanroom Wiper
  • Manufacturer: Texwipe, an ITW company
  • Manufacturer part number: TX8723
  • Product family: PolySat®
  • Product category: Pre-wetted polypropylene cleanroom wiper
  • Sterility: Nonsterile
  • Material: 100% melt-blown polypropylene
  • Construction: Nonwoven
  • Edge: Cut edge
  • Nominal unfolded dimensions: 6" × 11" (15 × 28 cm)
  • Folded dimensions: Approximately 6" × 4" per the TX8723-specific manufacturer documentation
  • Pre-wet chemistry: 70% IPA / 30% DIW
  • IPA quality: USP-grade
  • Solution filtration: 0.2 µm
  • Cleanroom environment: ISO Classes 5–8
  • Legacy classification: Classes 100–100,000
  • EU GMP environment: Grades B–D
  • Food-processing designation: NSF A1 general cleaner, subject to specified conditions
  • Packaging: Peel-and-reseal bag
  • Quantity per bag: 75 wipers
  • Bags per manufacturer case: 24
  • Total wipes per case: 1,800
  • Manufacturer lot coding: Yes
  • Published shelf life: Three years from manufacture
  • Country of manufacture: USA
  • Current manufacturer TDS: PolySat® Technical Data Sheet, TEX-LIT-TDS-013 Rev. 00-05/18
  • Historical TX8723-specific document: IPA Pre-Wetted Wiper for Small Footprint Areas, effective December 2012

Ordering control: TX8723 = 75 wipers per bag × 24 bags per case = 1,800 wipes per case. Do not confuse TX8723 with TX8727, the related refill configuration supplied with a different case arrangement.


6" × 11" open and 6" × 4" folded: understanding the geometry

The TX8723 configuration is intended for operations where wipe footprint and dispensing convenience are important. Texwipe's original TX8723-specific sheet describes the wipe as 6" × 4" folded and 6" × 11" open.

  • Unfolded width: 6 inches.
  • Unfolded length: 11 inches.
  • Folded presentation: Approximately 6" × 4".
  • Storage: Compact folded wipes are practical for small workstations and cleaning carts.
  • Surface contact: The material can be unfolded for broader contact or refolded according to the approved method.
  • Constrained access: A narrow format may reduce unnecessary contact with surrounding equipment features.
  • Wiping faces: Folding permits sequential use of clean surfaces where the SOP allows.
  • Equipment clearance: Confirm actual fit before using the wipe inside narrow channels or openings.
  • Mechanical handling: Avoid forcing a folded wiper into openings that could cause snagging or material damage.

Dimensional distinction: The folded size is a packaging and handling configuration, not a guarantee that TX8723 can enter every 6-inch-wide or smaller space. Accessibility also depends on equipment depth, geometry, obstructions, glove clearance, and the required wiping motion.


Why the narrow format matters for confined workspaces
  • Drawers and compartments: Helps manage wiping where larger sheets can be cumbersome.
  • Tool interiors: Supports controlled cleaning of appropriately accessible equipment surfaces.
  • Fixture boundaries: Allows more localized wiping around compatible features.
  • Pass-through staging: Useful for approved wipe-downs of smaller items and surfaces.
  • Mobile carts: Compact packaging reduces storage space at the point of use.
  • Small benches: A reduced footprint may help limit unnecessary material contact.
  • Injection mold cleaning: Can be evaluated for compatible mold surfaces and processing residues.
  • Seams and interfaces: Requires special care to avoid pushing solvent or contamination into concealed areas.
  • Surface qualification: Confirm cleaning efficiency and residue removal on representative equipment features.

Application limitation: Smaller or narrower is not automatically better. For large open surfaces, a larger wipe may provide better coverage and require fewer changes. TX8723 should be selected when its geometry improves actual handling without compromising cleaning effectiveness.


100% melt-blown polypropylene: material construction and cleaning behavior

TX8723 is manufactured from soft melt-blown polypropylene, a synthetic nonwoven material designed for compatible general cleaning applications in controlled environments.

  • 100% polypropylene: Synthetic substrate without a cellulose component.
  • Melt-blown construction: Produces a nonwoven wiping surface.
  • Soft contact: Supports use on appropriately qualified sensitive surfaces.
  • Cut edges: Identifies the actual edge construction.
  • Particle control: Manufacturer processing is intended to limit particles and extractables.
  • Abrasion resistance: Texwipe positions the product for contact with suitable abrasive surfaces without easy snagging.
  • Liquid interaction: The material is supplied with a prepared 70% IPA solution.
  • Single use: Replacing used wipes helps limit contamination carryover.
  • Critical finishes: Evaluate a specialized or sealed-border product where stricter requirements apply.

Construction distinction: TX8723 uses cut-edge polypropylene, not sealed-border polyester. Softness and low-linting positioning do not establish scratch-free or particle-free performance on every surface.


70% USP-grade IPA / 30% DIW: solvent chemistry and filtration
  • IPA concentration: 70% of the supplied formulation.
  • Water: 30% deionized water.
  • IPA grade: USP-grade, explicitly identified for TX8723 in the manufacturer TDS.
  • Solution filtration: 0.2 µm.
  • Prepared chemistry: Helps reduce operator variation from manual dilution.
  • Ready-to-use handling: Reduces the need for separate bottle saturation.
  • Residue cleaning: May assist removal of compatible lubricants, adhesives, and processing aids.
  • Evaporation: Alcohol loss can affect wetness during extended exposure.
  • Surface compatibility: Must be confirmed for plastics, coatings, elastomers, adhesives, and other relevant materials.

Filtration and sterility: 0.2 µm filtration does not mean the finished product is sterile. TX8723 is designated nonsterile. It does not have the gamma-irradiated sterile assurance claim of separately identified sterile PolySat® products.


Pre-wet solvent loading: what the manufacturer establishes

Texwipe describes its PolySat® products as supplying repeatable wetness and controlled volatile organic compound (VOC) delivery through factory-prepared pre-wetting.

  • Supplied formulation: 70% IPA / 30% DIW.
  • Factory preparation: Reduces mixing and liquid-dispensing variability.
  • Repeatable wetness: Supports general cleaning consistency.
  • Measured loading: The reviewed current TDS does not publish a numeric milliliter-per-wiper loading.
  • Sorptive capacity: A separate laboratory measure of the substrate's liquid-holding characteristics.
  • Evaporation control: Prompt package resealing helps protect remaining wipe wetness.
  • Coverage area: Determine the usable surface area by process qualification.
  • Wet-contact requirements: Must be established separately for any disinfection procedure.
  • Under-wetted wipes: Replace when the required cleaning step cannot be completed correctly.

Loading limitation: There is no verified exact mL-per-wipe specification in the reviewed Texwipe documentation. Do not convert the published sorptive capacity into a guaranteed amount of IPA solution contained in each TX8723 wipe.


Typical PolySat® cleanliness and physical properties

Texwipe's currently linked PolySat® TDS, TEX-LIT-TDS-013 Rev. 00-05/18, provides the following typical material analyses.

  • Basis weight: 34 g/m²
  • Sorptive capacity: 360 mL/m²
  • Sorptive rate: Less than 0.3 seconds
  • Particles ≥0.5 µm: 13 × 106 particles/m²
  • Fibers >100 µm: 4,500 fibers/m²
  • NVR, IPA extractant: 0.001 g/m²
  • NVR, DIW extractant: 0.005 g/m²
  • Sodium: 0.3 ppm
  • Potassium: 0.2 ppm
  • Chloride: 0.15 ppm
  • Particle and fiber test references: IEST-RP-CC004.3, ASTM E2090-12, Texwipe TM22
  • NVR test: Texwipe TM1
  • Ionic test: Texwipe TM18
  • Absorbency test: Texwipe TM20

Data interpretation: These numbers are typical PolySat® material analyses rather than guaranteed TX8723 lot-release limits. Measurement units and extraction methods differ. Obtain a controlled manufacturer specification or appropriate lot documentation when a defined maximum is required.


Particles, fibers, NVR, and ions: practical contamination risks
  • Particles: May be introduced through material release or transfer of contamination collected during wiping.
  • Fibers: Can be significant for precision assemblies, optics, and exposed product surfaces.
  • Nonvolatile residue: Can remain after solvent evaporation and may affect critical surface requirements.
  • Ionic contamination: May be relevant to corrosion-sensitive and electrical assemblies.
  • Wiping pressure: Excessive force can increase substrate abrasion.
  • Surface texture: Rough or sharp features can influence material release.
  • Wipe change-out: Replace loaded faces to reduce redeposition.
  • Qualification: Compare contamination contributions against actual facility acceptance limits.

Cleanliness principle: A low-linting designation does not mean zero particles or fibers. Where final residue or particle requirements are especially strict, test the full wiping process and consider a different qualified substrate or edge construction.


Peel-and-reseal bag: solvent preservation and controlled dispensing
  1. Verify the product: Confirm TX8723 and applicable lot details.
  2. Inspect packaging: Check for punctures, leakage, and closure damage.
  3. Follow material entry: Apply the approved procedure to the external package.
  4. Open the seal: Expose only the necessary dispensing area.
  5. Remove a wipe: Avoid touching unused wipes with contaminated gloves.
  6. Reseal immediately: Limit solvent evaporation and environmental exposure.
  7. Keep the opening clean: Protect resealable contact surfaces from transferred residues.
  8. Inspect wipe wetness: Confirm suitability for the prescribed operation.
  9. Do not refill: Avoid adding unqualified IPA or other liquids to the bag.
  10. Follow open-pack restrictions: Apply the facility's defined use period and disposition criteria.

Packaging control: The resealable presentation reduces avoidable solvent loss, but does not establish an indefinite open-package life, sterile barrier, or guaranteed unchanging solvent concentration after repeated handling.


Controlled wiping procedure for small or recessed work areas
  1. Confirm the SOP: Verify TX8723 is approved for the location and cleaning step.
  2. Confirm physical access: Check that the wipe and gloved operator can reach the surface safely.
  3. Evaluate compatibility: Confirm both IPA and polypropylene are suitable for the equipment.
  4. Inspect the wipe: Check wetness and physical condition.
  5. Fold appropriately: Use the prescribed configuration to establish clean wiping faces.
  6. Start at the qualified surface: Follow the facility's specified cleaning sequence.
  7. Use directional strokes: Apply controlled overlapping passes where practical.
  8. Manage seam contact: Avoid pushing unwanted liquid or contamination underneath sensitive interfaces.
  9. Control pressure: Do not force the wiper against abrasive or delicate features.
  10. Change wiping faces: Avoid transferring collected residues into adjacent areas.
  11. Replace loaded wipes: Follow the method's change-out criteria.
  12. Maintain required wetness: Use additional wipes as necessary.
  13. Observe required contact times: Follow approved procedures where disinfection is intended.
  14. Dispose appropriately: Use the designated alcohol-waste procedure.
  15. Reseal unused material: Protect remaining wipes.
  16. Document completion: Record cleaning according to the applicable quality system.

Method standardization: Define the allowed wipe folds, contact pressure, wiping direction, overlap, surface coverage, change-out, and treatment of seams or enclosed components. A narrower wiper does not eliminate the need for a reproducible cleaning procedure.


Avoiding solvent migration in tight equipment features
  • Seams: Avoid forcing alcohol beneath assembled interfaces where liquid could remain trapped.
  • Open electrical contacts: Follow the equipment manufacturer's cleaning and isolation requirements.
  • Adhesive joints: Check compatibility before repeated alcohol exposure.
  • Elastomer seals: Evaluate chemical resistance and swelling concerns.
  • Vent openings: Do not introduce liquid into areas not approved for wet cleaning.
  • Equipment recesses: Confirm adequate drying and residue removal.
  • Precision assemblies: Monitor for films, residue, or trapped contamination after cleaning.
  • Controlled application: Use appropriate pressure rather than squeezing excessive fluid from the wipe.

Constrained-access limitation: Pre-wetted delivery reduces the need for separately poured liquid but does not eliminate solvent migration or pooling risks. The facility must verify that the cleaning method is appropriate for the equipment design.


NSF A1 designation: food-processing use with specific restrictions

Texwipe identifies TX8723 as NSF-certified for use as a general cleaner (A1) on surfaces in and around food-processing areas under specified conditions.

  • NSF category: A1 general cleaner.
  • Intended setting: Surfaces in and around food-processing areas.
  • Direct food contact: The manufacturer does not intend use directly on food.
  • Food protection: Remove or protect food products before applying TX8723.
  • Packaging protection: Remove or protect food packaging materials during cleaning.
  • Post-cleaning rinse: A potable-water rinse of cleaned surfaces is required after use.
  • Odor and visible residue: Manufacturer describes these outcomes when used as instructed.
  • Facility controls: Follow the food facility's approved sanitation SOP and relevant requirements.

NSF A1 limitation: Food products and packaging must be removed or protected, and cleaned surfaces require a potable-water rinse after use. NSF A1 does not establish direct-food-contact suitability without these restrictions or replace an approved food-safety cleaning procedure.


Cleaning versus disinfection: understanding 70% IPA
  • Cleaning: Physical wiping helps remove soils, lubricants, and compatible processing residues.
  • Alcohol chemistry: May support an approved alcohol-based microbial-control step.
  • Disinfectant claims: Require applicable regulatory authorization or facility-specific validation.
  • Wet-contact time: Must be supported by the actual product and procedure requirements.
  • Evaporation: Alcohol can evaporate before a required contact time is complete.
  • Sporicidal treatment: Do not assume 70% IPA replaces a required sporicide.
  • Heavy soil: May require separate cleaning before disinfection.
  • Sterile status: TX8723 is nonsterile.
  • Compounding applications: Follow the facility's applicable USP <797> and <800> requirements.

Critical distinction: 70% IPA does not automatically establish sterile supply, sporicidal efficacy, or a validated disinfection contact time. Use a product and procedure supported by the intended microbial-control objective.


TX8723 versus TX1051: narrow versus larger PolySat® formats
  • TX8723 material: 100% melt-blown polypropylene.
  • TX1051 material: 100% melt-blown polypropylene.
  • TX8723 unfolded size: 6" × 11".
  • TX1051 size: 9" × 11".
  • TX8723 folded size: Approximately 6" × 4".
  • TX8723 package: 75 wipes per peel-and-reseal bag.
  • TX1051 package: 50 wipes per flexpack.
  • TX8723 case: 24 bags, 1,800 wipes.
  • TX1051 case: 24 flexpacks, 1,200 wipes.
  • Both solutions: 70% IPA / 30% DIW.
  • Both products: Nonsterile, cut-edge polypropylene.
  • TX8723 selection: Compact handling and limited-width work areas.
  • TX1051 selection: Broader surfaces where more coverage per wipe is useful.

Selection principle: TX8723 and TX1051 share the PolySat® substrate and cleaning chemistry but differ in dimensions and packaging. Choose by usable surface area, accessibility, wipe consumption, and approved dispensing controls.


TX8723 versus TX8727: bags and refill-container supply
  • TX8723: 6" × 11" PolySat® 70% IPA wipes.
  • TX8723 bag quantity: 75.
  • TX8723 case: 24 bags, totaling 1,800 wipes.
  • TX8727: Related 6" × 11" PolySat® 70% IPA refill configuration.
  • TX8727 refill bag: 75 wipes.
  • TX8727 case: 20 refill bags plus one reclosable container.
  • TX8727 case wipe total: 1,500.
  • TX8723 handling: Individual peel-and-reseal bags.
  • TX8727 handling: Refill-container workflow requiring appropriate refill and cleaning controls.
  • Selection: Choose the format supported by the facility's dispensing, storage, and contamination-control procedure.

Critical packaging difference: TX8723 includes 24 bags per case; TX8727 includes 20 refill bags plus a reclosable container. Do not combine these case configurations when quoting or approving a product substitution.


TX8723 PolySat® versus TechniSat® and AlphaSat®
  • TX8723 PolySat®: 100% melt-blown polypropylene, 6" × 11", 70% IPA.
  • TX1045 TechniSat®: 55% cellulose / 45% polyester nonwoven, 6" × 8", 70% IPA.
  • TX1036 AlphaSat®: 100% continuous-filament knitted polyester, 6" × 6", 70% IPA.
  • Polypropylene: Offers a soft synthetic wiping surface with PolySat® material characteristics.
  • Cellulose/polyester: Provides different liquid absorption, particle, and extractables characteristics.
  • Knitted polyester: Provides a different fabric structure and fiber-release profile.
  • All three specified products: Nonsterile.
  • All three specified formulations: 70% IPA / 30% DIW.
  • Critical selection: Compare substrate, edge, particles, fibers, NVR, absorbency, and surface compatibility.

Material comparison: Identical IPA concentration does not make polypropylene, cellulose/polyester, and knitted polyester wiping systems interchangeable. Process qualification must account for the actual material and application.


Nonsterile TX8723 versus sterile PolySat® alternatives
  • TX8723: Nonsterile PolySat® 6" × 11".
  • TX1051: Nonsterile PolySat® 9" × 11".
  • TX3213: Sterile PolySat® 9" × 11", 50 wipes per flexpack.
  • TX3216: Sterile PolySat® 9" × 11", 20 wipes per flexpack.
  • Sterile versions: Manufacturer identifies gamma irradiation and SAL 10-6 for the designated sterile products.
  • TX8723: Has no finished-product sterility or SAL claim.
  • Material transfer: Use the procedure appropriate to the product's actual sterile status.
  • Substitution: Do not replace sterile wiping material with TX8723 where sterile supply is mandatory.

Sterility principle: Nonsterile TX8723 may be suitable for selected ISO Class 5–8 cleaning tasks, but it must not be represented as sterile or equivalent to gamma-irradiated sterile PolySat® products.


Packaging hierarchy: 75 wipes per bag and 1,800 per case
  • Manufacturer part number: TX8723.
  • Individual wiper: 6" × 11" nonsterile polypropylene pre-wetted with 70% IPA.
  • Primary package: Peel-and-reseal bag.
  • Wipers per bag: 75.
  • Bags per case: 24.
  • Case total: 1,800 wipes.
  • Lot coding: Manufacturer lot identification.
  • Receiving: Confirm SKU, quantity, package condition, and relevant lot details.
  • Cleanroom entry: Apply the approved material-transfer procedure.
  • Dispensing: Reseal promptly between uses.

Case calculation: 75 wipes × 24 bags = 1,800 wipes per manufacturer case. A bag and a case represent different purchasing quantities and should be identified correctly in procurement records.


Three-year shelf life and inventory controls
  • Manufacturer-published shelf life: Three years from manufacture.
  • Actual expiration: Verify the lot-specific label and quality documentation.
  • Package condition: Inspect for leakage, tears, punctures, and failed closures.
  • Evaporation: Minimize unnecessary exposure after opening.
  • Heat: Follow manufacturer and SDS storage requirements.
  • Ignition control: Apply appropriate alcohol-product storage precautions.
  • Inventory rotation: Use approved first-expiring-first-out practices.
  • Traceability: Maintain applicable manufacturer lot identification.
  • Compromised product: Investigate packages exhibiting unexpected dryness or contamination.
  • Open-pack use: Follow facility-defined in-use restrictions.

Shelf-life control: The manufacturer's published three-year shelf life begins at manufacture, not delivery. Use the actual supplied lot information to determine remaining usable life.


IPA safety: flammability, ventilation, and transport
  • Ignition hazards: Keep away from flames, sparks, hot equipment, and other ignition sources.
  • Ventilation: Follow facility requirements for controlling alcohol vapor exposure.
  • Gloves: Select hand protection compatible with IPA.
  • Eye protection: Follow the applicable chemical exposure assessment.
  • Electrical equipment: Apply appropriate shutdown and manufacturer cleaning instructions.
  • Storage: Use the current product SDS and applicable flammable-material controls.
  • Spills: Follow the approved isopropyl alcohol response procedure.
  • Waste: Dispose of used solvent-wetted wipes according to facility and regulatory requirements.
  • Transportation: Determine the correct hazardous-material designation for the package and shipment.
  • Carrier requirements: Verify any air, ground, international, or quantity restrictions.

Shipping limitation: Texwipe states that shipping classification depends on inner-package weight. Do not assume that obsolete ORM-D wording establishes the product's current ground, air, or international shipping eligibility.


Typical applications for TX8723
  • Cleaning compatible small workspaces and equipment compartments
  • Wiping tool exteriors and accessible internal surfaces
  • Controlled cleaning of production fixtures
  • Cleaning compatible pass-through staging surfaces
  • Wiping suitable cleanroom carts and workstations
  • Removing compatible processing aids and lubricants
  • Cleaning approved sensitive surfaces
  • Controlled wiping of suitable injection molds
  • Cleaning appropriate small manufacturing parts
  • Gowning-room touchpoint cleaning where nonsterile wipes are permitted
  • NSF A1 general-cleaner applications following food protection and potable-water rinsing requirements
  • Operations where a compact pre-wetted package reduces space and handling demands

Application selection: TX8723 is useful where compact handling and standardized solvent delivery are important. Verify actual equipment access, substrate compatibility, cleanliness limits, and the complete cleaning method for each application.


Common wiping failures and prevention
  • Bag left open: Reseal promptly to limit evaporation.
  • Insufficient wetness: Replace wipes that no longer meet the required process condition.
  • Liquid migration: Avoid pushing solvent beneath seals, edges, and equipment interfaces.
  • Excessive pressure: Prevent avoidable abrasion or damage to sensitive surfaces.
  • Contamination redeposition: Change faces and use new wipes when needed.
  • Uncontrolled strokes: Follow the approved directional wiping pattern.
  • Streaking or haze: Reassess solvent compatibility, residue load, material, and finishing procedure.
  • Incorrect ISO designation: Use current manufacturer ISO Classes 5–8.
  • Incorrect case count: Confirm 75 per bag and 1,800 per case.
  • Wrong sterile assumption: Recognize TX8723 is nonsterile.
  • Food-area rinsing omitted: Follow the NSF A1 potable-water rinse requirement.
  • Expired or compromised product: Apply the facility's disposition procedure.

Misuse controls & when not to use TX8723
  • If sterile wipes are required: Select a separately qualified sterile product.
  • If sealed edges are mandatory: Do not substitute cut-edge TX8723 without approval.
  • If extremely low particle or fiber levels are required: Evaluate another qualified substrate.
  • If the equipment cannot tolerate IPA: Use approved alternative chemistry.
  • If solvent pooling can damage equipment: Select a method that controls liquid migration.
  • If a sporicidal process is required: Use the approved sporicidal agent.
  • If disinfectant efficacy must be established: Use applicable efficacy evidence and the correct procedure.
  • If used in food-processing areas: Do not omit product and packaging protection or the potable-water rinse.
  • If a wipe is dry or visibly contaminated: Replace it.
  • If exact mL-per-wipe loading is mandatory: Obtain manufacturer-controlled data or qualify the loading separately.
  • If flammable solvents cannot be used: Select another appropriate cleaning system.
  • If the procedure specifies another product: Evaluate substitutions through approved change control.

Recommended related cleanroom products

System compatibility: Compare wiper size, substrate, sterile status, chemical formulation, packaging, and cleanliness data before approving a substitution. The same 70% IPA formulation does not establish equivalent wiping performance across different materials.


Why purchase Texwipe TX8723 from SOSCleanroom
  • Exact manufacturer product: TX8723 PolySat® 6" × 11" nonsterile polypropylene pre-wetted wipe.
  • Correct packaging: 75 wipes per bag and 1,800 per manufacturer case.
  • Cleanroom-focused selection: Compare narrow-format, full-size, sterile, and alternative-substrate wipes.
  • Manufacturer technical information: Review current PolySat® material performance and SDS resources.
  • Repeat-order consistency: Use the exact TX8723 manufacturer part number to reduce unintended substitutions.
  • Customer assistance: Contact SOSCleanroom for current availability, documentation, and purchasing support.

Manufacturer documentation (authoritative references)
  • SOSCleanroom TX8723 Product Page: Click Here
  • Texwipe TX8723 Official Manufacturer Product Information: Click Here
  • Texwipe PolySat® Technical Data Sheet — TEX-LIT-TDS-013 Rev. 00-05/18: Click Here
  • Texwipe TX8723-Specific Historical Technical Data Sheet — Effective December 2012: Click Here
  • Texwipe TX8723 Safety Data Sheet and Technical Downloads: Click Here
  • SOSCleanroom PolySat® Product Selection: Click Here

Technical documentation: Texwipe identifies TX8723 as a nonsterile, 100% melt-blown polypropylene cut-edge wiper, measuring 6" × 11" unfolded and pre-wetted with 0.2 µm-filtered USP-grade 70% IPA / 30% DIW. Current product information establishes ISO Class 5–8 suitability, NSF A1 general-cleaner designation with specified food protection and rinsing conditions, 75 wipes per bag, 24 bags per case, and a three-year shelf life. Typical material-performance data should not be interpreted as guaranteed individual-lot specification limits.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.