The Technical Vault
By SOSCleanroom
15-Gauge Nylon
Foam Nitrile Palm
ZONZ™ Comfort Fit
ANSI Cut A1
EN 388 3131A
HyFlex 11-801: breathable comfort and tactile control for light-duty industrial handling
The Ansell HyFlex® 11-801 combines a
15-gauge nylon liner, foam nitrile palm coating, ZONZ™
Comfort Fit Technology, and a knitwrist cuff. It is designed
for light-duty mechanical handling requiring dexterity,
abrasion resistance, and grip in dry and slightly oily conditions.
This guide covers the product's construction, sizing,
mechanical standards, material and comfort profile,
applications, inspection, storage, and use limitations.
Manufacturer specifications are separated from practical
selection guidance.
Operations takeaway:
Treat the 11-801 as a breathable handling glove with
A1 cut resistance, not high-cut protection.
Dirt masking, skin-assessment credentials, and an
antistatic designation do not independently establish
longer safe service life, cleanroom suitability, or
universal ESD approval.
Core product data
- Manufacturer: Ansell
- Product family / model: HyFlex® 11-801
- Product type: Breathable multi-purpose industrial handling glove
- Protection profile: Low-level cut resistance, abrasion resistance, general mechanical puncture resistance, grip, and dexterity
- Featured fit technology: ZONZ™ Comfort Fit Technology
- Additional designation: DMF-free
- Primary industries: Automotive and metal fabrication
- Manufacturer-listed uses: Picking and fastening components; adjusting systems and screwing; loading and unloading; receiving goods; shipping, transport, delivery; locksmith work
Construction and materials
- Construction: Knitted
- Gauge: 15
- Liner: Grey nylon
- Coating: Black foam nitrile
- Coverage: Palm coated
- Cuff: Knitwrist
- Latex-free: Yes, as listed by Ansell
- Silicone-free: Yes, as listed by Ansell
- Antistatic: Yes, as listed by Ansell
- Washing temperature: 40°C / 104°F
Construction distinction:
The coated palm supplies the contact surface, while the
knitted body supports fit and movement. Palm coating is
not full hand encapsulation. The intentionally uncoated
back is part of the design, not evidence of coating failure.
Dimensions, sizing, and packaging
- Length: 214–280 mm; manufacturer-listed 8.42–11.02 inches
- Numeric sizes: 6, 7, 8, 9, 10, 11
- Manufacturer packaging: 12 pairs per bag; 12 bags per carton
- Total case quantity: 144 pairs
- SOSCleanroom configuration: Case of the selected numeric size
Receiving check:
Confirm model 11-801, numeric size, quantity, package condition,
and product markings. Order by the numeric size rather than
assuming generic letter-size conversions are identical
across every glove model.
Ansell glove sizing guide
Use the printable Ansell hand-placement chart as a starting
reference, then verify fit in the actual 11-801 glove.
A resized screen image is not a measuring template.
Open the printable Ansell glove sizing chart
- Print at the intended scale without automatic page fitting or resizing.
- Place the right hand palm down with fingers together, following the chart's blue index-finger alignment line and thumb-crotch reference.
- Read the colored line visible at the outside edge of the hand, then check movement, fingertip fit, and cuff security in a sample glove.
| 11-801 numeric size |
Reference printed on the chart |
| 6 | 15.2 cm |
| 7 | 17.8 cm |
| 8 | 20.3 cm |
| 9 | 22.9 cm |
| 10 | 25.4 cm |
| 11 | 27.9 cm |
Fit note:
These references are not finished glove dimensions or
measurements of the displayed page. The general chart
includes size 12, but the 11-801 is listed in sizes
6–11. Confirm fit in the specific glove before
standardizing a size.
Performance standards and compliance
| Standard or designation |
Published result |
| ANSI/ISEA 105-2024 cut resistance | A1 |
| ANSI/ISEA 105-2024 abrasion resistance | Level 3 |
| ANSI/ISEA 105-2024 puncture resistance | Level 2 |
| EN 388:2016+A1:2018 | 3131A |
| EN ISO 13997 cut classification | A |
| General glove requirements | EN ISO 21420:2020 |
| CE PPE category | Category II |
| Dermatological assessment | Dermatest™ approval listed by Ansell |
| OEKO-TEX® | Manufacturer-listed reference 1408033 |
| REACH | Compliant, as listed by Ansell |
Declaration scope:
The reviewed EU declaration identifies 3131A,
EN 388:2016+A1:2018, and EN ISO 21420:2020 for production
from September 7, 2023. Earlier production is documented
separately. Match the declaration to the supplied gloves;
do not transfer another model's standards revision.
EN 388 code breakdown: 3131A
| Position |
Rating |
Performance area |
| First digit | 3 | Abrasion resistance |
| Second digit | 1 | Circular-blade cut resistance |
| Third digit | 3 | Tear resistance |
| Fourth digit | 1 | Mechanical puncture resistance |
| Letter | A | ISO 13997 cut classification |
Test scope:
These are separate results, not an overall safety score.
Palm test results do not automatically establish equivalent
protection at differently constructed backs or cuffs.
No impact-protection P appears in the marking.
ANSI rating interpretation
| ANSI rating |
Practical interpretation |
| Cut A1 |
Low-level cut resistance for qualifying light-duty handling, not severe sharp-edge exposure. |
| Abrasion 3 |
Standardized abrasion performance; not a guaranteed replacement interval. |
| Puncture 2 |
General mechanical puncture classification, not hypodermic-needle protection. |
Selection principle:
Assess cutting, abrasion, puncture, and grip separately.
One favorable rating does not compensate for a different
hazard that the glove does not adequately address.
Material, grip, and comfort performance profile
| Component |
Technical role |
Handling consideration |
| 15-gauge nylon liner |
Flexible knitted glove body |
Supports movement and tactile handling |
| Foam nitrile palm |
Grip and abrasion-contact layer |
Dry and slightly oily handling; not a liquid barrier |
| ZONZ™ Comfort Fit |
Comfort-focused fit design |
Intended to relieve tension and improve usability |
| Grey liner |
Dirt-masking appearance |
Does not reveal all contamination or establish remaining protection |
| Dermatest™ / OEKO-TEX® references |
Manufacturer-listed assessment credentials |
Not allergy-free, sterile, or cleanroom certifications |
Breathability comparison:
Ansell reports 30% greater breathability than comparable
gloves. The reviewed product sheet does not identify
comparator models, test method, or test date.
Dirt-masking limitation:
The liner color changes how readily soil is seen.
It does not remove contamination, repair worn coating,
or extend the glove's tested protection.
Antistatic, silicone-free, and skin-assessment qualifications
Ansell lists antistatic, latex-free, and silicone-free as
Yes and identifies a DMF-free designation. Its literature
also describes Dermatest™ approval and an
impurity-removing manufacturing wash.
The reviewed model-specific product sheet and EU declaration
do not establish EN 16350 certification or numerical
electrical-resistance data. Obtain the required evidence
before approving this glove for electronics ESD control
or a flammable or explosive atmosphere.
Antistatic does not mean electrically insulating.
Silicone-free does not mean contamination-free.
Latex-free and dermatological assessment do not guarantee
freedom from every material sensitivity. Touchscreen
compatibility is not established in the reviewed
11-801 documentation.
Recommended use environments
| Application area |
Site-selection consideration |
| Picking and fastening components |
Confirm fingertip control, part condition, and sufficient cut protection. |
| Adjusting systems and screwing |
Assess fit, tool control, and equipment hazards. |
| Loading and unloading vehicles |
Check package edges, puncture exposure, grip, and abrasion. |
| Handling incoming goods |
Inspect for contamination and unexpected sharp objects. |
| Shipping, transport, and delivery |
Evaluate repeated handling and actual surface conditions. |
The task categories follow the supplied content and
manufacturer literature. The assessment considerations
are practical selection guidance, not additional
product certifications.
Suitable for
- Picking and fastening components
- Adjusting systems and screw-fastening tasks
- Loading and unloading trucks and vehicles
- Receiving, shipping, transport, and delivery
- Qualifying locksmith and automotive support work
- Metal fabrication support with limited cut exposure
- Warehousing and logistics
- Dry or slightly oily light-duty handling after task approval
- Applications requiring the listed material attributes, subject to the site's complete qualification requirements
Not recommended for
- Chemical immersion or tasks requiring chemical breakthrough protection
- Liquidproof barrier protection
- High heat, open flame, or molten-metal exposure
- Moving blades, powered cutting tools, or entanglement hazards
- Needles, hypodermic sharps, or fine-point puncture hazards
- Electrical insulation or ESD-controlled use without appropriate qualification
- Tasks requiring higher cut, impact, or heavier mechanical protection
- Heavy oil saturation requiring separately qualified glove coverage
- Sterile, food-contact, or cleanroom applications without the required model-specific documentation
Selection guidance
| Consider 11-801 when you need |
Choose another qualified glove when you need |
| Breathable foam nitrile handling |
Oil-repellent, fully coated, or chemically protective construction |
| A1 / EN ISO A cut resistance |
Higher cut protection for more severe edges or contact forces |
| Comfortable routine production or logistics handling |
Thermal, impact, electrical, sterile, or cleanroom-specific protection |
| Manufacturer-listed silicone-free and latex-free attributes |
Additional validated cleanliness, resistance, or process-performance data |
Selection priority:
Protection requirements come first. Comfort, dexterity,
and appearance help determine usability but do not
compensate for an inadequate hazard rating.
Inspection before use
- Check the palm coating for cuts, punctures, cracking, peeling, worn-through areas, and reduced grip.
- Inspect fingertips, the thumb crotch, and other high-contact zones.
- Check the nylon liner for holes, tears, damaged yarns, and contamination.
- Confirm that the knitwrist cuff remains secure and intact.
- Do not use gloves contaminated with unknown chemicals or substances incompatible with the task.
- Replace gloves when integrity, fit, grip, tactility, or process suitability is compromised.
Inspection limitation:
Appearance cannot quantify remaining cut resistance.
Dirt masking is not proof that the glove is clean or
still meets its original laboratory performance.
Storage and handling notes
- Store dry, at room temperature, in the original packaging.
- Protect from sunlight, ozone, sharp objects, excessive heat, and contamination.
- Keep gloves away from incompatible chemicals.
- Check that the interior is clean before donning.
- Follow site inspection, reuse, laundering, and disposal procedures.
Washing guidance:
Ansell lists 40°C / 104°F. Follow the supplied care
markings for the permitted process and number of cycles.
This temperature entry alone does not establish three-cycle
or unlimited reuse. Reassess gloves already worn in service
after cleaning.
Cleanroom and controlled-environment note
HyFlex 11-801 is an industrial light-duty handling glove.
The reviewed manufacturer documents do not establish
sterile packaging, cleanroom processing, or quantitative
particle and extractables limits.
Qualify the glove against the site's particulate, fiber,
residue, packaging, laundering, coating, silicone,
static-control, and gowning requirements. Use separately
qualified cleanroom gloves where documented low-particle
or sterile hand protection is required.
Technical FAQs
What is the primary advantage of HyFlex 11-801?
Breathable light-duty handling comfort, foam nitrile
palm grip, ZONZ™ fit, and a dirt-masking grey liner.
What is its cut rating?
ANSI A1 and EN ISO A within the EN 388 3131A marking.
It is not a high-cut-protection model.
What are the coating and liner materials?
Black foam nitrile over the palm and a grey
15-gauge knitted nylon liner.
Is it silicone-free and latex-free?
Yes, according to Ansell. These attributes do not
establish universal allergy-free or contamination-free use.
Is it antistatic?
Ansell lists antistatic as Yes. Application-specific
approval is still required because the reviewed
model-specific documents do not establish EN 16350
certification or numerical resistance data.
Does the dark liner make the glove safe to use longer?
No. Dirt masking changes appearance. Replacement
depends on condition, contamination, grip, fit,
and the approved task.
Is touchscreen compatibility confirmed?
It is not established in the reviewed 11-801
manufacturer documentation.
What comes in a case?
144 pairs of the selected size, with manufacturer
pack counts of 12 pairs per bag and 12 bags per carton.
Critical use limitations
HyFlex 11-801 is intended for light-duty mechanical handling,
not chemical, thermal, electrical, impact, needle, or
high-cut protection. Select PPE using the actual edge,
contact force, abrasion, puncture, fluid, grip,
contamination, static-control, and fit requirements.
General task descriptions do not replace the employer's
documented hazard assessment.
Manufacturer documentation and technical references
Source basis:
Specifications follow Ansell's model-specific documents
and the supplied SOSCleanroom content. Qualification
checkpoints are practical selection guidance, not
additional certifications. Current product markings
and manufacturer instructions govern use.
If you have any questions please email us at Sales@SOSsupply.com
or give us a call at (214) 340-8574.
For additional product guidance, use the SOSCleanroom AI ChatBot
or contact our team for manufacturer documentation assistance.
Technical insight:
HyFlex 11-801 prioritizes breathable comfort, tactile handling,
and light-duty mechanical protection. Select another qualified
glove when the task requires protection outside that scope.
Last updated: October 21, 2026
© 2026 SOSCleanroom. All rights reserved.