WHEATON® LAB FILE® 224882 Sample Vials - 4 mL Clear Borosilicate Glass, 13-425 Cap with 14B Rubber Liner, 144/Case

The WHEATON® LAB FILE® 224882 from DWK Life Sciences is a 4 mL clear borosilicate glass laboratory sample vial supplied with an attached 13-425 black phenolic screw cap featuring a 14B rubber liner. Designed for general laboratory sampling and sample storage, this standard-height vial combines a compact glass container with a closure configuration intended primarily for compatible aqueous samples.

Each vial measures 15 mm in diameter and 48 mm in height. The clear glass is manufactured from Type I borosilicate tubing, identified in the manufacturer specifications as Clear Type 1A Borosilicate. LAB FILE® partitioned-tray packaging helps organize empty vials and stored samples, while the caps-attached presentation supports cleanliness during handling.

Key advantage: Clear Type I borosilicate sample vials with preattached 13-425 solid-top phenolic caps, 14B rubber liners for appropriate aqueous applications, and organized LAB FILE® packaging. 144 vials per case.

Specifications:
  • Manufacturer: DWK Life Sciences
  • Brand: WHEATON®
  • Product line: LAB FILE®
  • Manufacturer part number: 224882
  • Product type: Standard-height glass sample vial with attached screw cap
  • Nominal capacity: 4 mL
  • Manufacturer dram-size designation: 1 dram
  • Vial material: Clear borosilicate glass tubing
  • Manufacturer glass designation: Clear Type 1A Borosilicate
  • Product-family glass classification: Type I borosilicate
  • Vial color: Clear
  • Vial diameter: 15 mm
  • Vial height: 48 mm
  • Vial style: Standard height, not Shorty Vials®
  • Thread finish: 13-425
  • Closure material: Black phenolic
  • Cap style: Solid-top screw cap
  • Closure liner: 14B rubber
  • Cap configuration: Caps supplied attached to the vials
  • Primary liner application: Compatible aqueous samples
  • Packaging: LAB FILE® partitioned-tray presentation
  • Case quantity: 144 vials with caps
  • Ordering unit: Case
  • Autoclavable: Yes; manufacturer identifies both vials and caps as autoclavable
  • Compatible WHEATON vial rack reference: 868804
  • Compatible WHEATON M-T File® reference: 228780
  • Country of origin: United States, according to manufacturer item-setup data

Closure distinction: This configuration includes a 14B rubber-lined, solid-top cap. It is not the PTFE/14B rubber-lined version. Organic solvents and aggressive formulations may require a different liner and a separately qualified closure system.

Capacity distinction: The 4 mL / 1 dram designation identifies the manufacturer's nominal vial size, not a calibrated measurement or recommended maximum working fill.

Where LAB FILE 224882 Fits in Laboratory Workflows

LAB FILE® vials are designed for general laboratory sample collection, organization, and storage. The compact 4 mL format supports applications requiring smaller sample containers, while the clear glass allows visual examination of the contents when appropriate to the laboratory method.

The included 14B rubber-lined cap makes this configuration a practical starting point for compatible aqueous samples. The selected liner must still be evaluated against the actual formulation, storage duration, temperature, and analytical requirements.

Important: A rubber-lined screw cap is not automatically compatible with every solvent, reagent, or sample. If your process involves organic solvents, contact SOSCleanroom about an appropriate PTFE-faced liner configuration.

About the Manufacturer:

WHEATON®, a DWK Life Sciences brand, manufactures laboratory containers, sample vials, glassware, and closure systems. The LAB FILE® range includes multiple capacities, cap configurations, liner materials, and storage formats to support laboratory sample-management workflows. SOSCleanroom provides assistance with product selection, case quantities, and technical documentation.

WHEATON LAB FILE 224882 Features:
  • 4 mL clear borosilicate glass sample vial
  • Manufacturer-designated Type 1A borosilicate construction
  • Standard-height vial measuring 15 × 48 mm
  • 13-425 external screw-thread finish
  • Black phenolic solid-top cap supplied attached
  • 14B rubber cap liner for appropriate aqueous samples
  • LAB FILE® partitioned-tray packaging for organization
  • Manufacturer-listed autoclavability of vials and caps
  • 144 vials with caps per case
WHEATON LAB FILE 224882 Benefits:
Design Feature Practical Benefit
Clear borosilicate glass Provides a glass sample container with useful chemical resistance for qualified laboratory applications
Attached 13-425 cap Keeps the intended closure with the vial during supply and handling
14B rubber liner Lined closure configuration intended for compatible aqueous samples
Compact 15 × 48 mm body Supports organized small-sample storage and equipment selection
LAB FILE® partitioned trays Helps organize sample vials and makes inventory management easier
144-count case Consistent ordering quantity for laboratory purchasing and replenishment
Recommended Applications
  • General laboratory sample collection
  • Storage of compatible aqueous samples
  • Small-volume sample archiving and identification
  • Laboratory testing and sample preparation workflows
  • Sample organization using LAB FILE® trays
  • Quality-control sample retention where the glass and liner meet method requirements
  • Laboratory workflows using compatible 13-425 sample-vial closures

Application suitability depends on the actual contents, required cleanliness, analytical method, and storage conditions. These application examples are not universal sample-stability certifications.

Best Practices for Filling, Storage, and Handling
  • Verify the sample: Confirm compatibility with clear borosilicate glass and the 14B rubber liner.
  • Inspect the vial: Check the glass for cracks, chips, and contamination before filling.
  • Inspect the closure: Confirm that the rubber liner is present, intact, and properly positioned.
  • Protect the rim: Prevent sample residue from interfering with the cap and sealing surface.
  • Control fill volume: Establish an approved working fill and headspace for the actual method.
  • Use the correct cap: Maintain the intended 13-425 closure configuration.
  • Label samples: Apply the laboratory's identification, traceability, and storage requirements.
  • Qualify processing: Follow an approved autoclaving procedure when that capability is required.

These are practical application checkpoints, not a universal manufacturer-validated filling, cleaning, or sterilization procedure.

Selection Notes
  • 14B rubber vs. PTFE/14B rubber: This SKU has plain 14B rubber. Do not assign PTFE-faced chemical-resistance performance to it.
  • Standard vs. Shorty: The 224882 measures 48 mm in height and is the standard vial configuration.
  • Solid-top cap: The supplied cap is not described as an open-top cap or a pierceable septum closure.
  • Caps attached: The caps are supplied on the vials; the designation does not establish a permanently tethered or hinged cap.
  • Autoclavable vs. sterile: The manufacturer identifies the vials and caps as autoclavable, but this does not mean the supplied case is sterile.
  • Nominal volume: The 4 mL capacity does not establish volumetric Class A accuracy or a calibrated measurement tolerance.
Important Use Limitations

WHEATON 224882 is designed for qualified laboratory sample applications. Its plain 14B rubber liner should not be assumed compatible with organic solvents, aggressive chemicals, or all analytical methods. A PTFE-faced alternative may be more appropriate for certain organic samples.

The reviewed manufacturer data do not establish a quantified leakproof rating, pressure rating, vacuum rating, centrifuge rating, or universal low-temperature storage qualification.

Although the manufacturer lists the vials and caps as autoclavable, the supplied product should not be represented as presterilized, depyrogenated, or qualified for every sterilization cycle. The appropriate procedure must be validated for the complete configuration and intended use.

Product Selection and Technical Support

SOSCleanroom can help customers identify the correct WHEATON sample-vial configuration, cap liner, case quantity, vial racks, and storage accessories. For applications involving organic solvents, specialized sealing requirements, or documented sample compatibility, our team can assist with manufacturer specification requests.

For pricing, availability, product selection, or supporting technical documentation, contact Sales@SOSsupply.com or call (214) 340-8574.

Technical insight: The closure liner is as important as the glass vial. For aqueous samples, 14B rubber may be appropriate; for organic solvents and more demanding chemical compatibility requirements, evaluate an approved alternative before ordering.

Product page updated: October 22, 2026

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom). All rights reserved.

The Technical Vault By SOSCleanroom
4 mL Glass Vial Type I Borosilicate 13-425 Screw Cap 14B Rubber Liner Caps Attached 144 per Case

WHEATON 224882: Understanding the Glass Vial, Screw Cap, and Rubber Liner

The WHEATON® LAB FILE® 224882 is a 4 mL clear borosilicate glass sample vial supplied with an attached 13-425 black phenolic screw cap featuring a 14B rubber liner. The manufacturer positions the 14B rubber-lined closure primarily for compatible aqueous samples.

The vial belongs to WHEATON's standard-height LAB FILE® sample-vial family. Partitioned trays support sample organization, and the preattached cap presentation helps keep the intended closure with the vial.

For successful selection, evaluate the glass, phenolic cap, and rubber liner together. Glass compatibility alone does not establish suitability of the complete assembled container.

Technical takeaway: WHEATON 224882 is a clear glass vial with a 14B rubber-lined solid-top cap. It is not the PTFE-faced closure configuration. Select the liner according to sample chemistry, exposure duration, and analytical requirements.


Core Product Specifications
Specification WHEATON 224882
Manufacturer DWK Life Sciences
Brand / family WHEATON® LAB FILE®
Catalog number 224882
Capacity 4 mL nominal; 1 dram size designation
Vial material Clear borosilicate glass tubing
Manufacturer glass designation Clear Type 1A Borosilicate
Glass family description Type I borosilicate
Vial color Clear
Diameter 15 mm
Height 48 mm
Thread finish 13-425
Cap material Black phenolic
Cap style Solid top
Cap liner 14B rubber
Caps supplied Yes, attached to vials
Packaging LAB FILE® partitioned trays
Case quantity 144 vials with caps
Autoclavable Yes, according to manufacturer family specifications
Country of origin United States, per manufacturer item data

Important: Nominal capacity does not establish calibrated volumetric accuracy, usable fill volume, pressure resistance, or sample compatibility. Those properties must be evaluated according to the intended application.


Clear Type I Borosilicate Glass Construction

WHEATON 224882 is manufactured from clear borosilicate glass tubing. The manufacturer identifies its glass as Clear Type 1A Borosilicate and describes the LAB FILE® clear sample-vial family as Type I borosilicate glass.

Borosilicate glass is used in laboratory applications where chemical resistance and thermal performance are important. However, exact suitability depends on the glass composition and the intended chemical and processing conditions.

Standards distinction: The manufacturer's glass-material designation should not be confused with the Class A accuracy classification used for calibrated volumetric glassware. The reviewed records do not establish volumetric Class A accuracy for these vials.


Understanding the 13-425 Screw Closure

The 13-425 designation identifies the vial's screw-thread finish. The manufacturer-supplied closure is a black phenolic solid-top cap containing a 14B rubber liner.

A solid-top screw cap is not the same as an open-top cap fitted with a pierceable septum. Do not assume syringe access, repeated puncture performance, or autosampler compatibility based solely on the cap's rubber liner.

Replacement caps are available within the manufacturer's broader vial program, but substitute closures must be checked for finish, liner material, and sealing suitability before use.


14B Rubber vs. PTFE/14B Rubber: Why Liner Selection Matters

The LAB FILE® family includes different cap-liner constructions for different sample chemistries. The correct liner is a critical part of sample compatibility and container-closure performance.

Closure Configuration Manufacturer Positioning Selection Note
14B Rubber Aqueous samples Supplied with WHEATON 224882; confirm compatibility with the exact aqueous formulation.
PTFE / 14B Rubber Organic samples and improved chemical compatibility A different closure configuration; confirm suitability for the specific solvent or mixture.

Do not assume equivalence: The plain 14B rubber liner on SKU 224882 does not provide a documented PTFE contact surface. Applications involving organic solvents, aggressive chemicals, or demanding analytical requirements should be evaluated separately.

Related manufacturer configuration: WHEATON W224582 uses a clear 4 mL vial with PTFE/14B rubber-lined cap. Contact SOSCleanroom to confirm its availability and suitability for the application.


Caps Attached vs. Caps Supplied Separately

DWK describes the LAB FILE® configuration as vials with caps attached. This presentation helps maintain cleanliness by keeping the intended closure with the vial during supply and handling.

The attached designation does not establish that the cap is permanently tethered, hinged, or incapable of removal. It should also not be interpreted as a sterile or hermetically sealed supply state.

Other WHEATON vial families supply caps separately. Those configurations may have different packaging, pricing, and case quantities. Select the catalog number that matches the laboratory's handling and receiving requirements.


LAB FILE Partitioned Trays and Sample Organization

LAB FILE® uses partitioned trays that help organize laboratory sample vials. This packaging provides a convenient way to inventory empty containers or organize stored samples.

Catalog 224882 contains 144 vials with caps per case. An independent manufacturer-listed numeric inner-pack count has not been established in the reviewed item specifications.

Tray packaging should not be confused with a sterile barrier or an ISO cleanroom processing certification. Evaluate the actual supplied packaging before controlled-area introduction.


Rack and Storage Accessory Compatibility

The manufacturer's catalog-specific specifications identify the following accessory references:

Accessory Reference Manufacturer-Listed Fit
868804 Compatible vial rack
228780 Compatible M-T File® storage system

These are accessory references, not accessories identified as included in the 224882 vial case. Contact SOSCleanroom to confirm available storage options and the desired configuration.


Autoclavability, Sterility, and Processing Considerations

DWK identifies the LAB FILE® sample vials and caps as autoclavable. This is a manufacturer-described processing capability.

It does not independently establish the suitability of every complete, tightly closed, filled vial assembly for the same autoclave conditions. The effects of processing on the rubber liner and subsequent seal performance must be evaluated for the actual procedure.

Important distinction: Autoclavable does not mean supplied sterile. No product-specific sterility assurance level, depyrogenation claim, endotoxin limit, or validated cycle is established in the reviewed manufacturer records.

The facility should qualify cleaning, loading, closure conditions, processing, cooling, and any required post-processing inspection before routine use.


Sample Compatibility and Analytical Considerations

Clear borosilicate glass offers useful laboratory chemical resistance, but compatibility and sample integrity depend on the actual formulation, concentration, storage temperature, and exposure duration.

The cap and liner should be assessed alongside the glass. Depending on the method, qualification may include extractables, sample adsorption, evaporation, contamination, and analytical recovery.

  • Glass contact: Evaluate the sample against clear borosilicate glass.
  • Rubber liner contact: Confirm suitability for the actual aqueous formulation.
  • Storage period: Establish acceptable sample stability for the required duration.
  • Volatile contents: Confirm evaporation and seal-performance requirements.
  • Analytical sensitivity: Evaluate potential extractables or sample interactions when method limits require it.

These are qualification considerations, not documented performance values for every sample or analytical method.


Standard Vials vs. Other LAB FILE Configurations
Manufacturer SKU Configuration Key Difference
224882 4 mL clear standard vial with attached cap 14B rubber liner; this product
W224582 4 mL clear standard vial with attached cap PTFE/14B rubber liner for different chemical-compatibility requirements
225012 4 mL clear standard vial with writing patch and cap Writing patch for identification

Related configurations are not automatic replacements for an approved sample-vial method. Verify closure materials, dimensions, case quantities, and required labeling features.

Contact SOSCleanroom for assistance obtaining pricing and availability for another WHEATON configuration.


Receiving and Inspection Checklist
  • Verify product identity: Confirm WHEATON catalog number 224882, 4 mL clear vial, and 144-count case.
  • Inspect the glass: Check for chips, cracks, contamination, or damaged threads.
  • Verify closure: Confirm that the black phenolic screw cap and 14B rubber liner are present.
  • Inspect liner condition: Check for visible damage, displacement, or contamination.
  • Inspect packaging: Review the condition of the LAB FILE® trays and investigate broken or damaged vials.
  • Verify processing status: Follow the facility's requirements for cleaning, preparation, and sterilization.
  • Maintain sample identification: Use the required labeling and tracking procedures.

Storage and Handling Notes

The manufacturer item-setup information lists room-temperature conditions for shipping and storage of the supplied empty vials.

Protect the glass from impact and maintain the laboratory's required cleanliness and identification controls. Keep the closure and liner free from damage or contamination before use.

The reviewed manufacturer documents do not establish a universal shelf life for filled samples, an unlimited closure-reuse life, or a validated low-temperature storage range for every sample-and-liner combination.


Cleanroom and Controlled-Environment Considerations

Although LAB FILE® packaging is intended to help maintain sample-vial cleanliness, the reviewed product records do not establish an ISO cleanroom classification, supplied sterile designation, or quantitative particle-release specification.

For controlled-environment applications, qualify the glass vial, cap liner, packaging, preparation process, and material-transfer procedure according to the facility's contamination control requirements.


Technical FAQs

Does WHEATON 224882 include the caps?

Yes. Black phenolic 13-425 screw caps with 14B rubber liners are supplied attached to the vials.

What is the actual vial capacity?

The manufacturer's nominal capacity is 4 mL, also designated 1 dram. This does not establish a calibrated measurement tolerance.

Is the cap suitable for organic solvents?

The included plain 14B rubber liner is positioned for aqueous samples. A separate PTFE/14B configuration is offered for applications requiring improved chemical compatibility.

Can the cap be punctured with a syringe?

The supplied closure is described as solid top. Syringe access or repeated-puncture performance is not established by this specification.

Are the vials autoclavable?

Yes. DWK identifies LAB FILE® vials and caps as autoclavable. The complete procedure must be qualified for the intended use.

Are the vials supplied sterile?

The reviewed manufacturer records do not establish a supplied-sterile designation. Autoclavability is not evidence of supplied sterility.

What are the dimensions?

15 mm diameter and 48 mm height, with a 13-425 screw-thread finish.

Which WHEATON vial rack fits?

The manufacturer lists vial rack 868804 and M-T File® 228780. These accessories are not identified as included with the vial case.

How many vials are in a case?

144 vials with caps per case.


Technical Documentation and Product Support

SOSCleanroom can assist with available manufacturer technical documentation and product-selection information for WHEATON LAB FILE 224882.

  • Catalog-specific specifications and case quantities
  • Glass material and vial dimensions
  • 13-425 phenolic cap specifications
  • 14B rubber and alternative liner configurations
  • Autoclavability and application considerations
  • Compatible racks and storage accessories
  • Additional manufacturer documentation when available and required for qualification

Need help selecting a sample vial? SOSCleanroom can assist with comparing WHEATON vial sizes, cap materials, liner configurations, and case quantities.

Email: Sales@SOSsupply.com
Phone: (214) 340-8574


For product specifications, ordering, availability, or application assistance, contact SOSCleanroom at Sales@SOSsupply.com or (214) 340-8574. Technical insight: Always qualify the glass vial, phenolic cap, and rubber liner together. Sample chemistry and closure selection directly affect the suitability of the complete container. Last updated: October 22, 2026 © 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom). All rights reserved.