WHEATON 986701
20 mL
White HDPE
22-400
White PP Cap
Metal Foil/Pulp
27 x 61 mm Capped
Non-Sterile
Caps Attached
500/Case
WHEATON 986701: Exact-SKU Technical Overview
WHEATON® 986701 is a 20 mL white high-density polyethylene (HDPE) liquid scintillation vial supplied with an attached white polypropylene 22-400 screw cap and metal foil/pulp liner. The manufacturer specifies a 27 mm outside diameter, 57 mm height without cap, and 61 mm overall capped height.
DWK identifies the exact product as non-sterile, with no marking spot, and supplies it in cases of 500 vial-and-cap units. The current 986701 product record does not publish an autoclavability field.
The primary selection difference from WHEATON 986700 is the metal foil/pulp liner rather than foamed polyethylene. The two products otherwise share the same named HDPE vial material, 22-400 polypropylene cap, published dimensions, and attached-cap presentation.
DWK's general Closure Liner Guide describes metal foil/pulp as aluminum foil bonded to pulp board. It reports good barrier characteristics and general resistance to hydrocarbons, oils, ketones, and alcohols, but identifies acids and alkalis as unsuitable for this liner type.
The complete 986701 container includes three material components: white HDPE vial, white polypropylene cap, and metal foil/pulp liner. Compatibility of the liner alone does not establish compatibility of the complete assembly with a particular liquid scintillation cocktail or laboratory sample.
Operations takeaway: Order 986701 for a 20 mL white HDPE vial, 27 x 57 mm without cap / 27 x 61 mm capped, attached white PP 22-400 cap, metal foil/pulp liner, 500 per case. The product is non-sterile. The exact SKU has no published autoclave field, but DWK generally identifies HDPE as not autoclavable.
Exact-SKU Specifications for Purchasing, Receiving, and SOPs
- Manufacturer: DWK Life Sciences
- Brand: WHEATON®
- Catalog number: 986701
- Product: HDPE liquid scintillation vial with attached screw cap
- Nominal capacity: 20 mL
- Vial material: High-density polyethylene (HDPE)
- Vial color: White
- Outside diameter: 27 mm
- Height without cap: 57 mm
- Overall height including cap: 61 mm
- Thread finish: 22-400
- Cap included: Yes, attached
- Cap material: Polypropylene (PP)
- Cap color: White
- Liner material: Metal foil / pulp
- General liner construction: Aluminum foil bonded to pulp board
- General liner barrier properties: Good, per DWK technical guidance
- General liner chemical resistance: Hydrocarbons, oils, ketones, and alcohols
- General liner chemical limitation: Not good for acids or alkalis
- Marking spot: No
- Sterility: Non-sterile
- Exact-SKU autoclavability: Not listed on current product page
- General HDPE autoclavability: DWK technical guide indicates no
- Nominal capacity class: 20 mL
- Case quantity: 500
- Cap presentation: Attached to vials
- Numerical optical transmission: Not specified for this exact white HDPE SKU
- Numerical background-count rating: Not established
- Certified leakproof or vapor-tight rating: Not established
- Specific cap-tightening torque: Not established
- Calibrated fill tolerance: Not established
- Counting instrument compatibility: Requires verification
- Inner packaging subdivision: Not confirmed from exact-SKU product record
- Shipping weight and carton dimensions: Not confirmed
- Country of origin: Not verified
Specification control: The 20 mL capacity is nominal. The 61 mm dimension includes the attached cap, and the 22-400 thread finish must match the closure. Neither the thread designation nor the foil liner independently establishes a guaranteed leakproof seal.
Metal Foil/Pulp Liner: Construction and Technical Properties
DWK identifies the liner supplied with WHEATON 986701 as metal foil/pulp. Its general Closure Liner Guide describes pulp/metal foil as aluminum foil bonded to pulp board.
The aluminum foil layer and pulp-board backing form a composite liner distinct from polyethylene foam, polyethylene discs, polyethylene cones, and metal foil/cork. These liner materials have different manufacturer descriptions and should not be substituted solely because they are used with 22-400 screw caps.
DWK describes foil/pulp as having good barrier properties and general resistance to hydrocarbons, oils, ketones, and alcohols. These characteristics may be relevant to methods involving certain compatible organic solvent formulations.
However, the same technical guide specifically notes that this liner type is not good for acids or alkalis. Some liquid scintillation samples contain acidic or alkaline reagents, buffers, or mixed chemical systems, making application-specific compatibility review necessary.
| Liner attribute |
DWK general material guidance |
| Exact liner type |
Metal Foil / Pulp |
| Construction |
Aluminum foil bonded to pulp board |
| Barrier characteristics |
Good general barrier properties |
| Hydrocarbons |
Good general resistance |
| Oils |
Good general resistance |
| Ketones |
Good general resistance |
| Alcohols |
Good general resistance |
| Acids |
Not good; avoid assuming compatibility |
| Alkalis |
Not good; avoid assuming compatibility |
| PTFE facing |
Not specified |
| Certified leak rate |
Not established for finished 986701 assembly |
The properties above are general material descriptions. They are not numerical chemical-exposure test results for the assembled 986701 vial. Real performance can vary according to the solvent mixture, concentration, temperature, exposure time, cap condition, and closure handling.
Important liner limitation: Good resistance of foil/pulp to certain organic chemicals does not establish universal compatibility of the HDPE vial, polypropylene cap, and foil/pulp liner. Review the full chemical formulation and test the complete container-closure system when required.
986701 vs. 986700: Foil/Pulp Compared with Foamed Polyethylene
WHEATON 986701 and 986700 share a white 20 mL HDPE vial body and white polypropylene 22-400 attached cap. Their published dimensions are the same. The difference is the manufacturer-specified liner construction.
| Characteristic |
986701: Foil/Pulp |
986700: Foamed PE |
| Liner construction |
Aluminum foil on pulp board |
Foam core with solid LDPE outer layers |
| Hydrocarbon solvents |
Good general resistance |
Poor general resistance |
| Acids / alkalis |
Not good |
Broad general resistance described; verify exact conditions |
| Vial material |
White HDPE |
White HDPE |
| Cap material |
White polypropylene |
White polypropylene |
| Thread finish |
22-400 |
22-400 |
| Capped dimensions |
27 x 61 mm |
27 x 61 mm |
| Case quantity |
500 |
500 |
Selection principle: Foil/pulp and foamed PE have different chemical-resistance profiles. Neither should be represented as universally superior. The correct selection depends on the complete sample formulation, analytical requirements, and tested closure performance.
Foil/Pulp vs. Foil/Cork: 986701 Compared with 986702
WHEATON 986701 and 986702 both use a white HDPE 20 mL vial with a 22-400 threaded closure. However, 986701 includes a white polypropylene cap with metal foil/pulp liner, while 986702 uses a white urea cap with metal foil/cork liner.
The two closures differ in both cap-body material and liner backing material. DWK's Closure Liner Guide documents chemical-resistance characteristics for pulp/metal foil, but the same values should not be transferred to metal foil/cork without product-specific evidence.
- 986701: White PP cap with metal foil/pulp liner.
- 986702: White urea cap with metal foil/cork liner.
- Shared vial material: White HDPE.
- Shared thread: 22-400.
- Shared nominal dimensions: 27 x 61 mm capped.
- Important limitation: Different cap and liner materials require independent compatibility evaluation.
High-Density Polyethylene: Material Properties and Limitations
HDPE is a polyethylene polymer used in a variety of laboratory containers. WHEATON 986701 uses a white HDPE vial body, making it different from the transparent glass and PET configurations offered within the WHEATON scintillation-vial family.
DWK's Typical Properties of Plastics guide lists general physical, thermal, and sterilization properties for HDPE and other polymer materials. These reference values can guide preliminary material selection but do not establish a qualified operating-temperature range, optical response, chemical compatibility, or sterilization cycle for the exact 986701 vial.
General HDPE material characteristics must also be considered alongside the other parts of the assembly. The white polypropylene cap may have different chemical and thermal properties, and the foil/pulp liner has a distinct chemical-resistance profile.
| Material component |
Selection consideration |
| White HDPE vial |
Polymer chemistry, temperature, sample interaction, optical behavior |
| White polypropylene cap |
Chemical exposure, mechanical engagement, cap integrity |
| Metal foil/pulp liner |
Solvent resistance, acid/alkali limitations, seal condition |
| Complete assembly |
Method compatibility, seal performance, sample integrity |
Material qualification warning: Do not use an HDPE-only chemical-resistance chart to approve the complete product. The polypropylene cap and foil/pulp liner may have different limitations from the vial body.
HDPE vs. PET vs. Borosilicate Glass Scintillation Vials
WHEATON offers 20 mL liquid scintillation vials manufactured from HDPE, PET, and borosilicate glass. Although these configurations can share a 22-400 thread and similar overall height, their material properties and dimensions are not identical.
| Feature |
986701 |
986731 |
986541 |
| Vial material |
HDPE |
PET |
Borosilicate glass |
| Vial color |
White |
Clear |
Clear |
| Diameter |
27 mm |
27 mm |
28 mm |
| Height with cap |
61 mm |
61 mm |
61 mm |
| Thread |
22-400 |
22-400 |
22-400 |
| Cap |
White PP |
White PP |
White PP |
| Liner |
Metal foil/pulp |
Metal foil/pulp |
Metal foil/pulp |
Even with the same named cap and liner, HDPE, PET, and glass can differ in chemical interaction, analytical background, optical response, thermal behavior, and instrument-fit characteristics. Method qualification must address the actual vial material.
Chemical Compatibility: Evaluate HDPE, PP, and Foil/Pulp Together
During laboratory use, a liquid scintillation vial may be exposed to sample liquids, scintillation cocktails, solvent vapors, condensation, and cleaning agents. For WHEATON 986701, the relevant materials are HDPE, polypropylene, and metal foil/pulp.
The manufacturer's general foil/pulp guidance identifies good resistance to several classes of organic chemicals, but compatibility of the complete assembly is not established by the liner alone. The HDPE vial and polypropylene cap must also withstand the actual formulation and conditions of use.
| Chemical exposure |
Qualification consideration |
| Hydrocarbon-containing cocktails |
Foil/pulp has good general resistance; HDPE, PP, complete mixture, and seal must still be evaluated |
| Alcohol-containing solutions |
General foil/pulp resistance described; verify the particular alcohol and conditions |
| Ketone-containing mixtures |
Review each constituent and its effect on the full assembly |
| Oils |
General liner resistance described; evaluate HDPE and polypropylene separately |
| Acidic samples |
DWK states that foil/pulp is not good for acids |
| Alkaline samples |
DWK states that foil/pulp is not good for alkalis |
| Mixed-solvent samples |
Combined solvents and additives may affect polymer and liner performance |
| Volatile organic samples |
Evaluate evaporation, vapor exposure, ventilation, and secondary containment |
| Trace-sensitive analysis |
Assess blanks, potential extractables, sample recovery, and carryover |
| Cleaning chemicals |
Confirm compatibility with the HDPE vial, PP cap, and foil/pulp liner |
This table provides a chemical compatibility review framework, not a certified approved-chemical list for the exact 986701 assembly. Verify concentration, time, temperature, and the specific solvent composition.
Important: The foil/pulp liner's general hydrocarbon resistance does not establish that the HDPE vial can safely contain every hydrocarbon scintillation cocktail. Review the complete assembly before use.
Liquid Scintillation Counting: Analytical and Optical Considerations
Liquid scintillation counting (LSC) is a laboratory technique used to quantify suitable radioactive samples. A sample is combined with an appropriate scintillation cocktail, and energy deposited in the cocktail produces light that a counting instrument can detect.
The vial is one part of the analytical system. Vial material and color, sample chemistry, cocktail formulation, counting geometry, background contributions, and instrument settings can all influence the measured result.
DWK's broader liquid scintillation-vial family description mentions consistent low background counts and high UV transmission. However, the family contains multiple materials and colors, including clear glass, PET, and white HDPE.
For WHEATON 986701, no exact numerical background count, UV transmission spectrum, isotope-specific counting efficiency, or instrument-independent detection limit was established in the reviewed manufacturer specifications.
- Background controls: Use method-defined blanks and background measurements.
- Instrument material selection: Confirm the instrument accepts white HDPE vials.
- Optical response: Do not assume the same UV transmission as clear glass.
- Counting efficiency: Establish through the actual instrument and analytical method.
- Quench correction: Follow the instrument and method's validated procedures.
- Working volume: Use the approved sample-to-cocktail ratio rather than nominal vial capacity.
- Analytical controls: Use standards, blanks, and appropriate sample recovery checks.
Analytical performance boundary: White HDPE must not be described as having the same verified UV transmission or counting background as borosilicate glass. WHEATON 986701 is a laboratory sample container, not a calibrated radiation-measurement instrument.
22-400 Screw Thread, Cap Fit, and Instrument Clearance
WHEATON 986701 uses a 22-400 threaded finish. DWK's Closure Liner Guide explains that the closure and container thread finishes must match. A 24-400 screw cap should not be assumed to fit a 22-400 vial.
The manufacturer specifies a 27 mm vial diameter, 57 mm height without cap, and 61 mm total assembled height. These values support preliminary instrument and storage-rack selection.
| Dimension or feature |
Practical significance |
| 20 mL nominal capacity |
Size classification; not a calibrated measuring volume |
| 27 mm diameter |
Check instrument holder, rack, and carousel fit |
| 57 mm uncapped height |
Vial-body dimension |
| 61 mm capped height |
Complete assembly clearance |
| 22-400 finish |
Requires matching screw cap |
| White HDPE body |
Confirm material/color acceptance in the counting method |
| No marking spot |
Use a suitable external identification system |
WHEATON's related clear-glass 20 mL vials have a published 28 mm diameter, rather than the 27 mm listed for this HDPE version. Do not assume identical equipment fit based on capacity or capped height alone.
Sterility and Autoclavability: Exact Product vs. General Material Guidance
DWK explicitly specifies WHEATON 986701 as non-sterile. The exact product record does not publish an autoclavability field.
DWK's separate Typical Properties of Plastics guide identifies HDPE as not autoclavable. Because 986701 uses an HDPE vial body, the assembled product should not be autoclaved without written, product-specific manufacturer approval.
The polypropylene cap's general material properties do not qualify the complete HDPE/PP/foil-pulp system for steam processing. Similarly, generic plastics data describing possible gas or radiation sterilization does not establish a validated process for the exact 986701 assembly.
| Question |
Manufacturer evidence and recommendation |
| Is 986701 supplied sterile? |
No; exact-SKU designation is non-sterile |
| Does the exact SKU publish an autoclavability rating? |
No field in the reviewed product record |
| Is HDPE generally autoclavable? |
DWK general plastics guide: No |
| Does a polypropylene cap establish autoclavability? |
No; complete assembly must be qualified |
| Is a validated sterilization cycle supplied? |
No exact-SKU process established |
Processing warning: Do not autoclave WHEATON 986701 based on the polypropylene cap's general heat characteristics. No validated 121°C steam cycle, sterile processing claim, or other SKU-specific sterilization procedure has been established.
Closure Handling, Seal Integrity, and Solvent Vapor Control
The attached white PP screw cap and foil/pulp liner form the manufacturer-defined 986701 closure system. However, the presence of a metal foil liner and correctly matched screw thread does not establish a certified leakproof, vapor-tight, hermetic, pressure-resistant, or hazardous-material transport seal.
Actual closure performance depends on the vial neck, cap threads, liner condition, chemical exposure, fill level, temperature, and method of cap application.
- Inspect the vial rim and cap threads for defects or contamination.
- Inspect the metal foil/pulp liner for damage or displacement.
- Use the specified 22-400 closure finish.
- Follow the laboratory's approved cap-application procedure.
- Do not assign an unsupported numerical tightening torque.
- Evaluate evaporation and vapor exposure for volatile mixtures.
- Use suitable secondary containment where required.
- Follow applicable chemical and radiological safety procedures.
Related WHEATON 20 mL Liquid Scintillation Vial Configurations
The WHEATON Vial Guide identifies several HDPE, PET, and glass scintillation vials. The following products vary by material, cap, liner, or packaging format. They are separate manufacturer catalog numbers and should not be treated as automatically approved substitutions.
| SKU |
Vial material |
Cap / liner |
Presentation / case |
| 986701 |
White HDPE |
White PP / foil-pulp |
Attached / 500 |
| 986700 |
White HDPE |
White PP / foamed PE |
Attached / 500 |
| 986702 |
White HDPE |
White urea / foil-cork |
Attached / 500 |
| 986704 |
White HDPE |
Polyethylene / linerless |
Attached / 500 |
| 986706 |
White HDPE |
White urea / PE cone |
Attached / 500 |
| 986711 |
White HDPE |
White PP / foil-pulp |
Caps separate / 500 |
| 986721 |
White HDPE |
White PP / foil-pulp |
Caps separate / 1000 |
| 986731 |
Clear PET |
White PP / foil-pulp |
Attached / 500 |
| 986541 |
Clear borosilicate glass |
White PP / foil-pulp |
Attached / 500 |
The products in this comparison share a nominal 20 mL capacity and 22-400 closure family, but they are not identical. The white HDPE 986701 is the attached-cap, foil/pulp, 500-count configuration.
Procurement warning: WHEATON 986711 has caps packed separately and 500 per case. WHEATON 986721 also has caps packed separately but comes in a 1,000-count case. Neither should be confused with 986701's attached-cap, 500-count presentation.
Case Packaging, Receiving Inspection, and Traceability
DWK lists 500 vials per case for WHEATON 986701, with caps attached to the vials. The current exact-SKU manufacturer specification does not establish a particular inner tray quantity, carton weight, or shipping dimensions.
- Verify SKU: 986701.
- Verify vial material: White HDPE, not PET or glass.
- Verify capacity: 20 mL nominal.
- Verify closure: White PP, 22-400, metal foil/pulp.
- Verify cap presentation: Attached to vials.
- Verify quantity: 500 per case.
- Inspect physical condition: Check the vials, threads, caps, and liners.
- Retain traceability: Document applicable receiving and manufacturer lot information.
- Confirm specialized packaging: Request manufacturer confirmation if inner packaging or cleanliness is important.
Recommended Laboratory Preparation and QC Checklist
- Confirm the manufacturer SKU: Verify WHEATON 986701.
- Check materials: White HDPE vial, PP cap, metal foil/pulp liner.
- Inspect the assembly: Look for cracks, deformation, cap defects, or damaged liner surfaces.
- Validate chemical compatibility: Evaluate the entire sample and scintillation cocktail formulation.
- Review acids and alkalis: DWK identifies these as foil/pulp liner limitations.
- Check instrument compatibility: Confirm the counter accepts white HDPE and the 27 x 61 mm geometry.
- Use method-defined volumes: Follow prescribed sample and cocktail amounts.
- Apply the closure correctly: Use approved cap-handling and seal-verification procedures.
- Identify each sample: Use external labels or barcodes because no marking spot is supplied.
- Perform analytical QC: Use blanks, calibration standards, background and quench procedures as required.
- Apply laboratory safety controls: Follow chemical, radiation, ventilation, and waste-handling requirements.
- Avoid unapproved heat processing: General DWK plastics guidance identifies HDPE as non-autoclavable.
- Maintain traceability: Record applicable sample, lot, instrument, and analytical method information.
Cleaning, Inspection, Storage, and Reuse Considerations
Any proposed cleaning or reuse process for WHEATON 986701 must account for the HDPE vial, polypropylene cap, and metal foil/pulp liner. Different components may respond differently to cleaning chemicals, mechanical handling, or heat.
Liquid scintillation vials may contain chemical solvents or radioactive residues. The laboratory should determine whether reuse is permitted by its analytical method and whether contamination or sample carryover creates unacceptable risks.
- Confirm that the analytical method permits reuse.
- Assess hazardous or radioactive contamination before handling.
- Use cleaning reagents compatible with HDPE, PP, and foil/pulp.
- Avoid abrasive equipment or damage to threads and liner surfaces.
- Do not use unapproved autoclaving or excessive heat.
- Inspect the vial and closure before any permitted reuse.
- Use required blank and carryover acceptance checks.
- Follow approved storage, labeling, and waste procedures.
Controlled Laboratory and Cleanroom Qualification
WHEATON 986701 may be evaluated for appropriate analytical laboratory applications, but the exact manufacturer specification identifies it as non-sterile. The reviewed record does not establish an ISO 14644 product cleanliness class, validated sterile barrier, endotoxin limit, DNase/RNase-free status, or certified particle-release specification.
For controlled-environment use, follow facility procedures for material introduction, labeling, contamination control, and product qualification. A laboratory plastic material designation does not automatically establish suitability for aseptic processing, sterile compounding, or pharmaceutical manufacturing.
Qualification boundary: WHEATON 986701 should not be represented as sterile, ISO-classified, pharmaceutical-grade, or cleanroom-ready without specific supporting manufacturer documentation.
Important Limitations and Unsupported Assumptions
- Not a glass vial: The exact body material is white HDPE.
- Not clear PET: PET is a separately listed WHEATON configuration.
- Not 28 mm diameter: The listed diameter is 27 mm.
- Not 24-400: This product uses a 22-400 screw finish.
- Not a urea cap: The specified cap is polypropylene.
- Not a foam liner: The liner is metal foil/pulp.
- Not foil/cork: Pulp and cork are different backing materials.
- Not PTFE-faced: No PTFE lining is specified.
- Not sterile: Exact manufacturer designation is non-sterile.
- No exact-SKU autoclavability field: General HDPE data identifies the material as non-autoclavable.
- No universal acid or alkali suitability: DWK specifically warns against these exposures for foil/pulp.
- No universal organic-solvent compatibility: All assembly components must be evaluated.
- No certified leakproof or vapor-tight rating: No exact product test value established.
- No guaranteed scintillation background: No numerical SKU-specific result established.
- No verified UV transmission percentage: Shared family descriptions should not be transferred to white HDPE.
- No universal counter compatibility: Verify equipment and method fit.
- No calibrated fill accuracy: The 20 mL capacity is nominal.
- No marking spot: Use appropriate external identification.
- No confirmed inner carton breakdown: Verify if packaging subdivisions matter.
- No certified hazardous-material transport qualification: Ordinary vial packaging is not a shipping approval.
Technical FAQs
What is WHEATON 986701?
A 20 mL white HDPE liquid scintillation vial with an attached white polypropylene 22-400 cap and metal foil/pulp liner.
Is WHEATON 986701 made from glass?
No. The exact vial material is high-density polyethylene (HDPE).
What color is the vial?
White, according to the exact DWK manufacturer specifications.
What is the capacity?
20 mL nominal.
What are the dimensions?
27 mm diameter, 57 mm height without cap, and 61 mm overall height including cap.
Are the caps included?
Yes. DWK identifies the caps as attached to the vials.
What is the cap material?
White polypropylene (PP).
What thread finish does it use?
22-400. The closure must have a matching thread finish.
What is the liner made of?
Metal foil/pulp. DWK generally describes this construction as aluminum foil bonded to pulp board.
How is 986701 different from 986700?
986701 uses a metal foil/pulp liner; 986700 uses foamed polyethylene. Their nominal HDPE vial dimensions and PP cap specifications are the same.
Is metal foil/pulp resistant to hydrocarbons?
DWK describes good general liner resistance to hydrocarbons, oils, ketones, and alcohols, but the full HDPE vial-and-cap assembly must still be qualified.
Can foil/pulp be used with acids or alkalis?
DWK's general liner guidance specifically states that foil/pulp is not good for acids or alkalis.
Is foil/pulp the same as foil/cork?
No. The backing materials and manufacturer catalog configurations are different.
Is the liner PTFE-faced?
No PTFE facing is specified. The exact liner is metal foil/pulp.
Is the vial sterile?
No. DWK identifies 986701 as non-sterile.
Can 986701 be autoclaved?
The exact product page does not publish an autoclavability field. DWK's general plastics guide identifies HDPE as non-autoclavable, so do not autoclave the assembled product without written manufacturer authorization.
Does 986701 have high UV transmission?
No exact-SKU UV transmission value is published in the reviewed record. The shared family statement should not be treated as a verified optical specification for white HDPE.
Is counting background certified?
No exact numerical background count or counting efficiency was established in the reviewed SKU information.
Will it fit any scintillation counter?
Not automatically. Verify the 27 mm diameter, 61 mm capped height, white HDPE material, and instrument-specific requirements.
Is the closure leakproof?
No certified product-specific leak rate or vapor-tight rating was established. Seal performance requires application testing when relevant.
Does the vial have a marking spot?
No. Use a suitable label or barcode for sample identification.
What is the difference between 986701 and 986711?
Both use the same named white HDPE, PP, and foil/pulp configuration, but 986701 has caps attached while 986711 has caps packed separately. Both are listed at 500 per case.
What is the difference between 986701 and 986721?
986701 has attached caps and 500 per case. WHEATON 986721 uses separately packed caps and is listed at 1,000 per case.
How is 986701 different from 986731?
986731 is a PET vial, whereas 986701 is white HDPE. Both use polypropylene caps and metal foil/pulp liners.
How is 986701 different from 986541?
986541 uses borosilicate glass and has a 28 mm diameter. WHEATON 986701 uses white HDPE and has a 27 mm diameter.
How many vials are supplied per case?
500 vials with the specified attached caps and liners.
Manufacturer Technical References
The external links above lead to DWK technical-information resources, not manufacturer product-detail pages, catalogs, or shopping pages. General material guidance does not replace exact-product qualification or manufacturer documentation.
For quotations or product questions, email Sales@SOSsupply.com or call (214) 340-8574.
SOSCleanroom can help verify WHEATON vial materials, 22-400 closures, liner configurations, cap presentation, case quantities, and applicable manufacturer documentation.
Technical insight: WHEATON 986701 combines a white HDPE vial with a polypropylene screw cap and metal foil/pulp liner. Laboratory suitability depends on the entire assembly, actual sample chemistry, instrument requirements, and validated analytical procedures.
Last updated: October 28, 2026