Skip to main content

Teknipure TM-MFP9G-516P TekniMop Microfiber Knit Pocket Mop Cover, Integrated Pad, 5″x16″, 9% IPA (Refills) (Case Qty.)

$798.61
SKU: TM-MFP9G-516P CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout
Type:
Pre-Wet Mop

Teknipure TM-MFP9G-516P TekniMop Microfiber Knit Pocket Mop Cover, Integrated Pad, 5″x16″, 9% IPA (Refills) (Case Qty.) - SOSCleanroom Standard Specification

The Teknipure TM-MFP9G-516P TekniMop™ Microfiber Knit Pocket Mop Cover is a non-sterile, ready-to-use cleanroom mop cover with an integrated foam pad and presaturation with 9% isopropyl alcohol (IPA) / 91% DI water. Designed for large-surface cleaning in critical and controlled environments, its knit microfiber construction supports effective capture and retention of small particles and contaminants while the integrated pad provides additional liquid capacity, cushioned surface contact, and controlled solution delivery.

Microfiber cleaning + integrated pad + ready-to-use 9% IPA: TM-MFP9G-516P combines a 5" x 16" microfiber cleaning surface, integrated foam pad, and standardized 9% IPA / 91% DI water presaturation in one ready-to-use mop cover. Its resealable gusset packaging helps minimize chemical evaporation and maintain consistent saturation between cover changes.

Specifications:
  • Part Number: TM-MFP9G-516P
  • Product Type: Presaturated microfiber knit pocket mop cover with integrated foam pad
  • Size: 5" x 16"
  • Material: Knit microfiber
  • Pad: Integrated foam pad
  • Attachment: Pocket-style
  • Solution: 9% isopropyl alcohol (IPA) / 91% DI water
  • Format: Presaturated
  • Sterility: Non-sterile
  • Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
  • Packaging: 10 covers/resealable gusset bag, 8 bags/case
  • Total Case Quantity: 80 covers/case
  • Compatible Hardware: TekniMop™ 5" x 16" mop hardware, including TM-PFM516HF
Where TM-MFP9G-516P Fits in Controlled Environments

TM-MFP9G-516P is designed for large-surface controlled-environment cleaning where operators need both effective contamination pickup and standardized 9% IPA application in a ready-to-use format. Its 5" x 16" cleaning footprint provides practical coverage for floors, walls, ceilings, equipment surfaces, and other broad facility areas.

The knit microfiber cleaning surface captures and retains fine particles and contaminants, while the integrated foam pad increases fluid-holding capacity and provides cushioned contact with the target surface. The presaturated pad releases solution in a controlled manner to support consistent surface wetting throughout the cleaning procedure.

Typical program fit: Cleanroom floor cleaning, wall cleaning, ceiling cleaning, large equipment and facility surfaces, precleaning before disinfectant applications, residue removal, controlled 9% IPA application, surface wetting, and general cleaning of large controlled-environment areas.

TM-MFP9G-516P is supplied non-sterile and presaturated with 9% IPA / 91% DI water. Final suitability should be evaluated according to the target surface, required chemistry, contamination-control objective, sterile/non-sterile workflow, validated cleaning procedure, compatible hardware, and facility SOP.

About the Manufacturer:

Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, semiconductor and microelectronics manufacturing, optics, aerospace and defense, laboratories, and other controlled environments.

Within the TekniMop™ microfiber mop-cover family, Teknipure offers dry and presaturated configurations designed to combine effective contamination pickup with controlled liquid delivery. Integrated-pad constructions add fluid capacity and cushioned surface contact while reducing the number of separate system components required during setup.

TM-MFP9G-516P Features:
  • High-density knit microfiber cleaning surface
  • 5" x 16" format for large-surface controlled-environment cleaning
  • Integrated foam pad for increased fluid capacity and cushioned surface contact
  • Pad covered on all sides to help prevent particle generation from exposed pad material
  • Pocket-style construction for secure installation on compatible mop hardware
  • Presaturated with 9% IPA / 91% DI water
  • Ready-to-use format eliminates manual IPA measuring or spraying
  • Consistent solution delivery for standardized surface wetting
  • Microfiber construction captures and retains fine particles and contaminants
  • Low-particulate construction for contamination-control applications
  • Presaturated integrated pad delivers controlled and consistent liquid release
  • Self-standing resealable gusset packaging
  • Resealable packaging helps reduce chemical evaporation and maintain mop saturation
  • Non-sterile configuration
TM-MFP9G-516P Benefits:
  • Ready-to-use 9% IPA application: Factory presaturation eliminates manual measuring, spraying, and saturation steps when 9% IPA is specified by the cleaning procedure.
  • Effective contamination pickup: High-density microfiber construction supports capture and retention of small particles and contaminants from critical surfaces.
  • Integrated-pad convenience: The built-in foam pad eliminates the need to purchase, install, and manage a separate mop pad.
  • Increased fluid capacity: The integrated pad provides additional liquid-holding capacity for controlled wet-cleaning procedures.
  • Controlled solution release: The presaturated integrated pad provides repeatable liquid delivery for uniform surface wetting.
  • Cushioned surface contact: The foam pad provides a soft cleaning interface and helps maintain consistent contact across the target surface.
  • Large-area efficiency: The 5" x 16" footprint provides practical coverage for floors, walls, ceilings, equipment surfaces, and other broad cleaning areas.
  • Reduced evaporation: Resealable packaging helps limit IPA evaporation and chemical loss from unused covers after opening.
  • Process consistency: Factory-controlled presaturation helps reduce variation associated with manually preparing individual mop covers.
  • Reduced component handling: Integrating the foam pad into the cover removes a separate assembly step and eliminates an additional potential contamination source.
Common Applications:
  • Cleanroom floor cleaning
  • Wall cleaning
  • Ceiling cleaning
  • Large equipment and facility surfaces
  • Precleaning before disinfectant applications
  • Particle and residue removal
  • Controlled 9% IPA application
  • Uniform surface wetting
  • General cleaning of large controlled-environment areas
Best-Practice Use:
  • Install securely: Fit the pocket-style cover fully onto compatible mop hardware so the integrated foam pad remains evenly positioned beneath the microfiber cleaning surface.
  • Use directly from the presaturated package: TM-MFP9G-516P is supplied with 9% IPA / 91% DI water and does not require manual IPA saturation before use.
  • Reseal the package: Close the resealable gusset bag promptly after removing a cover to help minimize IPA evaporation and maintain saturation of the remaining covers.
  • Use controlled cleaning patterns: Follow the unidirectional, overlapping, or other validated mopping pattern established by the facility for the surface being cleaned.
  • Work from cleaner to less-clean areas: Follow the facility's established contamination-control sequence and avoid moving collected contamination back into previously cleaned areas.
  • Maintain even surface contact: Allow the microfiber surface and integrated pad to maintain consistent contact rather than relying on excessive downward pressure.
  • Follow the validated IPA procedure: Maintain the surface conditions and drying requirements established by the facility for 9% IPA cleaning.
  • Change covers as required: Replace the cover according to surface area, contamination load, room transition, solution condition, or other changeout criteria established by the facility.
  • Follow non-sterile material controls: TM-MFP9G-516P is supplied non-sterile and should be introduced and used according to the facility's material-transfer and contamination-control procedures.
Selection Notes (TM-MFP9G-516P vs. Other TekniMop™ Options)
  • TM-MFP9G-516P: Choose this version when a ready-to-use 9% IPA microfiber mop cover with an integrated foam pad is preferred for large-surface cleaning.
  • TM-MFP-516P: Select the dry microfiber counterpart when the facility needs to choose its own cleaning chemistry or directly control saturation.
  • TM-MFPK9G-516P: Compare this 9% IPA configuration when evaluating Teknipure's other 5" x 16" microfiber mop-cover options with integrated absorbency.
  • Dry vs. presaturated: TM-MFP9G-516P provides standardized ready-to-use 9% IPA delivery. Dry alternatives provide greater flexibility when other cleaning or disinfecting chemistries are required.
  • Integrated pad: The built-in pad increases liquid capacity, provides cushioned surface contact, supports controlled solution delivery, and eliminates the need to manage a separate pad component.
  • 9% IPA vs. other solution formats: Select solution concentration according to the validated cleaning procedure and facility SOP rather than treating different IPA concentrations as interchangeable.
Compatible TekniMop™ Products

Compatible Mop Hardware

  • TM-PFM516HF: 5" x 16" polyethylene frame with extendable aluminum handle
Building a TM-MFP9G-516P TekniMop™ System

The TM-MFP9G-516P is the presaturated microfiber mop-cover component of a TekniMop™ large-surface cleaning system. Pair the cover with compatible 5" x 16" TekniMop™ hardware for a ready-to-use cleaning configuration designed around standardized 9% IPA application.

System configuration:
TM-MFP9G-516P Microfiber Knit 9% IPA Mop Cover with Integrated Foam Pad + TM-PFM516HF 5" x 16" Frame & Extendable Aluminum Handle System

The integrated pad is already built into the mop cover, so no separate pad component is required. The complete hardware system provides the supporting frame and handle for large-surface controlled-environment cleaning.

Workflow note: TM-MFP9G-516P is supplied non-sterile and ready to use with 9% IPA / 91% DI water. Keep the resealable package closed when covers are not being removed to help minimize IPA evaporation. Material transfer, cover changeout, surface wetting, use, and disposal should follow the applicable facility SOP.

Notes: Looking for application guidance or qualification context for the Teknipure TM-MFP9G-516P TekniMop™ Microfiber Knit Pocket Mop Cover with Integrated Foam Pad? Open the SOSCleanroom Technical Vault tab above for detailed large-surface cleaning guidance, microfiber mop-cover selection, 9% IPA application considerations, floor/wall/ceiling cleaning technique, system configuration, cover changeout considerations, and compatibility information.

SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.

Product page updated: Oct. 28, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
Knit Microfiber 5" x 16" Integrated Absorbent Pad Pocket Attachment 9% IPA / 91% DI Water Non-Sterile 80 Covers/Case

Teknipure TekniMop™ TM-MFP9G-516P: ready-to-use microfiber pocket cover with an integrated absorbent pad

The Teknipure TekniMop™ TM-MFP9G-516P is a 5" x 16" non-sterile microfiber knit pocket mop cover with an integrated absorbent pad, presaturated with 9% IPA / 91% DI water. Its supplied configuration combines the cleaning textile, absorbent backing, and solution in one ready-to-use consumable. [1, 2]

Operations takeaway: Choose this configuration when the approved cleaning step calls for the supplied solution and a compatible pocket-mop system. Factory preparation removes the initial manual wetting step; the facility still defines surface coverage, handling, and cover replacement.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer: Teknipure
  • Part number: TM-MFP9G-516P
  • Product: TekniMop™ Microfiber Knit Pocket Mop Cover with Integrated Absorbent Pad, 9% IPA
  • Nominal size: 5" x 16" (13 cm x 41 cm)
  • Cleaning material: Knit microfiber
  • Pad: Integrated absorbent pad
  • Attachment: Pocket-style
  • Supplied condition: Presaturated
  • Solution: 9% isopropyl alcohol / 91% deionized water
  • Sterility: Non-sterile
  • Cleanroom positioning: Manufacturer lists ISO Class 5–8
  • Packaging: 10 covers/resealable gusset bag, 8 bags/case
  • Total case quantity: 80 covers/case
  • Designated frame: TM-PFM516F
  • Designated frame-and-handle kit: TM-PFM516HF

Configuration references: Teknipure product information and technical documentation. Integrated-pad designation and packaging follow the exact-SKU entry in the August 2026 mop price list. [1, 2, 3]

Exact-SKU control: TM-MFP9G-516P and TM-MFPK9G-516P are separate products. Preserve the complete part number on orders, receiving records, and cleaning procedures rather than shortening either to “5 x 16 microfiber IPA mop.”


Integrated absorbent pad: liquid capacity and cushioning without a separate component

Integrated absorbent pad: Built into the cover to provide additional liquid-holding capacity and cushioned surface contact without requiring a separate pad. [3]

Teknipure describes the pad as enclosed on all sides. [2] The cleaning face and internal absorbent component remain parts of one assembly, rather than separate items that must be fitted during setup.

  • Before installation: Inspect the exterior and pockets for damage.
  • During setup: Do not add an unapproved backing layer beneath the supplied cover.
  • During use: Maintain suitable frame orientation rather than relying on cushioning to compensate for poor contact.
  • At replacement: Change the complete consumable assembly according to the procedure.

Condition-control point: Remove the cover from service if damage exposes internal material, affects retention, or prevents the intended working face from contacting the surface.


Microfiber contact: separate physical pickup from antimicrobial action

Teknipure describes its microfiber mop-cover family as low-linting and intended for particle, residue, and microorganism capture. [3]

  • Removal objective: Identify the contamination the cleaning step must remove.
  • Surface acceptance: Establish how the treated area will be checked.
  • Loading limit: Define when collected contamination requires a fresh cover.
  • Claim boundary: Do not turn a physical-pickup description into a microbial kill claim, zero-particle specification, or unlimited-use allowance.

Qualification question: Does the complete cleaning method achieve the required surface condition? Visible wetting and successful contamination removal are not interchangeable acceptance criteria.


9% IPA: a specified cleaning solution, not a substitute for every alcohol step

The applicable Teknipure safety data sheet identifies technical cleaning as the recommended use. [5] Select this cover for the cleaning step specified by the facility rather than assuming that any alcohol-containing consumable can replace any other.

  • Cleaning: Define the target residue and the required removal result.
  • Precleaning: Establish the condition required before a separate disinfectant is applied.
  • Surface compatibility: Evaluate the actual substrate, coatings, seals, and moisture-sensitive components.
  • Process transitions: Follow the approved sequence between this cleaning step and subsequent treatment.

Antimicrobial boundary: CDC guidance describes a substantial decline in alcohol germicidal activity below 50% concentration. This general guidance is not a product-specific efficacy test, but it reinforces why a 9% IPA cleaning cover should not inherit the kill claims or contact times of a 70% IPA product. [6]


Presaturated preparation: control the workflow after opening

The product arrives with its specified solution already applied. [2] The facility should therefore focus on maintaining the supplied configuration during transfer, installation, and use.

  • Verify before opening: Match the full SKU and required solution to the cleaning procedure.
  • Protect the working face: Avoid unintended contact during removal and installation.
  • Do not improvise dilution: Adding water or alcohol changes the supplied chemistry.
  • Do not mix cleaning steps: Use a fresh, appropriate consumable when another chemistry is required.

Process-control point: Ready-to-use preparation does not define the permitted cleaning area, pass count, or time in service. Those limits belong in the approved method.


Packaging: 10 covers per bag, 80 covers per case
  • Working package: 10 covers per resealable gusset bag
  • Case configuration: 8 bags
  • Total case quantity: 80 covers

Packaging reference: Teknipure Mops Price List, August 2026, TM-MFP9G-516P entry. [1]

Purchasing distinction: This is a multi-cover working bag, not an individually bagged presentation. Specify both the exact part number and the order unit so a bag is not confused with a complete case.


Opened-package handling: protect the remaining supply

Teknipure describes self-standing resealable packaging intended to limit solution loss between removals. [2]

  • Remove only the cover required for the task and close the package promptly.
  • Keep used covers and contaminated handling surfaces away from the remaining contents.
  • Do not return a used cover to the bag.
  • Define the response to a damaged closure, questionable wetness, or compromised contents.
  • Establish any opened-package use limit separately from the manufacture-based shelf life.

Operational guidance: Resealing is a package-handling step, not a new expiration date or a method for restoring contaminated contents.


Compatible hardware: the polyethylene frame and aluminum handle system

The exact cover row in Teknipure’s TDS lists TM-PFM516F and TM-PFM516HF. [3] The kit’s product page also names TM-MFP9G-516P among its compatible covers. [4]

  • TM-PFM516F: Collapsible polyethylene frame, 5" x 16".
  • TM-PFM516H: Extendable aluminum handle with a 4–6 ft working range.
  • TM-PFM516HF: Combined frame-and-handle kit.

Hardware descriptions follow Teknipure’s product records. [1, 4]

System configuration: TM-MFP9G-516P cover + TM-PFM516F frame + TM-PFM516H handle, or the corresponding TM-PFM516HF kit.


Pocket installation: confirm fit before cleaning
  • Prepare the frame: Confirm its required cleanliness status and inspect the hardware.
  • Follow the fitting method: Seat the cover using the designated frame instructions.
  • Check the frame position: Confirm that the collapsible frame remains in its intended operating configuration.
  • Check alignment: Correct folds or displacement that interfere with the cleaning face.
  • Check retention: Verify that the cover stays seated during the planned movement.

Fit-control rule: Use documented part-number compatibility rather than nominal dimensions alone. Do not transfer another 5" x 16" cover’s hardware listing to this SKU.


Manufacturer-listed applications
  • Cleanroom floors, walls, and ceilings
  • Precleaning before disinfectant application
  • Residue removal
  • General large-area cleaning

Application reference: Teknipure TM-MFP9G-516P product information. [2]

Application boundary: A broad use category does not establish performance against every residue or suitability for every substrate. Qualify the actual contamination, surface, and cleaning sequence.


Large-surface technique: make coverage repeatable

The following setup and use recommendations are SOS operational guidance for procedure review. They are not manufacturer-validated coverage limits, stroke counts, or contact times for this SKU.

  • Plan the route: Identify the start, boundaries, obstacles, and completion point.
  • Define overlap: Specify how adjacent paths will avoid untreated strips.
  • Check actual contact: Verify the assembled cover’s working face against the surface throughout each pass.
  • Control progression: Follow the approved surface sequence and cleaning-zone rules.
  • Review each orientation: Evaluate floor, wall, and ceiling setups at the intended handle length and working angle.

Coverage rule: Do not derive a universal square-foot rating from cover dimensions. Establish the working limit using the actual surface, contamination load, solution delivery, and cleaning pattern.


Solution delivery: define when the cover has finished its useful cycle
  • Starting condition: Inspect the package and cover according to the approved acceptance criteria.
  • During use: Check whether the cover continues to produce the surface condition required by the method.
  • At the limit: Replace a depleted or loaded cover rather than compensating with extra pressure.
  • After interruption: Apply the facility’s rules for an exposed cover or paused cleaning task.
  • Before another chemistry: Complete the required transition rather than applying a second formulation to the same used cover.

Process distinction: For this cleaning step, define the required wetting and removal conditions. When disinfection follows, use the separate disinfectant’s specified application and contact requirements.


Change-out triggers: remaining liquid is not the only limit
  • Assigned area: The cleaning section or permitted coverage limit is complete.
  • Zone transition: The procedure requires a fresh cover before entering another area.
  • Contamination: The working face is loaded, visibly soiled, or leaves an unacceptable result.
  • Wetness: The cover no longer provides the required surface condition.
  • Handling event: The cover contacts an uncontrolled surface.
  • Physical condition: Damage, displacement, or poor retention interferes with use.
  • Process change: Another cleaning step requires a fresh consumable.

Decision rule: Replace at the first applicable process limit. A cover does not have to become both visibly dirty and dry before replacement is justified.


Best-practice use (9% IPA presaturated pocket cover)
  1. Verify identification: Match the full part number and solution requirement to the approved task.
  2. Inspect the package: Check integrity, lot identification, expiration, and storage controls.
  3. Prepare the hardware: Confirm the designated frame-and-handle combination and its required cleanliness status.
  4. Apply safety controls: Follow the current SDS and facility requirements before opening the package.
  5. Remove the required cover: Protect the cleaning face and close the remaining supply promptly.
  6. Install and verify: Check pocket retention, frame position, and even alignment.
  7. Execute the approved pattern: Maintain the defined sequence, overlap, contact, and surface conditions.
  8. Replace at the limit: Apply the established contamination, wetness, area, or zoning trigger.
  9. Complete subsequent treatment: Follow any separate disinfection or surface-release requirements.
  10. Close out the task: Dispose of the cover appropriately and prepare reusable hardware for storage or its next use.

Cleanroom positioning does not establish sterility

Teknipure lists this cover for ISO Class 5–8 environments and identifies it as non-sterile. [2]

Qualification point: Confirm the required consumable presentation independently from the room classification. An unopened bag or alcohol presaturation does not authorize substitution where a sterile product is specified.


Storage and shelf life: 13 months from manufacture
  • Published shelf life: 13 months from manufacture for the 6% and 9% IPA presaturated mop-cover category.
  • TDS storage guidance: Clean, dry environment at 15°C–30°C.
  • Expiration control: Follow the supplied labeling and applicable lot records.

Storage and shelf-life reference: Large Surface Mopping Tools TDS, page 1. [3]

Inventory-control point: Do not carry over a dry cover’s shelf life or a 70% IPA cover’s expiration period. Receipt and opening do not restart the manufacture-based period; establish opened-package handling separately.


Safety: lower alcohol concentration does not mean hazard-free

Teknipure’s 6–10% Isopropyl Alcohol Cleaning Wipes and Mop Covers SDS, revised September 21, 2026, explicitly includes TM-MFP9G-516P. It lists flammable liquid, Category 3 and serious eye irritation, Category 2A. [5]

  • Control heat, sparks, flames, and other ignition sources.
  • Provide appropriate ventilation and eye protection.
  • Keep original packaging closed and protect it from heat and direct sunlight.
  • Follow the SDS and facility procedure for incompatible materials and waste handling.

Safety-document rule: Do not infer a nonflammable or universal transport classification solely from the alcohol percentage. Use the applicable SDS and the requirements for the actual handling or shipping activity.


Hardware preparation: do not transfer another platform’s processing limits

Teknipure’s hardware table marks the designated polyethylene frame and aluminum handle system as not autoclavable. [3]

Processing boundary: Use the preparation method applicable to this hardware. Neither another frame’s rating nor a shared cover size establishes permission to autoclave the assembly or reprocess the presaturated consumable.


Related 5" x 16" options: keep the part numbers and case packs separate
  • TM-MFP9G-516P: 9% IPA presaturated integrated-pad pocket cover; 10 covers/resealable gusset bag, 8 bags/case, 80 covers/case.
  • TM-MFP-516P: Dry integrated-pad pocket cover; 1 cover/bag, 50 bags/case, 50 covers/case.
  • TM-MFPK9G-516P: Separately specified 9% IPA presaturated integrated-pad pocket cover; 5 covers/resealable gusset bag, 10 bags/case, 50 covers/case.

Descriptions and packaging follow the separate entries in Teknipure’s August 2026 mop price list. [1]

Comparison rule: These records establish differences in supplied condition and packaging. They do not establish equivalence in pad thickness, liquid loading, absorbency, or hardware compatibility. Retain the exact approved SKU.


Selection logic and qualification boundaries
  • Choose this configuration when: The approved method calls for its supplied chemistry, non-sterile presentation, pocket attachment, and designated hardware.
  • Choose a dry alternative when: The facility needs to select and apply another compatible chemistry.
  • Use a designated sterile option when: Sterility is an explicit consumable requirement.
  • Request quantitative data when needed: Do not invent particle limits, extractables, liquid volume per cover, or coverage ratings.
  • Do not infer reprocessing: Treat reuse, laundering, replenishment, or sterilization as separate requirements needing appropriate authorization.

Final selection principle: Match the specified product configuration to the cleaning step, then qualify the complete method. Similar dimensions and product names are not sufficient grounds for substitution.


Why source TekniMop™ through SOSCleanroom
  • Exact-SKU selection: Get help distinguishing similar cover names, chemistry configurations, and case packs.
  • System selection: Review the consumable, designated hardware, and intended cleaning task together.
  • Documentation support: Request manufacturer information for purchasing, qualification, and procedure review.
  • Coordinated procurement: Source mop covers and hardware alongside the other consumables required by the cleaning program.

Manufacturer documentation and technical references
  • [1] Teknipure Mops Price List, August 2026: Exact-SKU integrated-pad descriptions and controlling packaging quantities.
  • [2] Teknipure TM-MFP9G-516P product information: Solution composition, supplied condition, attachment, packaging features, cleanroom positioning, and intended applications.
  • [3] TekniMop™ Large Surface Mopping Tools TDS: Page 1 for shelf life and storage; page 4 for hardware processing limits; pages 5–6 for cover construction and exact-SKU compatibility.
  • [4] Teknipure TM-PFM516HF product information: Polyethylene frame, extendable aluminum handle, and compatible cover listings.
  • [5] Teknipure 6–10% Isopropyl Alcohol Cleaning Wipes and Mop Covers SDS: Revision September 21, 2026; product identification, hazards, handling, storage, and disposal.
  • [6] CDC Chemical Disinfectants guidance, Alcohol section: General concentration-dependent antimicrobial context, not product-specific efficacy evidence.

Documentation hierarchy: Use the exact SKU, specified order unit, product labeling, and applicable manufacturer records for purchasing and receiving. SOS operational guidance supports selection and procedure review; it does not replace a facility-approved or validated cleaning method.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.