Skip to main content

Teknipure TM-QP258 TekniMop 2Ply Polyester Pocket Mop Cover, 2.5″ x 8″ (Refills) (Case Qty.)

$301.24
SKU: TM-QP258 CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout
Type:
Dry Mop

Teknipure TM-QP258 TekniMop 2Ply Polyester Pocket Mop Cover, 2.5″ x 8″ (Refills) (Case Qty.)

The Teknipure TM-QP258 TekniMop™ 2-Ply Polyester Pocket Mop Cover is a dry, non-sterile cleanroom mop cover designed for small-surface and isolator cleaning applications. Its durable 2-ply polyester construction provides increased liquid retention and controlled solution release for consistent surface wetting, residue removal, spill control, and application of compatible cleaning and disinfecting solutions in critical and controlled environments.

High-absorbency small-surface cleaning: TM-QP258 combines a compact 2.5" x 8" pocket format with durable 2-ply polyester construction. Supplied dry and non-sterile, it allows facilities to select and control the cleaning chemistry and saturation level required by their cleaning procedure while providing greater liquid-holding capacity than single-ply alternatives.

Specifications:
  • Part Number: TM-QP258
  • Product Type: 2-ply polyester pocket mop cover
  • Size: 2.5" x 8" (6 cm x 20 cm)
  • Material: 2-ply polyester
  • Attachment: Pocket-style
  • Format: Dry
  • Sterility: Non-sterile
  • Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
  • Packaging: 1 cover/bag, 10 bags/pack, 10 packs/case
  • Total Case Quantity: 100 covers/case
  • Compatible Carbon Fiber Frame: TKM27
  • Compatible Stainless Steel System: TM-QP258-SS 2.5" x 8" flat mop frame and extendable handle
Where TM-QP258 Fits in Controlled Environments

TM-QP258 is designed for small-surface cleaning applications where a compact mop system can provide more controlled access than a conventional large-surface mop. Teknipure identifies applications including isolators, RABS, biosafety cabinets, gloveboxes, pass-through chambers, equipment surfaces, work surfaces, benches, and other confined or difficult-to-access areas.

The 2-ply polyester construction provides increased liquid retention for cleaning procedures that require solution application, surface wetting, residue removal, or liquid pickup. Its controlled liquid-release characteristics support consistent distribution of cleaning chemistry across the target surface.

Typical program fit: Isolator and RABS cleaning, biosafety cabinet cleaning, gloveboxes, pass-through chambers, equipment and work surfaces, benches, confined areas, precleaning, residue removal, compatible disinfectant and sanitizer application, and spill control.

TM-QP258 is supplied dry and non-sterile. Cleaning chemistry, saturation level, cover changeout frequency, and suitability for a particular controlled environment should be established according to the facility's cleaning procedure and SOP.

About the Manufacturer:

Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, interchangeable handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, semiconductor and microelectronics manufacturing, optics, aerospace and defense, compounding pharmacies, laboratories, and other controlled environments.

Within the TekniMop™ small-surface system, Teknipure offers dry, presaturated, sterile, and non-sterile mop-cover configurations so facilities can select the format appropriate for their cleaning chemistry, sterility requirements, contamination-control objective, and facility procedures.

TM-QP258 Features:
  • Durable 2-ply polyester construction
  • 2.5" x 8" pocket-style format for small-surface cleaning
  • Dry configuration allows facility-controlled solution selection and saturation
  • Non-sterile format
  • Increased liquid retention compared with single-ply alternatives
  • Controlled liquid release for consistent surface wetting
  • Compatible with IPA, sporicidal agents, and common cleanroom disinfectants and cleaning solutions as specified by Teknipure
  • Designed for low particulate generation in controlled-environment cleaning
  • Compatible with the TKM27 TekniMop™ carbon fiber flat mop frame
  • Compatible with the TM-QP258-SS stainless steel 2.5" x 8" mop system
  • 1 cover/bag, 10 bags/pack, 10 packs/case
  • 100 covers per case
TM-QP258 Benefits:
  • High liquid retention: Two layers of polyester provide greater liquid-holding capacity than single-ply alternatives for solution application and appropriate liquid-pickup tasks.
  • Controlled solution delivery: Liquid-retention and release characteristics help provide consistent wetting across the cleaning surface.
  • Facility-controlled chemistry: The dry format allows users to select the compatible cleaning or disinfecting solution and saturation level required by their established procedure.
  • Compact cleaning access: The 2.5" x 8" format supports cleaning of isolators, equipment, work surfaces, pass-throughs, and other areas where larger mop systems may be difficult to maneuver.
  • Broad chemical compatibility: Polyester construction is compatible with IPA, sporicidal agents, and common cleanroom cleaning and disinfecting solutions as specified by Teknipure.
  • Spill-management capability: The absorbent 2-ply construction can support appropriate liquid-pickup and spill-control procedures.
  • Multiple hardware options: The cover can be incorporated into TekniMop™ carbon fiber or compatible stainless steel small-surface cleaning configurations.
Common Applications:
  • Cleaning isolators and RABS
  • Cleaning biosafety cabinets
  • Cleaning gloveboxes and pass-through chambers
  • Cleaning equipment surfaces, work surfaces, and benches
  • Reaching confined and difficult-to-access areas
  • Precleaning before disinfectant application
  • Residue removal
  • Application of compatible disinfectants and sanitizers
  • Controlled surface wetting
  • Spill control and appropriate liquid pickup
Best-Practice Use:
  • Select compatible hardware: Use TM-QP258 with a manufacturer-listed compatible frame or mop system, such as the TKM27 carbon fiber frame or TM-QP258-SS stainless steel system.
  • Select the appropriate chemistry: Because TM-QP258 is supplied dry, prepare and apply the compatible cleaning or disinfecting solution according to the chemistry manufacturer's instructions and facility SOP.
  • Control saturation: Wet the cover according to the procedure without unnecessary oversaturation that could cause uncontrolled dripping, pooling, or excessive solution deposition.
  • Use controlled strokes: Follow the directional wiping or mopping technique established by the facility and avoid transferring collected contamination back into previously cleaned areas.
  • Maintain surface contact: Keep the mop cover evenly engaged with the target surface and allow the polyester material and cleaning chemistry to perform the process rather than relying on excessive pressure.
  • Observe chemistry requirements: When applying a disinfectant or sanitizer, maintain the surface conditions and contact time specified by the chemistry manufacturer and facility procedure.
  • Change covers as required: Replace according to cleaning area, contamination load, solution condition, room or zone transition, damage, or other changeout requirements established by the facility.
  • Follow non-sterile material controls: TM-QP258 is supplied non-sterile and should be introduced and used according to the facility's material-transfer and contamination-control procedures.
Selection Notes (TM-QP258 vs. Other TekniMop™ Options)
  • TM-QP258: Choose this version when a dry, non-sterile 2-ply polyester cover is appropriate and the facility wants direct control over cleaning chemistry and saturation.
  • TM-QP258S: Select the sterile dry version when the cleaning procedure requires a sterile 2-ply polyester cover.
  • TM-QP70G-258: Select the non-sterile presaturated version when its factory-applied 70% IPA chemistry matches the approved cleaning procedure.
  • TM-QP70G-258S: Select the sterile 70% IPA presaturated version when both sterile presentation and that supplied chemistry are required.
  • 2.5" x 8" vs. 4" x 7": TM-QP258 provides a longer, narrower cleaning footprint than the TM-QP47 4" x 7" cover. Select the cover and compatible frame according to surface geometry, access, and required cleaning coverage.
  • Material selection: TM-QP258 uses 2-ply polyester. Microfiber, microdenier, and other TekniMop™ constructions should be selected according to their documented material, attachment, chemistry, and process requirements rather than assumed performance differences.
  • Packaging: TM-QP258 is packed 1 cover/bag, 10 bags/pack, 10 packs/case for a total of 100 covers/case. Related TekniMop™ variants use different case configurations, so always order by exact SKU.
Compatible TekniMop™ Products

Compatible Carbon Fiber Frame

  • TKM27: 2" x 7" carbon fiber flat mop frame for isolators, equipment, work surfaces, and confined cleaning areas

Compatible Stainless Steel System

  • TM-QP258-SS: 2.5" x 8" stainless steel flat mop frame with extendable handle
Building a TM-QP258 TekniMop™ System

TM-QP258 is the disposable 2-ply polyester mop-cover component of a TekniMop™ small-surface cleaning system. When building a carbon fiber configuration, pair the cover with the compatible TKM27 frame and select a compatible TekniMop™ carbon fiber handle according to the reach required for the cleaning procedure.

Carbon fiber configuration:
TM-QP258 2-Ply Polyester Mop Cover + TKM27 Carbon Fiber Frame + Compatible TekniMop™ Carbon Fiber Handle

Stainless steel configuration:
TM-QP258 2-Ply Polyester Mop Cover + TM-QP258-SS Stainless Steel Frame & Extendable Handle System

Workflow note: TM-QP258 is supplied dry and non-sterile. The facility therefore controls the cleaning chemistry and saturation level before use. Solution preparation, cover saturation, material transfer, cover changeout, and disposal should follow the applicable cleaning procedure and facility SOP.

Notes: Looking for application guidance or qualification context for the Teknipure TM-QP258 TekniMop™ 2-Ply Polyester Pocket Mop Cover? Open the SOSCleanroom Technical Vault tab above for detailed small-surface cleaning guidance, mop-cover selection, system configuration, cleaning technique, solution application, compatibility information, and additional considerations for controlled-environment mopping.

SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.

Product page updated: Nov. 3, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
2-Ply Polyester 2.5" x 8" Pocket Mop Cover Dry Non-Sterile ISO 5–8 100 Covers/Case

Teknipure TekniMop™ TM-QP258: a 2-ply polyester pocket cover for controlled liquid delivery and small-surface cleaning

The Teknipure TekniMop™ TM-QP258 is a 2.5" x 8" dry, non-sterile 2-ply polyester pocket mop cover designed for cleaning and decontamination of isolators, RABS, biological safety cabinets, gloveboxes, pass-through chambers, equipment, benches, work surfaces, and other confined critical areas. Its double-layer polyester construction is designed to provide greater liquid retention than single-ply alternatives while supporting controlled solution release and uniform surface wetting.

Operations takeaway: TM-QP258 is the dry, non-sterile base configuration of Teknipure’s 2.5" x 8" 2-ply polyester pocket-cover family. It gives the facility control over which approved cleaning or disinfecting chemistry is applied and how the cover is wetted before use.


The cover is the working contamination-control surface

In an assembled TekniMop™ system, the frame determines cleaning footprint and maneuverability, while the handle determines working reach. The mop cover is the component that directly contacts the critical surface. Cover material, solution loading, surface contact, cleaning pattern, and change-out discipline therefore have a direct influence on the cleaning process.

System principle: Frame = access and footprint. Handle = reach and leverage. Cover = direct cleaning interface. Chemistry + technique = cleaning process.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer: Teknipure
  • Product: TekniMop™ 2-Ply Polyester Pocket Mop Cover
  • Part number: TM-QP258
  • Cover size: 2.5" x 8" (6 cm x 20 cm)
  • Material: 2-ply polyester
  • Attachment style: Pocket mop cover
  • Condition: Dry
  • Sterility: Non-sterile
  • Cleanroom environment: Manufacturer lists ISO Class 5–8
  • Packaging: 1 cover/bag, 10 bags/pack, 10 packs/case
  • Total case quantity: 100 individually bagged covers/case
  • Primary carbon fiber frame: TKM27, 2" x 7"
  • Compatible stainless steel system: TM-QP258-SS, 2.5" x 8"

Configuration-control point: Teknipure specifically lists this 2.5" x 8" cover as compatible with the 2" x 7" TKM27 carbon fiber frame. The dimensional difference is part of the manufacturer-designated system and should not be treated as a sizing error.


Why 2-ply polyester: liquid retention plus controlled release

Teknipure engineers this mop-cover family around a durable 2-ply polyester construction. The manufacturer specifically identifies increased liquid retention compared with single-ply alternatives and controlled solution release for consistent surface wetting.

  • Two-layer construction: provides additional material volume for holding cleaning solution.
  • Liquid retention: supports applications where the cover must carry solution across the target surface.
  • Controlled release: helps distribute retained chemistry during the cleaning pass.
  • Uniform wetting: supports consistent application of cleaning or disinfecting solution.
  • Durable polyester: designed for demanding controlled-environment cleaning applications.
  • Spill management: increased liquid-holding capability also supports controlled pickup applications.

Process implication: Absorbency is useful only when solution loading is controlled. A dry cover that is under-wetted may not deliver sufficient chemistry, while excessive loading can increase dripping, runoff, handling weight, and uncontrolled solution transfer.


Dry configuration: facility-controlled chemistry loading

TM-QP258 is supplied dry. Unlike a presaturated mop cover, the facility determines which compatible cleaning or disinfecting solution is introduced and how much solution is loaded into the cover before use.

  • Chemistry flexibility: allows use with the facility-approved compatible cleaner or disinfectant.
  • Concentration control: chemistry concentration remains governed by the selected solution and SOP.
  • Wetness control: the facility determines the loading method and target amount of solution.
  • Process flexibility: one dry cover format can support different approved cleaning steps when the procedure permits.
  • Additional operator/process control required: dry covers do not provide the standardized liquid loading inherent to a factory-presaturated configuration.

Process-control rule: For controlled cleaning or disinfection, define the chemistry, concentration, cover-wetting method, target wetness, surface coverage, required contact time, and cover change-out point in the SOP.


Non-sterile status: do not confuse cleanroom compatibility with sterility

TM-QP258 is supplied non-sterile. Its cleanroom positioning and controlled-environment construction do not make the cover sterile or interchangeable with the sterile TM-QP258S configuration.

Sterility control: If the cleaning procedure requires a sterile mop cover, select the manufacturer-designated sterile configuration rather than treating TM-QP258 as equivalent based on material or appearance.


ISO 5–8 positioning: application fit still depends on the complete process

Teknipure lists TM-QP258 for ISO Class 5–8 cleanroom environments. Typical industries identified by the manufacturer include pharmaceutical and biologics manufacturing, medical device and optics, semiconductor and microelectronics, aerospace and defense, compounding pharmacies, laboratories, and academia.

Qualification point: The manufacturer’s ISO environment listing does not independently qualify the cover for every process conducted within those classifications. Final suitability depends on the specific cover SKU, chemistry, surface, mop hardware, cleaning method, sterility requirement, and facility SOP.


TKM27 compatibility: 2.5" x 8" cover on a 2" x 7" frame

Teknipure explicitly lists the TKM27 2" x 7" carbon fiber flat mop frame as compatible with TM-QP258. The cover’s 2.5" x 8" dimensions provide the material required to fit over the smaller underlying frame and form the working cleaning surface.

  • Frame: TKM27 carbon fiber flat mop frame, 2" x 7"
  • Cover: TM-QP258 2-ply polyester pocket mop cover, 2.5" x 8"
  • System positioning: compact small-surface and isolator cleaning
  • Handle choice: select independently according to required reach and operator control

Configuration principle: Cover dimensions do not need to exactly duplicate frame dimensions. Use the manufacturer-designated cover/frame combination rather than matching products by nominal dimensions alone.


Stainless steel system compatibility

Teknipure also lists TM-QP258 as compatible with the TM-QP258-SS stainless steel 2.5" x 8" flat mop frame and extendable handle system. This allows the same cover format to support either Teknipure’s compact carbon fiber system or the designated stainless steel hardware platform.

Hardware-selection point: The cleaning cover determines the direct surface interface, while hardware selection should be based on requirements such as geometry, reach, weight, sterilization procedure, and facility standardization.


Chemistry compatibility & solution delivery

Teknipure describes the 2-ply polyester cover as compatible with IPA, sporicidal products, and common cleanroom disinfectants and cleaning solutions. The material is designed to retain and release liquid while supporting controlled-environment cleaning.

  • IPA: supports alcohol-based cleaning applications when approved by the facility.
  • Sporicidal chemistry: suitable for use with compatible sporicidal cleaning solutions.
  • Cleanroom disinfectants: supports common controlled-environment disinfectant application.
  • Cleaning solutions: dry format allows the facility to select the approved compatible chemistry.

Chemical-control rule: Broad compatibility should not be interpreted as universal compatibility. Validate the specific chemistry, concentration, contact time, target surface, and facility process before routine use.


Uniform surface wetting: why liquid release matters during disinfection

Teknipure specifically identifies liquid retention and controlled release as features of its 2-ply polyester construction. For disinfectant application, this matters because the mop cover must carry solution to the surface and distribute it across the cleaning path.

  • Initial loading: the cover must receive enough solution to begin the cleaning process at the defined wetness level.
  • Release during use: retained solution should transfer to the surface as the cover moves through the cleaning pattern.
  • Coverage consistency: declining wetness can change solution delivery as cleaning progresses.
  • Contact time: disinfectant effectiveness depends on meeting the chemistry manufacturer’s required wet contact conditions.

Important: A mop cover can help distribute chemistry, but it does not establish disinfectant efficacy. Follow the approved disinfectant label, required concentration, wet contact time, and facility cleaning procedure.


What TM-QP258 is designed to support (typical use cases)
  • Cleaning isolators and RABS
  • Cleaning biological safety cabinets
  • Cleaning gloveboxes and pass-through chambers
  • Cleaning equipment surfaces, work surfaces, and benches
  • Reaching confined and difficult-to-access areas with compatible mop hardware
  • Precleaning before disinfectant application
  • Application of compatible disinfectants and sanitizers
  • Removal of process residues
  • Controlled spill management

Cleaning technique: use the cover to remove contamination, not redistribute it

A clean mop cover provides a controlled surface for contamination removal and chemistry application. As the cover collects residues, particles, microorganisms, and process soils, continued use can eventually transfer accumulated contamination rather than continue removing it efficiently.

  • Begin with a properly prepared cover: use the approved wetting method and chemistry.
  • Follow a defined progression: move from cleaner toward less-clean areas where applicable.
  • Use controlled overlapping passes: maintain complete surface coverage without random scrubbing.
  • Avoid unnecessary backtracking: do not repeatedly move a loaded cover across previously treated surfaces.
  • Respect zoning: change covers where required when transitioning between defined cleaning areas.
  • Monitor wetness: replace or reprepare according to the SOP when the cover can no longer maintain the required solution delivery.

Contamination-control principle: A clean cover removes contamination. An overloaded cover can move contamination. Define the transition point in the cleaning procedure rather than leaving cover change-out entirely to operator judgment.


Best-practice use (dry 2-ply polyester pocket cover)
  1. Verify the SKU: confirm TM-QP258 when the procedure requires the dry, non-sterile 2.5" x 8" configuration.
  2. Inspect packaging: do not introduce visibly damaged or compromised packaging into the controlled process.
  3. Use designated hardware: install the cover on the manufacturer-approved TKM27 or compatible 2.5" x 8" stainless steel system.
  4. Load approved chemistry: wet the cover using the facility-defined method, concentration, and target amount.
  5. Confirm fit: ensure the pocket cover is properly seated and retained on the frame.
  6. Use controlled passes: follow the defined cleaning direction and overlap.
  7. Maintain required wetness: when disinfecting, deliver enough chemistry to support the required wet contact conditions.
  8. Do not overextend cover use: change the cover at the defined contamination, area, zoning, wetness, or process trigger.
  9. Avoid cross-contamination: do not move a used cover into another controlled zone unless specifically permitted by the SOP.
  10. Dispose or handle after use according to procedure: follow facility requirements based on the chemistry and contamination encountered.

2.5" x 8" 2-ply polyester family: do not substitute by appearance
  • TM-QP258: dry, non-sterile — facility-controlled chemistry loading
  • TM-QP70G-258: non-sterile, presaturated with 70% IPA — factory-controlled IPA delivery
  • TM-QP258S: dry, sterile — sterile cover with facility-controlled chemistry loading
  • TM-QP70G-258S: sterile, presaturated with 70% IPA — combines sterile status with ready-to-use IPA saturation

Configuration-control rule: Dry, presaturated, sterile, and non-sterile versions may share the same basic size and 2-ply polyester architecture, but they are not operationally interchangeable when the SOP specifies a particular sterility status or chemistry-delivery method.


Packaging architecture: individually bagged covers inside case packs
  • Primary quantity: 1 cover/bag
  • Pack quantity: 10 bags/pack
  • Case quantity: 10 packs/case
  • Total: 100 covers/case

Inventory implication: Individually bagged covers allow operators to introduce individual units as required rather than opening a bulk package containing the entire case quantity. Follow the facility’s material-transfer and packaging-removal procedure when moving product into controlled areas.


Misuse controls & selection cautions
  • Do not treat TM-QP258 as sterile: this SKU is supplied non-sterile.
  • Do not assume dry and presaturated versions are interchangeable: solution loading and process controls differ.
  • Do not choose a cover by dimensions alone: use the manufacturer-designated frame/cover combination.
  • Do not assume “low particulate” means particle-free or lint-free: all textile cleaning materials can contribute some fibers or particles.
  • Do not improvise chemistry loading: define the wetting method where cleaning or disinfection is controlled.
  • Do not continue using an overloaded cover: change at the facility-defined contamination or coverage trigger.
  • Do not assume broad chemical compatibility means universal resistance: verify the specific chemistry and exposure conditions.
  • Do not infer reuse: follow the facility procedure and current manufacturer instructions for handling after use rather than assuming a disposable cover can be laundered or reprocessed.

TM-QP258 selection logic
  • Choose TM-QP258 when: a dry, non-sterile 2-ply polyester pocket cover is required for compact controlled-environment cleaning.
  • Choose it when chemistry flexibility matters: the facility wants to apply its own approved compatible cleaning or disinfecting solution.
  • Choose TM-QP70G-258 instead when: factory-presaturated 70% IPA is preferred for standardized ready-to-use solution delivery.
  • Choose TM-QP258S instead when: the process requires a sterile dry cover.
  • Choose TM-QP70G-258S instead when: both sterile status and factory-controlled 70% IPA saturation are required.
  • Pair with TKM27 when: using Teknipure’s compact carbon fiber hardware system.
  • Pair with TM-QP258-SS when: the facility uses Teknipure’s designated 2.5" x 8" stainless steel frame/handle system.

Simple decision rule: Choose the cover by sterility requirement + chemistry-delivery method first, then confirm the compatible hardware and cleaning procedure.


Why source TekniMop™ through SOSCleanroom
  • System-level selection: SOSCleanroom can help align the cover configuration with the appropriate TekniMop™ frame, handle, and cleaning chemistry.
  • Exact-SKU control: We can help distinguish between dry, presaturated, sterile, and non-sterile versions that may otherwise appear very similar.
  • Consumable continuity: Standardizing the exact mop-cover SKU helps maintain a repeatable cleaning process across purchasing cycles.
  • Documentation support: We can help customers identify current Teknipure technical documentation for purchasing, qualification, and SOP review.
  • One-cart procurement: Source TekniMop™ covers and hardware alongside disinfectants, IPA, gloves, wipers, and other critical-environment consumables.

Manufacturer documentation (authoritative references)
  • Teknipure TM-QP258 product information
  • TekniMop™ Small Surface & Isolator Cleaning Tools Technical Data Sheet

Documentation note: Use current manufacturer documentation, exact product labeling, and applicable lot records for final purchasing, qualification, and receiving decisions.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.