Skip to main content

Teknipure TM-QP258S TekniMop 2Ply Sterile Polyester Pocket Mop Cover, 2.5″ x 8″ (Refills) (Case Qty.)

$344.76
SKU: TM-QP258S CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout
Type:
Dry Mop
Sterile:
Yes

Teknipure TM-QP258S TekniMop 2Ply Sterile Polyester Pocket Mop Cover, 2.5″ x 8″ (Refills) (Case Qty.) - SOSCleanroom Standard Specification

The Teknipure TM-QP258S TekniMop™ Sterile 2-Ply Polyester Pocket Mop Cover is a dry, sterile cleanroom mop cover designed for small-surface and isolator cleaning applications. Its durable 2-ply polyester construction provides enhanced liquid retention and controlled solution release for consistent surface wetting, disinfectant application, residue removal, and spill control. Supplied sterile but dry, TM-QP258S allows facilities to select and control the cleaning chemistry and saturation level required by their established cleaning procedures.

Sterile cover with facility-controlled chemistry: TM-QP258S combines a compact 2.5" x 8" pocket format with 2-ply polyester construction and gamma-irradiated sterility. The cover is validated to a sterility assurance level (SAL) of 10-6 according to AAMI guidelines while remaining dry, allowing the facility to apply the cleaning or disinfecting chemistry required by its procedure.

Specifications:
  • Part Number: TM-QP258S
  • Product Type: Sterile pocket mop cover
  • Size: 2.5" x 8"
  • Material: 2-ply polyester
  • Format: Dry
  • Sterility: Sterile
  • Sterilization Method: Gamma irradiation
  • Sterility Assurance Level: SAL 10-6
  • Sterility Validation: Validated according to AAMI guidelines
  • Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
  • Packaging: 1 cover/bag, 24 bags/pack, 12 packs/case
  • Total Case Quantity: 288 covers/case
  • Compatible Carbon Fiber Frame: TKM27
  • Compatible Stainless Steel System: TM-QP258-SS 2.5" x 8" flat mop frame and extendable handle
Where TM-QP258S Fits in Controlled Environments

TM-QP258S is designed for sterile small-surface cleaning applications where facilities require a sterile mop cover while retaining control over the cleaning or disinfecting chemistry applied at the point of use. Its compact format supports controlled cleaning of isolators, RABS/BSC areas, gloveboxes, pass-through chambers, equipment, work surfaces, benches, and other confined or difficult-to-access areas.

The 2-ply polyester construction provides increased liquid retention compared with single-ply alternatives while supporting controlled release of cleaning solution across the target surface. This combination is useful for procedures requiring uniform wetting, disinfectant application, residue removal, or liquid pickup.

Typical program fit: Sterile isolator and RABS/BSC cleaning, gloveboxes, pass-through chambers, equipment and work surfaces, benches, confined areas, precleaning, residue removal, disinfectant and sanitizer application, controlled surface wetting, and spill control.

Because TM-QP258S is supplied sterile and dry, facilities can select the appropriate compatible chemistry and establish the required saturation level according to their validated cleaning procedure rather than relying on a predetermined presaturated solution.

About the Manufacturer:

Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, interchangeable handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, compounding pharmacies, laboratories, and other controlled environments.

Within the TekniMop™ small-surface system, Teknipure offers dry, presaturated, sterile, and non-sterile 2-ply polyester mop-cover configurations. This allows facilities to select a format according to cleaning chemistry, sterility requirements, solution-delivery preferences, contamination-control objectives, and established procedures.

TM-QP258S Features:
  • Durable 2-ply polyester construction
  • 2.5" x 8" pocket-style format for small-surface cleaning
  • Gamma irradiated for sterile cleaning applications
  • Sterility assurance level (SAL) of 10-6
  • Sterility validated according to AAMI guidelines
  • Dry format allows facility-controlled chemistry selection and saturation
  • Enhanced liquid retention compared with single-ply alternatives
  • Controlled liquid release for consistent surface wetting
  • Compatible with IPA, sporicidal agents, and common cleanroom disinfectants and cleaning solutions
  • Designed for low particulate generation in controlled environments
  • Compatible with the TKM27 TekniMop™ carbon fiber flat mop frame
  • Compatible with the TM-QP258-SS stainless steel 2.5" x 8" mop system
TM-QP258S Benefits:
  • Sterility assurance: Gamma irradiation to an SAL of 10-6 supports cleaning programs requiring sterile consumables.
  • Facility-controlled chemistry: The dry format allows users to select the cleaning or disinfecting solution appropriate for the procedure rather than being limited to a factory-presaturated chemistry.
  • Controlled solution delivery: 2-ply polyester construction provides strong liquid retention with controlled release for consistent surface wetting.
  • Enhanced absorbency: The two-layer construction provides increased liquid-holding capacity for disinfectant application, residue removal, and spill-control procedures.
  • Compact cleaning access: The 2.5" x 8" format supports cleaning of isolators, equipment, work surfaces, pass-throughs, and other areas where larger mop systems may be difficult to maneuver.
  • Broad chemical compatibility: Polyester construction is compatible with IPA, sporicidal agents, and common cleanroom disinfectants and cleaning solutions as specified by Teknipure.
  • Flexible sterile cleaning: Combines sterile presentation with the flexibility of a dry cover, making it suitable for facilities using multiple validated cleaning chemistries.
  • Multiple hardware options: TM-QP258S can be incorporated into compatible carbon fiber or stainless steel TekniMop™ small-surface cleaning configurations.
Common Applications:
  • Sterile isolator cleaning
  • RABS/BSC cleaning
  • Cleaning gloveboxes and pass-through chambers
  • Cleaning equipment surfaces, work surfaces, and benches
  • Reaching confined and difficult-to-access areas
  • Precleaning before disinfectant application
  • Residue removal
  • Application of disinfectants and sanitizers
  • Controlled surface wetting
  • Spill control and liquid pickup
Best-Practice Use:
  • Select compatible hardware: Use TM-QP258S with a manufacturer-listed compatible frame or mop system, such as the TKM27 carbon fiber frame or TM-QP258-SS stainless steel system.
  • Maintain sterile handling: Open and introduce the individually packaged sterile cover according to the facility's established material-transfer, aseptic handling, and contamination-control procedures.
  • Select the appropriate chemistry: Because TM-QP258S is supplied dry, prepare and apply the cleaning or disinfecting solution according to the chemistry manufacturer's instructions and facility SOP.
  • Control saturation: Wet the cover according to the validated procedure without unnecessary oversaturation that could cause uncontrolled dripping or excessive solution deposition.
  • Use controlled strokes: Follow the directional wiping or mopping technique established by the facility and avoid transferring contamination back into previously cleaned areas.
  • Maintain surface contact: Keep the mop cover evenly engaged with the target surface to support consistent solution delivery and mechanical cleaning action.
  • Observe required contact time: When applying a disinfectant or sanitizer, maintain the surface conditions and contact time specified by the chemistry manufacturer and facility procedure.
  • Change covers as required: Replace the mop cover according to cleaning area, contamination load, room transition, chemistry condition, or other changeout criteria established by the facility.
Selection Notes (TM-QP258S vs. Other TekniMop™ Options)
  • TM-QP258S: Choose this version when a sterile, dry 2-ply polyester cover is required and the facility needs control over cleaning chemistry and saturation.
  • TM-QP258: Select the dry, non-sterile version when sterile presentation is not required.
  • TM-QP70G-258: Select the non-sterile presaturated version when a ready-to-use 70% IPA format is preferred.
  • TM-QP70G-258S: Select the sterile presaturated version when both sterile presentation and ready-to-use 70% IPA saturation are required.
  • Dry sterile vs. presaturated sterile: TM-QP258S provides greater chemistry flexibility because the facility controls the solution applied to the cover. A sterile presaturated option can reduce preparation steps when its supplied chemistry matches the validated procedure.
  • 2-ply polyester vs. microfiber or microdenier: 2-ply polyester emphasizes liquid retention, controlled solution delivery, durability, and low particulate generation. Alternative TekniMop™ materials may be selected when different surface-contact or contamination-removal characteristics are required.
Compatible TekniMop™ Products

Compatible Carbon Fiber Frame

  • TKM27: 2" x 7" carbon fiber flat mop frame for isolators, equipment, work surfaces, and confined cleaning areas

Compatible Stainless Steel System

  • TM-QP258-SS: 2.5" x 8" stainless steel flat mop frame with extendable handle
Building a TM-QP258S TekniMop™ System

The TM-QP258S is the sterile disposable mop-cover component of a TekniMop™ small-surface cleaning system. When building a carbon fiber configuration, pair the cover with the compatible TKM27 frame and select a compatible TekniMop™ carbon fiber handle according to the reach required for the cleaning procedure.

Carbon fiber configuration:
TM-QP258S Sterile 2-Ply Polyester Mop Cover + TKM27 Carbon Fiber Frame + Compatible TekniMop™ Carbon Fiber Handle

Stainless steel configuration:
TM-QP258S Sterile 2-Ply Polyester Mop Cover + TM-QP258-SS Stainless Steel Frame & Extendable Handle System

Workflow note: TM-QP258S is supplied sterile and dry. The facility therefore maintains control over the cleaning chemistry and saturation level while receiving a gamma-irradiated sterile mop cover. Sterile material transfer, opening, saturation, use, cover changeout, and disposal should follow the applicable validated cleaning procedure and facility SOP.

Notes: Looking for application guidance or qualification context for the Teknipure TM-QP258S TekniMop™ Sterile 2-Ply Polyester Pocket Mop Cover? Open the SOSCleanroom Technical Vault tab above for detailed sterile small-surface cleaning guidance, mop-cover selection, system configuration, cleaning technique, chemistry application, compatibility information, and additional considerations for controlled-environment mopping.

SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.

Product page updated: Oct. 26, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.

The Technical Vault By SOSCleanroom
Sterile SAL 10-6 Gamma Irradiated 2-Ply Polyester 2.5" x 8" Dry Pocket Cover ISO 5–8

Teknipure TekniMop™ TM-QP258S: a sterile dry 2-ply polyester pocket cover for aseptic and critical cleaning applications

The Teknipure TekniMop™ TM-QP258S is a sterile, dry 2.5" x 8" 2-ply polyester pocket mop cover engineered for pharmaceutical, biotech, compounding, laboratory, and other critical cleaning applications where a sterile cleaning interface is required. Teknipure gamma irradiates the product to a sterility assurance level (SAL) of 10-6 and validates sterility according to AAMI guidelines.

Operations takeaway: TM-QP258S combines a sterile starting condition with dry chemistry flexibility. The cover arrives sterile, while the facility retains control over which approved compatible cleaning or disinfecting solution is applied before use.


The cover is the sterile surface-contact component

In an assembled TekniMop™ system, the frame determines footprint and maneuverability, while the handle determines reach and leverage. TM-QP258S is the component that directly contacts the critical surface. Its sterile status, material construction, chemistry loading, surface contact, cleaning pattern, and change-out discipline therefore become important elements of the contamination-control process.

System principle: Frame = access and footprint. Handle = reach and leverage. Cover = sterile cleaning interface. Chemistry + technique = cleaning process.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Manufacturer: Teknipure
  • Product: TekniMop™ Sterile 2-Ply Polyester Pocket Mop Cover
  • Part number: TM-QP258S
  • Cover size: 2.5" x 8"
  • Material: 2-ply polyester
  • Attachment style: Pocket mop cover
  • Condition: Dry
  • Sterility: Sterile
  • Sterilization method: Gamma irradiation
  • Sterility assurance level: SAL 10-6
  • Sterility validation: Manufacturer states validation according to AAMI guidelines
  • Cleanroom environment: Manufacturer lists ISO Class 5–8
  • Packaging: 1 cover/bag, 24 bags/pack, 12 packs/case
  • Total case quantity: 288 individually bagged covers/case
  • Compatible carbon fiber frame: TKM27, 2" x 7"
  • Compatible stainless steel system: TM-QP258-SS, 2.5" x 8"

Configuration-control point: Sterility is SKU-specific. TM-QP258S should not be substituted with the visually similar non-sterile TM-QP258 when the procedure requires a sterile mop cover.


Sterility assurance: gamma irradiated to SAL 10-6

Teknipure states that TM-QP258S is gamma irradiated to a sterility assurance level of 10-6 and validated for sterility according to AAMI guidelines. This provides a defined sterile configuration for applications where the cleaning consumable itself must enter the process with a manufacturer-established sterile status.

  • Gamma irradiated: sterilization is performed as part of the manufactured product configuration.
  • SAL 10-6: provides a defined manufacturer-stated sterility assurance level.
  • AAMI validation: Teknipure states the product is validated for sterility according to AAMI guidelines.
  • Sterile SKU control: the “S” configuration distinguishes TM-QP258S from the non-sterile TM-QP258.

Important distinction: Sterile does not mean permanently sterile after opening or handling. Maintaining the sterile condition through material transfer, package opening, installation, and use depends on the facility’s approved aseptic handling procedure.


Individually bagged sterile covers: packaging supports controlled introduction

TM-QP258S is packaged one sterile cover per bag, with 24 bags per pack and 12 packs per case. This provides 288 individually bagged sterile covers per case and allows individual units to be introduced into the cleaning process without opening a bulk package containing multiple exposed mop covers.

  • 1 cover/bag: isolates each sterile consumable before use.
  • 24 bags/pack: provides organized intermediate packaging.
  • 12 packs/case: supports bulk inventory management.
  • 288 covers/case: total manufacturer packaging quantity.
  • Individual introduction: supports controlled transfer of only the quantity required for the cleaning operation.

Aseptic-handling point: Individual packaging supports controlled introduction, but packaging alone does not establish an aseptic transfer procedure. Follow the facility’s approved material-transfer, disinfection, opening, and handling method.


Dry + sterile: separating sterility from chemistry selection

TM-QP258S is supplied sterile but dry. This is an important process distinction: Teknipure establishes the sterile condition of the cover, while the facility determines which compatible cleaning or disinfecting chemistry is introduced during use.

  • Sterile starting condition: the cover arrives as a manufacturer-designated sterile product.
  • Chemistry flexibility: the dry format allows selection of an approved compatible cleaning or disinfecting solution.
  • Facility-controlled loading: the SOP determines how the selected chemistry is applied to the cover.
  • Process flexibility: useful where a sterile cover is required but factory-presaturated 70% IPA is not the desired chemistry configuration.

Critical control: If maintaining a sterile process is required, the chemistry, chemistry container, wetting method, handling technique, mop hardware, and transfer procedure must also be appropriate to that process. A sterile dry cover cannot make an otherwise uncontrolled preparation step sterile.


2-ply polyester construction: liquid retention and controlled release

Teknipure describes the durable 2-ply polyester construction as providing greater liquid retention than single-ply alternatives. The cover is designed to retain cleaning or disinfecting solution and release it across the target surface for uniform wetting.

  • Two-layer construction: provides additional material volume for solution retention.
  • Enhanced absorbency: supports high-volume disinfectant application and spill-control tasks.
  • Liquid retention: carries chemistry within the cleaning interface during use.
  • Controlled release: supports transfer of retained solution to the target surface.
  • Uniform wetting: Teknipure identifies consistent disinfectant coverage as a benefit of the material.

Process implication: High liquid retention is useful only when the loading method is controlled. The SOP should define enough solution to achieve the required coverage without creating unnecessary dripping, runoff, or excess liquid.


Broad chemistry compatibility: flexibility for sterile cleaning programs

Teknipure identifies TM-QP258S as compatible with IPA, sporicidal products, common cleanroom disinfectants, and cleaning solutions. The manufacturer states that the polyester construction supports these chemistries without degrading or shedding excessive particulate contamination under intended use conditions.

  • IPA: can be facility-applied when the approved procedure calls for alcohol-based cleaning.
  • Sporicidal products: supports compatible sporicidal cleaning steps.
  • Cleanroom disinfectants: can support facility-selected compatible disinfectant application.
  • Cleaning solutions: dry format provides flexibility where another approved chemistry is required.

Chemical-control rule: Broad compatibility does not mean universal compatibility. Verify the specific chemistry, concentration, target surface, exposure conditions, contact time, and facility procedure.


Uniform surface wetting: sterility does not replace solution-delivery control

Sterile status controls one important variable, but effective chemistry application still requires appropriate solution loading and surface coverage. Teknipure specifically identifies liquid retention and controlled release as features intended to support consistent disinfectant coverage.

  • Define the loading method: establish how the dry sterile cover receives the approved chemistry.
  • Define target wetness: ensure enough solution is available for the intended surface area.
  • Maintain coverage: use a repeatable pass pattern with appropriate overlap.
  • Monitor solution delivery: wetness decreases as chemistry transfers from the cover to the surface.
  • Respect contact requirements: follow the disinfectant manufacturer’s required use conditions and facility procedure.

Process-control rule: For validated cleaning or disinfection, define the chemistry, concentration, sterile wetting method, target wetness, surface coverage, required contact time, and cover change-out point.


ISO 5–8 positioning: sterile configuration for critical environments

Teknipure lists TM-QP258S for ISO Class 5–8 environments and specifically positions the product for sterile pharmaceutical and biotech cleanroom applications. Other manufacturer-listed industries include medical device and optics, compounding pharmacies, laboratories, and academia.

Qualification point: Sterility and the manufacturer’s ISO environment listing do not independently qualify TM-QP258S for every process within those environments. Final suitability depends on the cover, chemistry, hardware, surface, transfer method, cleaning procedure, and facility contamination-control requirements.


Frame compatibility: sterile cover, reusable hardware system

Teknipure specifically lists TM-QP258S as compatible with its carbon fiber and stainless steel mop systems, including the TKM27 2" x 7" carbon fiber frame and the TM-QP258-SS 2.5" x 8" stainless steel flat mop system.

  • TKM27: 2" x 7" carbon fiber flat mop frame
  • TM-QP258-SS: 2.5" x 8" stainless steel flat mop frame and extendable handle system
  • TM-QP258S: 2.5" x 8" sterile pocket mop cover
  • Carbon fiber handle: selected independently according to required reach when using TKM27

System-control point: A sterile cover does not automatically make reusable mop hardware sterile. Where sterile hardware is required at point of use, process the frame and handle according to the facility-approved cleaning, sterilization, transfer, and assembly procedure.


What TM-QP258S is designed to support (typical use cases)
  • Cleaning isolators and RABS
  • Cleaning biological safety cabinets
  • Cleaning gloveboxes and pass-through chambers
  • Cleaning equipment surfaces, work surfaces, and benches
  • Reaching confined and difficult-to-access areas with compatible mop hardware
  • Precleaning before disinfectant applications
  • Application of compatible disinfectants and sanitizers
  • Removal of process residues
  • Spill-control applications
  • Sterile pharmaceutical and biotech cleaning applications where a dry sterile mop cover is appropriate

Aseptic handling: protecting the sterile starting condition

TM-QP258S arrives as a sterile consumable, but its sterile status must be protected as the product moves from packaged inventory into the actual cleaning process. Transfer and handling controls should be defined according to the facility’s contamination-control strategy.

  • Inspect the package: confirm packaging integrity before use.
  • Verify identification: confirm the correct sterile SKU and required lot/expiration information according to facility procedure.
  • Follow material-transfer controls: introduce the packaged product according to the facility’s approved transfer method.
  • Open at the defined stage: avoid exposing the sterile cover earlier than required.
  • Control handling: prevent contact with uncontrolled surfaces during removal and installation.
  • Use qualified hardware: ensure reusable frame and handle preparation matches the sterility requirements of the process.

Sterility principle: The sterile package establishes the starting condition. The facility’s transfer and handling procedure determines whether that condition is protected through point of use.


Cleaning technique: sterile does not mean unlimited use

Once TM-QP258S enters use, it begins collecting contamination from the surfaces it contacts. Sterile status at package opening does not mean the same cover should continue indefinitely across multiple surfaces or cleaning zones.

  • Begin with the properly prepared sterile cover: load chemistry according to the approved procedure.
  • Progress systematically: move from cleaner toward less-clean areas where applicable.
  • Use controlled overlapping passes: maintain complete surface coverage.
  • Avoid unnecessary backtracking: limit movement of a loaded cover over previously treated areas.
  • Respect zoning: use a fresh cover where the SOP requires a consumable change between zones.
  • Monitor loading: change the cover when contamination, residue, wetness, or coverage reaches the defined process limit.

Contamination-control principle: A cover can begin sterile and still become contaminated during use. Sterility at opening does not replace a defined change-out strategy.


Best-practice use (sterile dry pocket cover)
  1. Verify the SKU: confirm TM-QP258S when the procedure requires the dry sterile 2.5" x 8" configuration.
  2. Inspect package integrity: do not use a sterile cover from visibly damaged or compromised packaging.
  3. Confirm lot and expiration controls: follow facility receiving and material-use requirements.
  4. Transfer according to procedure: follow the approved material-transfer process before opening.
  5. Prepare reusable hardware: ensure the frame and handle meet the cleaning or sterilization requirements of the process.
  6. Open and install aseptically: minimize uncontrolled contact while fitting the pocket cover to the frame.
  7. Apply approved chemistry: wet the dry sterile cover using the defined chemistry, method, and target loading.
  8. Use controlled passes: maintain cleaning direction, overlap, zoning, and surface sequence.
  9. Change at the defined trigger: replace according to contamination loading, coverage area, zone transition, wetness, or other SOP criteria.
  10. Handle after use according to procedure: follow facility requirements for disposal and the contamination encountered.

2.5" x 8" 2-ply polyester family: where TM-QP258S fits
  • TM-QP258: dry, non-sterile — facility-controlled chemistry without a sterile starting condition
  • TM-QP70G-258: 70% IPA, non-sterile — factory-controlled IPA loading without a sterile designation
  • TM-QP258S: dry, sterile — sterile starting condition with facility-controlled chemistry loading
  • TM-QP70G-258S: 70% IPA, sterile — sterile starting condition plus factory-controlled IPA presaturation

Selection logic: TM-QP258S occupies a very specific position: sterility is controlled by the manufacturer, while chemistry selection and loading remain under facility control.


TM-QP258S vs. TM-QP70G-258S: sterile dry or sterile presaturated?
  • Choose TM-QP258S when: the procedure requires a sterile cover but the facility needs to select or apply the chemistry.
  • Choose TM-QP70G-258S when: the procedure requires both a sterile cover and ready-to-use 70% IPA presaturation.
  • Dry sterile advantage: greater chemistry flexibility.
  • Presaturated sterile advantage: removes the manual IPA-loading step and standardizes the cover’s starting chemistry condition.

Do not substitute by convenience: Select the configuration specified by the cleaning process. Sterile dry and sterile IPA-presaturated covers solve different process-control requirements.


Change-out triggers: controlling contamination after opening
  • Defined coverage limit: the procedure assigns a maximum surface area or cleaning zone per cover.
  • Zone transition: a fresh sterile cover is required before entering another defined cleaning area.
  • Visible contamination: the working surface accumulates obvious soil or process residue.
  • Insufficient solution delivery: the cover can no longer maintain the wetness required by the cleaning step.
  • Compromised handling: the cover contacts an uncontrolled surface or is otherwise considered contaminated.
  • Physical damage: the cover is torn, compromised, or no longer retained correctly on the frame.
  • Process transition: a different chemistry or cleaning step requires a fresh consumable.

Key distinction: Sterility is a starting-state specification. Change-out decisions during cleaning are driven by what happens to the cover after it enters the process.


Misuse controls & selection cautions
  • Do not confuse sterile with presaturated: TM-QP258S is sterile but supplied dry.
  • Do not substitute TM-QP258: the non-sterile version does not provide the same manufacturer-established sterile starting condition.
  • Do not assume sterile packaging protects the cover after opening: use approved aseptic handling practices.
  • Do not assume sterile cover = sterile assembled mop: reusable hardware must meet the process requirements separately.
  • Do not improvise chemistry loading: define the chemistry, concentration, wetting method, and target loading in controlled processes.
  • Do not use damaged sterile packaging: follow facility procedures for compromised packages.
  • Do not choose the cover by dimensions alone: use manufacturer-designated hardware compatibility.
  • Do not interpret cleanroom-compatible polyester as particle-free or lint-free: textile consumables can still release some fibers or particles.
  • Do not overextend cover use: replace at the defined contamination, coverage, zoning, or wetness trigger.

TM-QP258S selection logic
  • Choose TM-QP258S when: the process requires a sterile 2.5" x 8" 2-ply polyester pocket mop cover supplied dry.
  • Choose it when chemistry flexibility matters: the facility needs a sterile cover but wants to control the cleaning or disinfecting chemistry.
  • Choose it for aseptic applications when: the validated procedure calls for a sterile cleaning consumable and compatible reusable mop hardware.
  • Choose TM-QP258 instead when: a non-sterile dry cover is appropriate.
  • Choose TM-QP70G-258 instead when: non-sterile ready-to-use 70% IPA is required.
  • Choose TM-QP70G-258S instead when: both sterility and factory-controlled 70% IPA presaturation are required.
  • Pair with TKM27 when: using Teknipure’s compact carbon fiber hardware platform.
  • Pair with TM-QP258-SS when: using Teknipure’s designated stainless steel mop system.

Simple decision rule: If the SOP requires sterile + dry + compact pocket mop, TM-QP258S provides the sterile cleaning interface while leaving chemistry selection under facility control.


Why source TekniMop™ through SOSCleanroom
  • Exact-SKU selection: SOSCleanroom can help distinguish between dry, presaturated, sterile, and non-sterile TekniMop™ configurations that may otherwise appear very similar.
  • Sterile-process awareness: We can help customers identify the appropriate manufacturer-designated sterile cover while keeping hardware and chemistry requirements clearly separated.
  • System-level support: We can help align the cover with the appropriate frame, handle, cleaning chemistry, and application.
  • Documentation support: We can help customers identify current manufacturer technical documentation and lot-specific certificates for purchasing, qualification, and SOP review.
  • One-cart procurement: Source TekniMop™ covers and hardware alongside sterile IPA, disinfectants, gloves, wipers, and other critical-environment consumables.

Manufacturer documentation & lot records

Documentation hierarchy: For qualification and lot-specific sterile-product records, use the current manufacturer technical documentation, product labeling, and applicable lot-specific certificate rather than relying solely on generalized product-family information.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.