Teknipure TM-QP70G-258S TekniMop Sterile 2Ply Polyester Pocket Mop Cover, 2.5″ x 8″, 70% IPA (Refills) (Case Qty.) - SOSCleanroom Standard Specification
The Teknipure TM-QP70G-258S TekniMop™ Sterile 2-Ply Polyester Pocket Mop Cover is a ready-to-use sterile cleanroom mop cover presaturated with 70% isopropyl alcohol (IPA). Designed for small-surface and isolator cleaning, its durable 2-ply polyester construction provides reliable liquid retention and controlled solution release while factory presaturation supports consistent IPA delivery without manual measuring, spraying, or saturation before use.
Sterile + ready-to-use 70% IPA: TM-QP70G-258S combines gamma-irradiated sterility with standardized 70% IPA presaturation in a compact 2.5" x 8" pocket mop cover. Sterility is validated to a sterility assurance level (SAL) of 10-6 according to AAMI guidelines, while resealable gusset packaging helps minimize IPA evaporation and maintain consistent mop saturation.
Specifications:
- Part Number: TM-QP70G-258S
- Product Type: Sterile presaturated pocket mop cover
- Size: 2.5" x 8"
- Material: 2-ply polyester
- Solution: 70% isopropyl alcohol (IPA)
- Format: Presaturated
- Sterility: Sterile
- Sterilization Method: Gamma irradiation
- Sterility Assurance Level: SAL 10-6
- Sterility Validation: Validated according to AAMI guidelines
- Cleanroom Environment: Designed for applications in ISO Class 5–8 environments as specified by Teknipure
- Packaging: 5 covers/resealable gusset bag, 12 bags/case
- Total Case Quantity: 60 covers/case
- Compatible Carbon Fiber Frame: TKM27
- Compatible Stainless Steel System: TM-QP258-SS 2.5" x 8" flat mop frame and extendable handle
Where TM-QP70G-258S Fits in Controlled Environments
TM-QP70G-258S is designed for sterile small-surface cleaning applications where a ready-to-use 70% IPA format supports standardized solution delivery and eliminates manual IPA preparation at the point of use. Its compact profile is well suited to isolators, RABS/BSC areas, gloveboxes, pass-through chambers, equipment surfaces, work surfaces, benches, and other confined or difficult-to-access areas.
The 2-ply polyester construction provides reliable liquid retention while releasing solution across the target surface during cleaning. Factory presaturation helps maintain consistent IPA wetness from cover to cover, while sterile presentation supports procedures requiring sterile cleaning consumables.
Typical program fit: Sterile isolator and RABS/BSC cleaning, gloveboxes, pass-through chambers, equipment and work surfaces, benches, confined areas, residue removal, controlled 70% IPA application, surface wetting, and other sterile cleaning procedures where presaturated IPA is specified.
TM-QP70G-258S is supplied sterile and presaturated with 70% IPA. Final suitability should be evaluated according to the target surface, required chemistry, sterile material-flow requirements, contamination-control objective, validated cleaning procedure, and facility SOP.
About the Manufacturer:
Teknipure develops contamination-control products for cleanrooms and other critical and controlled environments. The TekniMop™ platform combines specialized mop frames, interchangeable handles, and application-specific mop covers to create configurable cleaning systems for pharmaceutical and biologics manufacturing, medical device production, compounding pharmacies, laboratories, and other controlled environments.
Within the TekniMop™ small-surface system, Teknipure offers dry, presaturated, sterile, and non-sterile 2-ply polyester mop-cover configurations. This allows facilities to select a format according to cleaning chemistry, sterility requirements, solution-delivery preferences, contamination-control objectives, and established procedures.
TM-QP70G-258S Features:
- Durable 2-ply polyester knit construction
- 2.5" x 8" pocket-style format for small-surface cleaning
- Presaturated with 70% IPA
- Gamma irradiated for sterile cleaning applications
- Sterility assurance level (SAL) of 10-6
- Sterility validated according to AAMI guidelines
- Ready-to-use format eliminates manual measuring or spraying before use
- Consistent IPA wetness level for standardized solution delivery
- Controlled liquid release for uniform surface wetting
- Reliable liquid retention from thick 2-ply construction
- Low particulate-generating polyester construction
- Self-standing resealable gusset packaging
- Resealable packaging helps minimize IPA evaporation and maintain mop saturation
- Compatible with the TKM27 TekniMop™ carbon fiber flat mop frame
- Compatible with the TM-QP258-SS stainless steel 2.5" x 8" mop system
TM-QP70G-258S Benefits:
- Sterility assurance: Gamma irradiation to an SAL of 10-6 supports cleaning procedures requiring sterile consumables.
- Ready-to-use convenience: Factory presaturation with 70% IPA eliminates manual measuring, spraying, and cover saturation before use.
- Consistent solution delivery: Standardized IPA presaturation helps provide repeatable wetness from cover to cover during cleaning procedures.
- Controlled surface wetting: 2-ply polyester construction retains liquid while releasing solution across the target surface.
- Reduced evaporation during use: Resealable gusset packaging helps limit IPA evaporation from unused covers after the package is opened.
- Convenient work-area packaging: The self-standing package reduces the footprint required on work surfaces and provides practical access during cleaning.
- Compact sterile cleaning access: The 2.5" x 8" format supports cleaning of isolators, equipment, work surfaces, pass-throughs, and other areas where larger mop systems may be difficult to maneuver.
- Combined sterile and presaturated format: Eliminates the need to separately source a sterile dry cover and manually apply IPA when a validated procedure specifies sterile 70% IPA cleaning.
Common Applications:
- Sterile isolator cleaning
- RABS/BSC cleaning
- Cleaning gloveboxes and pass-through chambers
- Cleaning equipment surfaces, work surfaces, and benches
- Reaching confined and difficult-to-access areas
- Residue removal
- 70% IPA application and controlled surface wetting
- Sterile cleaning procedures where presaturated IPA is specified
- Routine contamination-control cleaning in aseptic and critical processing environments
Best-Practice Use:
- Select compatible hardware: Use TM-QP70G-258S with a manufacturer-listed compatible frame or mop system, such as the TKM27 carbon fiber frame or TM-QP258-SS stainless steel system.
- Maintain sterile handling: Introduce and handle the sterile presaturated cover according to the facility's material-transfer, aseptic handling, and contamination-control procedures.
- Use directly from the presaturated package: TM-QP70G-258S is supplied with 70% IPA and does not require manual IPA saturation before use.
- Reseal the package: Close the resealable gusset bag promptly after removing the required cover to help minimize IPA evaporation and maintain saturation of the remaining covers.
- Use controlled strokes: Follow the directional wiping or mopping technique established by the facility and avoid transferring contamination back into previously cleaned areas.
- Maintain surface contact: Keep the mop cover evenly engaged with the target surface to support consistent IPA delivery.
- Follow the validated IPA procedure: Maintain the surface conditions and drying requirements established by the facility for 70% IPA cleaning.
- Change covers as required: Replace the mop cover according to cleaning area, contamination load, room transition, solution condition, or other changeout criteria established by the facility.
Selection Notes (TM-QP70G-258S vs. Other TekniMop™ Options)
- TM-QP70G-258S: Choose this version when both sterile presentation and ready-to-use 70% IPA presaturation are required.
- TM-QP258S: Select the sterile dry version when sterile presentation is required but the facility needs control over the cleaning chemistry and saturation level.
- TM-QP70G-258: Select the non-sterile 70% IPA version when ready-to-use IPA presaturation is desired but sterile presentation is not required.
- TM-QP258: Select the dry, non-sterile version when the facility wants full control over cleaning chemistry and sterility is not required.
- Sterile dry vs. sterile presaturated: TM-QP70G-258S reduces point-of-use preparation when 70% IPA is already specified by the cleaning procedure. TM-QP258S provides greater chemistry flexibility when multiple disinfectants or cleaners are used.
- 2-ply polyester vs. microfiber or microdenier: 2-ply polyester emphasizes liquid retention, controlled solution delivery, durability, and low particulate generation. Alternative TekniMop™ materials may be selected when different surface-contact or contamination-removal characteristics are required.
Compatible TekniMop™ Products
Compatible Carbon Fiber Frame
- TKM27: 2" x 7" carbon fiber flat mop frame for isolators, equipment, work surfaces, and confined cleaning areas
Compatible Stainless Steel System
- TM-QP258-SS: 2.5" x 8" stainless steel flat mop frame with extendable handle
Building a TM-QP70G-258S TekniMop™ System
The TM-QP70G-258S is the sterile presaturated mop-cover component of a TekniMop™ small-surface cleaning system. When building a carbon fiber configuration, pair the cover with the compatible TKM27 frame and select a compatible TekniMop™ carbon fiber handle according to the reach required for the cleaning procedure.
Carbon fiber configuration:
TM-QP70G-258S Sterile 70% IPA 2-Ply Polyester Mop Cover + TKM27 Carbon Fiber Frame + Compatible TekniMop™ Carbon Fiber Handle
Stainless steel configuration:
TM-QP70G-258S Sterile 70% IPA 2-Ply Polyester Mop Cover + TM-QP258-SS Stainless Steel Frame & Extendable Handle System
Workflow note: TM-QP70G-258S is supplied sterile and ready to use with 70% IPA. Keep the resealable gusset bag closed when covers are not being removed to help limit IPA evaporation. Sterile material transfer, package handling, cover changeout, surface wetting, use, and disposal should follow the applicable validated cleaning procedure and facility SOP.
Notes: Looking for application guidance or qualification context for the Teknipure TM-QP70G-258S TekniMop™ Sterile 2-Ply Polyester Pocket Mop Cover? Open the SOSCleanroom Technical Vault tab above for detailed sterile small-surface cleaning guidance, 70% IPA application considerations, mop-cover selection, system configuration, cleaning technique, compatibility information, and additional considerations for controlled-environment mopping.
SOSCleanroom.com supports contamination-control programs with cleanroom mop covers, frames, handles, cleaning solutions, and critical-environment consumables backed by responsive product support and reliable supply.
Product page updated: Oct. 26, 2026 (SOS Technical Staff)
© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom) All rights reserved.