Texwipe TX3342 Bulk TOC Cleaning Validation Kit for 72 Samples (Case Qty.)

$440.27
SKU: TX3342 CASE In Stock
(No reviews yet)
Availability:
In Stock
Shipping:
Calculated at Checkout
Type:
Dry Swab
Family:
TOC Validation
Material:
Polyester

Texwipe TX3342 Bulk TOC Cleaning Validation Kit - 72 Samples - 144 TX714K Swabs - 1 Kit/Case

Texwipe TX3342 is a bulk Total Organic Carbon (TOC) cleaning validation kit designed to simplify surface sampling, sample identification, and transportation from manufacturing equipment to the analytical laboratory. Developed for pharmaceutical, biotechnology, medical device, and other contamination-sensitive operations, the kit brings together certified low-TOC vials, low-TOC polyester sampling swabs, and identification labels in a cleanroom-compatible polypropylene transport container.

Each TX3342 bulk kit contains 72 clear 40 mL glass vials with bonded septa caps, 144 TX714K Low TOC Alpha® polyester knit sampling swabs, and 72 blank vial labels. This provides the components for up to 72 vial-based sampling positions, with two TX714K swabs available per vial. The actual number of equipment sampling locations depends on the validation protocol and the number of vials allocated to blanks, controls, or additional testing.

The prewashed vials are certified to a TOC level below 10 µg/L, while the included TX714K swabs are certified below 50 µg/L TOC under the manufacturer's applicable test procedures. The swabs feature a double-layered polyester knit head and a rigid polypropylene handle with a break-away notch, allowing the swab head to be placed directly into the collection vial with minimal handling.

TX3342 is supplied as one complete bulk kit per manufacturer case. Its 72-vial configuration is especially useful for scheduled cleaning validation campaigns, multi-location sampling, and facilities that prefer one organized supply of matched components rather than multiple individually packaged small kits.

Cleaning Validation Advantage: TX3342 provides a complete 72-vial TOC sampling system with 144 certified low-TOC TX714K swabs, cleanroom-compatible vial labels, and an organized transport container. The kit supports standardized sampling, controlled swab-to-vial transfer, sample identification, method-blank collection, and traceable movement of samples from the production area to the laboratory.

Specifications:
  • Manufacturer: Texwipe, an ITW company
  • Manufacturer Part Number: TX3342
  • SOSCleanroom SKU: TX3342 CASE
  • Product Name: Bulk TOC Cleaning Validation Kit
  • Product Family: Cleaning Validation Swabs and TOC Kits
  • Product Type: Complete Surface Sampling Kit for TOC Analysis
  • Kit Configuration: Bulk 72-vial sampling system
  • Manufacturer Case Quantity: 1 complete kit
  • Collection Vials: 72
  • Vial Capacity: 40 mL each
  • Vial Material: Prewashed borosilicate glass
  • Vial Appearance: Clear
  • Vial Cap: Bonded septum cap with one-piece cap-and-septum design
  • Septum Thickness: 1.34 mm (0.053 inch)
  • Vial Protection: Polyethylene overcap
  • Vial Geometry: Sloped shoulder to minimize headspace
  • Certified Vial TOC Level: Less than 10 µg/L (10 ppb)
  • Included Sampling Swabs: 144
  • Included Swab Part Number: TX714K
  • Swab Family: Low TOC Alpha® Polyester Knit
  • Swab Head Material: 100% polyester knit
  • Swab Head Construction: Double-layered, double-knit polyester
  • Swab Head Bonding: Thermal bonding without adhesives
  • Swab Handle Material: 100% polypropylene
  • Swab Handle Color: Light green
  • Swab Handle Design: Rigid, notched, break-away handle
  • Certified Swab TOC Level: Less than 50 µg/L (50 ppb)
  • TX714K Swab Head Width: 12.7 mm (0.500 inch)
  • TX714K Swab Head Thickness: 4.2 mm (0.165 inch)
  • TX714K Swab Head Length: 25.7 mm (1.012 inches)
  • TX714K Handle Length: 101.8 mm (4.008 inches)
  • TX714K Overall Length: 127.5 mm (5.020 inches)
  • Swabs per Vial Position: Two available per collection vial
  • Blank Vial Labels: 72
  • Label Type: Cleanroom-compatible identification labels
  • Transport Container: Cleanroom-compatible polypropylene box
  • External Kit Packaging: Double bagged
  • Traceability: Lot coded for quality control and traceability
  • Published Shelf Life: Five years from manufacture
  • Recommended Storage Temperature: 15-30°C (59-86°F)
  • Sterility: No sterile presentation specified for the standard TX3342 kit
  • Country of Origin: Philippines, per manufacturer technical data sheet
  • Primary Application: Surface sampling for TOC cleaning validation
  • Additional Application: Compatible contamination-investigation sampling under an approved analytical method
  • Manufacturer Technical Reference: Cleaning Validation Swabs & TOC Kits Technical Data Sheet
What Is Included in One TX3342 Case?

Each manufacturer case contains one complete TX3342 bulk kit. The kit provides the sampling supplies for 72 vial-based positions, together with two sampling swabs for each position.

Kit Component Quantity Purpose
40 mL low-TOC glass vials with bonded septa caps 72 Collection and transport of extracted surface samples or assigned controls
TX714K Low TOC Alpha® polyester sampling swabs 144 Surface sampling using the approved collection procedure
Cleanroom-compatible blank vial labels 72 Sample identity, location, and traceability
Organized polypropylene transport container 1 Protected organization and transportation of kit components and samples

Case Quantity: 1 TX3342 kit = 72 vials + 144 TX714K swabs + 72 labels. Blanks and other control samples use collection positions from the available 72 vials unless separately supplied components are allocated. The kit does not contain 72 separate kits or 144 complete sample containers.

About the Manufacturer:

Texwipe, an ITW company, manufactures cleanroom swabs, wipers, and contamination-control products used in pharmaceutical manufacturing, biotechnology, medical devices, precision cleaning, and other critical environments.

Texwipe's cleaning validation products are designed to support repeatable sampling and reduce contamination contribution from the sampling materials themselves. The Alpha® low-TOC sampling swab family uses precision-manufactured polyester heads and polypropylene handles, while its TOC kits combine certified collection vials, swabs, and labels into organized sampling systems.

SOSCleanroom provides Texwipe cleaning validation supplies and supports customers with product selection, sampling-kit configurations, manufacturer documentation, and procurement for regulated cleaning programs.

TX3342 Features:
  • One complete 72-vial bulk TOC cleaning validation kit per case
  • 72 certified low-TOC glass collection vials
  • 144 certified low-TOC TX714K Alpha® polyester sampling swabs
  • 72 cleanroom-compatible vial labels
  • Certified vial TOC level below 10 µg/L
  • Certified swab TOC level below 50 µg/L
  • Prewashed borosilicate glass vial construction
  • Bonded septa caps for controlled sample handling
  • Protective polyethylene vial overcaps
  • Sloped vial shoulders designed to reduce headspace
  • Double-layered polyester knit sampling heads
  • Thermally bonded swab construction
  • Rigid polypropylene handles with break-away notches
  • Swab-head transfer with minimal direct handling
  • Cleanroom-compatible polypropylene transport box
  • Double-bagged external kit packaging
  • Lot identification for traceability
  • Five-year manufacturer-published shelf life
TX3342 Benefits:
  • Consistent Sampling Materials: Matched vials and swabs help limit variation introduced by sourcing different sampling components.
  • Controlled TOC Background: Certified low-TOC consumables support analytical methods requiring attention to blank contribution.
  • 72-Vial Bulk Capacity: Supports larger sampling campaigns and scheduled equipment-cleaning validation activities.
  • Two Swabs per Vial: Provides flexibility for validated sampling methods using paired swabs or multiple passes.
  • Reduced Handling: Notched swab handles support transfer of the swab heads without direct contact.
  • Improved Sample Identification: Included labels support consistent vial tracking from sampling to analysis.
  • Protected Transport: The polypropylene container organizes supplies and helps reduce uncontrolled handling.
  • Lot Traceability: Manufacturer lot codes support investigation of material background and qualification records.
  • Workflow Standardization: One defined kit configuration helps operators and laboratory personnel use repeatable sampling procedures.
  • Audit Support: Documented sampling materials, controls, and chain-of-custody records support data review and cleaning validation investigations.
Common Applications:
  • Pharmaceutical equipment cleaning validation
  • Total Organic Carbon surface sampling
  • Cleaning verification of shared manufacturing equipment
  • Biotechnology process equipment sampling
  • Active pharmaceutical ingredient production equipment
  • Excipients and drug manufacturing equipment
  • Cleaning studies covering multiple sampling locations
  • Controlled investigation of suspected organic contamination
  • Repeatable surface residue trending
  • Qualification of cleaning procedures and sampling methods
  • Swab recovery studies for appropriate surfaces and residues
  • Investigations involving compatible liquid samples under an approved method
Best-Practice Use:
  • Use an Approved SOP: Follow the written sampling and analytical method established for the equipment, surface, and cleaning residue.
  • Define Sample Locations: Identify locations using approved equipment maps and sample identifiers.
  • Use a Defined Area: Apply a qualified sampling area or template where the method requires a known surface area.
  • Control the Diluent: Use the validated wetting and extraction solution at the specified volume and quality.
  • Protect Sampling Materials: Avoid touching swab heads, the interior of vial caps, and the collection surfaces of vials.
  • Maintain Consistent Technique: Use the same prescribed pressure, direction, overlap, and number of passes.
  • Use the Break-Away Handle: Transfer the swab head into the vial without handling the head directly.
  • Cap Promptly: Minimize vial-open time and avoid placing caps on uncontrolled work surfaces.
  • Label Immediately: Link each vial to its location, equipment, cleaning cycle, and sampling record.
  • Include Method Blanks: Collect the controls required to identify contribution from sampling materials, diluent, handling, and transport.
  • Control Transport: Follow the validated sample storage conditions and maximum time to analysis.
  • Document Deviations: Record any difference from the approved collection or handling procedure.
TOC Cleaning Validation Sampling Workflow:

A controlled sampling workflow helps distinguish actual surface residue from variation introduced during sample collection, swab handling, transport, and laboratory preparation. Texwipe's manufacturer instructions describe wetting the swab, sampling the surface, breaking the swab head into the collection vial, capping, and labeling the sample.

  1. Prepare the Sampling Plan: Confirm the equipment identification, sample locations, sampling sequence, acceptance criteria, and required controls.
  2. Verify the Kit: Check TX3342 identification, lot information, expiration, and the availability of vials, labels, and TX714K swabs.
  3. Prepare the Diluent: Use the analytical method's approved low-background solution and specified wetting volume.
  4. Establish the Sample Area: Use the validated area template or defined equipment surface location.
  5. Wet the Swab: Dip the TX714K swab into the approved solution in accordance with the written SOP.
  6. Sample the Surface: Apply the validated stroke pattern, overlap, pressure, and swab orientation.
  7. Use the Second Swab: If required by the method, perform the specified additional passes with the second TX714K swab.
  8. Open the Collection Vial: Remove the cap only when the swab heads are ready for transfer.
  9. Snap the Swab Head: Position the handle notch against the vial rim and break the head into the vial without touching the collection material.
  10. Transfer Additional Swab Heads: Place any required second swab head into the same vial according to the validated method.
  11. Close the Vial: Replace the cap promptly using the proper sample-handling technique.
  12. Identify the Sample: Apply the label and complete the associated sampling record.
  13. Transport to the Laboratory: Keep the vial protected and follow the approved sample holding conditions.
  14. Analyze and Review: Complete the TOC measurement, blank assessment, recovery correction, and acceptance evaluation required by the approved analytical method.

Sampling Technique Guidance: Texwipe's published procedure describes dipping the swab in solution, sampling the area, snapping the swab head into the vial at the handle notch, replacing the cap, and labeling the sample. The facility's approved method determines sampling area, number of swabs, wetting volume, extraction conditions, and analytical acceptance criteria.

Blank Controls and Background TOC Management:

Total Organic Carbon analysis is sensitive to organic contribution from collection materials, extraction liquid, laboratory glassware, operator handling, and environmental exposure. Although TX3342 uses certified low-TOC components, the entire sampling and analytical procedure must be evaluated using suitable blanks and controls.

  • Method Blank: Process the approved blank materials through the relevant analytical steps without collecting residue from the equipment surface.
  • Field Blank: Where required, expose and handle a blank using the defined field procedure without swabbing the target surface.
  • Diluent Blank: Evaluate the organic background of the sampling or extraction liquid.
  • Swab Blank: Assess the contribution from unused swabs under the method's extraction conditions.
  • Vial Blank: Evaluate container and closure contributions when required by the method.
  • Transport Blank: Where appropriate, use a control to assess contamination introduced during storage or transportation.
  • Control Identification: Clearly identify blanks separately from equipment surface samples.
  • Consistent Handling: Use the same relevant vials, swabs, diluent, and handling conditions specified by the method.
  • Review Blank Results: Compare measured blank contribution with the established method limits before accepting sampling results.
  • Investigate Elevated Blanks: Examine diluent preparation, vial-cap handling, swab handling, open-vial time, and transport conditions.

A certified vial level below 10 µg/L and swab level below 50 µg/L describe component background characteristics under manufacturer-defined testing. These values are not direct substitutes for the laboratory's method-blank acceptance criteria and should not automatically be added together to predict the final sample result.

Blank-Control Guidance: Reserve sufficient kit positions for the blanks and quality controls required by the validation plan. For example, when a protocol assigns one of the 72 vials to a field blank, the remaining 71 vials are available for other samples and controls. The number of control vials and their preparation must be defined in the approved method, not assumed from the kit configuration.

Sample Identification and Chain of Custody:

TX3342 includes 72 cleanroom-compatible blank vial labels to support sample identification. A complete traceability system should connect each vial with the specific equipment, sampling location, cleaning event, sampler, kit lot, and laboratory result.

  • Unique Sample ID: Assign an identifier that cannot be confused with another vial.
  • Equipment Identification: Record the equipment or process line sampled.
  • Sampling Location: Identify the precise surface, location code, and relevant area.
  • Cleaning Event: Link the sample to the cleaning batch or cleaning verification event.
  • Sampling Date and Time: Record when collection occurred.
  • Sampler Identification: Identify the operator who collected the sample.
  • TX3342 Kit Lot: Retain the manufacturer's relevant kit or component lot information.
  • Control Classification: Identify blanks, recovery controls, and actual surface samples.
  • Sample Condition: Record deviations, leakage, damaged containers, or unusual collection conditions.
  • Storage and Holding: Document required temperatures and time limits.
  • Laboratory Receipt: Record sample receipt and any condition requiring investigation.
  • Analytical Result: Link the final TOC result to the original sample and approved calculation.

Traceability Guidance: A vial label identifies the container; the complete chain of custody connects that container to the equipment, cleaning record, sampling location, collection procedure, transport history, laboratory analysis, and result review. Use the included labels together with the facility's approved paper or electronic documentation system.

TX714K Swab Construction and Sampling Performance:

The TX714K swabs included in TX3342 use Texwipe's Low TOC Alpha® polyester knit construction. Their double-layered heads provide a defined contact surface for collecting residues from suitable equipment surfaces and releasing collected material into the extraction solution.

  • Double-Layered Knit Head: Supports collection of residues within the polyester knit structure.
  • 100% Polyester Head Material: Provides a controlled textile sampling surface.
  • Thermal Bonding: Avoids adhesives at the swab-head attachment.
  • Rigid Polypropylene Handle: Provides controlled contact pressure and handling.
  • Break-Away Notch: Allows separation of the sampling head for placement into the vial.
  • Low TOC Certification: Supports methods requiring controlled organic background contribution.
  • Light-Green Handle: Provides a recognizable manufacturer identification feature.
  • Large Flat Head: Supports sampling of suitable broad and relatively flat surfaces.
  • Surface Compatibility: Verify appropriate swab contact on coated, soft, rough, or highly textured equipment surfaces.
  • Sampling Recovery: Establish residue-specific recovery using the actual material, swab technique, diluent, and analytical method.
TOC Results, Recovery and Interpretation:

TOC measurements represent total organic carbon detected in the analyzed solution. They do not independently identify which chemical produced the carbon signal. Cleaning validation programs should establish how results are compared with residue limits and how contributions from blanks, swab recovery, sampling area, and extraction volume are handled.

  • TOC Is Nonspecific: It can detect organic contribution from multiple sources without identifying an individual compound.
  • Sampling Area: A defined surface area supports comparison of results across locations.
  • Extraction Volume: Follow the approved method's volume because concentration results depend on the amount of liquid analyzed.
  • Swab Recovery: Validate the recovery of representative residues from the relevant equipment surfaces.
  • Blank Contribution: Evaluate background using the procedure's established blank criteria.
  • Analytical Calibration: Follow the TOC analyzer manufacturer's validated calibration and suitability requirements.
  • Acceptance Limits: Compare appropriately calculated results with the approved cleaning validation limits.
  • Unexpected Results: Investigate possible residue, sampling inconsistency, contaminated diluent, or handling contribution.
  • Method Changes: Evaluate changes to swabs, containers, diluent, area, or extraction method through the applicable quality process.
  • Documentation: Retain raw results, calculations, associated controls, and deviation records according to site requirements.

Analytical Interpretation Guidance: Certified low-TOC consumables help control one source of analytical background, but they do not establish the method detection limit, cleaning acceptance criterion, or sample recovery. Those parameters must be validated for the equipment, residue, and analytical system used.

Selection Notes: TX3342 vs. TX3340:

TX3342 and TX3340 use the same TX714K Low TOC Alpha® sampling swab and certified low-TOC collection vials. The primary difference is the quantity and packaging format.

Specification TX3342 TX3340
Configuration Bulk kit Small kit
40 mL Vials per Kit 72 12
TX714K Swabs per Kit 144 24
Labels per Kit 72 12
Swab Type TX714K TX714K
Manufacturer Case 1 bulk kit 18 small kits
Typical Selection Large sampling campaigns Smaller independent sampling events
  • Choose TX3342: When a single organized 72-vial kit fits the sampling campaign.
  • Choose TX3340: When 12-vial kits are better suited to separate sampling events or teams.
  • Same Sampling Swab: Both contain TX714K, so the primary difference is kit capacity rather than swab-head design.
  • Manufacturer Case Quantity: Compare one TX3342 kit/case with 18 TX3340 kits/case, not one bulk kit against one small kit without considering the purchasing unit.
  • Sampling Controls: Reserve vial capacity for blanks and controls according to each method.

Kit Selection Guidance: TX3342 is the larger 72-vial bulk format. TX3340 is the smaller 12-vial format containing the same TX714K swab. Choose according to sampling campaign size, material staging, and the number of independently controlled sampling events.

Packaging, Shelf Life and Storage:
  • Manufacturer SKU: TX3342
  • Manufacturer Case: 1 complete kit
  • Vials: 72 clear 40 mL low-TOC glass vials
  • Swabs: 144 TX714K Low TOC Alpha® polyester knit sampling swabs
  • Labels: 72 blank cleanroom-compatible vial labels
  • Container: Cleanroom-compatible polypropylene transport box
  • Outer Protection: Double-bagged kit configuration
  • Lot Identification: Manufacturer lot coding for traceability
  • Published Shelf Life: Five years from date of manufacture
  • Recommended Temperature: 15-30°C (59-86°F)
  • Storage Conditions: Clean, protected ambient storage according to manufacturer instructions
  • Before Use: Inspect packaging, vials, caps, swabs, and labels
  • Vial Protection: Keep closed until collection or blank preparation
  • Swab Protection: Avoid handling sampling heads or exposing them unnecessarily before use
  • Sample Transport: Follow the validated holding conditions and time-to-analysis limit
  • Sterility: Standard kit is not identified as sterile
  • Disposal: Follow applicable laboratory and facility requirements for used swabs, glass vials, and sampled residues
Manufacturer Technical Documents:

Texwipe TX3342 Manufacturer Product Information: Click Here

Texwipe Cleaning Validation Swabs & TOC Kits Technical Data Sheet - TX3342 Components and Physical Specifications (PDF): Click Here

Texwipe TX3340 / TX3342 Cleaning Validation Kit Technical Data Sheet and Sampling Instructions (PDF): Click Here

Texwipe Cleaning Validation Product Family and Sampling Resources: Click Here

SOSCleanroom TX3342 Product Information: Click Here

Other Similar Products Available From SOSCleanroom.com

TOC Cleaning Validation Kits and Sampling Supplies

Notes: Need assistance selecting a TOC cleaning validation kit, comparing TX3342 with TX3340, or establishing a controlled swab sampling workflow? Open the SOSCleanroom Technical Vault tab above for additional information on sampling technique, method blanks, swab recovery, vial handling, sample traceability, and TOC result interpretation.

SOSCleanroom.com supports pharmaceutical, biotechnology, medical device, laboratory, and other critical environments with Texwipe cleaning validation kits, low-TOC sampling swabs, cleanroom wipers, and contamination-control supplies. Our team provides manufacturer documentation, product-selection assistance, packaging information, and procurement support.

Product description updated: October 26, 2026 (SOS Technical Staff)

© 2026 SOS Supply. All rights reserved.

The Technical Vault By SOSCleanroom
72-Sample Bulk Kit 72 Low-TOC Vials 144 TX714K Swabs 72 Vial Labels Vials <10 µg/L TOC Swabs <50 µg/L TOC 1 Kit / Case

Texwipe TX3342: bulk low-TOC cleaning validation kit for 72 controlled surface samples

Texwipe TX3342 Bulk TOC Cleaning Validation Kit is an organized sampling system designed for pharmaceutical, biotechnology, and other controlled manufacturing operations requiring reliable collection, identification, and transport of cleaning-validation samples.

Each TX3342 kit contains 72 pre-washed 40 mL glass sample vials, 144 TX714K Low TOC Alpha® polyester sampling swabs, and 72 cleanroom-compatible vial labels. The components are arranged in a cleanroom-compatible polypropylene box designed to support transport between storage, production sampling locations, and the analytical laboratory.

The vials have a manufacturer-certified organic carbon background below 10 µg/L (10 ppb), while the TX714K sampling swabs are certified below 50 µg/L (50 ppb) under the applicable Texwipe test conditions. These characteristics help reduce unwanted analytical background when evaluating residual organic contamination after equipment cleaning.

TX3342 is supplied as one complete 72-sample kit per manufacturer case. Its bulk format is particularly useful when a validation campaign involves multiple locations, equipment components, production lines, or sequential sampling events.

Operations takeaway: TX3342 combines low-background vials, validated low-TOC sampling swabs, identification labels, and organized transport packaging in a single kit. Successful cleaning validation depends on qualified swabbing technique, suitable blanks, residue recovery, sample identification, analytical controls, and accurate documentation.


ISO-first context: cleaning validation and contamination-control programs

ISO 14644-5:2025 establishes an operational framework for cleanroom performance through documented controls involving personnel, equipment, cleaning, maintenance, materials, and contamination management.

In pharmaceutical and biotechnology manufacturing, cleaning validation helps demonstrate that defined cleaning procedures consistently reduce residues to established acceptance limits. Swab sampling allows specified equipment surfaces to be evaluated after completion of a cleaning cycle.

Total Organic Carbon (TOC) analysis is a nonspecific analytical technique used to measure carbon from organic compounds in an aqueous sample. It can support cleaning-validation strategies where the relevant residues are appropriately detected by the selected method.

TX3342 supports this workflow by providing sampling swabs and vials with low published organic carbon backgrounds, helping laboratories distinguish actual surface residues from contamination originating in the sampling system.

Control point: A low-TOC kit supports analytical reliability, but it does not independently establish equipment cleanliness or compliance with a specific cleaning-validation protocol. Sampling locations, recovery, acceptance limits, blanks, extraction conditions, and laboratory methods must be qualified for the intended application.


Specifications (SKU controls for RFQs, SOPs, and receiving)
  • Product: Texwipe Bulk TOC Cleaning Validation Kit
  • Manufacturer: Texwipe, an ITW company
  • Manufacturer part number: TX3342
  • Product family: TOC Cleaning Validation Kits
  • Kit type: Bulk surface-sampling and sample-transport kit
  • Sampling capacity: 72 vial-based sample positions
  • Vials included: 72
  • Vial capacity: 40 mL each
  • Vial construction: Clear, pre-washed borosilicate glass
  • Vial closure: Bonded septum cap with one-piece cap-and-septum design
  • Septum thickness: 1.34 mm (0.053 inch)
  • Vial overcap: Polyethylene
  • Vial shoulder design: Sloped shoulder to minimize headspace
  • Vial TOC qualification: Certified below 10 µg/L (10 ppb)
  • Sampling swabs included: 144
  • Included swab model: Texwipe TX714K
  • Swab head material: Alpha® polyester knit
  • Swab head construction: Double-layered, double-knit polyester
  • Swab handle: Rigid, 100% polypropylene
  • Swab handle feature: Notched break-away design
  • Head bonding: Thermal bond without added adhesive
  • Swab TOC qualification: Certified below 50 µg/L (50 ppb)
  • Blank labels included: 72
  • Label type: Cleanroom-compatible vial identification labels
  • Kit container: Cleanroom-compatible polypropylene box
  • Protective packaging: Double-bagged kit
  • Traceability: Manufacturer lot coded
  • Sterility: No sterile product claim established for the standard TX3342 kit
  • Published shelf life: 5 years from manufacture
  • Recommended storage temperature: 15°C to 30°C (59°F to 86°F)
  • Country of origin: Philippines
  • Manufacturer packaging: 1 complete kit per case
  • Technical documentation: Cleaning Validation Swabs & TOC Kits, US-TDS-059 Rev. 9/21

Ordering control: One TX3342 manufacturer case contains one bulk kit with 72 vials, 144 TX714K swabs, and 72 labels. The kit supports 72 standard vial positions with two supplied swabs per vial position; actual swab allocation must follow the approved sampling method.


Understanding the 72-sample kit configuration

The TX3342 bulk format is designed to organize supplies for validation programs requiring repeated sampling across multiple equipment locations.

  • 72 sample vials: Provide individual extraction and analysis containers.
  • 144 TX714K swabs: Provide two swabs per vial position in the manufacturer's kit configuration.
  • 72 labels: Support unique sample identification and traceability.
  • Polypropylene transport box: Keeps components organized during controlled movement.
  • Double-bagged kit: Supports approved material-entry and contamination-control procedures.
  • Lot coding: Supports traceability to the manufacturer's supplied materials.
  • Single bulk configuration: Reduces the need to assemble multiple smaller kits for larger sampling campaigns.
  • Method flexibility: Can support individual location samples, defined sample sequences, and other approved sampling plans.

Sampling capacity: The 72-sample description refers to 72 included vials, not 144 separate analysis vials. Whether one or both supplied swabs are used per location depends on the written cleaning-validation SOP.


40 mL low-TOC glass vials: controlling sample background

Texwipe supplies 40 mL pre-washed borosilicate glass vials designed to minimize organic carbon contamination contributed by the sample container.

  • Vial material: Borosilicate glass.
  • Vial capacity: 40 mL.
  • Manufacturer-certified background: Below 10 µg/L TOC.
  • Pre-washed construction: Supports low-background sample preparation.
  • Bonded septum cap: Designed for convenient extraction and laboratory handling.
  • One-piece cap-and-septum design: Helps simplify controlled vial handling.
  • Protective polyethylene overcap: Protects the septum surface until the appropriate analytical step.
  • Sloped vial shoulder: Helps minimize headspace and reduce unwanted background contribution.
  • Individual labeling: Supports clear association between sampling location and laboratory result.
  • Sample integrity: Requires proper closure, handling, transport, and extraction procedures.

Vial qualification: The certified <10 µg/L TOC result describes the manufacturer's low-background qualification under specified conditions. It does not guarantee that a filled sample will remain below this concentration after diluent addition, sampling, handling, or storage.


TX714K Alpha® polyester swabs: sampling design and residue recovery

The TX3342 kit includes TX714K Low TOC Alpha® sampling swabs, selected for collecting surface residues while minimizing the sampling material's organic carbon contribution.

  • Swab model: TX714K.
  • Head material: 100% Alpha® knitted polyester.
  • Head construction: Double-layered, double-knit.
  • Head width: 12.7 mm (0.500 inch).
  • Head thickness: 4.2 mm (0.165 inch).
  • Head length: 25.7 mm (1.012 inches).
  • Handle material: Polypropylene.
  • Handle length: 101.8 mm (4.008 inches).
  • Overall swab length: 127.5 mm (5.020 inches).
  • Head attachment: Thermal bond.
  • Handle feature: Break-away notch.
  • Organic carbon background: Certified below 50 µg/L TOC.
  • Sampling function: Collection and subsequent extraction of residues from qualified equipment surfaces.

Swab selection: TX714K provides a relatively broad polyester sampling head suited to accessible equipment surfaces. Confirm that the head geometry, wetting solvent, collection technique, and extraction procedure support the required recovery for the target residue and surface.


Understanding the <10 and <50 µg/L TOC qualifications

Organic carbon introduced by sample containers, swabs, extraction diluents, or handling can interfere with sensitive TOC measurements. Texwipe's low-background component qualifications help reduce this source of analytical variability.

  • Vials: Certified below 10 µg/L (10 ppb) TOC.
  • Swabs: Certified below 50 µg/L (50 ppb) TOC.
  • Different components: Vial and swab background specifications are separately qualified.
  • Concentration basis: Results are expressed as organic carbon concentration under relevant test conditions.
  • Extraction volume: Influences the measured concentration in the final analytical sample.
  • Method blanks: Are necessary to evaluate the full analytical system.
  • Recovery: Must be determined for the target residues and equipment surfaces.
  • Laboratory limits: Acceptance criteria should account for background, recovery, instrument sensitivity, and the intended process.

Analytical interpretation: The values <10 µg/L and <50 µg/L are not additive masses and should not be interpreted as 10 µg per vial or 50 µg per swab. Use actual extraction volumes, validated blanks, and method-specific calculations to evaluate carbon contribution.


Vial cap, bonded septum, and protected analytical transfer

The vial closure is an important component of analytical sample integrity. TX3342 includes bonded septum caps with protective polyethylene overcaps.

  • Bonded septum: Integrated into the vial closure.
  • One-piece design: Simplifies routine closure handling.
  • Septum thickness: 1.34 mm (0.053 inch).
  • Polyethylene overcap: Helps protect the septum surface prior to analysis.
  • Reduced handling: Helps limit unnecessary contact with critical closure surfaces.
  • Sample containment: Requires correct cap installation and vial handling.
  • Instrument compatibility: Verify suitability with the laboratory's TOC analyzer and sampling accessories.
  • Opening control: Remove the closure only for the time required to transfer the sample.
  • Post-transfer closure: Cap promptly and maintain the required identification.

Sample integrity: A low-background vial cannot compensate for contamination introduced by touching the septum, leaving containers open, or using incompatible extraction supplies. Follow the validated laboratory method for closure handling and sample preparation.


Break-away swab handle: controlled transfer into the sample vial

TX714K swabs include a notched polypropylene handle designed to help transfer the sampling head into the vial without manually touching the polyester sampling surface.

  1. Complete the approved sampling pattern: Collect the residue from the designated area.
  2. Prepare the corresponding vial: Verify the correct sample ID and extraction diluent.
  3. Remove the vial cap: Avoid touching the inside of the cap or vial.
  4. Position the sampling head: Place it into the vial opening using the approved handling method.
  5. Use the break-away notch: Separate the head as instructed by Texwipe.
  6. Avoid direct contact: Do not touch the swab head with gloves or unrelated tools.
  7. Confirm placement: Ensure the required sampled material is contained within the correct vial.
  8. Close immediately: Replace the cap according to the method.
  9. Verify identification: Confirm the vial label matches the sampling record.

Transfer technique: Texwipe's break-away design reduces unnecessary handling of the sampled head. The facility SOP must define whether one or two heads are transferred per vial, the extraction volume, and any restrictions on handle fragments entering the sample.


Blank controls: separating equipment residue from sampling background

A cleaning-validation result is meaningful only when the contributions of sampling materials, extraction liquids, containers, and handling are understood. A validated blank program helps detect contamination unrelated to the actual equipment surface.

  • Reagent blank: Evaluates the organic carbon background of the water or other extraction liquid.
  • Vial blank: Evaluates background associated with the low-TOC sample container and closure.
  • Swab blank: Evaluates the swab under the same extraction conditions used for actual samples.
  • Field blank: May assess contamination introduced during handling at the sampling location.
  • Transport blank: May evaluate contamination associated with transport or storage conditions.
  • Method blank: Supports evaluation of the combined preparation and analytical procedure.
  • Blank frequency: Establish how frequently blanks are collected within a sampling batch or campaign.
  • Blank acceptance: Define acceptable background limits using validated criteria.
  • Blank investigation: Investigate unexplained increases before accepting affected results.
  • Blank correction: Apply only where supported by the approved method and applicable validation requirements.

Blank management: The TX3342 kit supplies 72 labeled vial positions. Blanks may use some of those positions if required by the sampling plan. Therefore, the number of actual equipment-location samples can be fewer than 72 when blanks, controls, or repeat samples are included.


Sample identification: using the 72 cleanroom-compatible labels

Accurate identification is essential because a cleaning-validation sample must be traceable from the original equipment surface through extraction, laboratory analysis, and final quality review.

  • Unique sample ID: Assign a nonduplicated identifier to each vial.
  • Equipment ID: Identify the vessel, line, component, or other sampled equipment.
  • Sampling location: Record the exact surface or location designation.
  • Cleaning event: Link the sample to the associated cleaning cycle or batch.
  • Collection date and time: Record the sampling event.
  • Operator: Identify the trained person who collected the sample.
  • Extraction method: Associate the vial with the approved solvent and extraction procedure.
  • Blank designation: Clearly distinguish blanks from equipment samples.
  • Label placement: Use the approved location without interfering with the vial cap or analytical instrument.
  • Verification: Confirm the physical label, sampling worksheet, and laboratory submission agree.

Traceability principle: Each vial must be linked to its equipment location, sampling event, swab and vial supply, operator, analysis, and reported result. A label is only one part of the complete traceability record.


Recommended cleaning-validation sampling workflow
  1. Confirm the validation plan: Verify the equipment, cleaning process, target analyte, and acceptance limits.
  2. Inspect the kit: Confirm TX3342, the expected component quantities, and acceptable packaging condition.
  3. Record the kit lot: Capture relevant manufacturer identification and inventory information.
  4. Assign vial IDs: Prepare the 72 available sample positions in accordance with the approved sampling plan.
  5. Allocate blanks: Reserve any vial positions and swabs required for field, method, or other controls.
  6. Prepare the work area: Follow cleanroom entry and sampling equipment handling procedures.
  7. Identify the sampling surface: Confirm the location and area.
  8. Select the validated wetting solution: Use the specified low-background solvent or water.
  9. Wet the swab: Follow the exact method for volume and technique.
  10. Swab the surface: Apply the specified pressure, stroke count, and direction.
  11. Use the second swab if specified: Follow the approved two-swab collection sequence.
  12. Transfer the sampled heads: Use the break-away handle technique while minimizing contamination.
  13. Close the vial: Ensure appropriate closure and sample identification.
  14. Record the sample: Document area, location, time, operator, and any deviations.
  15. Protect samples during transport: Use the organized kit and required handling conditions.
  16. Transfer to the laboratory: Maintain chain-of-custody and holding-time requirements.
  17. Analyze with controls: Follow the validated extraction and TOC analysis procedure.
  18. Review results: Apply approved blank, recovery, and acceptance-limit calculations.

Method standardization tip: Document the sampling area, swab wetting volume, stroke pattern, number of swabs per vial, extraction volume, blank frequency, transport conditions, recovery correction, and acceptance criteria. These parameters should remain consistent within the validated procedure.


Surface sampling area, recovery, and residue calculations

Equipment residue limits are often expressed relative to a defined surface area. Sampling reliability depends on collecting residues reproducibly and relating the laboratory result back to the correct area and recovery factor.

  • Defined sampling area: Use a qualified surface area or sampling template.
  • Surface type: Evaluate stainless steel, polymers, elastomers, coatings, or other representative equipment materials.
  • Recovery studies: Establish recovery for relevant target residues and surfaces.
  • Swab technique: Standardize contact pressure, movement, and collection sequence.
  • Extraction volume: Record the actual liquid volume used for the analytical sample.
  • Background contribution: Consider the method blank under applicable procedures.
  • Measured concentration: Convert instrument results to collected residue quantity using the validated calculation.
  • Recovery correction: Apply only as specified by the approved analytical method.
  • Reported result: Express the final measurement in the units required by the cleaning-validation protocol.
  • Acceptance: Compare with the approved surface-residue limit.

Analytical control: TOC concentration measured in the vial is not automatically equivalent to residue mass per unit surface area. Converting the result requires the extraction volume, sampled area, appropriate blank handling, and validated recovery methodology.


Organized transport from production to the laboratory

TX3342 is designed to keep sampling supplies and collected samples organized during movement through a cleaning-validation workflow.

  • Polypropylene kit box: Provides an organized container for sampling components.
  • Double-bagged packaging: Supports controlled introduction to appropriate sampling areas.
  • Vial organization: Helps maintain separation and identification of samples.
  • Location tracking: Supports a logical sequence of sample IDs and collection sites.
  • Protected transfer: Minimizes unnecessary exposure during movement between areas.
  • Vial closure checks: Confirm caps are secured before transport.
  • Sample holding time: Follow the validated maximum interval between collection and analysis.
  • Temperature conditions: Maintain the specified conditions for the actual analytes and method.
  • Laboratory receipt: Inspect the sample identifiers, vial integrity, and submitted documentation.
  • Deviation management: Document missing samples, broken vials, incorrect labels, or exceeded holding times.

Transport principle: A cleanroom-compatible box improves organization but does not establish unrestricted sample stability. Follow the qualified holding-time, temperature, containment, and chain-of-custody requirements for the actual analytical procedure.


TX3342 versus TX3340: bulk campaigns or smaller sampling kits?

Texwipe TX3342 and TX3340 use the same TX714K Low TOC Alpha® swab family but differ in how the supplies are grouped and purchased.

  • TX3342 kit capacity: 72 vial positions.
  • TX3342 contents: 72 vials, 144 TX714K swabs, and 72 labels.
  • TX3342 packaging: 1 large bulk kit per case.
  • TX3340 kit capacity: 12 vial positions per individual kit.
  • TX3340 individual kit contents: 12 vials, 24 TX714K swabs, and 12 labels.
  • TX3340 packaging: 18 individual kits per case.
  • TX3340 full-case total: 216 vials, 432 TX714K swabs, and 216 labels.
  • Both swab types: TX714K Low TOC Alpha® polyester.
  • Both vial types: 40 mL low-TOC glass vials with bonded septa caps.
  • Bulk workflow: TX3342 is suitable for organizing a larger continuous sampling campaign.
  • Distributed workflow: TX3340 can be useful when separate smaller kits are needed for multiple departments, sites, or sampling events.

Selection principle: Choose TX3342 when one 72-sample bulk kit matches the validation campaign. Choose TX3340 when multiple separately packaged 12-sample kits better suit the distribution and scheduling of sampling work. The manufacturer's standard full case of TX3340 includes 18 separate kits, not one 12-sample kit.


TX3342 versus TX3343: standard sampling or extended reach?
  • TX3342: Bulk 72-sample kit with 144 TX714K swabs.
  • TX3343: 12-sample kit with 24 TX761K long-handle swabs.
  • TX714K length: 127.5 mm overall.
  • TX761K length: 162.3 mm overall.
  • TX714K head width: 12.7 mm.
  • TX761K head width: 6.8 mm.
  • TX3342 sampling emphasis: Larger accessible surfaces and bulk sampling organization.
  • TX3343 sampling emphasis: Narrow or recessed locations requiring the longer TX761K swab.
  • Method qualification: Changing between sampling heads may require recovery and method reassessment.

Swab geometry: TX3342 and TX3343 are not interchangeable simply because they are both TOC kits. The TX714K and TX761K heads have different dimensions and access characteristics, which may affect collection technique and recovery.


Typical applications for TX3342
  • Pharmaceutical equipment cleaning validation
  • Active Pharmaceutical Ingredient manufacturing equipment sampling
  • Biotechnology processing equipment cleaning assessments
  • Manufacturing changeover qualification
  • Cleaning procedure performance studies
  • Sampling across multiple equipment locations
  • Periodic verification of validated cleaning processes
  • Analytical investigation of organic residue carryover
  • Controlled surface sampling of compatible manufacturing equipment
  • Large sampling campaigns requiring organized vial management
  • Lot-traceable sample collection and laboratory transport
  • Contamination investigations where TOC is an appropriate analytical technique

Application selection: TX3342 is especially useful when a sampling campaign benefits from a large, standardized set of low-background vials, swabs, and labels. The complete analytical method must remain suitable for the residue and equipment surfaces being evaluated.


Five-year shelf life, storage, and inventory control
  • Published shelf life: 5 years from manufacture.
  • Recommended storage temperature: 15°C to 30°C (59°F to 86°F).
  • Original packaging: Keep the kit protected until controlled use.
  • Moisture: Prevent unintended wetting of unused swabs or labels.
  • Organic contamination: Protect from uncontrolled chemical vapors, handling, and contaminated storage areas.
  • Vial integrity: Inspect glass containers and closures before sampling.
  • Kit completeness: Verify all components required by the sampling plan are available.
  • Inventory rotation: Follow the facility's approved expiration-control procedures.
  • Lot records: Record applicable manufacturer and consumable traceability information.
  • Actual expiry: Use the labeled lot-specific date where provided.

Storage control: A five-year published shelf life begins at manufacture, not delivery. Proper storage and handling help preserve the low-background condition of the sampling components before use.


Common sampling and documentation failures
  • Incorrect sample ID: Verify labels against the sampling plan before collection.
  • Missing blanks: Allocate controls according to the validated analytical method.
  • Swab contamination: Avoid touching sampling heads with gloves or unqualified surfaces.
  • Inconsistent swab wetting: Follow the approved extraction or wetting volume.
  • Variable surface area: Maintain defined sampling geometry.
  • Incorrect stroke pattern: Train operators to use the qualified method.
  • Improper head transfer: Use the break-away notch without contaminating the sample.
  • Vial contamination: Protect closures, septa, and open vial interiors.
  • Transport delays: Maintain required holding-time controls.
  • Incomplete records: Document the collection event, operator, location, and lot information.
  • Unqualified swab substitution: Reassess recovery if the sampling material changes.

Misuse controls & when not to use TX3342
  • If a sterile kit is required: Do not assume the standard TX3342 kit is supplied sterile.
  • If the residue cannot be adequately measured by TOC: Use an appropriate alternative or additional analytical method.
  • If narrower or recessed sampling locations are required: Evaluate the TX761K long-handle swab and an appropriately qualified procedure.
  • If the analytical solvent is incompatible: Qualify the chosen swab, vial, and chemistry combination.
  • If no surface-recovery study is available: Do not assume quantitative collection solely from the low-TOC claim.
  • If critical blank limits are exceeded: Investigate the affected samples before reporting conclusions.
  • If a vial is cracked or damaged: Do not use it for controlled sampling.
  • If a swab head contacts an uncontrolled surface: Replace it rather than using it for the sample.
  • If sample holding times are exceeded: Follow the approved laboratory deviation procedure.
  • If a different sampling pattern is proposed: Evaluate the impact on recovery and method performance.
  • If samples are pooled without authorization: Follow the approved method rather than combining locations in an uncontrolled manner.

Recommended related cleaning-validation products

System compatibility: Maintain the approved combination of swab, sample vial, extraction diluent, analytical method, surface type, and recovery calculation. A standardized kit helps control consumable variation but does not replace analytical method validation.


Why purchase Texwipe TX3342 from SOSCleanroom
  • Exact manufacturer kit: SOSCleanroom offers TX3342 with the correct 72-vial, 144-swab, and 72-label configuration.
  • Bulk sampling convenience: One organized kit supports larger cleaning-validation sampling campaigns.
  • Low-background components: Manufacturer-qualified vials and swabs support sensitive TOC analytical workflows.
  • Traceable sampling: Lot-coded materials and cleanroom-compatible labels support sample identification and documentation.
  • Manufacturer technical resources: Product documentation supports review of kit contents, sampling material, vial construction, and use procedures.
  • Customer support: Contact SOSCleanroom for current availability, documentation, and purchasing assistance.

Manufacturer documentation (authoritative references)
  • SOSCleanroom Texwipe TX3342 product page: Click Here
  • Texwipe TX3342 official manufacturer product information: Click Here
  • Texwipe Cleaning Validation Swabs & TOC Kits Technical Data Sheet — US-TDS-059 Rev. 9/21: Click Here
  • Texwipe TOC Cleaning Validation Kits Product Data Sheet — TX3340, TX3342, TX3343: Click Here
  • Texwipe Cleaning Validation Swabs Technical Brochure: Click Here
  • Texwipe Manufacturer Certificates and Quality Resources: Click Here
  • ISO 14644-5:2025 Cleanroom Operations Standard: Click Here
  • FDA Process Validation: General Principles and Practices: Click Here

Technical documentation: Texwipe's technical data identifies TX3342 as one 72-sample bulk kit per case, containing 72 low-TOC 40 mL vials, 144 TX714K Low TOC Alpha® polyester swabs, and 72 cleanroom-compatible labels. The manufacturer's reported vial and swab TOC qualifications should be interpreted under the applicable testing conditions and verified through the facility's validated blank, recovery, extraction, and analytical procedures.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574. OR check out the AI ChatBot powered by SOSCleanroom data libraries - give it a try! THIS IS NEW FOR 2026! © 2026 SOSCleanroom. All rights reserved.