DWK 45240-100 KIMBLE 8" Oil Centrifuge Tube, Standard, 100 mL

$893.20
SKU: 45240-100 CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout

KIMBLE® KIMAX® 45240-100 Oil Centrifuge Tube - 8 Inch, 100 mL, Standard Graduations, 12/Case

KIMBLE® KIMAX® 45240-100 Oil Centrifuge Tubes from DWK Life Sciences are 100 mL graduated borosilicate glass centrifuge tubes designed for petroleum laboratory procedures involving the separation and measurement of water, sediment, and other materials in oil samples. The specialized 8-inch tube geometry supports method-defined centrifugation and reading of separated liquid or sediment layers.

Manufactured from borosilicate glass 3.3, each tube measures 203 mm in length with a 37 mm outside diameter. The tube is calibrated to contain (TC) and features durable white ceramic enamel graduations and legend, with finer scale intervals near the bottom of the tube for reading smaller separated volumes.

DWK references this tube family for petroleum testing methods including ASTM D4007, ASTM D1796, and API MPMS Chapter 10.4, as well as additional methods associated with lubricating oils and petroleum products. Suitability for any specific test depends on the current method's apparatus, dimensional, calibration, and procedural requirements.

The manufacturer specifies a maximum relative centrifugal force (RCF) of 800 × g. The tube mouth is tooled to accept a size 6 snap cap, KIMBLE 28150R-6, when separately selected. The manufacturer package contains 12 tubes per case, with a shelf pack quantity of 6.

Ordering note: Catalog 45240-100 is the standard 100 mL graduated oil centrifuge tube supplied 12 per manufacturer case. The separate 45240LF-100 model features Lazer-Fused™ graduations. The compatible size 6 snap cap, 28150R-6, is a separately selected accessory; its inclusion is not established in the tube-only listing. Always observe the 800 × g maximum RCF.

Specifications:
  • Manufacturer: DWK Life Sciences
  • Brand: KIMBLE® KIMAX®
  • Manufacturer Part Number: 45240-100
  • Product Type: Graduated oil centrifuge tube
  • Product Version: Standard
  • Nominal Capacity: 100 mL
  • Glass Material: Borosilicate glass 3.3
  • Tube Length: 203 mm (approximately 8 inches)
  • Outside Diameter: 37 mm
  • Volumetric Calibration: To contain (TC)
  • Scale and Legend: White ceramic enamel
  • Graduation Interval, 0 to 0.5 mL: 0.05 mL
  • Graduation Interval, 0.5 to 2 mL: 0.1 mL
  • Graduation Interval, 2 to 3 mL: 0.2 mL
  • Graduation Interval, 3 to 5 mL: 0.5 mL
  • Graduation Interval, 5 to 10 mL: 1 mL
  • Graduation Interval, 10 to 25 mL: 5 mL
  • Graduation Interval, 25 to 100 mL: 25 mL
  • Volumetric Tolerances: Manufacturer-specified, variable by measurement range; see The Technical Vault
  • Maximum Relative Centrifugal Force: 800 × g
  • Snap Cap Size: 6
  • Compatible Snap Cap: KIMBLE 28150R-6, separately sourced
  • Manufacturer Case Quantity: 12 tubes
  • Shelf Pack Quantity: 6 tubes
  • Purchase Unit: Case of 12
  • Manufacturer Method References: ASTM D4007, D1796, D91, D128, D1093, and API MPMS Chapter 10.4
  • Supplied Sterility: No product-specific sterile designation established
Why the Graduation Scale Matters

Petroleum centrifuge testing often requires measurement of a relatively small separated water or sediment layer beneath a larger oil sample. The KIMAX oil centrifuge tube therefore uses progressively changing graduation intervals rather than a uniform scale.

Its smallest marked intervals are 0.05 mL from 0 to 0.5 mL, increasing through the scale to 25 mL increments from 25 to 100 mL. DWK also publishes separate volumetric tolerances for different volume ranges. A graduation interval is not the same as a tolerance or measurement uncertainty.

Measurement distinction: This product is calibrated to contain, not calibrated to deliver. Read the separated contents as prescribed by the analytical method. Do not treat the tube as a general dispensing pipette or assume that its volumetric tolerances are uniform across the full 100 mL scale.

About the Manufacturer:

DWK Life Sciences supplies laboratory glassware and scientific products under established brands including KIMBLE®, KIMAX®, WHEATON®, and DURAN®. Its specialized laboratory tube portfolio supports analytical, industrial, petroleum, and research applications.

KIMAX® oil centrifuge tubes are available in the standard white ceramic-enamel graduated version and a separate Lazer-Fused™ version. Selecting the correct catalog number is important when a laboratory specifies a particular marking technology or replacement product.

KIMBLE 45240-100 Features:
  • 100 mL nominal capacity for specialized petroleum centrifugation procedures
  • 8-inch (203 mm) tube length and 37 mm outside diameter
  • Borosilicate glass 3.3 construction
  • Calibrated-to-contain volume scale
  • Durable white ceramic enamel graduations and legend
  • Fine 0.05 mL graduation intervals at the lowest portion of the scale
  • Variable graduation intervals and tolerances matched to specified measurement ranges
  • Manufacturer-specified maximum RCF of 800 × g
  • Tube mouth tooled to accept size 6 snap cap 28150R-6
  • Manufacturer reference to ASTM D4007 and related oil-testing methods
  • Standard graduation configuration, distinct from Lazer-Fused™ model 45240LF-100
  • 6 tubes per shelf pack and 12 tubes per case
KIMBLE 45240-100 Benefits:
  • Fine low-volume resolution: Smaller graduation intervals support readings of low separated water or sediment volumes.
  • Established laboratory format: The 100 mL, 8-inch design is associated with multiple petroleum test methods.
  • Defined dimensional fit: The published 37 mm OD and 203 mm length support evaluation of centrifuge rotor and carrier compatibility.
  • Documented volumetric tolerances: DWK provides range-specific tolerances for the graduated tube.
  • Durable scale: White ceramic enamel markings support visual reading during suitable laboratory workflows.
  • Borosilicate material: Glass 3.3 provides favorable thermal and chemical durability for many laboratory applications, within process limits.
  • Cap option: The formed mouth accommodates the manufacturer-identified size 6 snap cap when separately sourced.
  • Predictable purchasing: A 12-tube case and 6-tube shelf pack support laboratory inventory planning.
Common Applications:
  • Water and sediment determination in crude oil using the appropriate centrifuge method
  • Petroleum product and fuel-oil laboratory testing
  • Crude mineral oil sample analysis
  • Method-defined water-and-sediment testing associated with ASTM D4007 and D1796
  • Petroleum measurement workflows referencing API MPMS Chapter 10.4
  • Lubricating oil and other petroleum-material evaluations referenced by DWK
  • Determination of precipitate volume in specified lubricating-oil tests
  • Other method-qualified industrial liquid centrifugation applications
  • Petroleum quality-control and research laboratories
Best-Practice Use:
  • Verify the product: Confirm catalog 45240-100, 100 mL capacity, standard scale, 37 mm OD, and 203 mm length.
  • Inspect the glass: Reject tubes with scratches, cracks, chips, etching, or other damage.
  • Confirm rotor compatibility: Check the actual tube carrier, bucket, cushions, and centrifuge manufacturer requirements.
  • Respect the RCF limit: Do not exceed the manufacturer's 800 × g rating; determine RPM from the centrifuge's effective rotor radius.
  • Prepare the petroleum sample: Follow the current applicable analytical method for sample preparation, solvent use, filling, conditioning, and centrifugation.
  • Balance the load: Use the manufacturer's approved balanced tube and carrier arrangement.
  • Select a compatible closure: If a snap cap is required, verify the separately sourced size 6 cap and its chemical and operating suitability.
  • Read the specified graduation: Use the correct scale interval and method-defined boundary between separated phases.
  • Account for tolerances: Apply the manufacturer-specified volume-range tolerance and analytical method acceptance criteria.
  • Use solvent safety controls: Petroleum samples and test solvents may be flammable or hazardous; follow the laboratory's safety procedure.
  • Clean after use: Remove residues with a glass-compatible cleaning procedure and inspect the markings and glass before reuse.
  • Discard damaged tubes: Use appropriate laboratory glass waste handling procedures.
Selection Notes (Standard vs. Lazer-Fused™)
  • 45240-100: 100 mL standard oil centrifuge tube with white ceramic enamel graduations; this product.
  • 45240LF-100: Separate 100 mL version with DWK's proprietary Lazer-Fused™ marking technology.
  • Marking Technology: Do not claim that the standard 45240-100 has Lazer-Fused markings.
  • Snap Cap: The tube is designed to accept a size 6 snap cap, manufacturer part 28150R-6; select separately.
  • TC vs. TD: The tube is calibrated to contain liquid, not to deliver a calibrated volume after pouring.
  • 800 RCF vs. RPM: The maximum rated force is 800 × g. The corresponding centrifuge speed varies with rotor radius.
  • ASTM Method Selection: A manufacturer's method reference is not a substitute for validating the complete apparatus against the applicable method edition.
  • Case vs. Shelf Pack: The manufacturer lists 12 tubes per case and 6 per shelf pack. Smaller sales units require SOSCleanroom confirmation.
Important Centrifugation & Petroleum-Testing Considerations

The maximum RCF is 800 × g, based on the manufacturer product specification. RCF is a function of rotor radius and rotational speed; the tube must not be assigned a universal RPM limit without the actual centrifuge geometry.

Petroleum solvents, sample vapors, centrifuge heating, and chemical exposure introduce hazards that require method-specific handling. The tube's maximum RCF rating does not certify a particular centrifuge, seal, or solvent system as safe.

DWK's reference to ASTM D4007 and other test standards establishes the tube's intended method context, not independent certification that any particular laboratory procedure is compliant. The laboratory must follow the current required standard, including all apparatus and quality-control specifications.

The reviewed manufacturer listing does not establish supplied sterility, pressure resistance, a specific cap-included configuration, a validated autoclave cycle, or a lot-specific volumetric calibration certificate.

Manufacturer Documentation:

Glass composition and centrifuge-tube RCF guidance: DWK Glass Types & Properties.

Glassware inspection and safe use: DWK Care & Maintenance of Laboratory Glassware.

General laboratory glassware cleaning: DWK General Glassware Cleaning Advice.

For product-specific tolerance documentation, certificate availability, snap-cap compatibility, or help identifying the appropriate centrifuge tube version, contact SOSCleanroom. General glassware technical guides do not replace the required petroleum-testing standard or instrument instructions.

Related KIMBLE Oil Centrifuge Products

100 mL Oil Centrifuge Tube Versions

  • 45240-100: 8-inch, 100 mL standard graduated oil centrifuge tube, 12/case
  • 45240LF-100: 8-inch, 100 mL Lazer-Fused™ oil centrifuge tube, separate SKU

Related Snap Cap

  • 28150R-6: Manufacturer-identified size 6 snap cap for the compatible tube mouth; request separately

All related items are separate manufacturer catalog products. Verify marking requirements, cap compatibility, manufacturer packaging, and current availability before ordering alternatives or accessories through SOSCleanroom.

Notes: Looking for technical information about KIMBLE® 45240-100 oil centrifuge tubes? Open The Technical Vault for all seven graduation intervals, volumetric tolerances, 800 × g centrifuge safety considerations, ASTM method references, TC calibration principles, and standard-versus-Lazer-Fused™ comparison.

SOSCleanroom supports analytical and industrial laboratories with specialty glassware, laboratory consumables, technical product identification, and responsive purchasing support. For pricing, availability, or manufacturer documentation, email Sales@SOSsupply.com or call (214) 340-8574.

Product page updated: October 29, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom). All rights reserved.

 

The Technical Vault By SOSCleanroom
KIMBLE 45240-100 100 mL Capacity 8-Inch Tube 37 mm OD Borosilicate 3.3 TC Calibrated Max 800 x g 12 / Case

KIMBLE 45240-100: specialized graduated glassware for petroleum centrifuge testing

The KIMBLE® KIMAX® 45240-100 is a standard graduated 8-inch oil centrifuge tube manufactured by DWK Life Sciences from borosilicate glass 3.3. It is intended for petroleum analysis and other specified procedures involving centrifugal separation and volumetric reading of material collected within the tube.

The manufacturer lists a 100 mL capacity, 203 mm length, 37 mm outside diameter, and maximum relative centrifugal force of 800 × g. The scale and legend are made from durable white ceramic enamel, and the tube is calibrated to contain.

The tube's graduation intervals and volumetric tolerances change across the measurement range. Fine increments at small volumes are particularly relevant when measuring separated water and sediment in petroleum samples.

Operations takeaway: The critical purchasing and operating controls are the exact 45240-100 standard SKU, 100 mL TC calibration, 37 × 203 mm dimensions, and 800 × g RCF limit. The method, centrifuge, rotor and carrier, and complete sample preparation procedure must also be qualified.


Specifications (SKU controls for purchasing, method setup, and receiving)
  • Manufacturer: DWK Life Sciences
  • Brand: KIMBLE® KIMAX®
  • Catalog Number: 45240-100
  • Product Family: 8-Inch Oil Centrifuge Tubes
  • Version: Standard
  • Material: Borosilicate glass 3.3
  • Nominal Capacity: 100 mL
  • Tube Length: 203 mm
  • Tube Outside Diameter: 37 mm
  • Calibration: To contain (TC)
  • Graduation Markings: White ceramic enamel
  • Lowest Scale Interval: 0.05 mL, from 0 to 0.5 mL
  • Upper Scale Interval: 25 mL, from 25 to 100 mL
  • Volume Tolerances: Seven manufacturer-specified volume bands
  • Maximum Relative Centrifugal Force: 800 × g
  • Maximum RPM: Depends on centrifuge rotor radius; not separately specified
  • Snap Cap Size: 6
  • Manufacturer-Identified Snap Cap: 28150R-6
  • Shelf Pack Quantity: 6 tubes
  • Manufacturer Case Quantity: 12 tubes
  • Purchase Unit: Case
  • Manufacturer ASTM Reference: D4007
  • Additional Method References: ASTM D1796, D91, D128, D1093 and API MPMS Chapter 10.4
  • Alternative Marking SKU: 45240LF-100, Lazer-Fused™
  • Supplied Sterility: Not established
  • Individual Calibration Certificate: Not established as included by the reviewed listing

Receiving rule: The manufacturer case is 12 tubes, with a shelf pack quantity of 6. The shelf pack designation does not independently establish a separately available six-tube selling unit at SOSCleanroom.


Complete graduation schedule: seven measurement ranges

DWK specifies seven different graduation intervals across the 100 mL tube. The lower portion of the scale uses much finer divisions than the upper portion, allowing smaller separated volumes to be read more closely.

Graduated Range Interval Between Marks
0 to 0.5 mL0.05 mL
0.5 to 2 mL0.1 mL
2 to 3 mL0.2 mL
3 to 5 mL0.5 mL
5 to 10 mL1 mL
10 to 25 mL5 mL
25 to 100 mL25 mL

These values are the manufacturer's graduation intervals, not the tube's allowable volumetric errors. The applicable error limits are provided separately below.

Measurement checkpoint: A 0.05 mL marked interval does not imply ±0.05 mL accuracy, a universal detection limit, or certified precision at every point. Interpret the readings with DWK's tolerance bands and the analytical method's requirements.


Complete volumetric tolerance schedule: seven manufacturer bands

DWK provides the following volume-dependent tolerances for 45240-100. The manufacturer uses a separate tolerance schedule from the graduation interval schedule.

Volume Range Manufacturer Tolerance
0 to 0.1 mL±0.02 mL
Above 0.1 to 0.3 mL±0.03 mL
Above 0.3 to 1 mL±0.05 mL
Above 1 to 3 mL±0.10 mL
Above 3 to 5 mL±0.20 mL
Above 5 to 10 mL±0.50 mL
Above 10 to 100 mL±1.00 mL

The published tolerances apply according to the manufacturer's stated bands. They do not establish an individual instrument calibration certificate, a complete measurement uncertainty budget, or a guarantee that every test result meets its analytical method's accuracy requirements.

Specification note: The tolerance ranges and graduation intervals have different breakpoints. Do not combine them into a single simplified scale or apply the ±0.02 mL value across the entire 100 mL volume.


Calibrated to contain (TC) versus calibrated to deliver (TD)

DWK identifies the 45240-100 oil centrifuge tube as calibrated to contain (TC). This designation means the graduations describe the volume contained in the vessel under the applicable calibration conditions.

A device calibrated to deliver (TD) is designed and calibrated around liquid discharged from the vessel, which may account for residual liquid left behind. These are different volumetric calibration concepts and should not be substituted.

  • TC: Volume held in the tube at the indicated graduation.
  • TD: Volume delivered from a device calibrated for discharge.
  • 45240-100 Designation: TC.
  • Scale Reading: Follow the applicable petroleum method for the correct sample or interface level.
  • Temperature: Use the method's specified conditions and any calibration-temperature requirements.
  • Transfer Operations: Do not use this tube as a certified delivery instrument without independent qualification.

Calibration boundary: A TC marking and manufacturer tolerance table do not prove that an individually supplied tube includes a serialized calibration certificate or traceability document. Request documentation when required by a quality system.


Petroleum testing applications and manufacturer method references

DWK describes KIMAX oil centrifuge tubes for water-and-sediment determinations in petroleum materials and for additional tests on lubricating oils and hydrocarbon liquids. The manufacturer's listing references multiple ASTM and API methods.

Method Reference Manufacturer-Described Context
ASTM D4007 Oil centrifuge tube referenced for laboratory water-and-sediment testing in crude oil
ASTM D1796 Water-and-sediment testing associated with fuel oils and petroleum products
API MPMS 10.4 Manufacturer-referenced petroleum water-and-sediment measurement procedures
ASTM D91 and D128 Manufacturer-referenced lubricating oil and precipitation testing applications
ASTM D1093 Manufacturer-referenced acidity testing involving certain petroleum-related liquids

These references identify manufacturer-described application contexts. They do not establish that a tube, centrifuge, and laboratory procedure automatically conform to the current revision of every listed method.

Regulated testing checkpoint: Before purchasing for an ASTM or API procedure, confirm the current method's required tube design, calibration, centrifuge equipment, sample handling, reagent system, temperature, and acceptance criteria. A method reference is not a product certification.


Water-and-sediment separation: understanding the measured layers

Centrifugation is used in certain petroleum analytical methods to accelerate the separation of components with different physical properties. After the prescribed centrifugation process, separated water and sediment may collect in a lower portion of the tube where they can be read against the graduated scale.

The reading depends on the sample, applicable method, solvent or demulsification process, temperature, centrifugation conditions, and the stability and visibility of the separated layers.

  • Sample Preparation: Follow the approved method for mixing and any reagent additions.
  • Tube Filling: Use the specified liquid quantities and handling approach.
  • Centrifugation: Apply the required conditions without exceeding the tube's RCF limit.
  • Layer Formation: Allow the expected material separation under method-defined conditions.
  • Graduated Reading: Read the specified layer boundaries using the correct scale.
  • Reporting: Calculate and document the result as the governing method requires.
  • Quality Control: Apply method-specific repeatability, acceptance, and corrective-action requirements.

The 100 mL nominal tube capacity does not establish a universal direct conversion between any measured separated layer and a percent-by-volume result. The sample volume, dilution, and prescribed calculation must be considered.


Maximum 800 × g RCF: why it must not be confused with RPM

DWK specifies the maximum relative centrifugal force for the 45240-100 as 800 × g. Relative centrifugal force describes the acceleration imposed on a sample relative to standard gravitational acceleration.

Rotational speed, expressed in RPM, is different. A centrifuge's actual RCF depends on both RPM and the distance from its rotation axis to the point being evaluated. Two different rotor geometries can generate different RCF values at the same RPM.

General centrifuge relationship:

RCF (× g) = 1.118 × 10-6 × radius (mm) × RPM2

  • RCF: Relative centrifugal force expressed as multiples of gravity.
  • Radius: Effective rotation radius, in millimeters, for the point being evaluated.
  • RPM: Rotational speed of the centrifuge.
  • Tube Limit: Maximum 800 × g for 45240-100.
  • Rotor Limit: Also subject to the centrifuge and carrier manufacturer's specifications.
  • Weakest Component: Operate within the lowest applicable safe limit of the tube and complete assembly.

DWK's glass technical guidance specifies evaluating the force at the tube base because that location experiences the maximum RCF. The manufacturer also warns that damaged glass centrifuge tubes can have significantly reduced mechanical strength.

Critical safety limit: 800 × g does not mean 800 RPM. Determine the correct speed using the actual centrifuge's radius and instructions. Never exceed the lower of the tube's maximum RCF or the safe operating limits of the rotor, carrier, closure, or other relevant components.

Review DWK's Centrifuge Tube RCF Guidance


Centrifuge rotor and tube-carrier compatibility

The published 37 mm outside diameter and 203 mm length help laboratories evaluate whether the tube can be safely supported in an appropriate centrifuge.

However, matching the outside diameter and length alone is insufficient. The tube's lower geometry, carrier shape, cushioning, center of gravity, tube clearance, and intended centrifugation conditions all influence compatibility.

  • Tube OD: 37 mm.
  • Tube Length: 203 mm.
  • Rotor or Bucket: Must be approved for the actual glass tube configuration.
  • Tube Support: Use an appropriate carrier, insert, or cushion as specified by the centrifuge manufacturer.
  • Rotor Clearance: Confirm safe operation without contact, interference, or unapproved tube positioning.
  • Balancing: Follow the centrifuge manufacturer's sample-loading and balancing procedures.
  • RCF: Do not exceed 800 × g.
  • Glass Condition: Only use intact tubes free from scratches, chips, and cracks.

Equipment qualification: No universal centrifuge make, model, or rotor part number is approved by the reviewed 45240-100 listing. Verify the exact tube and equipment combination before use.


Snap-cap selection: size 6 and KIMBLE 28150R-6

DWK specifies that the top of the tube is tooled to accept snap cap 28150R-6 and lists the snap-cap size as 6.

The tube's formed mouth and the manufacturer's specified cap identify a compatible closure option, but the current tube specification does not establish that a cap is included in the manufacturer case.

  • Tube SKU: 45240-100.
  • Snap Cap Size: 6.
  • Identified Cap: 28150R-6.
  • Closure Included: Not established by the reviewed tube-only listing.
  • Cap Material: Confirm with manufacturer documentation for the actual cap SKU.
  • Petroleum Compatibility: Evaluate the cap separately against sample liquids and test solvents.
  • Centrifugation: Verify the approved closure setup under the centrifuge and analytical method requirements.

Accessory distinction: A cap designed to fit the tube is not necessarily a pressure-rated, vapor-tight, or universally centrifuge-approved closure. Treat cap retention, chemical compatibility, and operating safety as separate qualification requirements.


45240-100 standard versus 45240LF-100 Lazer-Fused™

DWK offers two catalog numbers within this 100 mL oil centrifuge tube family. The primary distinction in the manufacturer's descriptions is the graduation marking technology.

Attribute 45240-100 45240LF-100
Product versionStandardLazer-Fused™
Capacity100 mL100 mL
Length203 mm203 mm
Outside diameter37 mm37 mm
GlassBorosilicate 3.3Borosilicate 3.3
MarkingStandard white ceramic enamelManufacturer's Lazer-Fused™ technology
Maximum RCF800 × g800 × g
Case quantity1212

The manufacturer's Lazer-Fused™ description applies specifically to 45240LF-100. Although the dimensional and published tolerance data match in current listings, these are different manufacturer SKUs and should remain separate BigCommerce products.

Selection checkpoint: Do not attribute Lazer-Fused™ scale durability or proprietary marking performance to the standard 45240-100. Choose the exact version required by the laboratory's purchasing specification.


Borosilicate glass 3.3: material behavior and chemical limitations

DWK confirms borosilicate glass 3.3 for the 45240-100. This material is widely used for laboratory equipment because of its relatively low thermal expansion, chemical durability, and resistance to many aqueous and organic substances.

DWK's technical guidance also identifies important limitations. Hydrofluoric acid, hot concentrated phosphoric acid, and strong alkaline solutions can attack borosilicate glass. The material designation alone does not establish unlimited resistance to every petroleum solvent, cleaning formulation, or high-temperature process.

  • Confirmed Material: Borosilicate glass 3.3.
  • Typical Strengths: Low thermal expansion and broad laboratory chemical durability.
  • Hydrofluoric Acid: Incompatible with silica-based glass.
  • Hot Concentrated Phosphoric Acid: Can attack glass.
  • Strong Alkaline Solutions: Can cause chemical attack, particularly at elevated temperatures.
  • Petroleum Samples: Evaluate the full reagent and processing environment.
  • Mechanical Stress: Glass strength is affected by scratches, impacts, and thermal damage.
  • RCF Limitation: The rated 800 × g remains applicable even when the glass is chemically suitable.

Qualification boundary: General borosilicate 3.3 material properties are not a finished-product pressure rating, validated thermal cycle, or permission to exceed the manufacturer's centrifugation limit.

Review DWK Glass Types & Properties


Petroleum sample and centrifuge safety considerations

Petroleum samples and method reagents may present flammability, toxicity, vapor, skin-contact, and environmental hazards. Some centrifuge methods also involve heating, solvents, or special rotor arrangements. The laboratory must evaluate the complete operating procedure and equipment.

  • Flammable Materials: Follow the selected method's equipment and ignition-control precautions.
  • Sample Vapors: Use the ventilation and containment measures required for the petroleum material.
  • Glass Breakage: Do not centrifuge visibly damaged or scratched tubes.
  • Rotor Balance: Follow the required loading configuration.
  • Cap Retention: Do not assume a snap cap is suitable for all centrifugation or vapor exposure conditions.
  • RCF: Do not exceed 800 × g.
  • Centrifuge Equipment: Confirm the rotor and accessories are suitable for the actual sample and operating method.
  • Glass Disposal: Use appropriate laboratory broken-glass disposal procedures.
  • Spill Response: Follow the facility's petroleum sample and solvent cleanup procedures.

Safety priority: An intact tube, properly matched centrifuge carrier, controlled sample chemistry, and verified RCF are all necessary. Manufacturer tolerance data do not override safe centrifugation and hazardous-material handling procedures.


Cleaning, residue removal, and care of ceramic enamel graduations

Laboratory glassware used for petroleum analysis may require removal of oils, residues, and any method-specific reagents. Cleaning should preserve both the glass and its white ceramic enamel markings.

DWK recommends inspecting glassware before use and avoiding cleaning tools that can scratch or weaken the glass. The appropriate cleaning solvent should be selected according to the actual sample contamination and laboratory safety procedure.

  • Initial Inspection: Examine the body, tube mouth, lower graduated region, and white enamel scale.
  • Residue Removal: Use an approved glass-compatible solvent or cleaning agent.
  • Avoid Abrasives: Do not use hard implements or wire brushes that could score glass.
  • Rinsing: Follow the method's specified sequence to remove cleaning residues.
  • Drying: Use a procedure appropriate for the glass and any required analytical cleanliness.
  • Scale Readability: Inspect the enamel marks for damage or loss of legibility.
  • Post-Cleaning Inspection: Reject glassware with cracks, chips, scratching, or other defects.
  • Requalification: Apply the laboratory's measurement and equipment-control procedures where necessary.

No SKU-specific validated cleaning solvent sequence, maximum cleaning temperature, or guaranteed lifetime for the graduated scale is established in the reviewed product record.

Cleaning caution: Petroleum residues and cleaning solvents can present chemical hazards even after testing. Avoid damaging the scale or the glass while cleaning, and discard tubes that no longer meet the laboratory's inspection requirements.

Review DWK General Glassware Cleaning Advice


Receiving, packaging, and inspection checklist

DWK specifies 12 tubes per case and a shelf pack quantity of 6. Receiving inspections should verify the standard graduation version and the glassware's physical condition.

  1. Verify Part Number: Match 45240-100 to the purchase order.
  2. Confirm Product Version: Verify standard scale, not Lazer-Fused™ variant 45240LF-100.
  3. Confirm Capacity: Check the 100 mL designation.
  4. Verify Dimensions: 37 mm OD and 203 mm overall length.
  5. Check Material: Borosilicate glass 3.3.
  6. Inspect Graduations: Check the white enamel scale for legibility and visible damage.
  7. Verify Calibration Labeling: Confirm the calibrated-to-contain configuration.
  8. Check Case Quantity: Confirm 12 tubes.
  9. Review Shelf Pack: Verify the manufacturer's designated quantity of 6 where applicable.
  10. Inspect Glass: Reject chipped, cracked, etched, or scratched tubes.
  11. Confirm Equipment Fit: Verify centrifuge, rotor, and carrier compatibility.
  12. Confirm Cap Requirement: Source size 6 snap cap 28150R-6 separately if needed.
  13. Record Disposition: Accept, quarantine, or reject in accordance with the laboratory's quality procedure.

Receiving checkpoint: The manufacturer's current listing establishes the 12-tube case and 6-tube shelf pack. It does not establish individually certified volumetric glassware, included snap caps, or an SOSCleanroom single-tube selling unit.


Storage, handling, and inventory control

Unused glass centrifuge tubes should be stored in a manner that protects their calibrated scale and prevents chips, cracks, and scratches. Avoid impacts or unsupported stacking that could weaken the glass.

  • Protect Glass: Use appropriate racks, dividers, or manufacturer packaging.
  • Protect Graduations: Prevent abrasive contact with the enamel scale.
  • Separate Versions: Store standard 45240-100 and Lazer-Fused™ 45240LF-100 under distinct product identifiers.
  • Check Before Use: Inspect for damage even when the tube has been stored correctly.
  • Maintain Identity: Retain SKU, package, and traceability information as applicable.
  • Follow Facility Procedures: Use approved laboratory glassware handling and storage practices.

No finished-product expiration date, defined shelf life, or SKU-specific controlled-storage range is established by the reviewed manufacturer listing.


Technical FAQs

What is KIMBLE 45240-100 used for?

It is a specialized graduated 100 mL glass centrifuge tube for manufacturer-described petroleum testing methods, including water-and-sediment analysis in crude oil and related oil products.

Does 8-inch refer to the actual tube length?

Yes. DWK identifies the tube as an 8-inch oil centrifuge tube and publishes a length of 203 mm.

What is the outside diameter?

37 mm, as specified by the manufacturer.

Is the tube borosilicate glass?

Yes. DWK specifies borosilicate glass 3.3.

What is the maximum relative centrifugal force?

The manufacturer specifies a maximum of 800 × g.

Is 800 RCF equivalent to 800 RPM?

No. RCF depends on centrifuge speed and rotor radius. The allowable RPM must be determined from the actual equipment geometry and operating instructions.

What is the smallest graduation interval?

0.05 mL, from 0 to 0.5 mL. Larger intervals are used at higher volumes.

What is the tolerance at 0.1 mL?

DWK specifies ±0.02 mL for the 0 to 0.1 mL range. Different tolerances apply above that range.

What does calibrated to contain mean?

The scale represents volume held in the tube under the applicable calibration conditions. It is not a calibrated-to-deliver device.

Is the scale printed in white?

The manufacturer describes the scale and legend as durable white ceramic enamel.

Does 45240-100 use Lazer-Fused™ markings?

No. The Lazer-Fused™ version is the separately cataloged 45240LF-100.

Does this tube work with ASTM D4007?

DWK references ASTM D4007 for the product family. The laboratory must verify that the actual tube, centrifuge, procedure, and required method edition meet all applicable requirements.

Does it work for other petroleum methods?

DWK also references ASTM D1796, D91, D128, D1093, and API MPMS Chapter 10.4 in the product description. Review each method's current requirements before use.

What snap cap fits?

DWK identifies size 6 snap cap 28150R-6. Its inclusion with the tube case is not established, so it should be sourced separately if required.

Is the tube compatible with every centrifuge?

No. The laboratory must verify carrier fit, tube geometry, balancing, and centrifuge ratings for the actual equipment.

Are the tubes individually certified?

The reviewed manufacturer listing provides volumetric tolerances but does not establish an individual serialized calibration certificate as included.

How many tubes are in a shelf pack?

The manufacturer lists a shelf pack quantity of 6.

How many tubes come in a case?

The manufacturer case contains 12 oil centrifuge tubes.

Does the product arrive sterile?

The reviewed manufacturer information does not establish a supplied-sterile designation.

Can a scratched glass tube still be centrifuged?

No. DWK warns that scratches, chips, and abrasions significantly weaken glass centrifuge tubes. Remove damaged tubes from service.


Why purchase KIMBLE oil centrifuge tubes from SOSCleanroom
  • Exact manufacturer SKU identification: SOSCleanroom helps customers distinguish standard graduated and Lazer-Fused™ oil centrifuge tubes.
  • Technical product sourcing: Request assistance confirming dimensions, RCF ratings, volume tolerances, and accessory compatibility.
  • Petroleum laboratory procurement: Source specialized analytical glassware and related consumables through SOSCleanroom.
  • Manufacturer documentation: Ask our team to help obtain available product and technical information.
  • Purchasing clarity: Confirm the manufacturer's 12-tube case and 6-tube shelf pack designations.
  • Responsive service: Contact SOSCleanroom for a formal quotation, availability, and product-identification assistance.

Manufacturer documentation and technical references
  • DWK Glass Types & Properties: Review Glass Material and Centrifuge RCF Guidance — chemical resistance, 3.3-expansion borosilicate properties, and centrifuge-force calculations.
  • DWK Care & Maintenance of Laboratory Glassware: Review Glassware Safety and Inspection Guidance — cleaning, glass inspection, handling, and broken-glass precautions.
  • DWK General Glassware Cleaning Advice: Review Laboratory Glassware Cleaning Advice — general cleaning practices and precautions concerning glass damage.
  • Product-Specific Documentation: Contact SOSCleanroom for assistance requesting applicable volumetric documentation, material specifications, or technical clarification from DWK Life Sciences.

DWK's individual product information confirms the 100 mL capacity, 203 mm length, 37 mm outside diameter, seven graduation intervals, seven tolerance bands, maximum 800 × g RCF, size 6 snap-cap interface, 6-tube shelf pack, and 12-tube case quantity.

Manufacturer glass technical guides are general references. They do not replace the current ASTM or API testing procedure, the centrifuge equipment manual, or product-specific qualification documents.


If you have any questions please email us at Sales@SOSsupply.com or give us a call at (214) 340-8574. For additional product guidance, use the SOSCleanroom AI ChatBot or contact our team for manufacturer documentation assistance. Technical insight: KIMBLE 45240-100 combines a 100 mL TC-calibrated glass tube, fine low-volume graduations, range-specific tolerances, and an 800 × g maximum RCF. Correct petroleum testing requires the approved analytical method, an appropriate centrifuge and rotor, safe solvent handling, and accurate interpretation of the graduated scale. Last updated: October 29, 2026 © 2026 SOSCleanroom. All rights reserved.