Skip to main content

DWK 56900-25210 KIMBLE Sterile Plastic Disposable Serological Pipette, Individually Wrapped, 25 mL

$334.73
SKU: 56900-25210 CASE 7 - 10 Business Days
(No reviews yet)
Availability:
7 - 10 Business Days
Shipping:
Calculated at Checkout

WHEATON® 56900-25210 Sterile Serological Pipette - 25 mL, Polystyrene, Individually Wrapped, 200/Case

WHEATON® 56900-25210 Sterile Disposable Serological Pipettes from DWK Life Sciences are 25 mL polystyrene pipettes designed for precise, convenient liquid transfer in cell culture, tissue culture, research, and general laboratory workflows. Manufactured from polystyrene compliant with USP Class VI material requirements, these clear, graduated pipettes are sterilized by gamma irradiation and supplied in individual paper/plastic peel-open wrappers.

Each pipette is calibrated to deliver (TD), with a manufacturer-specified ±0.5 mL tolerance at its 25 mL nominal capacity, equivalent to ±2% of nominal volume. The 0.2 mL graduations provide readable volume increments, while the bidirectional ascending and descending scales help users monitor liquid uptake and delivery during laboratory procedures.

The pipette includes 10 mL of negative graduations for additional graduated capacity beyond the principal scale. This scale feature should not be confused with an independently certified 35 mL nominal capacity or a guaranteed ±2% accuracy specification at every extended graduation.

DWK specifies a red color-coded band in its current 56900-25210 product listing and classifies the pipette as ASTM Class A. The manufacturer's individually wrapped 56900 series is designed for use where sterile, single-use liquid-handling supplies and convenient individual dispensing are required.

Each pipette is supplied with a plug at the upper end. DWK's manufacturer brochure describes the serological pipette plug as cotton, providing an additional contamination-control feature during appropriate pipetting procedures. Use with a compatible pipette controller or pipette aid as specified by the laboratory.

The manufacturer case contains 200 individually wrapped pipettes, with a shelf pack quantity of 50. Your DWK supplier product-add record identifies this item as made to stock, with room-temperature shipping and storage requirements for the unopened product.

Ordering note: Manufacturer part number 56900-25210 identifies the 25 mL, sterile, individually wrapped WHEATON serological pipette with 0.2 mL graduations and 200 pipettes per case. The 50-count shelf pack is a manufacturer packaging designation; confirm smaller selling units separately. This is not the 56800-25210 multipack configuration. Contact SOSCleanroom for current pricing, inventory, and lead time.

Specifications:
  • Manufacturer: DWK Life Sciences
  • Brand: WHEATON®
  • Manufacturer Part Number: 56900-25210
  • Product Type: Disposable sterile serological pipette
  • Nominal Capacity: 25 mL
  • Construction Material: Polystyrene (PS)
  • Material Compliance: USP Class VI, as stated by DWK
  • Supplied Sterility: Sterile
  • Sterilization Method: Gamma irradiation
  • Packaging Format: Individually wrapped
  • Individual Wrapper: Paper/plastic peel-open packaging
  • Calibration: To deliver (TD)
  • Manufacturer Accuracy Statement: ±2% of nominal capacity
  • Volumetric Tolerance: ±0.5 mL
  • Graduation Interval: 0.2 mL
  • Negative Graduations: 10 mL
  • Graduation Format: Bidirectional; ascending and descending scales
  • Manufacturer-Listed ASTM Classification: Class A
  • Color-Coded Band: Red in current DWK SKU specification
  • Upper Plug: Plugged; manufacturer brochure describes cotton plug
  • Tip Design: Standard serological pipette; no wide-tip designation for this SKU
  • Intended Service: Single use
  • Primary Applications: Cell culture, tissue culture, and general laboratory liquid transfer
  • Manufacturer Shelf Pack Quantity: 50 pipettes
  • Manufacturer Case Quantity: 200 pipettes
  • Purchase Unit: Case (CS)
  • Supplier Country-of-Origin Record: China
  • Supplier Inventory Classification: Made to Stock (MTS)
  • Shipping and Storage: Room temperature, unopened product
  • Expiration: Check the labeled expiry date; no fixed shelf-life duration established by the reviewed SKU record
Where WHEATON Sterile Serological Pipettes Fit in Laboratory Workflows

Serological pipettes are commonly used to transfer measured volumes of culture media, buffers, prepared solutions, and other compatible laboratory liquids. The 25 mL capacity is useful when a workflow requires larger-volume transfers than are practical with many manual micropipettes.

The individually wrapped sterile format supports controlled handling in cell culture and other contamination-sensitive applications. Each unit can be opened as needed rather than exposing a bulk pack of pipettes during repeated retrieval.

Graduations are readable from both ascending and descending directions, supporting the laboratory's selected measurement technique. The clear polystyrene body provides visibility of the liquid level, while the plugged upper end supports appropriate handling with a compatible pipette controller.

Application qualification: Sterile packaging does not automatically establish suitability for every pharmaceutical aseptic process, direct patient use, or specific analytical method. Confirm the required volume tolerance, sample compatibility, sterility documentation, and handling procedure for the intended application.

About the Manufacturer:

DWK Life Sciences supplies laboratory glassware, plasticware, sample containers, and liquid-handling products under brands including WHEATON®, KIMBLE®, KIMAX®, and DURAN®.

The WHEATON sterile disposable serological pipette range includes multiple capacities and packaging options. The 56900 series consists of individually wrapped pipettes; separate 56800 and 56700 series products use multipack and canister packaging, respectively. Exact manufacturer part numbers distinguish capacities, graduation intervals, and packaging quantities.

WHEATON 56900-25210 Features:
  • 25 mL nominal transfer capacity
  • Clear polystyrene construction compliant with manufacturer-stated USP Class VI material requirements
  • Sterilized by gamma irradiation
  • Individually wrapped in peel-open paper/plastic packaging
  • Calibrated to deliver (TD)
  • Manufacturer-specified ±0.5 mL tolerance at nominal capacity
  • 0.2 mL graduation intervals
  • Bidirectional ascending and descending graduation scales
  • 10 mL negative graduation extension
  • Red band in the current DWK product specification
  • Upper plug to support contamination control during appropriate handling
  • ASTM Class A designation in DWK's current product data
  • Manufacturer case of 200 with 50 per shelf pack
  • Single-use design for sterile laboratory workflows
WHEATON 56900-25210 Benefits:
  • Ready for sterile workflows: Gamma irradiation and individual packaging support aseptic handling when the wrapper is intact and the product remains within its labeled expiry.
  • Convenient 25 mL capacity: Suitable for common culture-media and laboratory solution transfer volumes.
  • Defined volumetric performance: A published ±0.5 mL nominal-capacity tolerance supports product selection against method requirements.
  • Readable scales: Clear bidirectional markings allow users to follow ascending or descending volume readings.
  • Extended graduated range: Negative graduations provide additional marked volume beyond the main scale for appropriate laboratory procedures.
  • Clear material: Transparent polystyrene enables observation of the liquid meniscus during pipetting.
  • Individual sterile access: Paper/plastic peel wrappers support dispensing one unit at a time.
  • Practical case packaging: A 200-count case with 50-count shelf packs simplifies laboratory replenishment.
Common Applications:
  • Mammalian cell culture media transfers
  • Tissue culture laboratory workflows
  • Preparation and distribution of compatible laboratory media
  • Transfer of buffered solutions and laboratory reagents
  • Cell suspension handling where pipette geometry and material are suitable
  • Research and development laboratory liquid handling
  • Biotechnology and life science laboratory procedures
  • General laboratory sampling and measured transfers
  • Repeated individually dispensed pipetting tasks requiring sterile single-use consumables
Best-Practice Use:
  • Verify the SKU: Confirm 56900-25210, 25 mL capacity, 0.2 mL increments, and individual packaging.
  • Check the expiry: Review the labeled expiration and batch identification before sterile use.
  • Inspect the wrapper: Do not use units with damaged, compromised, or previously opened sterile packaging.
  • Open aseptically: Peel the wrapper according to the facility's contamination-control procedure.
  • Use an appropriate controller: Attach a compatible pipette aid or controller; never mouth-pipette.
  • Confirm fluid compatibility: Evaluate polystyrene against the liquid and its operating temperature.
  • Read graduations correctly: Follow the laboratory's chosen ascending or descending scale and meniscus-reading method.
  • Observe TD calibration: Deliver the required volume according to the applicable pipette procedure rather than assuming a calibrated-to-contain designation.
  • Check measurement suitability: Consider the ±0.5 mL nominal tolerance and the required accuracy of the procedure.
  • Control contamination: Avoid contact between the tip, wrapper exterior, and nonsterile surfaces.
  • Prevent over-aspiration: Follow pipette-controller procedures and avoid allowing liquid to reach the plug or controller.
  • Do not reuse: Discard after use under the facility's approved waste and contamination-control procedures.
  • Do not autoclave: Do not attempt to heat-reprocess this disposable polystyrene pipette.
Selection Notes (25 mL Pipettes & Packaging Formats)
  • 56900-25210: 25 mL, sterile, individually wrapped, 0.2 mL graduations, 200/case; this product.
  • 56800-25210: Separate 25 mL sterile multipack configuration, 200/case; manufacturer currently identifies this SKU as discontinued with limited stock.
  • 56900-10110: Individually wrapped 10 mL serological pipette, 0.1 mL graduations, 200/case.
  • 56900-50510: Individually wrapped 50 mL serological pipette, 0.5 mL graduations, 100/case.
  • Individual vs. Multipack: The 56900 series uses individual paper/plastic peel packaging; the 56800 series uses plastic bag multipacks.
  • 25 mL vs. 10 mL: Select the size based on liquid transfer volume, required tolerance, available pipette controller, and laboratory procedure.
  • Graduations vs. Tolerance: The 0.2 mL scale interval is not the same as the ±0.5 mL nominal-capacity tolerance.
  • Negative Graduations: The additional 10 mL markings do not create an independently certified nominal 35 mL pipette.
  • Color Band: Current DWK product data specify red; historical brochures differ. Confirm a color-dependent SOP directly with DWK if necessary.
Important Sterility, Accuracy & Chemical Compatibility Considerations

DWK identifies 56900-25210 as sterile following gamma irradiation. Sterility depends on the integrity of the supplied wrapper, appropriate storage and handling, and use within the labeled expiration date. Opening or damaging the sterile barrier can compromise the product's original sterile status.

The pipette is calibrated to deliver (TD). Its published nominal-capacity tolerance is ±0.5 mL at 25 mL, matching the manufacturer's general ±2% statement. Neither the 0.2 mL graduation interval nor the presence of negative graduations establishes a smaller tolerance at every reading.

The pipette body is polystyrene, which has important limitations with certain organic solvents, concentrated chemicals, and heat. Do not assume universal chemical compatibility or autoclave suitability. Evaluate the intended sample and working conditions before use.

DWK manufacturer brochures describe additional controls, including production in an ISO Class 8 cleanroom, SAL 10-6, RNase/DNase-free properties, and non-cytotoxic performance. For regulated or highly sensitive applications, request current lot-specific documentation. Historical brochures also contain conflicting color-band and non-pyrogenic numerical information; these differences require confirmation before making a quantitative customer claim.

Manufacturer Documentation:

WHEATON Serological Pipettes Technical Flyer (2024): Review DWK Serological Pipette Technical Flyer (PDF) — packaging variants, manufacturer performance descriptions, and traceability. Note that its 25 mL color-band entry differs from the current SKU specification.

Polystyrene chemical compatibility: DWK Choosing Laboratory Plasticware for Chemical Compatibility.

General polymer compatibility: DWK Chemical Resistance of Plastics.

For current lot-specific sterility, endotoxin, RNase/DNase, cytotoxicity, and expiry documentation, contact SOSCleanroom. Manufacturer brochures are technical reference material and do not replace current certificates of analysis or batch-specific release records.

Related WHEATON Sterile Serological Pipettes

Individually Wrapped WHEATON 56900 Series

  • 56900-5110: 5 mL, 0.1 mL graduations, 200/case
  • 56900-10110: 10 mL, 0.1 mL graduations, 200/case
  • 56900-25210: 25 mL, 0.2 mL graduations, 200/case
  • 56900-50510: 50 mL, 0.5 mL graduations, 100/case

Alternative Packaging

  • 56800-25210: 25 mL, sterile multipack, 200/case; manufacturer identifies limited remaining availability

Other manufacturer numbers are separate products and may use different inner-pack quantities, color bands, graduation intervals, or packaging formats. Contact SOSCleanroom to confirm current availability and suitable substitutions.

Notes: Open The Technical Vault for detailed information on WHEATON® 56900-25210, including gamma sterility, TD calibration, ±0.5 mL tolerance, negative graduations, polystyrene compatibility, individual packaging, manufacturer quality documentation, and product-family comparisons.

SOSCleanroom supports laboratory and critical-environment procurement with specialty consumables, technical product identification, and responsive customer service. For pricing, current availability, or manufacturer documentation, email Sales@SOSsupply.com or call (214) 340-8574.

Product page updated: October 29, 2026 (SOS Technical Staff)

© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom). All rights reserved.

 

The Technical Vault By SOSCleanroom
WHEATON 56900-25210 25 mL Gamma Sterile Polystyrene Individually Wrapped 0.2 mL Graduations 200 / Case

Product overview and intended laboratory use

WHEATON® 56900-25210 is a sterile, disposable 25 mL serological pipette manufactured by DWK Life Sciences from clear polystyrene. Each pipette is gamma irradiated and individually enclosed in a paper/plastic peel-open wrapper. DWK identifies the family for tissue culture, serological work, and other routine laboratory liquid transfers.

The pipette is calibrated to deliver (TD) with 0.2 mL graduation intervals, a ±0.5 mL tolerance at nominal 25 mL capacity, 10 mL negative graduations, and bidirectional ascending/descending scales. The current manufacturer product listing identifies the band color as red and lists ASTM Class A.

Ordering takeaway: This SKU is the individually wrapped 56900 series, with 50 units per manufacturer shelf pack and 200 pipettes per case. It is not the 56800-series multipack version. Use the complete manufacturer number rather than relying on band color alone.


Verified technical specifications
  • Manufacturer / Brand: DWK Life Sciences / WHEATON®
  • Catalog Number: 56900-25210
  • Product: Disposable sterile serological pipette
  • Nominal Capacity: 25 mL
  • Body Material: Polystyrene (PS); DWK describes the material as USP Class VI compliant
  • Sterility: Supplied sterile after gamma irradiation
  • Packaging: Individual paper/plastic peel-open wrapper
  • Calibration: To deliver (TD), ±2% at nominal capacity
  • Nominal Tolerance: ±0.5 mL at 25 mL
  • Graduation Interval: 0.2 mL
  • Negative Graduations: 10 mL beyond the principal scale
  • Graduation Direction: Ascending and descending
  • ASTM Classification Field: Class A, as listed by DWK
  • Band Color: Red on the current SKU page; historical flyer lists green
  • Upper Plug: Plugged; DWK's brochure describes a cotton plug
  • Manufacturer Shelf Pack: 50 individually wrapped units
  • Manufacturer Case: 200 individually wrapped units
  • Intended Use: Single-use laboratory liquid transfer
  • Supplier-File Origin: China; check current paperwork if a certificate is required
  • Supplier-File Storage: Room temperature for unopened product

Sterility, nominal volume, graduation data, tolerance, and packaging are manufacturer product specifications. Country of origin and logistics values are from the DWK supplier item-setup file and should not be treated as a current inventory or shipping commitment.


TD calibration, graduation spacing, and tolerance

To deliver (TD) means the instrument is calibrated for the liquid volume delivered according to the applicable pipetting procedure; it is not a to-contain (TC) vessel. For this SKU, DWK publishes a tolerance of ±0.5 mL at 25 mL, equivalent to the family's ±2% nominal specification.

25 mL × 2% = 0.5 mL

  • 0.2 mL graduations describe the spacing of printed scale marks, not ±0.2 mL accuracy.
  • 10 mL negative graduations provide additional marked range; they do not reclassify the product as a certified 35 mL pipette.
  • Bidirectional scales allow ascending or descending reading, according to the liquid-transfer method.
  • Partial-volume tolerance and uncertainty at each intermediate or extended marking are not separately quantified on the current SKU page.
  • Controller and technique can affect delivered volume; follow the appropriate drainage and dispensing procedure.

Accuracy checkpoint: Do not confuse graduation resolution with volumetric accuracy. Choose a more precise pipette or calibrated device if the method requires a tolerance tighter than the published ±0.5 mL at nominal capacity.


Sterility, packaging integrity, and aseptic handling

DWK states that these serological pipettes are gamma irradiated and supplied sterile. The individual peel-open wrapper supports dispensing one unit at a time. Sterility after opening depends on appropriate handling and the condition of the original sterile barrier.

The manufacturer's 2024 technical flyer describes a 10-6 sterility assurance level (SAL) for the product family, along with batch and expiration labeling. For regulated use, request a current lot-specific certificate when the sterilization validation or biological cleanliness is an acceptance requirement.

  1. Confirm manufacturer SKU, nominal volume, and package identification.
  2. Check the labeled expiration date and lot number.
  3. Reject torn, punctured, wet, or previously opened wrappers.
  4. Peel the packaging open using the facility's aseptic technique.
  5. Attach a suitable pipette controller without touching the fluid-contact tip.
  6. Prevent liquid from reaching the upper plug or controller.
  7. Dispose of the pipette after its intended single use; do not reprocess.

The manufacturer's brochure describes an easy-to-see cotton plug designed to assist contamination control. It is not a documented substitute for a separately qualified aerosol filter or the laboratory's exposure-control procedures.


Manufacturer quality claims and documentation limits

DWK's serological pipette literature describes ISO Class 8 cleanroom manufacturing, RNase-free and DNase-free performance, non-cytotoxicity, and a non-pyrogenic product-family claim. These are distinct from the product's current SKU-specific fields and should be supported by up-to-date documentation where required by a quality system.

Important source conflict: The September 2024 manufacturer flyer lists both ≤0.5 EU/mL and ≤0.1 EU/mL for non-pyrogenic performance. Do not publish either numerical limit as a definitive, current SKU-specific acceptance value without clarification from DWK.

Quality-document rule: ISO Class 8 refers to a manufacturer-described production environment, not a certified final-product ISO cleanliness class. Request current lot-specific sterilization, endotoxin, nuclease, or cytotoxicity documents where the application requires quantified or independently verified limits.


Color-band discrepancy: current listing versus historical flyer

The current DWK product page and supplier Product Adds record identify a red band for 56900-25210. DWK's September 2024 pipette flyer identifies the same 25 mL SKU as green. Both sources agree on 25 mL capacity, 0.2 mL graduations, negative graduation value, and case quantity.

The current red specification is used for this listing, with the inconsistency disclosed here. For receiving inspections or SOPs that use band color, confirm the physical current-production color with DWK. Always identify the product by SKU and capacity, not color alone.


Polystyrene compatibility and reprocessing limits

WHEATON serological pipettes are made from polystyrene, a clear, rigid material widely used in disposable laboratory liquid handling. DWK states that its pipette polystyrene complies with USP Class VI material requirements. That designation is not a finished-device authorization for direct clinical use.

Polystyrene does not resist every organic solvent or aggressive reagent and is not suitable for steam-autoclave reprocessing. Evaluate the exact solution, contact duration, temperature, and any relevant sample-compatibility or adsorption concerns.

  • Typical workflows: Cell-culture media, compatible aqueous solutions, buffers, and routine laboratory sampling.
  • Check separately: Organic solvents, strong reagents, heat, and sensitive analytical samples.
  • Single use: Do not wash, autoclave, or attempt to restore sterility for reuse.
  • Physical condition: Reject visibly cracked, bent, or damaged pipettes.

DWK Chemical Resistance of Plastics


Packaging levels and related product selection

The 56900 series is individually wrapped. DWK separately identifies the 56800 series as sterile multipacks in plastic bags and the 56700 series as canister packs. These packaging styles should not be substituted where the procedure specifically requires an individual sterile wrapper.

Manufacturer SKUDescriptionCase
56900-2521025 mL, individual wrap, 0.2 mL graduations200
56900-1011010 mL, individual wrap, 0.1 mL graduations200
56900-5051050 mL, individual wrap, 0.5 mL graduations100
56800-2521025 mL, separate sterile multipack configuration200

Case-quantity checkpoint: For 56900-25210, the manufacturer case contains 200 individually wrapped pipettes, with 50 per shelf pack. A shelf pack is not automatically a separately offered SOSCleanroom selling unit.


Receiving, lot identification, and storage checklist
  1. Verify WHEATON brand and 56900-25210 on receiving documentation.
  2. Confirm 25 mL volume, 0.2 mL graduation intervals, and individually wrapped packaging.
  3. Confirm 200 per case; record 50-count shelf-pack configuration as applicable.
  4. Inspect cartons and individual wrappers for damage, contamination, or moisture.
  5. Check manufacturer lot/batch information and expiration date.
  6. Resolve any band-color difference against the approved SKU specification.
  7. Store the unopened product at room temperature under appropriate dry, protected conditions and the manufacturer's labeling.
  8. Request lot-specific sterility or biological-quality documents when required by the facility.
  9. Accept, quarantine, or reject according to the laboratory's quality procedures.

Your DWK item-setup file lists made-to-stock status and room-temperature logistics; neither is a guarantee of current SOSCleanroom inventory. A blank or N/A fixed shelf-life field does not override the expiration printed on sterile packaging.


Frequently asked technical questions

Are the pipettes sterile?

Yes. DWK states that they are sterilized by gamma irradiation and individually wrapped.

What is the nominal accuracy?

The tolerance is ±0.5 mL at 25 mL, equivalent to the manufacturer's ±2% nominal statement.

Do the 0.2 mL markings mean ±0.2 mL accuracy?

No. Graduation spacing and volumetric tolerance are different specifications.

Are the pipettes calibrated to contain or deliver?

To deliver (TD).

Are 10 mL negative graduations provided?

Yes. They extend the marked range but do not change the 25 mL nominal designation.

Is the color band red or green?

The current DWK SKU page lists red; the September 2024 brochure lists green. Verify if color is a controlled receiving attribute.

Can the pipette be reused or autoclaved?

No. It is a sterile single-use polystyrene pipette; do not reprocess.

What is its packaging configuration?

Individual paper/plastic peel wrappers; 50 per manufacturer shelf pack and 200 per case.

Does the product have a published endotoxin limit?

Historical DWK literature gives conflicting values. Request current manufacturer documentation for a numerical acceptance limit.

What is the stated expiration period?

No fixed number of years is confirmed here. Check the expiration printed on the received sterile package.


Manufacturer technical references
  • WHEATON Serological Pipettes Technical Flyer (2024): View manufacturer's technical PDF (includes historical color and conflicting endotoxin values).
  • DWK Chemical Resistance of Plastics: Review compatibility guidance.
  • Current lot-specific documents: Contact SOSCleanroom for available sterility, expiry, and biological-quality verification for 56900-25210.

Manufacturer technical material describes product-family properties. Where lot release, analytical cleanliness, endotoxin, or sterility validation is a required acceptance criterion, obtain the current applicable product-specific records.


Need help selecting WHEATON pipettes? SOSCleanroom can help identify the correct manufacturer SKU, sterile packaging, case quantity, and available technical documentation.

Email Sales@SOSsupply.com or call (214) 340-8574 for pricing and availability.

Last updated: October 29, 2026
© 2026 Specialty Optical Systems, Inc. (dba SOSCleanroom). All rights reserved.